Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Opt Express ; 32(5): 7147-7157, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38439403

RESUMEN

This paper presents the analysis, implementation and experimental evaluation of a high-speed automatic focus module for a telescope-based UAV detection and tracking system. An existing optical drone detection system consisting of two telescopes and deep learning-based object detection is supplemented by suitable linear stages and passive focus algorithms to enable fast automatic focus adjustment. Field tests with the proposed system demonstrate that UAVs flying at speeds of up to 24 m/s towards the system are successfully tracked and kept in focus from more than 4500 m down to 150 m. Furthermore, different search functions and contrast measures are evaluated and it is shown that the Tenengrad operator combined with the Hill Climbing search function achieve the best performance for focusing on fast moving small UAVs.

2.
Appl Opt ; 62(26): 6986-6992, 2023 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-37707038

RESUMEN

A concept for the fast measurement and reconstruction of optical wavefronts using Shack-Hartmann sensors (SHSs) is presented. For wavefronts with a diameter at the scale of several tens of millimeters, hundreds of measurements with an SHS may be necessary to cover the wavefront. In the proposed concept, a few SHSs are used to measure about 2% of the entire wavefront, providing sufficient measurement data for its successful reconstruction. The small number of SHSs mounted in parallel makes the concept suitable for time-critical applications. A simulation analysis is performed, and an experimental validation of the concept is presented, demonstrating that the wavefront can be reconstructed with an RMS error of about 100 nm.

3.
Appl Opt ; 62(36): 9583-9590, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38108784

RESUMEN

The paper presents a concept for the sparse measurement and reconstruction of highly divergent wavefronts enabling measurements at high throughputs and beyond the dynamic range of the wavefront sensor. In the proposed concept, a direct measurement of the wavefront is carried out, where a few segments of the wavefront are measured with Shack-Hartmann sensors (SHSs). In total about 1% of the wavefront is measured and used for the reconstruction of the entire wavefront, which makes the concept suitable for applications where low measurement times are needed. A simulation analysis and an experimental validation of the concept are carried out, and results show that a wavefront with a divergence of 62° can be reconstructed with a root-mean-square error of about 200 nm.

4.
Opt Express ; 30(23): 41473-41491, 2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36366625

RESUMEN

This paper presents an algorithm for the precise registration of optical wavefronts. A wavefront exceeding the spatial or dynamic measurement range of a wavefront sensor, e.g. a Shack-Hartmann sensor, can be measured in multiple sub-measurements, each providing a segment of the wavefront. Sensor misalignment during the measurements results in the demand for registration algorithms to precisely reconstruct the entire wavefront from the segments. The proposed algorithm registers the segments in parallel and incorporates a priori information about the uncertainty of the sensor misalignment obtaining high-quality registration. A simulative analysis of the algorithm with respect to sensor misalignment and measurement errors is presented together with an application of the algorithm to a measured divergent wavefront. In the scope of the analysis, the algorithm is compared to state-of-the-art registration algorithms, such as the iterative closest point (ICP) algorithm, where an improvement of the registration performance by a factor of 3 is obtained. Results show that the algorithm is able to reconstruct a divergent and a freeform wavefront with an RMS registration error of a few tens of nanometers with a standard deviation of 80 µm and 2.4 mrad.

5.
Appl Opt ; 61(31): 9233-9240, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36607058

RESUMEN

This paper presents the design and implementation of a scalable laser ranger finder (LRF)-based prototype system, which enables distance measurement and precise localization of multiple unmanned aerial vehicles (UAVs) in real-time. The system consists of a telescope and camera as the image acquisition components, supplemented by an LRF and a fast steering mirror (FSM) to obtain the distance measurement. By combining the optical path of the camera and the LRF through a dichroic mirror, the LRF is accurately aligned by the FSM based on the angular position of a UAV within the camera field of view. The implemented prototype successfully demonstrates distance measurements of up to four UAVs with a bandwidth of 14 Hz per object.

6.
Opt Express ; 29(21): 33281-33296, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34809143

RESUMEN

The paper presents an algorithm for the precise registration of multiple wavefront segments containing large misalignment and phase differences. The measurement of a wavefront with huge dynamics or a large aperture size can be carried out in multiple Shack-Hartmann sensor measurements of segments of the wavefront. The registration algorithm is flexible with respect to the shape of the wavefront and can reconstruct a plane as well as divergent wavefronts, making it suitable for freeform wavefronts. The algorithm enables parallel registration of the wavefront segments which is carried out in an iterative manner to compensate for large misalignment errors. A simulative analysis of the proposed algorithm compares its performance to a fast parallel registration (FPR) algorithm and the established iterative closest point (ICP) algorithm. For a sensor misalignment of up to 100 µm and 3 mrad the algorithm registers a plane and a divergent wavefront with a precision that is a factor 4 and 12 better than the registration precision of the FPR and ICP algorithm.

7.
Opt Express ; 29(18): 27989-28004, 2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34614940

RESUMEN

This paper proposes a phase modulation method for Lissajous scanning systems, which provides adaptive scan pattern design without changing the frame rate or the field of view. Based on a rigorous analysis of Lissajous scanning, phase modulation constrains and a method for pixel calculation are derived. An accurate and simple metric for resolution calculation is proposed based on the area spanned by neighboring pixels and used for scan pattern optimization also considering the scanner dynamics. The methods are implemented using MEMS mirrors for verification of the adaptive pattern shaping, where a 5-fold resolution improvement in a defined region of interest is demonstrated.

8.
Appl Opt ; 60(23): 6781-6790, 2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-34613156

RESUMEN

A fast and precise algorithm for wavefront reconstruction by the registration of wavefront segments is presented. If the wavefront exceeds the sensor aperture or the dynamic range of the sensor, a Shack-Hartmann sensor can measure only segments of an optical wavefront. The algorithm registers the wavefront segments in parallel, where they are simultaneously transformed to minimize their overlap mismatch for precise reconstruction of the entire wavefront. The original nonlinear optimization problem is approximated by a convex optimization problem that can be solved more efficiently. A simulation-based analysis of the algorithm and a comparison to a previously proposed parallel registration (PR) algorithm as well as to the iterative closest point (ICP) algorithm are presented. It is shown that despite measurement noise, the algorithm can precisely register plane as well as divergent wavefronts with root mean square registration errors smaller than 10 nm. Particularly for the divergent wavefront, this enables a reduction of the registration error by a factor of up to 750 as compared to the established algorithms. Analysis and comparison to the ICP and PR algorithm also show that the computation time of the proposed algorithm can be from one to three orders of magnitude smaller.

9.
Appl Opt ; 60(6): 1578-1586, 2021 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-33690492

RESUMEN

This paper presents a robust registration algorithm for wavefront reconstruction from multiple partial measurements. Wavefronts exceeding the dynamic range or size of the Shack-Hartmann sensor can be measured as a set of segments. The wavefront is reconstructed by parallel registration of these wavefront segments, enabling compensation for sensor misalignment as well as for phase differences. For registration, a global mismatch metric is minimized by rigid body transformations and propagation of the wavefront segments. Apart from the description of the algorithm, a simulation-based evaluation and comparison to the iterative closest point (ICP) algorithm is performed. It is shown that in the case of a noisy data set, the parallel approach enables reconstruction errors that are a factor of 10 smaller than the result obtained with the ICP algorithm.

10.
Appl Opt ; 60(25): 7511-7517, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34613215

RESUMEN

This paper proposes a compact and lightweight scanning confocal chromatic sensor (SCCS) for robot-based precision three-dimensional (3-D) surface measurement applications. The integrated system design includes a 2-D fast steering mirror (FSM) to manipulate the optical path of a high precision 1-D confocal chromatic sensor (CCS). A data-driven calibration procedure is used to accurately combine the FSM deflection angles and the correspondingly measured distances to the sample surface in order to obtain a correctly reconstructed 3-D image. Lissajous scan trajectories are applied to enable efficient scans of the sample surface. The SCCS provides 3-D images at frame rates of up to 1 fps and a measurement volume of 0.35×0.25×1.8mm3, as well as the measurement of arbitrary regions of interest. Using a calibration standard including structures with defined sizes, the lateral and axial resolutions are determined to 2.5 µm and 76 nm, respectively.

11.
J Opt Soc Am A Opt Image Sci Vis ; 37(9): B46-B52, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32902419

RESUMEN

Confocal chromatic displacement sensors are versatile and precise sensors for measuring the distance to a single point. In order to obtain a 3D measurement device, this paper presents an integrated scanning sensor design that employs a tilting lens mechanism for manipulating the light path of the sensor. The optical implications of the design are analytically modeled and simulated. An experimental setup is constructed to evaluate the system design and to test its performance on a variety of samples. Results show good agreement with the simulations and modeling; with maximal tip/tilt angles of ±2.5∘, the setup is capable of measuring a volume of 1.7×1.7×1mm3 with a lateral resolution of 24.8 µm and an axial resolution of 3 µm.

12.
Appl Opt ; 59(29): 9234-9242, 2020 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-33104637

RESUMEN

This paper presents a scanning system that integrates a chromatic confocal displacement sensor for topography measurement of a surface. To take an advantage of its compactness and reliability, an off-the-shelf chromatic confocal displacement sensor is integrated. Instead of moving the sensor, a galvanometer scanner reflects the optical point to increase the scan speed, and fast and accurate scanning motion is realized by learning without a model. The resulting images are corrected based on a geometric model to compensate for image distortion.

13.
Appl Opt ; 57(18): 5242-5248, 2018 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-30117988

RESUMEN

In scanning laser triangulation sensors for 3D imaging, the achievable throughput is strongly limited by the moving mass. By realizing an optical scanning approach rather than repositioning the entire sensor, this limitation could be reduced, leading to a reduced measurement time. This work presents sensor system geometries in which only the optical path of a line triangulation sensor is manipulated by a tip-tilt mirror. In the proposed rotational scanning systems, either the illumination path or both the illumination and the reflection path are manipulated. By using ray-tracing simulation, the performance of the scanning systems are optimized and possible disadvantages can be determined up front. Using geometric relations, the surface profile can be reconstructed from the measured sensor data, the mirror position, and the model parameters. Experimental results show that the image quality of the proposed rotational scanning systems is comparable to systems based on classical translational scanning motion.

14.
Acta Biomater ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39218277

RESUMEN

Collagen fibrils are fundamental to the mechanical strength and function of biological tissues. However, they are susceptible to changes from non-enzymatic glycation, resulting in the formation of advanced glycation end-products (AGEs) that are not reversible. AGEs accumulate with aging and disease and can adversely impact tissue mechanics and cell-ECM interactions. AGE-crosslinks have been related, on the one hand, to dysregulation of collagen fibril stiffness and damage and, on the other hand, to altered collagen net surface charge as well as impaired cell recognition sites. While prior studies using Kelvin probe force microscopy (KPFM) have shown the effect glycation has on collagen fibril surface potential (i.e., net charge), the combined effect on individual and isolated collagen fibril mechanics, hydration, and surface potential has not been documented. Here, we explore how methylglyoxal (MGO) treatment affects the mechanics and surface potential of individual and isolated collagen fibrils by utilizing atomic force microscopy (AFM) nanoindentation and KPFM. Our results reveal that MGO treatment significantly increases nanostiffness, alters surface potential, and modifies hydration characteristics at the collagen fibril level. These findings underscore the critical impact of AGEs on collagen fibril physicochemical properties, offering insights into pathophysiological mechanical and biochemical alterations with implications for cell mechanotransduction during aging and in diabetes. STATEMENT OF SIGNIFICANCE: Collagen fibrils are susceptible to glycation, the irreversible reaction of amino acids with sugars. Glycation affects the mechanical properties and surface chemistry of collagen fibrils with adverse alterations in biological tissue mechanics and cell-ECM interactions. Current research on glycation, at the level of individual collagen fibrils, is sparse and has focused either on collagen fibril mechanics, with contradicting evidence, or surface potential. Here, we utilized a multimodal approach combining Kelvin probe force (KPFM) and atomic force microscopy (AFM) to examine how methylglyoxal glycation induces structural, mechanical, and surface potential changes on the same individual and isolated collagen fibrils. This approach helps inform structure-function relationships at the level of individual collagen fibrils.

15.
ACS Nano ; 16(11): 17982-17990, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36215653

RESUMEN

Mapping charged chemical groups at the solid-liquid interface is important in many areas, ranging from colloidal systems to biomolecular interactions. However, classical methods to measure surface charges either lack spatial resolution or─like Kelvin-probe force microscopy (KPFM)─cannot be applied in aqueous solutions because a DC bias voltage is used. Here, we show that using AC Kelvin probe force microscopy (AC-KPFM), in which the DC bias is replaced with an AC voltage of sufficiently high frequency, the surface potential of spatially fixated, charged surface groups can be mapped in aqueous solution. We demonstrate this with micropatterned, functionalized alkanethiol layers which expose ionized amino- and carboxy-groups. These groups are representative of the charged groups of most biomolecules such as proteins. By adjusting the pH of the solution, the charge of the groups was reversibly altered, demonstrating the electrostatic nature of the measured signal. The influence of the electric double layer (EDL) on the measurement is discussed, and we, furthermore, show how charged, micropatterned layers can be used to spatially direct the deposition of nanoparticles of opposite charge.


Asunto(s)
Nanopartículas , Agua , Microscopía de Fuerza Atómica/métodos , Agua/química , Electricidad Estática , Nanopartículas/química , Electricidad
16.
Rev Sci Instrum ; 93(5): 054103, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35649813

RESUMEN

Collagen is the major structural protein in human bodies constituting about 30% of the entire protein mass. Through a self-assembly process, triple helical collagen molecules assemble into high aspect-ratio fibers of tens to hundreds of nanometer diameter, known as collagen fibrils (CFs). In the last decade, several methods for tensile testing these CFs emerged. However, these methods are either overly time-consuming or offer low data acquisition bandwidth, rendering dynamic investigation of tensile properties impossible. Here, we describe a novel instrument for tensile testing of individual CFs. CFs are furnished with magnetic beads using a custom magnetic tweezer. Subsequently, CFs are lifted by magnetic force, allowing them to be picked-up by a microgripper structure, which is mounted on a cantilever-based interferometric force probe. A piezo-lever actuator is used to apply tensile displacements and to perform tensile tests of tethered CFs, after alignment. Once the mechanical tests are finished, CFs are removed from the microgripper by application of a magnetic field. Our novel instrument enables tensile tests with at least 25-fold increased throughput compared to tensile testing with an atomic force microscope while achieving force resolution (p-p) of 10 nN at a strain resolution better than 0.1%.


Asunto(s)
Colágeno , Humanos , Microscopía de Fuerza Atómica/métodos , Piel , Resistencia a la Tracción
17.
Chembiochem ; 11(14): 2026-33, 2010 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-20715263

RESUMEN

A collection of new reversible glycosidase inhibitors of the iminoalditol type featuring N-substituents containing perfluorinated regions has been prepared for evaluation of physicochemical, biochemical and diagnostic properties. The vast variety of feasible oligofluoro moieties allows for modular approaches to customised structures according to the intended applications, which are influenced by the fluorine content as well as the distance of the fluorous moiety from the ring nitrogen. The first examples, in particular in the D-galacto series, exhibited excellent inhibitory activities. A preliminary screen with two human cell lines showed that, at subinhibitory concentrations, they are powerful pharmacological chaperones enhancing the activities of the catalytically handicapped lysosomal D-galactosidase mutants associated with GM1 gangliosidosis and Morquio B disease.


Asunto(s)
Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/farmacología , Galactosidasas/antagonistas & inhibidores , Gangliosidosis GM1/tratamiento farmacológico , Alcoholes del Azúcar/química , Alcoholes del Azúcar/farmacología , Línea Celular , Café/enzimología , Inhibidores Enzimáticos/uso terapéutico , Escherichia coli/enzimología , Fibroblastos/efectos de los fármacos , Fibroblastos/enzimología , Galactosidasas/metabolismo , Halogenación , Humanos , Iminas/química , Iminas/farmacología , Iminas/uso terapéutico , Rhizobium/enzimología , Alcoholes del Azúcar/uso terapéutico
18.
Mol Genet Metab ; 100(3): 262-8, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20409738

RESUMEN

G(M1)-gangliosidosis (GM1) and Morquio B disease (MBD) are rare lysosomal storage disorders caused by mutations in the gene GLB1. Its main gene product, human acid beta-galactosidase (beta-Gal) degrades two functionally important molecules, G(M1)-ganglioside and keratan sulfate in brain and connective tissues, respectively. While GM1 is a severe, phenotypically heterogenous neurodegenerative disorder, MBD is a systemic bone disease without effects on the central nervous system. A MBD-specific mutation, p.W273L, was shown to produce stable beta-Gal precursors, normally transported and processed to mature, intralysosomal beta-Gal. In accordance with the MBD phenotype, elevated residual activity against G(M1)-ganglioside, but strongly reduced affinity towards keratan sulfate was found. Most GM1 alleles, in contrast, were shown to affect precursor stability and intracellular transport. Specific alleles, p.R201C and p.R201H result in misfolded, unstable precursor proteins rapidly degraded by endoplasmic reticulum-associated protein degradation (ERAD). They may therefore be sensitive to stabilization by small molecules which bind at the active site and provide proper conformation. Thus the stabilized protein may escape from ERAD processes, and reach the lysosomes in an active state, as proposed for enzyme enhancement therapy (EET). This paper demonstrates that a novel iminosugar, DLHex-DGJ, has potent effects as competitive inhibitor of human acid beta-galactosidase in vitro, and describes its effects on activity, protein expression, maturation and intracellular transport in vivo in 13 fibroblasts lines with GLB1 mutations. Beside p.R201C and p.R201H, two further alleles, p.C230R and p.G438E, displayed significant sensitivity against DLHex-DGJ, with an increase of catalytic activity, and a normalization of transport and lysosomal processing of beta-Gal precursors.


Asunto(s)
1-Desoxinojirimicina/análogos & derivados , Gangliosidosis GM1/tratamiento farmacológico , Mucopolisacaridosis IV/tratamiento farmacológico , 1-Desoxinojirimicina/química , 1-Desoxinojirimicina/farmacocinética , 1-Desoxinojirimicina/farmacología , Alelos , Línea Celular , Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/farmacocinética , Inhibidores Enzimáticos/farmacología , Fibroblastos/efectos de los fármacos , Fibroblastos/metabolismo , Gangliosidosis GM1/genética , Gangliosidosis GM1/metabolismo , Humanos , Chaperonas Moleculares/química , Chaperonas Moleculares/farmacocinética , Chaperonas Moleculares/farmacología , Mucopolisacaridosis IV/genética , Mucopolisacaridosis IV/metabolismo , Mutación , beta-Galactosidasa/antagonistas & inhibidores , beta-Galactosidasa/genética , beta-Galactosidasa/metabolismo
19.
Bioorg Med Chem Lett ; 20(14): 4077-9, 2010 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-20610152

RESUMEN

Biotin-iminosugar conjugates of different configuration such as D-gluco, D-galacto, L-ido as well as a furanoid representative in the D-manno configuration have been synthesised and exhibit powerful inhibition of beta-glucosidase from Agrobacterium sp. with K(i) values in the range of the respective parent compounds. Such molecular probes have potential for activity-based protein profiling taking advantage of the biotin-(strept)avidin interaction.


Asunto(s)
Biotina/síntesis química , Biotina/farmacología , Alcoholes del Azúcar/síntesis química , Alcoholes del Azúcar/farmacología , Evaluación Preclínica de Medicamentos , Sondas Moleculares
20.
Beilstein J Org Chem ; 6: 21, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20502610

RESUMEN

N-Alkylation at the ring nitrogen of the D-galactosidase inhibitor 1-deoxygalactonojirimycin with a functionalised C 6alkyl chain followed by modification with different aromatic substituents provided lipophilic 1-deoxygalactonojirimycin derivatives which exhibit inhibitory properties against ß-glycosidases from E. coli and Agrobacterium sp. as well as green coffee bean α-galactosidase. In preliminary studies, these compounds also showed potential as chemical chaperones for GM1-gangliosidosis related ß-galactosidase mutants.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA