Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Rheumatology (Oxford) ; 51(12): 2164-9, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22829691

RESUMEN

OBJECTIVE: To evaluate the prevention of joint destruction and clinical efficacy of low-dose etanercept (ETN) (25 mg/week) compared with standard-dose ETN (50 mg/week) in RA. METHODS: In this prospective, randomized, open-label study, 70 patients were assigned to receive ETN at either 50 or 25 mg/week for 52 weeks. The primary endpoint was the variation in modified total Sharp score (mTSS), and secondary endpoints were variations in disease activity score in 28 joints (DAS-28), modified HAQ and adverse event rate. Values of mTSS were calculated at baseline and after 52 weeks. Non-progression was estimated as ΔmTSS ≤0.5, and the non-progression rate was compared between groups. RESULTS: Mean values at baseline were as follows: disease duration 9.2 years; DAS-28 5.45; and annual progression of mTSS 26.1. No significant differences in background were seen between groups. At 52 weeks, the non-progression rate was significantly less in the 25 mg/week group (36.7%) than in the 50 mg/week group (67.7%) (P = 0.041). Mean ΔmTSS was higher at 25 mg/week (1.03) than at 50 mg/week (-0.13). DAS-28 was significantly improved at 4 weeks, and the effect of treatment lasted for 52 weeks in both groups. No differences in adverse event rates were seen between groups. CONCLUSION: Low-dose ETN is not inferior to standard-dose ETN in terms of effects on clinical manifestations. However, in terms of the radiographic non-progression rate, the effects of low-dose ETN may be inferior to the effects of standard-dose ETN. TRIAL REGISTRATION: UMIN Clinical Trials Registry, http://www.umin.ac.jp/ctr/, UMIN000001798.


Asunto(s)
Antirreumáticos/administración & dosificación , Artritis Reumatoide/tratamiento farmacológico , Enfermedades de los Cartílagos/prevención & control , Inmunoglobulina G/administración & dosificación , Receptores del Factor de Necrosis Tumoral/administración & dosificación , Antirreumáticos/efectos adversos , Artritis Reumatoide/patología , Enfermedades de los Cartílagos/inducido químicamente , Enfermedades de los Cartílagos/patología , Progresión de la Enfermedad , Relación Dosis-Respuesta a Droga , Etanercept , Femenino , Humanos , Inmunoglobulina G/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento
2.
Medicine (Baltimore) ; 101(24): e29388, 2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35713443

RESUMEN

ABSTRACT: Prospective case-control studyThis study aimed to investigate the effect of self-quarantine on the changes in low back symptoms and activities of daily living (ADL) due to low physical activity because of the COVID-19 pandemic in patients with lumbar spinal stenosis (LSS).The frequency and intensity of low back and leg pain have reportedly increased in healthy subjects because of self-quarantine.Patients with LSS who self-quarantined from baseline (SQ group) were matched to controls who did not self-quarantine (non-SQ group), based on age, sex, medication, ADL, and the numeric rating scale score for low back symptoms. The change in low back symptoms, ADL, and health-related quality of life between baseline and follow-up were compared between the groups.The SQ and non-SQ group included 80 and 60 patients, respectively. Compared with the baseline, the numeric rating scale score for low back pain at follow-up in the SQ group significantly improved (P = .004, median; 1 point), but not in the non-SQ group. No significant difference was found regarding changes in leg pain or numbness. Low back pain improvement did not lead to ADL improvement. The short form 12 evaluation revealed the role/social component score in the SQ group to be significantly lower than that in the non-SQ group; no difference was found for the physical or mental components at follow-up.Self-quarantine with conservative treatment effected short-term low back pain improvement in patients with LSS. However, no improvement in ADL was found. Self-quarantine had an unfavorable impact for health-related quality of life. The effect of self-quarantine can influence the treatment results of LSS.


Asunto(s)
COVID-19 , Dolor de la Región Lumbar , Estenosis Espinal , Actividades Cotidianas , COVID-19/epidemiología , Estudios de Casos y Controles , Descompresión Quirúrgica/métodos , Humanos , Dolor de la Región Lumbar/etiología , Vértebras Lumbares/cirugía , Pandemias , Calidad de Vida , Cuarentena , Estenosis Espinal/cirugía , Resultado del Tratamiento
3.
J Arthroplasty ; 24(5): 674-80, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18534399

RESUMEN

Recently, use of high-flexion design was introduced in cruciate-retaining (CR) total knee prostheses. The purpose of this study was to prospectively compare the ranges of motion (ROMs) of 89 knees with standard and 87 knees with high-flexion CR total knee prostheses. Differences in age, gender, diagnosis, preoperative ROM of the knee, and Knee Society Score between the 2 groups were not statistically significant. At 12-month follow-up, average ROM was 112.0 degrees +/- 12.6 degrees for standard, and 115.3 degrees +/- 13.4 degrees for high-flexion CR prosthesis (P = .101). To our knowledge, this is the first report on the ROM with the high-flexion CR total knee prosthesis. Using the technique of anterior referencing for femoral component sizing and using a fixed 7 degrees slope for the tibial component, we found no significant differences between groups with regard to ROM, clinical, or radiographic parameters.


Asunto(s)
Artritis/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de la Rodilla , Rango del Movimiento Articular , Anciano , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis
4.
Arch Orthop Trauma Surg ; 129(9): 1151-6, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18427818

RESUMEN

INTRODUCTION: In total hip arthroplasty (THA), acetabular component orientation has critically important effects on dislocation, range of motion, polyethylene wear, pelvic osteolysis, and component migration. The differences in the pelvic orientation in the intraoperative lateral position for insertion of acetabular component during operation and that in the postoperative supine position for evaluation of acetabular component orientation will be one of the factors, which make outliers in acetabular component orientation. We compared acetabular component orientation between intraoperative lateral position and postoperative supine position in 100 consecutive primary THAs. MATERIALS AND METHODS: A total of 100 consecutive primary THAs (between October 2004 and December 2005) in 100 patients performed by a single surgical team were investigated. Intraoperative anteroposterior radiographs of pelvis in the lateral position and postoperative anteroposterior radiographs of pelvis in the supine position were taken. Acetabular component orientation (vertical tilt and anteversion) were measured using computer software. RESULTS: The absolute values of difference between measurements in the two positions were 5.3 degrees +/- 4.5 degrees (mean +/- SD) for vertical tilt and 5.1 degrees +/- 3.7 degrees for anteversion. The difference in the vertical tilt between the two positions was significant (P < 0.0001). CONCLUSION: The difference in the acetabular component orientation between the two positions, which might be caused by the difference between intra- and postoperative pelvic orientation, should be considered during THA.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera , Prótesis de Cadera , Posición Supina/fisiología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Cuidados Posoperatorios , Postura , Radiografía , Rango del Movimiento Articular , Resultado del Tratamiento
5.
Medicine (Baltimore) ; 97(38): e12462, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30235736

RESUMEN

To reduce costs of biological disease-modifying antirheumatic drugs (bDMARDs), we evaluated the efficacy of repeated etanercept (ETN) discontinuation and restarting in rheumatoid arthritis (RA) patients in a case-control study.Thirty-one bDMARD-naive RA patients with moderate to high disease activity received ETN until low disease activity (LDA) was achieved, after which ETN was discontinued. Upon flaring, ETN was readministered with observation every 2 months for 2 years, and radiographically evaluated in comparison with a historical control group treated continuously with ETN. Statistical methods including Fisher exact test, analysis of variance (ANOVA), Kruskal-Wallis test, multiple regression analysis, and Student t test were conducted as appropriate.Thirteen patients with inadequate response to ETN were withdrawn from the study, and 5 had no flare-up after ETN discontinuation. In the remaining 13 patients, ETN was used on-demand to maintain LDA. Multivariate analysis revealed that MTX was significantly correlated with ETN. All 13 patients achieved LDA at final follow-up. Although joint damage progressed in patients using ETN on-demand, structural damage progression in the on-demand group was not significantly different from that in controls.On-demand use of ETN for flaring reduced disease activity but not structural damage in 50% of patients (though not significantly). However, inhibition of joint damage was achieved in 50% of patients after 2 years, supporting on-demand use of ETN as a treatment option for patients with RA who cannot afford bDMARD or targeted synthetic DMARD therapy.


Asunto(s)
Antirreumáticos/administración & dosificación , Artritis Reumatoide/tratamiento farmacológico , Etanercept/administración & dosificación , Anciano , Análisis de Varianza , Artritis Reumatoide/diagnóstico por imagen , Estudios de Casos y Controles , Esquema de Medicación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Radiografía/estadística & datos numéricos , Análisis de Regresión , Índice de Severidad de la Enfermedad , Brote de los Síntomas , Factores de Tiempo , Resultado del Tratamiento , Privación de Tratamiento
6.
Knee ; 16(5): 348-51, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19268598

RESUMEN

The use of highly cross-linked polyethylene in total knee prostheses is still controversial. The aim of the present study was to compare radiographic and clinical results of using conventional and highly cross-linked polyethylene in cruciate retaining total knee prostheses of completely the same design. Two hundred and two consecutive total knee arthroplasties (NexGen CR, Zimmer) were performed using the same procedure. The first consecutive 113 knees had conventional polyethylene insert and following consecutive 89 knees had highly cross-linked polyethylene insert (Prolong, Zimmer). Differences in the age, gender, and diagnosis between two groups were not statistically significant. Preoperative range of motion (ROM) of the knee, and Knee Society Score (KSS) was better in highly cross-linked polyethylene group. Clinical and radiographic results were evaluated at two years after operation. The difference of ROM and KSS between groups was not statistically significant. There was no revision surgery. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. There was no early catastrophic clinical failure due to use of the new material.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Polietileno , Diseño de Prótesis , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Reactivos de Enlaces Cruzados/química , Femenino , Indicadores de Salud , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Polietileno/efectos adversos , Polietileno/química , Falla de Prótesis , Radiografía , Rango del Movimiento Articular
7.
Acta Orthop ; 80(4): 486-90, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19593719

RESUMEN

BACKGROUND: Although nasal carriage of MRSA has been identified as one of the risk factors for surgical site infection (SSI) with MRSA, there have been no reports of this in the orthopedics field. METHODS: This prospective observational cohort study included 2,423 consecutive patients who were admitted to our department over 26 months and who underwent orthopedic surgery. We examined the relationship between pre-existing nasal MRSA and subsequent occurrence of SSI with MRSA. RESULTS: 63 patients (2.6%) had a positive nasal MRSA culture. 15 patients (0.6%) developed SSI with MRSA. The occurrence of SSI with MRSA in nasal MRSA carriers was significantly higher than that in non-carriers (4 out of 63 (6.3%) vs. 11 out of 2,360 (0.5%); p < 0.001) (adjusted OR: 11; 95% CI: 3-37; p = 0.001). INTERPRETATION: We recommend appropriate treatment of patients who are nasal carriers of MRSA before orthopedic surgery.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina/aislamiento & purificación , Cavidad Nasal/microbiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Estafilocócicas/microbiología , Infección de la Herida Quirúrgica/microbiología , Adulto , Anciano , Anciano de 80 o más Años , Portador Sano/microbiología , Portador Sano/prevención & control , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/prevención & control , Factores de Riesgo , Infecciones Estafilocócicas/tratamiento farmacológico , Infección de la Herida Quirúrgica/prevención & control , Adulto Joven
8.
J Biomed Mater Res B Appl Biomater ; 86(2): 501-5, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18360879

RESUMEN

Polyethylene wear particles are one of the most important factors affecting the results of total hip arthroplasty (THA). To reduce wear generation and to achieve better long-term results of THA, highly crosslinked polyethylene (HXPE) has recently been introduced and come into wide use. Thus far, however, there have been no reports on in vivo analysis of HXPE wear particles. We isolated HXPE wear particles from periprosthetic tissue of a failed THA and analyzed using scanning electron microscope. The number of particles was 5.33 x 10(7) g(-1). Particle size (equivalent circle diameter) was 0.66 +/- 0.40 microm (mean +/- standard error). Aspect ratio and roundness were 1.37 +/- 0.26 and 1.44 +/- 0.67, respectively. All the particles were round shaped, and "fibrils" or "shreds" were not detected. Thus far, this was the first report on in vivo wear particle analysis of HXPE. HXPE generated less, smaller, and rounder particles, compared with the corresponding reported values for particles generated from conventional polyethylene. These characteristics might affect macrophage response, osteolysis, and long-term results of THA with HXPE.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Polietilenos/normas , Falla de Prótesis , Artroplastia de Reemplazo de Cadera/normas , Análisis de Falla de Equipo , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Polietilenos/uso terapéutico
9.
Knee Surg Sports Traumatol Arthrosc ; 15(11): 1321-5, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17684727

RESUMEN

It has been reported that preparation of the flexion gap results in significant widening of the prepared extension gap in posterior stabilized (PS) total knee arthroplasty (TKA). To date, there is a paucity of data regarding cruciate ligament-retaining (CR) TKA. Changes in the extension gap caused by preparation of the flexion gap were measured in 42 varus osteoarthritic knees undergoing CR TKA. The extension gap was first prepared and then measured before and after preparation of the flexion gap. The extension gap increased significantly on both the medial and lateral sides (18.8-20.0 and 21.7-22.7 mm, respectively) (P < 0.01). Preparation of the flexion gap also resulted in significant widening of the extension gap on CR TKA. However, amount of extension gap increase in CR TKA was smaller than previous reports on PS TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Ligamento Colateral Medial de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Ligamento Cruzado Posterior/cirugía , Rango del Movimiento Articular/fisiología , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Radiografía , Estudios Retrospectivos , Resultado del Tratamiento
10.
Arch Orthop Trauma Surg ; 124(5): 317-9, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15060833

RESUMEN

INTRODUCTION: The risk of requiring allogeneic blood transfusion after total knee arthroplasty has been recently decreased with several methods such as blood donation, blood salvage, and hematinic. For patients with a low baseline hemoglobin level, however, the rate of allogeneic transfusion is still high, and an effective method for avoiding allogeneic blood transfusion has not been established. We introduced intra- and postoperative blood salvage with the Cell Saver for patients with a baseline hemoglobin level lower than 130 g/l and analyzed the frequency of allogeneic blood transfusion. MATERIALS AND METHODS: From 1993 to 1997, 218 consecutive total knee arthroplasties were performed, and 155 knees with baseline hemoglobin lower than 130 g/l were included in this study. Baseline hemoglobin ranged from 62 to 129 g/l, with a mean of 110 g/l. All patients were managed with intra- and postoperative blood salvage with the Cell Saver. Preoperative autologous blood donation and/or use of hematinic was performed for 129 knees (group 1) and was not performed for 26 knees (group 2). There were no significant differences between the two groups with regard to preoperative factors. To examine the role of perioperative factors (age, sex, baseline hemoglobin level, revision procedure, preoperative blood donation, and use of hematinic) in determining the requirements for allogeneic transfusion, backward elimination logistic regression analysis was used. RESULTS: Seven knees (4.5%) required allogeneic transfusion. Group 1 (2.3%) exhibited a lower rate of allogeneic blood transfusion than group 2 (15.4%) (p=0.016). Hemoglobin levels on the day (p=0.016), 1 week (p=0.0001), and 2 weeks (p=0.007) after surgery were lower in group 1 than in group 2. Backward elimination logistic regression analysis showed that preoperative blood donation (p=0.048) and use of hematinic (p=0.040) were significantly associated with a requirement for allogeneic blood transfusion. CONCLUSION: Preoperative blood donation and use of hematinic were associated with a low incidence of allogeneic blood transfusion after total knee arthloplasty with intra- and postoperative blood salvage, even for patients with a baseline hemoglobin level below 130 g/l.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Pérdida de Sangre Quirúrgica , Transfusión Sanguínea , Hemoglobinas/análisis , Anciano , Transfusión de Sangre Autóloga , Femenino , Humanos , Modelos Logísticos , Masculino , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA