Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Clin Oncol ; 27(10): 1589-1595, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35945389

RESUMEN

BACKGROUND: We prospectively evaluated the safety and efficacy of percutaneous cryoablation combined with transcatheter renal arterial embolization for the treatment of tumors ≥ 3 cm in diameter. METHODS: We included patients aged ≥ 20 years with histologically proven renal cell carcinoma with a tumor diameter ≥ 3 cm who were inoperable or refused surgery. Prior to ablation, transcatheter arterial embolization was performed using a mixture of absolute ethanol and iodized oil. All cryoablation procedures were performed percutaneously under computed tomography fluoroscopy guidance. The primary endpoint was safety, which was evaluated for adverse events using CTCAE version 4.0. The secondary endpoint was survival; overall survival, progression-free survival, and cancer-specific survival were calculated. RESULTS: From October 2013 to March 2016, 19 patients (mean age, 75 ± 13 years; 5 women, 14 men) were prospectively enrolled. The mean tumor diameter was 3.9 ± 0.7 (range 3.1-5.3) cm. Four grade 3 hematologic adverse events occurred, while no symptomatic grade ≥ 3 events occurred. The median follow-up period was 68 (range 52-84) months. During the follow-up period, two patients developed local tumor progression at 3 and 42 months after the initial ablative procedure; no patient showed distant metastasis. Two patients died from causes other than RCC. Overall survival, progression-free survival, and cause-specific survival were 100%, 95%, and 100% at 3 years, and 95%, 84%, and 100% at 5 years, respectively. CONCLUSION: Percutaneous cryoablation combined with prior TAE for the treatment of tumors ≥ 3 cm in diameter was safe and achieved favorable survival.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Embolización Terapéutica , Neoplasias Renales , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/patología , Carcinoma de Células Renales/cirugía , Criocirugía/métodos , Etanol , Femenino , Humanos , Aceite Yodado , Neoplasias Renales/patología , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
2.
Int J Clin Oncol ; 26(3): 562-568, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33174078

RESUMEN

BACKGROUND: Percutaneous cryoablation is widely used for the treatment of renal cell carcinoma. We prospectively evaluated the oncologic outcomes and safety of percutaneous cryoablation for the treatment of tumors ≤ 4 cm in diameter. METHODS: We included patients aged ≥ 20 years, who had histologically proven renal cell carcinoma, tumor diameter ≤ 4 cm, a performance status of ≤ 1, acceptable laboratory parameters, were inoperable or refused to undergo surgery, and had signed a written informed consent. The primary endpoint was the cause-specific survival rate. The secondary endpoints were overall and progression-free survival, and adverse event frequency and grade. All procedures were percutaneously performed under computed tomography fluoroscopy guidance. RESULTS: From October 2013 to October 2015, 33 patients (mean age: 68 ± 14 years; sex: six women, 27 men) were enrolled. The mean tumor diameter was 2.1 ± 0.6 (range 1.0-3.4) cm. The median follow-up period was 60.1 (range 18.4-76.6) months. One patient died of non-renal cell carcinoma-related disease 46 months after percutaneous cryoablation. The cause-specific and overall survival rates were 100% and 96.8% at 3 years, and 100% and 96.8% at 5 years, respectively. There was no local tumor progression or distant metastasis. The incidence of severe urological (urinary fistula and perinephric infection) and non-urological adverse events (increased creatine kinase and skin ulceration) was 6% each. CONCLUSION: Percutaneous cryoablation for renal cell carcinoma ≤ 4 cm in diameter achieved good tumor control with a low complication frequency.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Neoplasias Renales , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Carcinoma de Células Renales/cirugía , Criocirugía/efectos adversos , Femenino , Humanos , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
3.
Acta Med Okayama ; 75(1): 9-14, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33649608

RESUMEN

To assess the feasibility of needle tract ablation in liver tissue in ex vivo and in vivo animal models using a cryo-probe and electrosurgical device. The experimental device is made by inserting a cryoprobe through an intro-ducer sheath for insulation, with 2-cm of probe tip projecting out. A beagle liver was punctured by the device, and electric current was applied at 30-W with the electrosurgical knife touching the non-insulated device base. The discolored area of cut surface along the device was evaluated in 5 application-time groups (5 , 10 , 15 , 20, or 25 seconds). An ex vivo experiment was performed to determine an ablation algorithm with an appropriate application time by comparison with radiofrequency ablation (RFA) results. Thereafter, an in vivo experiment was performed to verify the algorithm's feasibility. In the ex vivo model, the cut surface demonstrated different amounts of discolored area according to the application time. The total discolored area in the 20-seconds group was similar to that by RFA. In the in vivo model, the liver did not bleed, the total discolored area was similar to that ex vivo, and coagulation necrosis was confirmed by photomicrograph. Needle tract ablation can be per-formed using the experimental device and electrosurgical device.


Asunto(s)
Ablación por Catéter/métodos , Electrocirugia/instrumentación , Hígado/cirugía , Animales , Perros , Femenino , Hemorragia/prevención & control , Hígado/patología , Agujas
4.
Eur Radiol ; 30(2): 927-933, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31444597

RESUMEN

INTRODUCTION: This was a prospective, first-in-human trial to evaluate the feasibility and safety of insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy in humans. MATERIALS AND METHODS: Eligible patients were adults with a lesion ≥ 10 mm in an extremity or the trunk requiring pathological diagnosis with CT fluoroscopy-guided biopsy. Patients in whom at-risk structures were located within 10 mm of the scheduled needle tract were excluded. Ten patients (4 females and 6 males; mean [range] age, 72 [52-87] years) with lesions (mean [range] maximum diameter, 28 [14-52] mm) in the kidney (n = 4), lung (n = 3), mediastinum (n = 1), adrenal gland (n = 1), and muscle (n = 1) were enrolled. The biopsy procedure involved robotic insertion of a biopsy introducer needle followed by manual acquisition of specimens using a biopsy needle. The patients were followed up for 14 days. Feasibility was defined as the distance of ≤ 10 mm between needle tip after insertion and the nearest lesion edge on the CT fluoroscopic images. The safety of robotic insertion was evaluated on the basis of machine-related troubles and adverse events according to the Clavien-Dindo classification. RESULTS: Robotic insertion of the introducer needle was feasible in all patients, enabling pathological diagnosis. There was no machine-related trouble. A total of 11 adverse events occurred in 8 patients, including 10 grade I events and 1 grade IIIa event. CONCLUSION: Insertion of biopsy introducer needles with our robot was feasible at several locations in the human body. KEY POINTS: • Insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy was feasible at several locations in the human body.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Radiografía Intervencional/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Adulto , Biopsia con Aguja/métodos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Humanos , Biopsia Guiada por Imagen/instrumentación , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Robótica/métodos , Tomografía Computarizada por Rayos X/métodos
5.
Eur Radiol ; 30(3): 1342-1349, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31773299

RESUMEN

OBJECTIVES: To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments. METHODS: A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student's t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center. RESULTS: In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively. CONCLUSION: Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion. KEY POINTS: • Out-of-plane needle insertions performed using our robot were more accurate than smartphone-guided manual insertions in the phantom experiment and were also accurate in the in vivo procedure. • In the phantom experiment, the mean angle errors of the robotic and smartphone-guided manual out-of-plane needle insertions were 0.4° and 3.7° in the XY plane (p < 0.001) and 0.6° and 0.6° in the YZ plane (p = 0.65), respectively. • In the animal experiment, the overall mean distance accuracies of the robotic out-of-plane needle insertions with and without adjustments of needle orientation during insertion were 2.5 mm and 5.0 mm, respectively.


Asunto(s)
Riñón/cirugía , Músculo Esquelético/cirugía , Agujas , Fantasmas de Imagen , Punciones/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Animales , Biopsia Guiada por Imagen/métodos , Riñón/patología , Músculo Esquelético/patología , Robótica/métodos , Teléfono Inteligente , Programas Informáticos , Cirugía Asistida por Computador/métodos , Porcinos , Tomografía Computarizada por Rayos X/métodos
6.
J Vasc Interv Radiol ; 31(7): 1044-1051, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32471699

RESUMEN

PURPOSE: To retrospectively compare the outcomes of radiofrequency (RF) ablation, stereotactic body radiotherapy (SBRT), and sublobar resection (SLR) in patients with stage I non-small-cell lung cancer (NSCLC) at a single center. MATERIALS AND METHODS: Overall, 289 patients (38 RF ablation, 58 SBRT, and 193 SLR) were included. Kaplan-Meier curves were generated, multiple propensity score was estimated using a multinomial logistic regression model, and relationships between treatments and outcomes were assessed using a Cox proportional hazard model. Hazard ratios (HRs) for death from any cause and disease progression or death from any cause were examined by a crude model, an inverse probability of treatment weighting (IPTW) model, and an IPTW model adjusted for missing variables. RESULTS: The 5-year overall and progression-free survival rates were 58.9% and 39.9%, respectively, for RF ablation; 42.0% and 34.9%, respectively, for SBRT; and 85.5% and 75.9%, respectively, for SLR. Significantly longer survival time and lower HR were observed for SLR than other treatments. However, after statistical adjustment, these relationships were not significant except for reduced HR of disease progression or death from any cause of SLR compared to RF ablation in the IPTW model. The median hospital stays for RF ablation, SBRT, and SLR were 6.5, 6, and 16 days, respectively. Adverse events of grade 3 or higher occurred only in 11 SLR cases. CONCLUSIONS: SLR achieved the longest survival. However, after statistical adjustment, there were no significant outcome differences among RF ablation, SBRT, and SLR, except for 1 model. RF ablation or SBRT may be alternative treatments for selected patients with early-stage NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/terapia , Neoplasias Pulmonares/terapia , Neumonectomía , Ablación por Radiofrecuencia , Radiocirugia , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/patología , Progresión de la Enfermedad , Femenino , Humanos , Japón , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neumonectomía/efectos adversos , Neumonectomía/mortalidad , Supervivencia sin Progresión , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/mortalidad , Radiocirugia/efectos adversos , Radiocirugia/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
7.
Acta Med Okayama ; 74(3): 209-214, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32577018

RESUMEN

An aspiration-type semi-automatic cutting biopsy needle enables tissue cutting during application of negative pressure, which is expected to contribute to a larger amount of specimen. The aim of the present study was to evaluate this novel needle in a clinical setting. Patients who underwent image-guided percutaneous biopsy for lung or renal masses were enrolled. Cutting biopsy was performed with and without aspiration during each procedure. The specimens were weighed using an electronic scale. The weights were compared between specimens obtained with and without aspiration using a paired t-test. The data from 45 lung and 30 renal biopsy procedures were analyzed. In lung biopsy, the mean±standard deviation weights of specimens obtained with and without aspiration were 2.20±1.05 mg and 2.24±1.08 mg, respectively. In renal biopsy, the mean weights were 6.52±2.18 mg and 6.42±1.62 mg, respectively. The weights were not significantly different between specimens obtained with and without aspiration either in lung (p=0.799) or renal (p=0.789) biopsies. The application of negative pressure with the aspiration-type semi-automatic cutting biopsy needle did not contribute to an increase in the amount of the specimen obtained in lung and renal biopsies.


Asunto(s)
Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/instrumentación , Riñón/patología , Pulmón/patología , Anciano , Biopsia con Aguja/efectos adversos , Estudios de Casos y Controles , Femenino , Humanos , Biopsia Guiada por Imagen/efectos adversos , Masculino , Memoria Episódica , Persona de Mediana Edad , Manejo de Especímenes/métodos , Tomografía Computarizada por Rayos X
8.
Eur Radiol ; 28(1): 283-290, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28770407

RESUMEN

OBJECTIVES: To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. METHODS: Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. RESULTS: After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CONCLUSION: CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. KEY POINTS: • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.


Asunto(s)
Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja/métodos , Femenino , Fluoroscopía/métodos , Humanos , Biopsia Guiada por Imagen , Riñón/diagnóstico por imagen , Riñón/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
9.
Artif Organs ; 42(8): E186-E203, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29633282

RESUMEN

Retinal prosthesis or artificial retina is a promising modality of treatment for outer retinal degeneration, caused by primary and secondary loss of photoreceptor cells, in hereditary retinal dystrophy and age-related macular degeneration, respectively. Okayama University-type retinal prosthesis (OUReP) is a photoelectric dye-coupled polyethylene film which generates electric potential in response to light and stimulates nearby neurons. The dye-coupled films were implanted by vitreous surgery in the subretinal space of monkey eyes with macular degeneration which had been induced by cobalt chloride injection from the scleral side. A pilot 1-month observation study involved 6 monkeys and a pivotal 6-month observation study involved 8 monkeys. Of 8 monkeys in 6-month group, 3 monkeys underwent dye-coupled film removal at 5 months and were observed further for 1 month. The amplitude of visual evoked potential which had been reduced by macular degeneration did recover at 1 month after film implantation and maintained the level at 6 months. Optical coherence tomography showed no retinal detachment, and full-field electroretinograms maintained a-wave and b-wave amplitudes, indicative of no retinal toxicity. Pathological examinations after 6-month implantation showed structural integrity of the inner retinal layer in close apposition to dye-coupled films. The implanted films which were removed by vitrectomy 5 months later showed light-evoked surface electric potentials by scanning Kelvin probe measurement. The photoelectric dye-coupled film (OUReP), which serves as a light-receiver and a displacement current generator in the subretinal space of the eye, has a potential for recovering vision in diseases with photoreceptor cell loss, such as retinitis pigmentosa and age-related macular degeneration.


Asunto(s)
Potenciales Evocados Visuales , Degeneración Macular/cirugía , Implantación de Prótesis/instrumentación , Retina/cirugía , Prótesis Visuales , Compuestos de Anilina/química , Compuestos de Anilina/efectos de la radiación , Animales , Modelos Animales de Enfermedad , Estudios de Factibilidad , Luz , Macaca fascicularis , Degeneración Macular/patología , Degeneración Macular/fisiopatología , Proyectos Piloto , Polietileno/química , Diseño de Prótesis , Recuperación de la Función , Retina/patología , Retina/fisiopatología , Propiedades de Superficie , Tiazoles/química , Tiazoles/efectos de la radiación , Factores de Tiempo
10.
Acta Med Okayama ; 72(6): 539-546, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30573907

RESUMEN

Since 2012, we have been developing a remote-controlled robotic system (Zerobot®) for needle insertion during computed tomography (CT)-guided interventional procedures, such as ablation, biopsy, and drainage. The system was designed via a collaboration between the medical and engineering departments at Okayama University, including various risk control features. It consists of a robot with 6 degrees of freedom that is manipulated using an operation interface to perform needle insertions under CT-guidance. The procedure includes robot positioning, needle targeting, and needle insertion. Phantom experiments have indicated that robotic insertion is equivalent in accuracy to manual insertion, without physician radiation exposure. Animal experiments have revealed that robotic insertion of biopsy introducer needles and various ablation needles is safe and accurate in vivo. The first in vivo human trial, therefore, began in April 2018. After its completion, a larger clinical study will be conducted for commercialization of the robot. This robotic procedure has many potential advantages over a manual procedure: 1) decreased physician fatigue; 2) stable and accurate needle posture without tremor; 3) procedure automation; 4) less experience required for proficiency in needle insertion skills; 5) decreased variance in technical skills among physicians; and 6) increased likelihood of performing the procedure at remote hospitals (i.e., telemedicine).


Asunto(s)
Radiología Intervencionista/instrumentación , Procedimientos Quirúrgicos Robotizados/instrumentación , Robótica , Tomografía Computarizada por Rayos X , Humanos , Agujas , Radiología Intervencionista/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Universidades
11.
J Clin Biochem Nutr ; 63(2): 154-163, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30279628

RESUMEN

To investigate sex differences in the associations among metabolic syndrome, obesity, adipose tissue-related biomarkers, and colorectal adenomatous polyps, a cross-sectional, multicenter study was conducted on 489 consecutive individuals who underwent their first colonoscopy at 3 hospitals. Plasma concentrations of adiponectin and leptin, as well as homeostatic model assessment of insulin resistance were also evaluated. The presence and number of adenomatous polyps, including advanced adenoma, were higher in men than in women. Metabolic syndrome was a risk factor for adenomatous polyps in both sexes. Large waist circumference was an independent risk factor for adenomatous polyps in men, and high BMI and large waist circumference were risk factors for adenomatous polyps in women. Interestingly, low BMI was associated with large adenomatous polyps (≥10 mm) and advanced adenoma, and waist-hip ratio was involved in proximal adenomatous polyp development only in women. In contrast, the highest quartile of leptin concentration had a 3.67-fold increased adenomatous polyp risk compared with the lowest quartile only in men. These results indicate that regarding colorectal pathogenesis, sex differences were identified in obesity but not in metabolic syndrome. Visceral obesity and a high serum leptin level may be risk factors for colorectal adenomatous polyp development in Japanese men.

12.
Radiology ; 285(2): 454-461, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28604237

RESUMEN

Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 µSv, while that during manual insertion was 5.7 µSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Agujas , Radiografía Intervencional/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Diseño de Equipo , Fantasmas de Imagen , Radiografía Intervencional/instrumentación , Procedimientos Quirúrgicos Robotizados/instrumentación , Porcinos , Tomografía Computarizada por Rayos X/instrumentación
13.
J Vasc Interv Radiol ; 28(6): 869-876, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28366658

RESUMEN

PURPOSE: To retrospectively evaluate the effect of cryoablation of renal-cell carcinoma on nearby renal cysts with the goal to investigate the potential for an alternative therapy to treat symptomatic renal cysts. MATERIALS AND METHODS: The study population comprised 46 cysts (mean size, 12 mm; range, 5-43 mm) that were within or near the ice ball during cryoablation in 22 patients. Size change of each cyst was evaluated via enhanced CT or MR imaging before and 1, 3, 6, and 12 months after cryoablation. Forty-one cysts were also followed after 12 months. Variables including positional relationship between the cyst and the ice ball were evaluated via linear regression analysis using generalized estimating equation models to determine which factors affected cyst shrinkage rate at 12 months. RESULTS: Fifteen, 12, and 19 cysts were completely included in, partially included in, or excluded from the ice ball, respectively. The overall shrinkage rate was 62%, and 57% of cysts (26 of 46) had disappeared at 12 months. Only the relationship between the cyst and the ice ball was significantly (P < .001) associated with cyst shrinkage rate. Cyst disappearance rates at 12 months were 100% (15 of 15), 67% (8 of 12), and 16% (3 of 19) for cysts completely included, partially included, and excluded from the ice ball, respectively. Among the 22 cysts that disappeared at 12 months and continued to be followed, none recurred after 12 months. CONCLUSIONS: All renal cysts that were completely included in the ice ball disappeared after cryoablation, demonstrating the potential utility of cryoablation as an alternative therapy for symptomatic renal cysts.


Asunto(s)
Carcinoma de Células Renales/cirugía , Criocirugía/métodos , Quistes/cirugía , Neoplasias Renales/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Quistes/diagnóstico por imagen , Quistes/patología , Femenino , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
Minim Invasive Ther Allied Technol ; 26(2): 86-91, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27750475

RESUMEN

PURPOSE: To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. MATERIAL AND METHODS: Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. RESULTS: After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). CONCLUSIONS: Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.


Asunto(s)
Biopsia con Aguja/métodos , Criocirugía/métodos , Neoplasias Renales/diagnóstico , Procedimientos Innecesarios , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja/efectos adversos , Femenino , Humanos , Neoplasias Renales/patología , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Biochim Biophys Acta ; 1850(11): 2159-67, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26299247

RESUMEN

BACKGROUND: Clostridium perfringens beta-toxin is a pore-forming toxin (PFT) and an important agent of necrotic enteritis and enterotoxemia. We recently reported that beta-toxin strongly induced cell death in THP-1 cells via the formation of oligomers. We here describe that the P2X(7) receptor, which is an ATP receptor, interacts with beta-toxin. METHODS: We tested the role of P2X(7) receptor in beta-toxin-induced toxicity using specific inhibitors, knockdown of receptor, expression of the receptor and interaction by dot-blot assay. The potency of P2X(7) receptor was further determined using an in vivo mouse model. RESULTS: Selective P2X(7) receptor antagonists (oxidized ATP (o-ATP), oxidized ADP, and Brilliant Blue G (BBG)) inhibited beta-toxin-induced cytotoxicity in THP-1 cells. o-ATP also blocked the binding of beta-toxin to cells. The P2X(7) receptor and beta-toxin oligomer were localized in the lipid rafts of THP-1 cells. siRNA for the P2X(7) receptor inhibited toxin-induced cytotoxicity and binding of the toxin. In contrast, the siRNA knockdown of P2Y(2) or P2Y(6) had no effect on beta-toxin-induced cytotoxicity. The addition of beta-toxin to P2X(7)-transfected HEK-293 cells resulted in binding of beta-toxin oligomer. Moreover, beta-toxin specifically bound to immobilized P2X(7) receptors in vitro and colocalized with the P2X(7) receptor on the THP-1 cell surface. Furthermore, beta-toxin-induced lethality in mice was blocked by the preadministration of BBG. CONCLUSIONS: The results of this study indicate that the P2X(7) receptor plays a role in beta-toxin-mediated cellular injury. GENERAL SIGNIFICANCE: P2X(7) receptor is a potential target for the treatment of C. perfringens type C infection.


Asunto(s)
Toxinas Bacterianas/toxicidad , Receptores Purinérgicos P2X7/fisiología , Proteínas ADAM/fisiología , Proteína ADAM10 , Secretasas de la Proteína Precursora del Amiloide/fisiología , Animales , Calcio/metabolismo , Células HEK293 , Humanos , Proteínas de la Membrana/fisiología , Ratones , Ratones Endogámicos ICR , ARN Interferente Pequeño/farmacología , Colorantes de Rosanilina/farmacología
16.
J Immunol ; 193(9): 4507-14, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25261480

RESUMEN

Vizantin has immunostimulating properties and anticancer activity. In this study, we investigated the molecular mechanism of immune activation by vizantin. THP-1 cells treated with small interfering RNA for TLR-4 abolished vizantin-induced macrophage activation processes such as chemokine release. In addition, compared with wild-type mice, the release of MIP-1ß induced by vizantin in vivo was significantly decreased in TLR-4 knockout mice, but not in TLR-2 knockout mice. Vizantin induced the release of IL-8 when HEK293T cells were transiently cotransfected with TLR-4 and MD-2, but not when they were transfected with TLR-4 or MD-2 alone or with TLR-2 or TLR-2/MD-2. A dipyrromethene boron difluoride-conjugated vizantin colocalized with TLR-4/MD-2, but not with TLR-4 or MD-2 alone. A pull-down assay with vizantin-coated magnetic beads showed that vizantin bound to TLR-4/MD-2 in extracts from HEK293T cells expressing both TLR-4 and MD-2. Furthermore, vizantin blocked the LPS-induced release of TNF-α and IL-1ß and inhibited death in mice. We also performed in silico docking simulation analysis of vizantin and MD-2 based on the structure of MD-2 complexed with the LPS antagonist E5564; the results suggested that vizantin could bind to the active pocket of MD-2. Our observations show that vizantin specifically binds to the TLR-4/MD-2 complex and that the vizantin receptor is identical to the LPS receptor. We conclude that vizantin could be an effective adjuvant and a therapeutic agent in the treatment of infectious diseases and the endotoxin shock caused by LPS.


Asunto(s)
Endotoxinas/inmunología , Glucolípidos/farmacología , Inmunidad/efectos de los fármacos , Antígeno 96 de los Linfocitos/metabolismo , Trehalosa/análogos & derivados , Animales , Quimiocina CCL4/biosíntesis , Citocinas/biosíntesis , Expresión Génica , Glucolípidos/metabolismo , Células HEK293 , Humanos , Inmunidad/genética , Mediadores de Inflamación/metabolismo , Lipopolisacáridos/inmunología , Lipopolisacáridos/farmacología , Antígeno 96 de los Linfocitos/química , Antígeno 96 de los Linfocitos/genética , Macrófagos/química , Macrófagos/efectos de los fármacos , Macrófagos/inmunología , Macrófagos/metabolismo , Ratones , Ratones Noqueados , Modelos Moleculares , Unión Proteica , Conformación Proteica , Transporte de Proteínas , Receptor Toll-Like 4/genética , Receptor Toll-Like 4/metabolismo , Trehalosa/metabolismo , Trehalosa/farmacología
17.
Dig Dis Sci ; 61(6): 1641-51, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26423081

RESUMEN

BACKGROUND: Previous morphological studies indicated that the eradication of Helicobacter pylori (H. pylori) made gastric neoplasms endoscopically indistinct through the flattening and covering of tumors with a non-neoplastic epithelium (NE). AIM: To validate these alterations. METHODS: We reviewed and compared the endoscopic and histological findings of early gastric carcinomas and high-grade dysplasias resected endoscopically from H. pylori-infected and H. pylori-eradicated patients. The extent of NE covering a tumor was expressed as the histological length ratio of NE to the tumor. Tumor morphology was compared before and after therapies in patients who received H. pylori eradication treatments during the period from tumor discovery to endoscopic resection. RESULTS: NE-covered ratios were higher in the 59 tumors detected after the eradication of H. pylori than in the 152 tumors detected during the infection (median 8 vs. 0 %, respectively), whereas the frequency at which an elevated morphology and whitish discoloration of a tumor were observed was less (14 vs. 56 %, and 14 vs. 43 %, respectively). These were also independent characteristics for tumors detected after the eradication of H. pylori. Two elevated tumors showing whitish discoloration out of 16 tumors became endoscopically indistinct following H. pylori eradication treatments through the flattening of tumors and muting of the discoloration. CONCLUSION: The eradication of H. pylori promoted covering with NE, the flattening of tumors, and muting of the whitish discoloration, which may make a subset of tumors, potentially including whitish elevated neoplasms, indistinct.


Asunto(s)
Infecciones por Helicobacter/tratamiento farmacológico , Helicobacter pylori , Neoplasias Gástricas/patología , Endoscopía Gastrointestinal , Infecciones por Helicobacter/microbiología , Humanos , Estudios Retrospectivos , Factores de Riesgo
18.
Proc Natl Acad Sci U S A ; 110(11): 4267-72, 2013 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-23382240

RESUMEN

Clostridium perfringens iota-toxin (Ia) mono-ADP ribosylates Arg177 of actin, leading to cytoskeletal disorganization and cell death. To fully understand the reaction mechanism of arginine-specific mono-ADP ribosyl transferase, the structure of the toxin-substrate protein complex must be characterized. Recently, we solved the crystal structure of Ia in complex with actin and the nonhydrolyzable NAD(+) analog ßTAD (thiazole-4-carboxamide adenine dinucleotide); however, the structures of the NAD(+)-bound form (NAD(+)-Ia-actin) and the ADP ribosylated form [Ia-ADP ribosylated (ADPR)-actin] remain unclear. Accidentally, we found that ethylene glycol as cryo-protectant inhibits ADP ribosylation and crystallized the NAD(+)-Ia-actin complex. Here we report high-resolution structures of NAD(+)-Ia-actin and Ia-ADPR-actin obtained by soaking apo-Ia-actin crystal with NAD(+) under different conditions. The structures of NAD(+)-Ia-actin and Ia-ADPR-actin represent the pre- and postreaction states, respectively. By assigning the ßTAD-Ia-actin structure to the transition state, the strain-alleviation model of ADP ribosylation, which we proposed previously, is experimentally confirmed and improved. Moreover, this reaction mechanism appears to be applicable not only to Ia but also to other ADP ribosyltransferases.


Asunto(s)
ADP Ribosa Transferasas/química , Actinas/química , Toxinas Bacterianas/química , Clostridium perfringens/enzimología , NAD/química , Procesamiento Proteico-Postraduccional , ADP Ribosa Transferasas/metabolismo , Actinas/metabolismo , Toxinas Bacterianas/metabolismo , NAD/análogos & derivados , NAD/metabolismo , Estructura Cuaternaria de Proteína , Estructura Terciaria de Proteína
19.
Acta Med Okayama ; 70(4): 303-6, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27549678

RESUMEN

This single center prospective study is being conducted to evaluate the safety of the cryoablation for patients with pathologically diagnosed painful bone and soft tissue tumors. Enrollment of 10 patients is planned over the 3-year recruitment period. Patients have related local pain after receiving medications or external radiation therapies will be included in this study. Cryoablation will be percutaneously performed under imaging guidance, and a temperature sensor will be used during treatment as necessary. The primary endpoint is prevalence of severe adverse events within 4 weeks after therapy. The secondary endpoint is effectiveness 4 weeks after the procedure.


Asunto(s)
Neoplasias Óseas/complicaciones , Criocirugía/efectos adversos , Dolor/etiología , Neoplasias de los Tejidos Blandos/complicaciones , Protocolos Clínicos , Humanos , Manejo del Dolor , Proyectos de Investigación
20.
Acta Med Okayama ; 70(4): 317-21, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27549681

RESUMEN

The present single center prospective phase II clinical trial is designed to evaluate the efficacy and safety of percutaneous radiofrequency (RF) ablation for colorectal lung metastases. Patients who have colorectal lung metastases without extrapulmonary metastases are included in this study. The primary endpoint is 3-year overall survival (OS) after RF ablation. The secondary endpoints are the prevalence of adverse events within 4 weeks, local tumor progression rate, 1- and 5-year OS, cause-specific survival, and relapse-free survival. The recruitment of patients commenced in July 2014, and the enrolment of 45 patients is intended over the 3 years of study period.


Asunto(s)
Ablación por Catéter/métodos , Neoplasias Colorrectales/patología , Neoplasias Pulmonares/secundario , Técnicas de Ablación , Protocolos Clínicos , Ensayos Clínicos Fase II como Asunto , Humanos , Neoplasias Pulmonares/terapia , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA