Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sensors (Basel) ; 23(17)2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37687945

RESUMEN

The SOI-FET biosensor (silicon-on-insulator field-effect transistor) for virus detection is a promising device in the fields of medicine, virology, biotechnology, and the environment. However, the applications of modern biosensors face numerous problems and require improvement. Some of these problems can be attributed to sensor design, while others can be attributed to technological limitations. The aim of this work is to conduct a theoretical investigation of the "antibody + antigen" complex (AB + AG) detection processes of a SOI-FET biosensor, which may also solve some of the aforementioned problems. Our investigation concentrates on the analysis of the probability of AB + AG complex detection and evaluation. Poisson probability density distribution was used to estimate the probability of the adsorption of the target molecules on the biosensor's surface and, consequently, to obtain correct detection results. Many implicit and unexpected causes of error detection have been identified for AB + AG complexes using SOI-FET biosensors. We showed that accuracy and time of detection depend on the number of SOI-FET biosensors on a crystal.


Asunto(s)
Biotecnología , Silicio , Adsorción , Probabilidad
2.
Biosensors (Basel) ; 12(11)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36354501

RESUMEN

Quick label-free virus screening and highly sensitive analytical tools/techniques are becoming extremely important in a pandemic. In this study, we developed a biosensing device based on the silicon nanoribbon multichannel and dielectrophoretic controlled sensors functionalized with SARS-CoV-2 spike antibodies for the use as a platform for the detection and studding of properties of viruses and their protein components. Replicatively defective viral particles based on vesicular stomatitis viruses and HIV-1 were used as carrier molecules to deliver the target SARS-CoV-2 spike S-proteins to sensory elements. It was shown that fully CMOS-compatible nanoribbon sensors have the subattomolar sensitivity and dynamic range of 4 orders. Specific interaction between S-proteins and antibodies leads to the accumulation of the negative charge on the sensor surface. Nonspecific interactions of the viral particles lead to the positive charge accumulation. It was shown that dielectrophoretic controlled sensors allow to estimate the effective charge of the single virus at the sensor surface and separate it from the charge associated with the binding of target proteins with the sensor surface.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanotubos de Carbono , Humanos , SARS-CoV-2 , Técnicas Biosensibles/métodos , Pandemias , Anticuerpos Antivirales
3.
Biosensors (Basel) ; 11(4)2021 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-33921281

RESUMEN

The detection of influenza A virions with a nanoribbon detector (NR detector) has been demonstrated. Chips for the detector have been fabricated based on silicon-on-insulator nanoribbon structures (SOI nanoribbon chip), using a complementary metal-oxide-semiconductor (CMOS)-compatible technology-by means of gas-phase etching and standard optical photolithography. The surface of the SOI nanoribbon chip contains a matrix of 10 nanoribbon (NR) sensor elements. SOI nanoribbon chips of n-type conductance have been used for this study. For biospecific detection of target particles, antibodies against influenza virus have been covalently immobilized onto NRs. Influenza A virus detection was performed by real-time registration of the source-drain current through the NRs. The detection of the target viral particles was carried out in buffer solutions at the target particles concentration within the range from 107 to 103 viral particles per milliliter (VP/mL). The lowest detectable concentration of the target viral particles was 6 × 10-16 M (corresponding to 104 VP/mL). The use of solutions containing ~109 to 1010 VP/mL resulted in saturation of the sensor surface with the target virions. In the saturation mode, detection was impossible.


Asunto(s)
Técnicas Biosensibles , Orthomyxoviridae/aislamiento & purificación , Transistores Electrónicos , Nanotubos de Carbono , Nanocables , Análisis de Secuencia por Matrices de Oligonucleótidos , Óxidos , Semiconductores , Silicio
4.
Atmos Environ (1994) ; 38(23): 3879-3884, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32288549

RESUMEN

Due to recent SARS related issues (Science 300 (5624) 1394; Nature 423 (2003) 240; Science 300 (5627) 1966), the development of reliable airborne virus monitoring procedures has become galvanized by an exceptional sense of urgency and is presently in a high demand (In: Cox, C.S., Wathers, C.M. (Eds.), Bioaerosols Handbook, Lewis Publishers, Boca Raton, FL, 1995, pp. 247-267). Based on engineering control method (Aerosol Science and Technology 31 (1999) 249; 35 (2001) 852), which was previously applied to the removal of particles from gas carriers, a new personal bioaerosol sampler has been developed. Contaminated air is bubbled through porous medium submerged into liquid and subsequently split into multitude of very small bubbles. The particulates are scavenged by these bubbles, and, thus, effectively removed. The current study explores its feasibility for monitoring of viable airborne SARS virus. It was found that the natural decay of such virus in the collection fluid was around 0.75 and 1.76 lg during 2 and 4 h of continuous operation, respectively. Theoretical microbial recovery rates of higher than 55 and 19% were calculated for 1 and 2 h of operation, respectively. Thus, the new sampling method of direct non-violent collection of viable airborne SARS virus into the appropriate liquid environment was found suitable for monitoring of such stress sensitive virus.

5.
Environ Microbiol ; 9(4): 992-1000, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17359271

RESUMEN

We have recently developed a new personal sampler and demonstrated its feasibility for detection of viable airborne microorganisms including bacteria, fungi and viruses. To accelerate the time-consuming analytical procedure involving 2-5 days of biological testing, we employed a real-time PCR protocol in conjunction with the personal sampler for collection of airborne viruses. The advantage of this approach is that if the presence of a particular pathogen in the air is detected by the PCR, the remaining collecting liquid can be further analysed by more time-consuming biological methods to estimate the number of airborne infectious/live microorganisms. As sampling of bioaerosols in natural environments is likely to be associated with substantial contamination by a range of microorganisms commonly existing in an ambient air, an investigation of the specificity of detection by targeted PCR analysis is required. Here we present the results of the study on the detection of Influenza virus in the ambient air contaminated with high concentrations of bacteria and fungi using real-time PCR protocol. The combined sampling PCR detection method was found to be fully feasible for the rapid ( approximately 2.5 h) and highly specific (no cross-reactivity) identification of the labile airborne virus in the air containing elevated concentrations of other microorganisms.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/instrumentación , Exposición por Inhalación/análisis , Virus del Sarampión/aislamiento & purificación , Orthomyxoviridae/aislamiento & purificación , Reacción en Cadena de la Polimerasa/métodos , Bacterias , ADN Viral/análisis , Monitoreo del Ambiente/métodos , Hongos , Humanos , Control de Infecciones/instrumentación , Control de Infecciones/métodos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/análisis , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Material Particulado/análisis , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA