Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 142(11): 1974-1981, 2017 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-28504795

RESUMEN

A miniaturized, robust, localized surface plasmon resonance (LSPR)-coupled fiber-optic (FO) nanoprobe providing an integrated and portable solution for detection of DNA hybridization and measurement of DNA concentrations has been demonstrated. The FO nanoprobe was created by constructing arrays of metallic nanostructures on the end facets of optical fibers utilizing nanofabrication technologies, including electron beam lithography and lift-off processes. The LSPR-FO nanoprobe device offers real-time, label-free, and low-sample-volume quantification of single-strand DNA in water with high sensitivity and selectivity, achieving a limit of detection around 10 fM. These results demonstrate the feasibility of the LSPR-FO nanoprobe device as a compact and low-cost biosensor for detection of short-strand DNA.


Asunto(s)
Técnicas Biosensibles , ADN/análisis , Tecnología de Fibra Óptica , Nanoestructuras , Resonancia por Plasmón de Superficie , Fibras Ópticas
2.
Biosens Bioelectron ; 61: 95-101, 2014 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-24858997

RESUMEN

A miniaturized, localized surface plasmon resonance (LSPR)-coupled fiber-optic (FO) nanoprobe is reported as a biosensor that is capable of label-free, sensitive detection of a cancer protein biomarker, free prostate specific antigen (f-PSA). The biosensor is based on the LSPR at the reusable dielectric-metallic hybrid interface with a robust, gold nano-disk array at the fiber end facet that is directly fabricated using EBL and metal lift-off process. The f-PSA has been detected with a mouse anti-human PSA monoclonal antibody (mAb) as a specific receptor linked with a self-assembled monolayer at the LSPR-FO facet surfaces. Experimental investigation and data analysis found near field refractive index (RI) sensitivity at ~226 nm/RIU with current LSPR-FO nanoprobe, and demonstrated the lowest limit of detection (LOD) at 100 fg/mL (~3 fM) of f-PSA in PBS solutions. The control experimentation using 5mg/mL bovine serum albumin in PBS and nonspecific surface test shows the excellent specificity and selectivity in the detection of f-PSA in PBS. These results present important progress towards a miniaturized, multifunctional fiber-optic technology that integrates informational communication and sensing function for developing a high performance, label-free, point-of-care (POC) device.


Asunto(s)
Tecnología de Fibra Óptica/instrumentación , Antígeno Prostático Específico/análisis , Resonancia por Plasmón de Superficie/instrumentación , Diseño de Equipo , Oro/química , Humanos , Límite de Detección , Nanoestructuras/química , Sistemas de Atención de Punto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA