J Cardiovasc Electrophysiol ; 35(1): 136-145, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37990448

RESUMEN

INTRODUCTION: Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS: Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS: Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS: An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Recurrencia
2.
Circulation ; 145(10): 742-753, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34913361

RESUMEN

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Asunto(s)
Desfibriladores Implantables , Canadá , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Prevención Primaria/métodos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
3.
Am J Med Genet A ; 191(6): 1508-1517, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36864778

RESUMEN

Variants of filamin C (FLNC) have been identified as rare genetic substrate for hypertrophic cardiomyopathy (HCM). Data on the clinical course of FLNC-related HCM are conflicting with some studies suggesting mild phenotypes whereas other studies have reported more severe outcomes. In this study, we present a novel FLNC variant (Ile1937Asn) that was identified in a large family of French-Canadian descent with excellent segregation data. FLNC-Ile1937Asn is a novel missense variant characterized by full penetrance and poor clinical outcomes. End stage heart failure requiring transplantation occurred in 43% and sudden cardiac death in 29% of affected family members. Other particular features of FLNC-Ile1937Asn include an early disease onset (mean age of 19 years) and the development of a marked atrial myopathy (severe biatrial dilatation with remodeling and multiple complex atrial arrhythmias) that was present in all gene carriers. The FLNC-Ile1937Asn variant is a novel, pathogenic mutation resulting in a severe form of HCM with full disease penetrance. The variant is associated with a high proportion of end-stage heart failure, heart transplantation, and disease-related mortality. Close follow-up and appropriate risk stratification of affected individuals at specialized heart centers is recommended.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Cardiomiopatía Restrictiva , Insuficiencia Cardíaca , Humanos , Cardiomiopatía Restrictiva/genética , Mutación , Filaminas/genética , Canadá , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/genética , Insuficiencia Cardíaca/genética
4.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37314195

RESUMEN

AIMS: Risk stratification for sudden cardiac death in patients with Brugada syndrome remains a major challenge. Contemporary risk prediction models have only modest predictive value. The aim of this study was to assess the role of micro-RNAs from peripheral blood as candidate biomarkers in Brugada syndrome. METHODS AND RESULTS: In this prospective study, Brugada patients and unaffected control individuals were enrolled for analysis of leucocyte-derived microRNAs (miRNAs) levels. Expression levels of 798 different circulating miRNAs were analysed on the NanoString® nCounter platform. All results were cross-validated by using a quantitative polymerase chain reaction. Micro-RNA expression levels of Brugada patients were compared with clinical data. A total of 21 definite Brugada patients (38% with a history of ventricular arrhythmia or cardiac arrest) and 30 unaffected control individuals were included in the study. Micro-RNA analysis showed a distinct expression profile in Brugada patients with 42 differentially expressed markers (38 up-regulated, 4 down-regulated miRNAs). The symptom status of Brugada patients was associated with a distinct miRNA signature. Micro-RNAs 145-5p and 585-3p were significantly up-regulated in symptomatic Brugada patients (P = 0.04). Incorporating miRNAs 145-5p and 585-3p into a multivariable model demonstrated significantly increased symptom prediction (area under the curve = 0.96; 95% confidence interval: 0.88-1.00). CONCLUSION: Brugada patients display a distinct miRNA expression profile compared with unaffected control individuals. There is also evidence that certain miRNAs (miR-145-5p and miR-585-3p) are associated with the symptom status of Brugada patients. The results suggest the principal utility of leucocyte-derived miRNAs as prognostic biomarkers for Brugada syndrome.


Asunto(s)
Síndrome de Brugada , MicroARN Circulante , MicroARNs , Humanos , MicroARNs/genética , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Estudios Prospectivos , MicroARN Circulante/genética , Biomarcadores
5.
Pacing Clin Electrophysiol ; 46(8): 934-938, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36550633

RESUMEN

Symptomatic thrombus formation due to a permanent pacemaker (PM) lead is a rare complication. It could be associated with serious outcome and should be suspected in patients who present with unexplained right heart failure, dyspnea, or syncope following dual-chamber PM implantation. A timely decision to perform an echocardiographic examination, followed by medical, thrombolytic, or surgical treatment can be necessary. We describe the case of an 84-year-old man who presented with syncope and hypotension a few days after PM implantation. A transesophageal echocardiography revealed a mobile mass in the right atrium attached to the pacemaker lead. Intravenous heparin allowed a complete resolution of the thrombus.


Asunto(s)
Marcapaso Artificial , Trombosis , Masculino , Humanos , Anciano de 80 o más Años , Trombosis/diagnóstico por imagen , Trombosis/etiología , Marcapaso Artificial/efectos adversos , Ecocardiografía , Ecocardiografía Transesofágica , Síncope
6.
Pacing Clin Electrophysiol ; 46(7): 639-644, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37196145

RESUMEN

INTRODUCTION: Superior vena cava (SVC) tear is the most lethal complication during transvenous lead extraction (TLE) with a mortality rate as high as 50%. Treatment involves aggressive attempts to maintain cardiac output and immediate sternotomy to localize and repair the vascular tear. Occlusion balloons have been developed to provisionally occlude the lacerated SVC and to provide hemodynamic stability allowing time for surgery. In case of mediastinal hematoma without hemodynamic instability, the strategy remains unclear. METHODS AND RESULTS: We describe two cases of SVC tear during TLE. The first case was a 60-year-old man who presented with a right ventricular single-chamber defibrillator lead fracture and innominate vein stenosis. The RV lead was removed using a laser sheath causing a mediastinal hematoma with no active bleeding during surgical exploration few hours later. The second case was a 28-year-old man that presented with a right atrial (RA) lead fracture and RV lead insulation failure in a dual-chamber defibrillator (ICD). CONCLUSION: Both the RA and RV leads were removed with mechanical sheaths, and a mediastinal hematoma was medically managed.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Masculino , Humanos , Persona de Mediana Edad , Adulto , Vena Cava Superior/cirugía , Marcapaso Artificial/efectos adversos , Atrios Cardíacos/cirugía , Hematoma , Remoción de Dispositivos/métodos , Desfibriladores Implantables/efectos adversos
7.
Am Heart J ; 248: 1-12, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35219715

RESUMEN

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Canadá , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
8.
J Electrocardiol ; 71: 40-43, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35078073

RESUMEN

Bidirectional ventricular tachycardia (BVT) is part of the spectrum of polymorphic ventricular tachycardia (VT). This is a case report of a 59-year-old male with stable coronary artery disease and baseline normal left ventricular ejection fraction (LVEF) who was followed for high burden symptomatic monomorphic premature ventricular complexes (PVC). He was admitted for syncope. The ECG showed recurrent non-sustained alternating morphology and double cycle length VT runs associated with deterioration in LVEF but without coronary artery disease progression. The patient had a successful catheter ablation of two distinct left ventricular PVC focus. This is a rare ECG pattern of alternating morphology VT similar to a bidirectional VT.


Asunto(s)
Ablación por Catéter , Enfermedad de la Arteria Coronaria , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Electrocardiografía , Volumen Sistólico , Taquicardia , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/complicaciones , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
9.
BMC Health Serv Res ; 21(1): 435, 2021 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-33957918

RESUMEN

BACKGROUND/PURPOSE: Interventional cardiac electrophysiology (EP) is a rapidly evolving field in Canada; a nationwide registry was established in 2011 to conduct a periodic review of resource allocation. METHODS: The registry collects annual data on EP lab infrastructure, imaging, tools, human resources, procedural volumes, success rates, and wait times. Leading physicians from each EP lab were contacted electronically; participation was voluntary. RESULTS: All Canadian EP centres were identified (n = 30); 50 and 45 % of active centres participated in the last 2 instalments of the registry. A mean of 508 ± 270 standard and complex catheter ablation procedures were reported annually for 2015-2016 by all responding centres. The most frequently performed ablation targets atrial fibrillation (PVI) arrhythmia accounting for 36 % of all procedures (mean = 164 ± 85). The number of full time physicians ranges between 1 and 7 per centre, (mean = 4). The mean wait time to see an electrophysiologist for an initial non-urgent consult is 23 weeks. The wait time between an EP consult and ablation date is 17.8 weeks for simple ablation, and 30.1 weeks for AF ablation. On average centres have 2 (range: 1-4) rooms equipped for ablations; each centre uses the EP lab an average of 7 shifts per week. While diagnostic studies and radiofrequency ablations are performed in all centres, point-by-point cryoablation is available in 85 % centres; 38 % of the respondents use circular ablation techniques. CONCLUSIONS: This initiative provides contemporary data on invasive electrophysiology lab practices. The EP registry provides activity benchmarks on national trends and practices.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Canadá/epidemiología , Técnicas Electrofisiológicas Cardíacas , Electrofisiología , Humanos , Sistema de Registros , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-32627264

RESUMEN

BACKGROUND: Concerns remain regarding the effectiveness of PVI using the fixed diameter non-compliant cryoballoon in the presence of a left common pulmonary vein (LCPV). We sought to evaluate the effectiveness of PVI performed by contact-force guided radiofrequency (CF-RF) versus second-generation cryoballoon-based ablation in patients with LCPV. METHODS AND RESULTS: We enrolled 346 patients with paroxysmal AF and randomized them to CF-RF or cryoballoon ablation. PV anatomy was not assessed prior to enrolment, and there were no exclusions based on PV anatomy. All patients received an implantable cardiac monitor. LCPV was observed in 13.6% of patients (47/346). Left atrial time and fluoroscopy time did not differ between those with and without LCPV (P=0.58 and P=0.06, respectively). Freedom from any atrial tachyarrhythmia at one year was observed in 46.8% with LCPV and 54.5% without LCPV (P=0.06). In those with LCPV the freedom from any atrial tachyarrhythmia did not differ between those randomized to CF-RF or cryoballoon ablation (HR for recurrence 1.19, 95% CI 0.53-2.65, P=0.69). In those with LCPV the AF burden was reduced to a similar extent with CF-RF and cryoballoon ablation (99.7% vs. 99.5%, respectively; P=0.97). CONCLUSIONS: In this randomized clinical trial, the presence of a LCPV was associated with a trend towards higher rates of arrhythmia recurrence following PVI. No significant difference in arrhythmia recurrence was observed between patients with LCPV randomized to cryoballoon ablation or contact-force guided RF ablation, suggesting that either ablation modality is suitable in this population. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE], NCT01913522) This article is protected by copyright. All rights reserved.

11.
Europace ; 22(7): 1017-1025, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32531030

RESUMEN

AIMS: Atrial fibrillation (AF) significantly impairs patients' quality of life (QOL). We performed this study to investigate the effect of AF-ablation success and atrial fibrillation burden (AFB) on QOL measures. METHODS AND RESULTS: Overall, 230 patients with paroxysmal AF refractory to antiarrhythmic drugs were enrolled and underwent ablation in a multicentre, prospective cohort. Electrocardiogram, 48-h Holter, Canadian Cardiovascular Society Severity of Atrial Fibrillation (CCS-SAF), short form-12 (SF-12), and Atrial Fibrillation Effect on Quality of life (AFEQT) scales were used to assess patients. Atrial fibrillation burden was defined as total duration of AF during the month prior to each visit (h/month). The change in AFB was calculated as the difference between the month prior to the 12-month post-ablation and the baseline pre-ablation. The Minimal Clinically Important Difference (MCID) was considered as a 19-point change for AFEQT and 3-5-point change for SF-12 scores. There was significant rise in the AFEQT and SF12 and decrease in CCS-SAF score post-AF ablation; however, the magnitude of these changes was greater in patients without AF recurrence (P < 0.05). The QOL score that best differentiated patients with and without recurrence was AFEQT, while, CCS-SAF was the most specific score. Patients with AFB decrease >19 h/month had significantly greater change in QOL scores. Atrial fibrillation burden < 24 h/month at 12-months post-ablation was associated with significant changes in QOL and CCS-SAF when adjusting for baseline scores and other covariates. These changes were consistent with the MCID of these measures. CONCLUSION: Patients experience significant improvements in QOL post-ablation, which correlate with a decrease in AFB despite ongoing brief recurrences of AF. CLINICAL TRIAL REGISTRATION: NCT01562912. https://www.clinicaltrials.gov/ct2/show/NCT01562912? term=capcost&rank=1.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Canadá , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Humanos , Estudios Prospectivos , Calidad de Vida , Recurrencia , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 43(11): 1366-1372, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33021739

RESUMEN

BACKGROUND: Monitoring of cardiac implantable electronic devices was highly impacted by the COVID-19 pandemic considering the high volume of in-person visits for regular follow-up. Recent recommendations highlight the important role of remote monitoring to prevent exposure to the virus. This study compared remote monitoring of implantable cardioverter defibrillators (ICDs) in patients whose in-person annual visit was substituted for a remote monitoring session with patients who were already scheduled for a remote monitoring session. METHODS: This was a cross-sectional observational study of 329 consecutive patients between 20 March and 24 April 2020. Group 1 included 131 patients whose in-person annual visit was substituted for a remote monitoring session. Group 2 included 198 patients who underwent a remote monitoring session as scheduled in their usual device follow-up. The time interval since the last in-person visit was 13.3 ± 3.2 months in group 1 and 5.9 ± 1.7 months in group 2 (P < .01). RESULTS: In group 1, 15 patients (11.5%) experienced a clinical event compared to 15 patients (7.6%) in group 2 (P = .25). Nineteen patients (14.5%) required a physician intervention in group 1 compared to 19 patients (9.6%) in group 2 (P = .22). Two patients (1.5%) in group 1 and four patients (2.0%) in group 2 required an early in-person follow-up visit during the pandemic (P > .99). CONCLUSION: Remote monitoring of ICDs is useful to identify clinical events and allows physicians to treat patients appropriately during the COVID-19 pandemic regardless of the time interval since their last in-person visit. It reduces significantly in-person visit for regular follow-up.


Asunto(s)
Desfibriladores Implantables , Telemetría , Anciano , COVID-19/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos
13.
N Engl J Med ; 375(2): 111-21, 2016 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-27149033

RESUMEN

BACKGROUND: Recurrent ventricular tachycardia among survivors of myocardial infarction with an implantable cardioverter-defibrillator (ICD) is frequent despite antiarrhythmic drug therapy. The most effective approach to management of this problem is uncertain. METHODS: We conducted a multicenter, randomized, controlled trial involving patients with ischemic cardiomyopathy and an ICD who had ventricular tachycardia despite the use of antiarrhythmic drugs. Patients were randomly assigned to receive either catheter ablation (ablation group) with continuation of baseline antiarrhythmic medications or escalated antiarrhythmic drug therapy (escalated-therapy group). In the escalated-therapy group, amiodarone was initiated if another agent had been used previously. The dose of amiodarone was increased if it had been less than 300 mg per day or mexiletine was added if the dose was already at least 300 mg per day. The primary outcome was a composite of death, three or more documented episodes of ventricular tachycardia within 24 hours (ventricular tachycardia storm), or appropriate ICD shock. RESULTS: Of the 259 patients who were enrolled, 132 were assigned to the ablation group and 127 to the escalated-therapy group. During a mean (±SD) of 27.9±17.1 months of follow-up, the primary outcome occurred in 59.1% of patients in the ablation group and 68.5% of those in the escalated-therapy group (hazard ratio in the ablation group, 0.72; 95% confidence interval, 0.53 to 0.98; P=0.04). There was no significant between-group difference in mortality. There were two cardiac perforations and three cases of major bleeding in the ablation group and two deaths from pulmonary toxic effects and one from hepatic dysfunction in the escalated-therapy group. CONCLUSIONS: In patients with ischemic cardiomyopathy and an ICD who had ventricular tachycardia despite antiarrhythmic drug therapy, there was a significantly lower rate of the composite primary outcome of death, ventricular tachycardia storm, or appropriate ICD shock among patients undergoing catheter ablation than among those receiving an escalation in antiarrhythmic drug therapy. (Funded by the Canadian Institutes of Health Research and others; VANISH ClinicalTrials.gov number, NCT00905853.).


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Cardiomiopatías/complicaciones , Ablación por Catéter , Taquicardia Ventricular/terapia , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Cardiomiopatías/mortalidad , Ablación por Catéter/efectos adversos , Desfibriladores Implantables , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Recurrencia , Prevención Secundaria , Taquicardia Ventricular/tratamiento farmacológico
14.
Pacing Clin Electrophysiol ; 42(7): 942-950, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31157407

RESUMEN

BACKGROUND: Multipolar phased pulmonary vein ablation catheter (PVAC), specifically its second-generation (PVAC-Gold), has been associated with reduced procedural time for atrial fibrillation (AF) ablation compared to traditional catheters. We performed this study to compare the efficacy of PVAC with point-by-point radiofrequency (RF) ablation. METHODS: This is a multicenter-cohort study (2012-2017), involving patients with symptomatic, paroxysmal AF refractory to at least one antiarrhythmic medication. Overall, 230 patients were enrolled to (A) PVAC and (B) control groups. Subanalyses were done for ablations performed with PVAC-Gold, and for ablations performed without left atrial (LA) ablation in addition to pulmonary vein isolation. Electrocardiogram and 48-h Holter monitoring were used to assess patients at 3, 6, 9, and 12 months postablation. Recurrence was defined as any atrial arrhythmia >30 s excluding an initial 3-month blanking period. RESULTS: Freedom from any atrial arrhythmia at 12 months postablation was 35.70% and 52.80% in groups A and B, respectively (P = .01). Freedom from atrial arrhythmia was not significantly different when limiting the PVAC cohort to PVAC-Gold and excluding patients with additional LA ablation (A: 44.30%; B: 44.30%, P = .80). Procedural and ablation time was significantly lower in group A than B. Multivariate regression model showed female gender (odds ratio [OR] = 2.90) and recurrence during blanking period (OR = 6.60) as significant predictors of recurrence. CONCLUSION: This study suggests that PVAC may achieve less freedom from AF than point-by-point RF; however, efficacy is similar when comparing PVAC-Gold and point-by-point stand-alone PV isolation. PVAC is associated with significantly reduced procedural times for AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia
15.
J Electrocardiol ; 53: 57-63, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30641305

RESUMEN

BACKGROUND: Cardiostat™ is a single lead ambulatory ECG monitor. Recording is made through 2 electrodes positioned in a lead 1-like configuration. We first validated its accuracy for atrial fibrillation detection compared to a 12-lead ECG. In the second phase of the study, arrhythmia detection accuracy was compared between Cardiostat™ ambulatory ECG and a standard 24 h Holter ECG monitoring. METHOD/RESULTS: Phase one of the study included patients undergoing cardioversion for atrial fibrillation (AF) or atrial flutter. Cardiostat™ tracings were compared with standard 12-lead ECG. In the second phase, patients undergoing 24 h ambulatory Holter ECG monitoring for control or suspicion of atrial fibrillation (AF) were included. Simultaneous Holter monitoring and Cardiostat™ ECG recordings were performed. Tracings were analysed and compared. Two hundred twelve monitoring were compared. AF was diagnosed in 73 patients. Agreement between Cardiostat™ ECG and standard Holter monitoring was 99% for AF detection with kappa = 0.99. Kappa correlation for atrial flutter detection was only moderate at 0.51. AF burden was similar in both recordings. Noise hindered analysis in a greater proportion with Cardiostat™ compared to Holter ambulatory ECG (8.5 vs 3.8%). CONCLUSION: Cardiostat™ ambulatory ECG device showed excellent correlation with the standard Holter ECG monitoring for AF detection. Holter monitoring was however superior to discriminate premature atrial and ventricular beats and to qualify the morphology of PVCs since it has more vectors for analysis. Added value of Cardiostat™ includes longer monitoring duration, less cumbersome installation and water resistance.


Asunto(s)
Fibrilación Atrial/diagnóstico , Aleteo Atrial/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino
16.
J Cardiovasc Electrophysiol ; 29(3): 421-434, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29316012

RESUMEN

BACKGROUND/OBJECTIVE: We compared health-related quality of life (HRQoL) in patients randomized to escalated therapy and those randomized to ablation for ventricular tachycardia in the VANISH trial. METHODS: HRQoL was assessed among VANISH patients at baseline and 3-, 6-, and 12-month follow-up visits. Four validated instruments were used: the SF-36, the implanted cardioverter defibrillator (ICD) Concerns questionnaire (ICDC), the Hospital Anxiety and Depression Scale (HADS), and the EuroQol five dimensions questionnaire (EQ-5D). Linear mixed-effects modeling was used for repeated measures with SF-36, HADS, ICDC, and EQ-5D as dependent variables. In a second model, treatment was subdivided by amiodarone use prior to enrollment. RESULTS: HRQoL did not differ significantly between those randomized to ablation or escalated therapy. On subgroup analysis, improvement in SF-36 measures was seen at 6 months in the ablation group for social functioning (63.5-69.3, P = 0.03) and energy/fatigue (43.0-47.9, P = 0.01). ICDC measures showed a reduction in ICD concern in the ablation group at 6 months (10.4-8.7, P = 0.01) and a reduction in ICD concern in the escalated therapy group at 6 months (10.9-9.4, P = 0.04). EQ-5D measures showed a significant improvement in overall health in ablation patients at 6 months (63.4-67.3, P = 0.04). CONCLUSION: Patients in the VANISH study randomized to ablation did not have a significant change in quality of life outcomes compared to those randomized to escalated therapy. Some subgroup findings were significant, as those randomized to ablation showed persistent improvement in SF-36 energy/fatigue and ICD concern, and transient improvement in SF-36 social functioning and EQ-5D overall health.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Ablación por Catéter , Calidad de Vida , Taquicardia Ventricular/terapia , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Ansiedad/diagnóstico , Ansiedad/prevención & control , Ansiedad/psicología , Australia , Ablación por Catéter/efectos adversos , Emociones , Europa (Continente) , Femenino , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Conducta Social , Encuestas y Cuestionarios , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/psicología , Factores de Tiempo , Resultado del Tratamiento
17.
Artículo en Inglés | MEDLINE | ID: mdl-29856075

RESUMEN

INTRODUCTION: Implantable cardioverter-defibrillator (ICD) DF-4 connectors have been introduced to facilitate defibrillator lead connection and to reduce the size of device header. There are limited data regarding the overall performance of those leads and no comparison between different ICD DF-4 leads. METHODS: This is a cohort study of consecutive patients implanted with ICD DF-4 lead system at one University Centre between October 2010 and February 2015. A historical control group of patients with ICD DF-1 lead implantation was used for comparison. The following ICD DF-4 leads were evaluated: St. Jude Medical Durata 7122Q (St. Jude Medical, St. Paul, MN, USA), Medtronic Sprint Quattro Secure 6935 M (Medtronic Inc., Minneapolis, MN, USA), Boston Scientific Endotak Reliance 4-Site 0293 (Boston Scientific, Marlborough, MA, USA), and Boston Scientific Reliance 4-Front 0693. This study evaluated the acute and mid-term performances of those leads as well as complications. RESULTS: A total of 812 patients (age 63 ± 12 years, 80% male, left ventricular ejection fraction 31 ± 12%) underwent implantation of an ICD DF-4 lead. Acute and follow-up R-wave sensing and threshold were excellent. Compared to implantation, intrinsic R waves were higher at follow-up for Boston Scientific and Medtronic leads, and pacing lead impedances were lower for all leads at first follow-up (P < 0.001). The number of lead dislodgement or failure was similar between all leads. The estimated lead survival rates at 3 years were 95.6% for Boston Scientific Endotak 4-Site, 97.1% for Boston Scientific 4-Front, 97.7% for Medtronic Sprint Quattro, and 97.5% for St. Jude Durata (P  =  0.553). CONCLUSION: All ICD DF-4 leads had excellent acute and mid-term electrical performances. Longer follow-up will be necessary to confirm their sustained performance.

18.
J Cardiovasc Electrophysiol ; 27(12): 1483-1487, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27545306

RESUMEN

Contact-force (CF) catheters appear to be more effective compared to standard ablation catheters for complex radiofrequency ablation including atrial fibrillation (AF) ablation when optimal CF >10 g is achieved. Some have suggested that this technology could also improve procedural safety. We report 2 cases of atrioesophageal fistulae (AEF), a rare but catastrophic complication of AF ablation. These are to our knowledge the first cases of AEF described after using CF catheters.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Fístula Esofágica/etiología , Fístula/etiología , Cardiopatías/etiología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Autopsia , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Fístula Esofágica/diagnóstico por imagen , Fístula Esofágica/cirugía , Esofagoscopía , Resultado Fatal , Fístula/diagnóstico por imagen , Fístula/cirugía , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 38(1): 77-83, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25223705

RESUMEN

BACKGROUND: Riata™ and Riata ST defibrillation leads (St. Jude Medical, Sylmar, CA, USA) are susceptible to insulation defects with conductor externalization. Cine-fluoroscopy is considered to be the gold standard for the documentation of insulation defects, but similar detection rates have been reported for posterior-anterior (PA)/lateral chest x-ray (CXR) with zooming. OBJECTIVE: Prospective single-center study to assess the diagnostic equivalence of a PA/lateral CXR with zooming for the detection of Riata insulation defects in a direct comparison to cine-fluoroscopy. METHODS: Seventy-eight consecutive patients underwent 3-view cine-fluoroscopy and a PA/lateral CXR. All CXRs and cine-fluoroscopy images were reviewed by blinded electrophysiologists and staff radiologists. RESULTS: Forty-four of 78 patients had an abnormal cine-fluoroscopy (56%). The diagnostic correlation between PA/lateral CXR and cine-fluoroscopy was excellent (κ = 0.90; 95% confidence interval 0.80-1.00). PA/lateral CXR was equivalent to cine-fluoroscopy for the detection of conductor externalization showing a sensitivity of 97.7% and a specificity of 91.2%. The mean radiation effective dose of CXR was significantly lower compared to cine-fluoroscopy (0.09 millisievert [mSV] vs 0.85 ± 0.47 mSv; P < 0.001). Also, CXR was significantly less expensive. CONCLUSION: PA/lateral CXR with zooming is equivalent to cine-fluoroscopy for the detection of Riata insulation defects and should be considered as the preferred screening method.


Asunto(s)
Cinerradiografía , Desfibriladores Implantables , Radiografía Torácica , Anciano , Femenino , Fluoroscopía , Humanos , Masculino , Estudios Prospectivos , Radiografía Torácica/métodos