1.
Pediatr Diabetes ; 20(6): 794-799, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31140654

RESUMEN

OBJECTIVE: To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day-and-night hybrid closed-loop insulin delivery. METHODS: Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed-loop experience survey following two 3-week periods of unrestricted day-and-night hybrid closed-loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed-loop technology were explored. RESULTS: Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed-loop. Ninety percent of the responders felt less worried about their child's glucose control using closed-loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets. CONCLUSIONS: Parents/caregivers of very young children reported important quality of life benefits associated with using closed-loop, supporting adoption of this technology in this population.


Asunto(s)
Costo de Enfermedad , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Calidad de Vida , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Cuidadores/psicología , Cuidadores/estadística & datos numéricos , Niño , Preescolar , Ritmo Circadiano/fisiología , Estudios Cruzados , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/psicología , Familia/psicología , Femenino , Humanos , Lactante , Insulina/efectos adversos , Masculino , Padres/psicología , Encuestas y Cuestionarios
2.
Front Endocrinol (Lausanne) ; 12: 721028, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34456876

RESUMEN

Background: Type 1 diabetes in young children is a heavy parental burden. As part of pilot phase of the KIDSAP01 study, we conducted a baseline assessment in parents to study the association between hypoglycemia fear, parental well-being and child behavior. Methods: All parents were invited to fill in baseline questionnaires: hypoglycemia fear survey (HFS), WHO-5, Epworth Sleepiness Scale and Strength and Difficulties Questionnaire (SDQ). Results: 24 children (median age: 5-year, range 1-7 years, 63% male, mean diabetes duration: 3 ± 1.7 years) participated. 23/24 parents filled out the questionnaires. We found a higher score for the hypoglycemia fear behavior 33.9 ± 5.6 compared to hypoglycemia worry 34.6 ± 12.2. Median WHO-5 score was 16 (8 - 22) with poor well-being in two parents. Median daytime sleepiness score was high in five parents (>10). For six children a high total behavioral difficulty score (>16) was reported. Pro social behavior score was lower than normal in six children (<6). Parental well-being was negatively associated with HFS total (r = - 0.50, p <.05) and subscale scores (r = - 0.44, p <.05 for HFS-Worry and HFS-Behavior), child behavior (r = - 0.45, p = .05) and positively with child age and diabetes duration (r = 0.58, p <.01, r = 0.6, p <.01). HFS, parental well-being nor daytime sleepiness are associated with the HbA1c. Conclusion: Regular screening of parental well-being, hypoglycemia fear and child behavior should be part of routine care to target early intervention.


Asunto(s)
Diabetes Mellitus Tipo 1/psicología , Padres/psicología , Adulto , Edad de Inicio , Ansiedad/epidemiología , Ansiedad/psicología , Niño , Conducta Infantil/psicología , Preescolar , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Europa (Continente)/epidemiología , Miedo/psicología , Femenino , Humanos , Hipoglucemia/prevención & control , Hipoglucemia/psicología , Lactante , Insulina/administración & dosificación , Insulina/efectos adversos , Sistemas de Infusión de Insulina , Masculino , Encuestas y Cuestionarios
3.
Diabetes Care ; 42(4): 594-600, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30692242

RESUMEN

OBJECTIVE: We aimed to assess the feasibility and safety of hybrid closed-loop insulin delivery in children with type 1 diabetes aged 1-7 years as well as evaluate the role of diluted insulin on glucose control. RESEARCH DESIGN AND METHODS: In an open-label, multicenter, multinational, randomized crossover study, 24 children with type 1 diabetes on insulin pump therapy (median age 5 years [interquartile range 3-6] and mean ± SD HbA1c 7.4 ± 0.7% [57 ± 8 mmol/mol] and total insulin 13.2 ± 4.8 units/day) underwent two 21-day periods of unrestricted living and we compared hybrid closed-loop with diluted insulin (U20) and hybrid closed-loop with standard strength insulin (U100) in random order. During both interventions, the Cambridge model predictive control algorithm was used. RESULTS: The proportion of time that sensor glucose was in the target range between 3.9 and 10 mmol/L (primary end point) was not different between interventions (mean ± SD 72 ± 8% vs. 70 ± 7% for closed-loop with diluted insulin vs. closed-loop with standard insulin, respectively; P = 0.16). There was no difference in mean glucose levels (8.0 ± 0.8 vs. 8.2 ± 0.6 mmol/L; P = 0.14), glucose variability (SD of sensor glucose 3.1 ± 0.5 vs. 3.2 ± 0.4 mmol/L; P = 0.16), or the proportion of time spent with sensor glucose <3.9 mmol/L (4.5 ± 1.7% vs. 4.7 ± 1.4%; P = 0.47) or <2.8 mmol/L (0.6 ± 0.5% vs. 0.6 ± 0.4%; P > 0.99). Total daily insulin delivery did not differ (17.3 ± 5.6 vs. 18.9 ± 6.9 units/day; P = 0.07). No closed-loop-related severe hypoglycemia or ketoacidosis occurred. CONCLUSIONS: Unrestricted home use of day-and-night closed-loop in very young children with type 1 diabetes is feasible and safe. The use of diluted insulin during closed-loop does not provide additional benefits compared with standard strength insulin.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Algoritmos , Glucemia , Niño , Preescolar , Estudios Cruzados , Femenino , Humanos , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Lactante , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Resultado del Tratamiento