Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 48(5): 559-566, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38400624

RESUMEN

BACKGOUND: Infections of the left ventricular assist device (LVAD) driveline are a dreaded complication that results in high mortality and morbidity. METHOD: We retrospectively reviewed five consecutive patients with severe continuous-flow LVAD (HVAD, Heartmate 2, and Heartmate 3) driveline infection. These infections, which developed on an average of 960.4 ± 843.9 days after LVAD placement, were refractory to systemic antibiotics and local wound care. All were treated with extensive surgical debridement, local installation of absorbable antibiotic-loaded calcium sulfate beads (vancomycin and tobramycin), primary wound closure, and 6 weeks of systemic antibiotics after surgery. RESULTS: Four patients had resolution of DLI, and one had a recurrent infection at another part of the driveline 7 months after the complete resolution of the previous site. This patient was successfully treated with debridement and bead placements. Three patients still have their LVADs, while two received orthotopic heart transplants. At the time of the transplant, there was no evidence of gross infection of the LVAD drivelines or pumps. At the average follow-up time of 425.8 ± 151 days, no patients have an active infection. CONCLUSION: Treatment of LVAD driveline infection with absorbable antibiotic beads with primary wound closure is a viable option and merits further investigation.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Infecciones Relacionadas con Prótesis , Humanos , Antibacterianos/uso terapéutico , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Vancomicina , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía
2.
Can J Anaesth ; 71(3): 422-430, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38286981

RESUMEN

PURPOSE: Obtaining an objective, reproducible, and accurate assessment of volume status is one of the more difficult tasks in the perioperative arena. Since its advent in 2020, the Venous Excess Ultrasound (VExUS) score has gained popularity in the minimally invasive assessment of venous congestion. The VExUS exam has been well described as an additional series of images (hepatic vein, portal vein, and intrarenal vein) obtained with a phased-array probe during a transthoracic echocardiogram. Nevertheless, there are no descriptions of comprehensive VExUS exams performed using transesophageal echocardiography (TEE)-a modality that is routinely employed in patients undergoing cardiac surgery. CLINICAL FEATURES: We describe techniques to acquire and interpret a comprehensive TEE-supported VexUS exam, which may be used to optimize the perioperative care of cardiac surgical patients. CONCLUSION: Given the risks of fluid overload in critically ill cardiac surgery patients, TEE-supported VExUS examination may be a way to reduce morbidity in this population.


RéSUMé: OBJECTIF: L'obtention d'une évaluation objective, reproductible et précise du statut volémique est l'une des tâches les plus difficiles dans l'arène périopératoire. Depuis son introduction en 2020, le score VExUS (pour Venous Excess Ultrasound, soit échographie de l'excès veineux) a gagné en popularité dans l'évaluation minimalement invasive de la congestion veineuse. L'examen échographique VExUS a été bien décrit en tant que série supplémentaire d'images (veine hépatique, veine porte et veine intrarénale) obtenues à l'aide d'une sonde type « phased-array ¼ lors d'un échocardiogramme transthoracique. Néanmoins, il n'existe aucune description d'examens VExUS complets réalisés à l'aide d'une sonde d'ETO (échocardiographie transœsophagienne), une modalité couramment utilisée chez les patient·es bénéficiant d'une chirurgie cardiaque. CARACTéRISTIQUES CLINIQUES: Nous décrivons des techniques permettant d'acquérir et d'interpréter un examen VexUS complet par ETO, qui peut être utilisé pour optimiser les soins périopératoires de la patientèle en chirurgie cardiaque. CONCLUSION: Compte tenu des risques de surcharge hydrique chez la patientèle gravement malade en chirurgie cardiaque, l'examen VExUS basé sur l'ETO peut être un moyen de réduire la morbidité dans cette population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Corazón , Atención Perioperativa/métodos , Venas
3.
Crit Care Med ; 51(11): 1461-1468, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37378470

RESUMEN

OBJECTIVES: To evaluate the 30-day postoperative mortality and palliative care consultations in patients that underwent surgical procedures in the United States before and after Medicare Access and Children's Health Insurance Program Reauthorization Act (MACRA) implementation. DESIGN: Retrospective, Observational cohort study. SETTING: Secondary data were collected from the U.S. National Inpatient Sample, the largest hospital database in the country. The time span was from 2011 to 2019. PATIENTS: Adult patients that electively underwent 1 of 19 major procedures. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary outcome was cumulative postoperative mortality in two study cohorts. The secondary outcome was palliative care use. We identified 4,900,451 patients and categorized them into two study cohorts: PreM: 2011-2014 ( n = 2,103,836) and PostM: 2016-2019 ( n = 2,796,615). Regression discontinuity estimates and multivariate analysis were used. Across all procedures, 149,372 patients (7.1%) and 156,610 patients (5%) died within 30 days of their index procedures in the PreM and PostM cohorts, respectively. There was no statistically significant increase in mortality rates around postoperative day (POD) 30 (POD 26-30 vs 31-35) for both cohorts. More patients had inpatient palliative consultations during POD 31-60 compared with POD 1-30 in PreM (8,533 of 2,081,207 patients [0.4%] vs 1,118 of 22,629 patients [4.9%]) and PostM (18,915 of 2,791,712 patients [0.7%] vs 417 of 4,903 patients [8.5%]). Patients were more likely to receive palliative care consultations during POD 31-60 compared with POD 1-30 in both the PreM (odds ratio [OR] 5.31; 95% CI, 2.22-8.68; p < 0.001) and the PostM (OR 7.84; 95% CI, 4.83-9.10; p < 0.001) cohorts. CONCLUSIONS: We did not observe an increase in postoperative mortality after POD 30 before or after MACRA implementation. However, palliative care use markedly increased after POD 30. These findings should be considered hypothesis-generating because of several confounders.


Asunto(s)
Programa de Seguro de Salud Infantil , Cuidados Paliativos , Anciano , Adulto , Niño , Humanos , Estados Unidos , Medicare , Estudios Retrospectivos , Políticas , Derivación y Consulta , Cuidados Críticos
4.
Clin Transplant ; 36(8): e14707, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35543679

RESUMEN

INTRODUCTION: The present study aimed to compare the clinical outcomes of heart transplant patients whose donor hearts were preserved with the SherpaPak controlled cold organ system versus the conventional ice storage technique. METHODS: All patients undergoing heart transplantation at our center between January 2019 and April 2021 were divided into two groups according to the technique used during donor heart preservation and transport. The first group consisted of 34 SherpaPak controlled temperature preservation patients, and the second group consisted of 47 patients where the conventional three bags and ice technique was utilized during organ transportation. The two groups were compared based on demographics, operative details, and postoperative outcomes. RESULTS: There were no significant differences between the groups regarding Vasoactive Inotropic Score (VIS), Primary Graft Dysfunction (PGD), and the need for a transient pacer. However, the VIS, PGD, and pacing trends were lower in the SherpaPak patients even though the total ischemic and cardiopulmonary bypass times were significantly longer. Furthermore, SherpaPak patients exhibited a shorter stay in the ICU with no severe PGD and mortality. CONCLUSION: The SherpaPak donor heart preservation provides safe outcomes in heart transplant patients. Further research is needed to utilize this method for longer durations of ischemic time and expand travel distances for organ transportation.


Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Criopreservación , Corazón , Humanos , Hielo , Preservación de Órganos/métodos
5.
J Card Surg ; 37(7): 2209-2211, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35438821

RESUMEN

The severe shortage of donor's hearts has increased the mortality of patients on the transplant waiting list. However, donor hearts with valvular dysfunction are rarely used. Utilizing donor hearts with valvular lesions that can be repaired or replaced at the time of transplant will decrease waitlist mortality and offer many patients a second chance in life.


Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Humanos , Listas de Espera
6.
J Card Surg ; 37(12): 5646-5648, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36229938

RESUMEN

BACKGROUND: Donation after circulatory death is the donation after cardiac arrest. This technique has been employed and adopted by clinicians to overcome the shortage of available hearts for transplant. Warm ischemia time plays a pivotal role in the survival outcome of the heart recipients. AIM OF THE STUDY: To assess the efficacy of using the Foley catheter to flush the heart during procurement from donation after circulatory death donors. METHODS: We utilized a 2-WAY Foley catheter to flush the heart during procurement. The catheter was prepared and modified on the back table. RESULTS: We were successfully able to flush the heart within 3 minutes from skin incision with a good recipient outcome. CONCLUSIONS: Using the Foley catheter to flush the heart during recovery from donation after circulatory death donors was both efficient and fast.


Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Humanos , Donantes de Tejidos , Trasplante de Corazón/métodos , Corazón , Isquemia Tibia/métodos , Muerte
7.
J Card Surg ; 37(4): 732-738, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35060167

RESUMEN

BACKGROUND: We aimed to investigate the short-term outcomes of heart transplant patients who underwent SherpaPak™ donor organ preservation. METHOD: We prospectively collected the data of patients who underwent heart transplantation using SherpaPak™ system for donor organ transportation from February 2020 to March 2021. Donor and recipient demographic data, preoperative and postoperative echocardiographic and hemodynamic parameters, total ischemic time and SherpaPak temperatures, vasoactive inotropic scores (VIS), primary graft dysfunction (PGD) status, intensive care unit stay, complications, and mortality during follow-up were assessed. RESULTS: A total of 39 consecutive heart transplant patients with SherpaPak system were included in the study. The mean donor age was 32.2 ± 6.7 (range: 16-46). The mean recipient age was 57.5 ± 12 (range: 19-73). The mean preoperative ejection fraction (EF) was 23.7 ± 15.4 (range: 5-75). All recipients underwent a standard bicaval technique for orthotopic heart implantation. The mean total ischemic time was 230.1 ± 41 (range: 149-342) min. The mean Sherpa temperature was 5.6 ± 0.8°C (range: 3.7-7.5). The mean VIS was 10.2 ± 6.5 (range: 2-32). The number of mild PGD was 5 (14.7%), and moderate PGD was 4 (11.8%). There was no severe PGD. The postoperative EF was 64.3 ± 5.5 (range: 50-78). Mean intubation time was 47.4 ± 64 (range: 8-312, median: 22) h. The mean time of intensive care unit stay was 6.3 ± 5 (range: 2-31, median: 5) days. Two patients required chest revision (5.8%), two patients had lung infection (5.8%). Two patients had a stroke (5.8%). There was no mortality. CONCLUSION: Using the SherpaPak system during heart transplantation is safe and not associated with significant recipient morbidity. None of the recipients experienced significant PGD and mortality.


Asunto(s)
Trasplante de Corazón , Disfunción Primaria del Injerto , Trasplante de Corazón/efectos adversos , Humanos , Preservación de Órganos , Disfunción Primaria del Injerto/etiología , Disfunción Primaria del Injerto/prevención & control , Estudios Retrospectivos , Temperatura , Donantes de Tejidos
8.
J Card Surg ; 36(8): 3000-3002, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33993532

RESUMEN

The surgical treatment of pulmonary hypertension (PH), with or without pulmonary artery aneurysm, has evolved during the last 40 years from heart-lung transplants to bilateral lung transplants as the treatment of choice for PH patients with preserved right and left ventricular function and without complex cardiac abnomalies.


Asunto(s)
Aneurisma , Hipertensión Pulmonar , Trasplante de Pulmón , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Humanos , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/cirugía , Pulmón , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía
9.
Echocardiography ; 37(9): 1509-1511, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32856338

RESUMEN

Left ventricular pseudoaneurysm formation is a rare complication of transapical approach transcatheter aortic valve replacement. It can cause chest pain and shortness of breath or remain asymptomatic. Mortality rate is high, and therefore, timely diagnosis and management are essential. Different imaging modalities can provide anatomic or functional information and are essential for the primary diagnosis or during follow-up.


Asunto(s)
Aneurisma Falso , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Imagen Multimodal , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
J Card Surg ; 35(12): 3409-3411, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32985721

RESUMEN

Congestive heart failure is highly prevalent in the elderly population and left ventricular assist device (LVAD) has been increasingly used in this population. LVAD therapy is more costly than medical treatment but it increases the survival and quality of life of the elderly patients with low disease acuity. Therefore careful selection of candidates and implementation of LVAD therapy earlier in the course of the disease is crucial to improve outcomes. With the technical advances and improvement in clinical management, the financial burden of LVAD therapy in the elderly will become less, making this therapy more economically feasible.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Anciano , Insuficiencia Cardíaca/terapia , Humanos , Calidad de Vida
11.
J Card Surg ; 35(8): 2073-2076, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32652630

RESUMEN

BACKGROUND: Ventricular assist devices driveline infections are common, recalcitrant, and carry high morbidity and mortality. Herein, we reported a patient with driveline infection that was successfully treated with a combination of systemic antibiotics, surgical debridement, and instillation of absorbable antibiotic beads to the wound bed. METHODS AND RESULTS: A 39-year-old man with nonischemic cardiomyopathy underwent insertion of a continuous flow left ventricular assist device. Four years postoperatively, the patient presented with clinical, laboratory, and radiologic signs of driveline tract infection. He underwent extensive surgical debridement, installation of absorbable antibiotic beads that consisted of calcium sulfate, vancomycin, and tobramycin, into the wound bed, and systemic antibiotics. The patient was free of infection 9 month postoperatively. CONCLUSION: Absorbable calcium sulfate antibiotic beads may serve as a beneficial adjunct to surgical debridement and systemic antibiotics for the treatment of ventricular assist device driveline infection, and merit further investigation.


Asunto(s)
Antibacterianos/administración & dosificación , Cardiomiopatías/terapia , Quimioterapia Adyuvante/métodos , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Adulto , Sulfato de Calcio/administración & dosificación , Cefadroxilo/administración & dosificación , Cefazolina/administración & dosificación , Desbridamiento , Formas de Dosificación , Quimioterapia Combinada , Humanos , Masculino , Infecciones Relacionadas con Prótesis/microbiología , Staphylococcus aureus , Tobramicina/administración & dosificación , Resultado del Tratamiento , Vancomicina/administración & dosificación
12.
J Card Surg ; 35(12): 3560-3563, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32939826

RESUMEN

BACKGROUND: The use of extracorporeal circulation (ECC) for intraoperative cardiopulmonary support during lung transplantation has been increasing in the recent years. Our group previously described a novel hybrid extracorporeal membrane oxygenation (ECMO) circuit for use in lung transplantation. TECHNIQUE: Our approach for intraoperative management of our novel hybrid ECMO circuit for lung transplantation is driven by two main goals: The first is to deliver management that ensures an appropriate balance between the native and ECMO cardiac outputs in order to provide a stable environment that promotes attenuation of ischemic-reperfusion injury during implantation. The second is to provide a stable hemodynamic environment that results in an appropriate global perfusion guided by multiple monitors and an organ systems-based approach during implantation. COMMENTS: Our novel technique for intraoperative management of this circuit during lung transplantation is described.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Pulmón , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Card Surg ; 34(1): 47-49, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30597627

RESUMEN

Removal of the HeartMate II left ventricular assist device (LVAD) usually requires a sternotomy. We report a case of HeartMate III LVAD implantation to the descending aorta via a left thoracotomy while leaving most of the HeartMate II device in place to avoid redo-sternotomy.


Asunto(s)
Aorta Torácica/cirugía , Remoción de Dispositivos/métodos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Esternotomía/métodos , Adulto , Falla de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Reoperación , Tomografía Computarizada por Rayos X
14.
J Card Surg ; 33(6): 316-321, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29726039

RESUMEN

BACKGROUND AND AIM: We examined the relationship between serum lactate and hemoglobin levels on renal function and postoperative outcome in low-risk elective coronary artery bypass graft (CABG) patients. METHODS: Intraoperative hemoglobin and lactate levels were measured in elective isolated CABG patients. Patients with renal dysfunction (baseline creatinine>2 mg/dL) were excluded. Multivariate logistic regression was used to determine associations between lactate, hemoglobin, and acute kidney injury (AKI). RESULTS: A total of 375 patients met study requirements, and 56/375 (15%) developed AKI. Of the patients who developed AKI, 43/278 (15.5%) were males, 13/97 (13.4%) females, and 11/44 (25%) African-Americans. Bivariate analysis between AKI and non-AKI subgroups found significant differences in age, race, baseline estimated glomerular filtration rate, preoperative hemoglobin, peak serum lactate, initial hemoglobin, and nadir hemoglobin. A high peak Lactate level (odds ratio [OR] 1.44[1.15-1.82]), low hemoglobin (OR 0.69[0.49-0.96]), and African American race (OR 2.26[0.96-5.05]) were independently associated with acute kidney injury. A significant relationship between decreasing intraoperative hemoglobin and increasing intraoperative serum lactate levels was observed exclusively in patients who developed postoperative AKI. Serum creatinine levels peaked, on average, 48 h postoperatively in the AKI subset of patients. CONCLUSION: In this series, 15% of patients who underwent elective cardiopulmonary bypass developed transient acute renal dysfunction. High lactate levels and low hemoglobin levels during cardiopulmonary bypass were associated with an increased risk of kidney injury.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Puente de Arteria Coronaria , Procedimientos Quirúrgicos Electivos , Hemoglobinas , Lactatos/sangre , Complicaciones Posoperatorias/diagnóstico , Lesión Renal Aguda/epidemiología , Adulto , Anciano , Biomarcadores/sangre , Puente Cardiopulmonar , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Grupos Raciales , Riesgo , Factores Sexuales
15.
Front Cardiovasc Med ; 11: 1345540, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38357514

RESUMEN

Background: The pulsed-electron avalanche knife (PEAK) PlasmaBlade provides an atraumatic, scalpel-like cutting precision and electrocautery-like hemostasis. PlasmaBlade operates near body temperature, and its long, thin, and malleable tip can overcome the limitations of a surgical knife. In this study, we aimed to evaluate our clinical experience and histopathological outcomes of septal myectomy using PlasmaBlade. Methods: Electronic medical records were reviewed for preoperative, operative, and follow-up data of the patients who underwent septal myectomy using PEAK PlasmaBlade at our institute between January 2019 and December 2022. Histopathology of the myectomy specimens was reviewed for the depth of muscle necrosis and compared with the left atrial appendage (LAA) specimen. Results: Twenty-nine patients underwent septal myectomy using the PEAK PlasmaBlade. No mortality was reported. The mean age was 60.6 ± 12.5 years, and 58.6% of patients were male. Peak left ventricular outflow tract (LVOT) gradients were 40.5 ± 34.9 mmHg at rest and 56.5 ± 34.9 mmHg after provocation. Concomitant procedures performed were LAA ligation in 20 (69.0%), aortic valve replacement in 5 (17.2%), and coronary artery bypass grafting in 3 (10.3%) patients. Postoperative complications were complete heart block in one (3.4%) and ventricular septal defect in two (6.9%) patients. Both the ventricular septal defects were identified intraoperatively and repaired. Histopathology of myectomy specimens demonstrated cautery artifact limited to <50 µm depth compared to >1,000 µm with conventional electrocautery. At a mean follow-up of 8.4 ± 10.3 months, the mean LVOT gradient was 4.4 ± 5.8 mmHg at rest and 9.5 ± 3.3 mmHg after provocation. All patients were alive and in New York Heart Association class I/II. No patient developed complications or required reintervention or reoperation. Conclusion: Adequate septal myectomy can be precisely and safely performed using the PEAK PlasmaBlade with minimal collateral damage.

16.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38686682

RESUMEN

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Ecocardiografía Transesofágica , Cardiopatías Congénitas , Hallazgos Incidentales , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Valor Predictivo de las Pruebas , Implantación de Prótesis de Válvulas Cardíacas , Ecocardiografía Doppler en Color
17.
J Surg Case Rep ; 2024(4): rjae211, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38605700

RESUMEN

Lung transplant recipients are at higher risk of developing COVID-19 infection compared to other solid organ transplants. The risk further increases in the unvaccinated patients. We present a case of a 43-year-old male who underwent bilateral sequential lung transplantation for pulmonary alveolar microlithiasis (PAM) and had an uneventful recovery. However, two years post-transplantation, the patient developed chronic lung allograft dysfunction (CLAD) with bronchiolitis obliterans syndrome and two episodes of COVID-19 infection. During the second episode of COVID-19 infection, the patient developed sepsis and multi-organ dysfunction ultimately resulting in death. Our case report highlights the increased susceptibility of PAM patients' post-lung transplant to COVID-19 infection. Continuous follow-up of PAM patients' post-lung transplantation is necessary to prevent unfavorable outcomes.

18.
BMC Rheumatol ; 8(1): 9, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38424614

RESUMEN

BACKGROUND: Impella is an advanced ventricular assist device frequently used as a bridge to heart transplantation. The association of Impella with increased rates of gout flares has not been studied. Our primary aim is to determine the rates of gout flares in patients on Impella support. METHODOLOGY: A retrospective study was conducted between January 2017 and September 2022 involving all patients who underwent heart transplantation. The cohort was divided into two groups based on Impella support for statistical analysis. In patients receiving Impella support, outcome measures were compared based on the development of gout flares. 1:1 nearest neighbor propensity match, as well as inverse propensity of treatment weighted analyses, were performed to explore the causal relationship between impella use and gout flare in our study population. RESULTS: Our analysis included 213 patients, among which 42 (19.71%) patients were supported by Impella. Impella and non-Impella groups had similar age, race, and BMI, but more males were in the Impella group. Gout and chronic kidney disease were more prevalent in Impella-supported patients, while coronary artery disease was less common. The prevalence of gout flare was significantly higher in Impella patients (30.9% vs. 5.3%). 42 Impella-supported patients were matched with 42 patients from the non-impella group upon performing a 1:1 propensity matching. Impella-supported patients were noted to have a significantly higher risk of gout flare (30.9% vs. 7.1%, SMD = 0.636), despite no significant difference in pre-existing gout history and use of anti-gout medications. Impella use was associated with a significantly increased risk of gout flare in unadjusted (OR 8.07), propensity-matched (OR 5.83), and the inverse propensity of treatment-weighted analysis (OR 4.21). CONCLUSION: Our study is the first to identify the potential association between Impella support and increased rates of gout flares in hospitalized patients. Future studies are required to confirm this association and further elucidate the biological pathways. It is imperative to consider introducing appropriate measures to prevent and promptly manage gout flares in Impella-supported patients.

19.
Indian J Thorac Cardiovasc Surg ; 39(Suppl 1): 25-46, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37525710

RESUMEN

Cardiogenic shock is a state of low cardiac output that is associated with significant morbidity and mortality. A considerable proportion of patients with cardiogenic shock respond poorly to medical management and require acute mechanical circulatory support (AMCS) devices to improve tissue perfusion as well as to support the heart. In the last two decades, many new AMCS devices have been introduced to support the right, left, and both ventricles. All these devices vary in terms of the support they provide to the body and heart, mechanism of functioning, method of insertion, and adverse events. In this review, we compare and contrast the available percutaneous and surgically placed AMCS devices used in cardiogenic shock and discuss the associated clinical and hemodynamic data to make a conscious decision about choosing a device.

20.
Front Cardiovasc Med ; 10: 1237772, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37790593

RESUMEN

The incidence of post-acute myocardial infarction ventricular septal rupture (post-AMI VSR) has decreased; however, mortality after surgical repair of post-AMI VSR remains high. Patients who are not surgical candidates can be managed by heart transplant with a good outcome. A heart transplant in a patient after successful repair of VSR has never been reported. We report a patient who had persistent right heart failure after the successful repair of VSR and underwent a heart transplant with a good outcome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA