Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 260(4): 1183-1193, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34779906

RESUMEN

PURPOSE: This study aimed to assess the differences in blinking kinematics while reading on different digital displays and a control condition. METHODS: Thirty-two young healthy individuals were included in this prospective clinical study. The blinks of subjects were recorded for 150 s while reading on a laptop computer, tablet, e-reader, and smartphone and a control condition. Blinks were recorded using an eye-tracking device and were analyzed by means of image analysis to obtain a non-invasive detailed description of the blink movement. RESULTS: Blink rate decreased when reading on all displays compared to the control (p < 0.0005), although no differences were obtained amongst displays (p > 0.05). The percentage of incomplete blinks was higher with the computer compared to the control (p = 0.043), and lower with the smartphone compared to the rest of the conditions (p ≤ 0.015). Blink amplitude was smaller when reading from handheld devices compared to the control (p < 0.0005) and the computer (p ≤ 0.048). Closing and opening blink durations remained unvaried amongst conditions (p > 0.05), while opening and closing speeds were greater for the control and the computer compared to the handheld displays (p < 0.0005). Finally, contact and total blink durations were shorter during computer reading compared to the control (p = 0.004 and p = 0.017, respectively). CONCLUSION: Blinking kinematics vary considerably amongst displays and with respect to baseline, with these differences being probably attributed to differences in the way the displays are set up and the cognitive demand of the task.


Asunto(s)
Parpadeo , Computadores , Fenómenos Biomecánicos , Humanos , Estudios Prospectivos , Lectura
2.
Optom Vis Sci ; 97(12): 1070-1079, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33259378

RESUMEN

SIGNIFICANCE: Digital display use has been accepted as a contributing factor to dry eye disease. Nowadays, plenty of new models of digital displays have been developed, and the differences in their nature and the ways in which they are set and used may contribute to differences in the eye-related problems they cause. PURPOSE: This study aimed to analyze the differences in ocular surface, tear film, and visual fatigue parameters after reading on different digital displays, with and without initial instillation of artificial tears. METHODS: Thirty-one healthy individuals ranging in age from 20 to 26 years (mean ± standard deviation, 21.26 ± 1.73 years) were included in this prospective clinical study. Subjects' ocular surface, tear film, and visual fatigue parameters were assessed after reading for 15 minutes on a laptop computer, tablet, e-reader, and smartphone with matching characteristics and a baseline measurement. Measurements were taken with and without the instillation of artificial tears before the reading tasks and included the Ocular Surface Disease Index questionnaire, the Computer Vision Syndrome Questionnaire, tear meniscus height, the Schirmer I test, noninvasive keratograph break-up time, osmolarity, bulbar redness, and pupil size. RESULTS: Statistically significant differences in the Ocular Surface Disease Index, Computer Vision the Syndrome Questionnaire, tear meniscus height, the Schirmer I test, noninvasive keratograph break-up time, osmolarity, and bulbar redness were obtained when comparing the displays (P < .05). Best results were obtained with the smartphone and the e-reader. Conversely, the computer produced the highest disturbance on the ocular surface and tear film. Finally, the instillation of artificial tears revealed no statistical improvement of ocular surface or tear film parameters for the same device (P > .05). CONCLUSIONS: Taking into account the clinical tests for dry eye diagnosis, the smartphone may be considered as the least disturbing display, producing lower dry eye signs and symptoms in comparison with other devices.


Asunto(s)
Astenopía/fisiopatología , Computadoras de Mano , Síndromes de Ojo Seco/fisiopatología , Lectura , Lágrimas/fisiología , Adulto , Femenino , Humanos , Gotas Lubricantes para Ojos/administración & dosificación , Masculino , Concentración Osmolar , Estudios Prospectivos , Encuestas y Cuestionarios , Adulto Joven
3.
Arq Bras Oftalmol ; 77(4): 243-9, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25410177

RESUMEN

PURPOSE: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. METHODS: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained for various accommodation stimuli, ranging from +1 D to -4 D in 1-D steps. RESULTS: For a given position, the ACD did not vary significantly with accommodation. For the central ACD, the percentage of relative change between far and near vision was -4.11%. The ACA was significantly lower at the inferior, temporal, and superior positions. There was no change in the ACA of the whole eye and that of the nasal orientation. These two eye metrics were significantly lower in the superior-nasal than in the inferior-temporal region. At each vergence studied, the PD decreased significantly with accommodation. The relative change after the -4 D stimulus was -8.13%. CONCLUSION: ACA and PD varied significantly with accommodation, whereas no such variation of ACD was observed. Further, the anterior chamber was found to be asymmetrical, with the nasal-superior area becoming significantly shallower than the inferior temporal region.


Asunto(s)
Acomodación Ocular/fisiología , Cámara Anterior/anatomía & histología , Iris/anatomía & histología , Tomografía de Coherencia Óptica/instrumentación , Adulto , Técnicas de Diagnóstico Oftalmológico , Femenino , Humanos , Iris/fisiología , Masculino , Fotograbar/instrumentación , Pupila/fisiología , Adulto Joven
4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(4): 243-249, Jul-Aug/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-728661

RESUMEN

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained for various accommodation stimuli, ranging from +1 D to -4 D in 1-D steps. Results: For a given position, the ACD did not vary significantly with accommodation. For the central ACD, the percentage of relative change between far and near vision was -4.11%. The ACA was significantly lower at the inferior, temporal, and superior positions. There was no change in the ACA of the whole eye and that of the nasal orientation. These two eye metrics were significantly lower in the superior-nasal than in the inferior-temporal region. At each vergence studied, the PD decreased significantly with accommodation. The relative change after the -4 D stimulus was -8.13%. Conclusion: ACA and PD varied significantly with accommodation, whereas no such variation of ACD was observed. Further, the anterior chamber was found to be asymmetrical, with the nasal-superior area becoming significantly shallower than the inferior temporal region. .


Objetivo: Estudar as mudanças na profundidade da câmara anterior (ACD), ângulo da câmara anterior (ACA) e diâmetro da pupila (PD) durante a acomodação. Métodos: Foram incluídos 80 olhos de 80 indivíduos com idades entre 22 e 40 anos. Um sistema rotacional de Scheimpflug duplo acoplado a um sistema de disco de Placido (Galilei G4, Ziemer Ophthalmic Systems AG, Suíça) foi usado para medir as mudanças na ACD, ACA e PD, durante a acomodação. As medidas da ACD foram consideradas na zona central e em mais 4 posições, cada uma em orientação diferente (nasal, superior, temporal e inferior), a 4 milímetros de distância do centro. O ACA do olho inteiro, assim como nos quadrantes nasal, superior, temporal e inferior foram medidos. Todos estes indicadores foram obtidos por vários estímulos acomodativos, que variaram de +1 D a -4 D em intervalos de 1 D. Resultados: A ACD não variou significativamente com acomodação para qualquer determinada orientação, sendo a percentagem de variação relativa entre longe e visão de perto -4,11% para a ACD central (onde sinal negativo representa uma diminuição na ACD). Em relação ao ACA, este diminuiu significativamente em posições inferiores, temporais e superiores. O ACA total de olho e o ACA nasal não se alterou. Estas duas métricas oculares foram significativamente menores no par nasal-superior do que no temporal-inferior. Finalmente, PD diminuiu significativamente com a acomodação em cada vergência estudada, a mudança relativa após o estímulo de -4 D foi -8,13%. Conclusão: ACA e PD variaram significativamente com a acomodação, enquanto ACD não. Além disso, a câmara anterior se mostrou alterar assimetricamente, com a área nasal-superior se tornando ...


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Adulto Joven , Acomodación Ocular/fisiología , Cámara Anterior/anatomía & histología , Iris/anatomía & histología , Tomografía de Coherencia Óptica/instrumentación , Técnicas de Diagnóstico Oftalmológico , Iris/fisiología , Fotograbar/instrumentación , Pupila/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA