Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Proteome Res ; 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520676

RESUMEN

Metabolomics is an emerging and powerful bioanalytical method supporting clinical investigations. Serum and plasma are commonly used without rational prioritization. Serum is collected after blood coagulation, a complex biochemical process involving active platelet metabolism. This may affect the metabolome and increase the variance, as platelet counts and function may vary substantially in individuals. A multiomics approach systematically investigating the suitability of serum and plasma for clinical studies demonstrated that metabolites correlated well (n = 461, R2 = 0.991), whereas lipid mediators (n = 83, R2 = 0.906) and proteins (n = 322, R2 = 0.860) differed substantially between specimen. Independently, analysis of platelet releasates identified most biomolecules significantly enriched in serum compared to plasma. A prospective, randomized, controlled parallel group metabolomics trial with acetylsalicylic acid administered for 7 days demonstrated that the apparent drug effects significantly differ depending on the analyzed specimen. Only serum analyses of healthy individuals suggested a significant downregulation of TXB2 and 12-HETE, which were specifically formed during coagulation in vitro. Plasma analyses reliably identified acetylsalicylic acid effects on metabolites and lipids occurring in vivo such as an increase in serotonin, 15-deoxy-PGJ2 and sphingosine-1-phosphate and a decrease in polyunsaturated fatty acids. The present data suggest that plasma should be preferred above serum for clinical metabolomics studies as the serum metabolome may be substantially confounded by platelets.

2.
Ophthalmic Res ; 66(1): 1293-1299, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37797590

RESUMEN

INTRODUCTION: The objective of this study was to evaluate the prevalence of ocular surface damage assessed by corneal staining scores right after cataract surgery and whether it can be prevented using chitosan-N-acetylcysteine (C-NAC) eye drops. METHODS: We included patients scheduled for routine cataract surgery. Each patient was randomly assigned to one of three groups. Patients in group 1 underwent routine cataract surgery with no additional eye drops. In group 2, patients received C-NAC eye drops after cataract surgery, and in group 3, C-NAC was applied both before and after surgery. Both groups continued the treatment once daily for 4 days. Ocular surface alteration was assessed using the National Eye Institute (NEI) score, and the visual analog scale (VAS) was used to evaluate subjective complaints. RESULTS: Thirty-six patients were included in the final analyses. One hour after cataract surgery, a statistically significant increase in corneal fluorescein staining was observed in all groups, which decreased again after 1 week. There was no significant difference between the groups 1 h after cataract surgery, though a tendency toward lower NEI scores was observed during this time point in group 3. DISCUSSION: Cataract surgery induced ocular surface staining and subjective complaints after 1 h. However, the increase in VAS score was small and probably not clinically relevant. The application of perioperative C-NAC eye drops did reduce the rate of corneal staining after cataract surgery in a clinically relevant manner.


Asunto(s)
Extracción de Catarata , Catarata , Quitosano , Síndromes de Ojo Seco , Humanos , Soluciones Oftálmicas , Acetilcisteína/uso terapéutico , Acetilcisteína/farmacología , Extracción de Catarata/efectos adversos
3.
Ophthalmic Res ; 65(4): 437-445, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35272298

RESUMEN

INTRODUCTION: The aim of this study was to compare the structure-function relationship with microperimetry and Octopus perimetry in primary open-angle glaucoma (POAG) patients with central visual field (VF) defects. METHODS: Forty eyes of 24 patients with POAG were enrolled. Circumpapillary retinal nerve fiber layer (cpRNFL) analysis measured by spectral-domain optical coherence tomography (SD-OCT) of the superotemporal, temporal, and inferotemporal optic-nerve head sectors were related to corresponding microperimetric and Octopus VF clusters using the G2 grid-pattern with dynamic strategy, respectively. The structure-function relationships of both devices were assessed via a segmented regression, as well as linear regression across overall SD-OCT cpRNFL values and outside normative (<1%) SD-OCT cpRNFL values. RESULTS: Linear and segmented regression fits were similar with both devices. Across overall cpRNFL sectorial values, structure-function relations for the superotemporal, temporal, and inferotemporal sectors were R2 = 0.176 (p = <0.001), R2 = 0.008 (p = 0.069), and R2 = 0.294 (p = <0.001) for microperimetry and R2 = 0.189 (p = <0.001), R2 = 0.020 (p = 0.002), and R2 = 0.326 (p = <0.001) for Octopus perimetry. For corresponding values outside normative limits (<1%), the relationships were R2 = 0.113 (p = <0.001), R2 = 0.001 (p = 0.836), and R2 = 0.420 (p = <0.001) for microperimetry and R2 = 0.192 (p = <0.001), R2 = 0.002, (p = 0.336), and R2 = 0.366 (p = <0.001) for Octopus perimetry. DISCUSSION/CONCLUSION: Structure-function analysis was similar for both devices. Fundus-tracking should be further evaluated in a longitudinal setting in patients affected by glaucoma.


Asunto(s)
Glaucoma de Ángulo Abierto , Octopodiformes , Animales , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Fibras Nerviosas , Células Ganglionares de la Retina , Escotoma , Tomografía de Coherencia Óptica/métodos , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales
4.
Am J Physiol Heart Circ Physiol ; 320(1): H23-H28, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33275537

RESUMEN

In neural tissues, the coupling between neural activity and blood flow is a physiological key principle in blood flow regulation. We used optical coherence tomography angiography to investigate stimulus-evoked hemodynamic responses in different microvascular layers of the human retina. Twenty-two healthy subjects were included. Vessel density before and during light stimulation was measured using optical coherence tomography angiography and assessed for the superficial, intermediate, and deep capillary plexus of the retinal circulation. Volumetric blood flow was measured using a custom-built Doppler optical coherence tomography system. Our results show that flicker stimulation induced a significant increase in the vessel density of +9.9 ± 6.7% in the superficial capillary plexus, +6.6 ± 1.7% in the intermediate capillary plexus, and +4.9 ± 2.3% in the deep capillary plexus. The hyperemic response of the superficial capillary plexus was significantly higher compared to the intermediate capillary plexus (P = 0.02) and deep capillary plexus (P = 0.002). Volumetric retinal blood flow increased by +39.9 ± 34.9% in arteries and by +29.8 ± 16.8% in veins. In conclusion, we showed a strong increase in the retinal microvascular density in response to light stimulation, with the most pronounced effect in the superficial capillary plexus. This is compatible with the hypothesis that the microvasculature exerts an important function in mediating functional hyperemia in humans.NEW & NOTEWORTHY We present vessel density alterations in response to flicker stimulation using optical coherence tomography angiography and identified the superficial capillary plexus as the layer with the most pronounced effect. This points out the physiological importance of the microvasculature in mediating functional hyperemia and suggests a fine-tuned plexus-specific mechanism to meet cellular metabolic demands.


Asunto(s)
Angiografía , Microcirculación , Microvasos/diagnóstico por imagen , Acoplamiento Neurovascular , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica , Adulto , Femenino , Voluntarios Sanos , Humanos , Luz , Masculino , Microcirculación/efectos de los fármacos , Microvasos/fisiología , Microvasos/efectos de la radiación , Estimulación Luminosa , Flujo Sanguíneo Regional , Vasos Retinianos/fisiología , Vasos Retinianos/efectos de la radiación , Adulto Joven
5.
Entropy (Basel) ; 21(3)2019 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33267037

RESUMEN

We present a model, in which quantum-collapse is supposed to be real as a result of breaking unitary symmetry, and in which we can define a notion of "becoming". We show how empirical space-time can emerge in this model, if duration is measured by light-clocks. The model opens a possible bridge between Quantum Physics and Relativity Theory and offers a new perspective on some long-standing open questions, both within and between the two theories.

6.
Entropy (Basel) ; 20(10)2018 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-33265830

RESUMEN

We construct a type of thermal quantum-clocks and show that various interesting relations between energy, entropy and geometry in space-time directly follow by partially synchronizing them in the sense of making them march in step with photon clocks.

7.
J Cataract Refract Surg ; 50(3): 295-300, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37994093

RESUMEN

PURPOSE: To investigate the flange properties of different iris hooks. SETTING: Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria. DESIGN: Laboratory study. METHODS: The flanging properties of 4 different iris hooks made from polypropylene (PP), elastic polymer (EP), and nylon were investigated with different heating distances and both with and without forceps gripping. The maximum diameter of the flanges was measured, and the shape of the flanges was evaluated. RESULTS: Although both nylon and EP iris hooks had too small flange diameters for intrascleral fixation, PP iris hooks had a sufficient flange diameter (>330 µm) and mushroom-like shape. Furthermore, in PP hooks, heating distance was directly proportional to flange diameter. CONCLUSIONS: The findings of this study suggest that only PP iris hooks are suitable for flanged intrascleral fixation, which is off-label, to secure adequate fixation.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares/métodos , Nylons , Técnicas de Sutura , Iris/cirugía , Polímeros , Esclerótica/cirugía
8.
Am J Ophthalmol ; 264: 229-234, 2024 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-38461946

RESUMEN

PURPOSE: To compare 4 different secondary intraocular lens (IOL) fixation techniques regarding the least required force to dislocate a scleral fixated 3-piece IOL in human corneoscleral donor tissue. DESIGN: Experimental laboratory investigation. METHODS: The least required dislocation force (LRDF) of 4 different secondary IOL fixation techniques, namely, the techniques using transscleral tunnels (TTs; as described by Scharioth), glued haptics (GHs; Agarwal), flanged haptics (FHs; Yamane), and bent haptic ends (BH; Behera/Bolz), were investigated using 40 three-piece IOLs (Sensar AR40) fixated to human scleral tissue. The main outcome of the study, dislocation force between different techniques, was measured with a tensiometer. RESULTS: The force needed to dislocate the haptics was highest with the FH technique and was significantly higher than with all the other techniques (GH vs FH: -1.02±0.02 N, P < .001; TT vs FH: -1.08±0.21 N, P < .001; BH vs FH: -1.00±0.25 N, P = .044). There was no significant difference regarding the dislocation force between the other techniques: GH vs TT (-0.06±0.100 N, P = .988), GH vs BH (-0.02±0.03 N, P = .60), TT vs BH (-0.08±0.04 N, P > .99). CONCLUSIONS: The FH technique as described by Yamane proved to be the strongest form of secondary IOL fixation regarding dislocation force in this in vitro study. The other fixation techniques showed significantly less resistance to axial traction.

9.
Acta Ophthalmol ; 102(1): e60-e68, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37203877

RESUMEN

PURPOSE: To evaluate the effect of vectored thermal pulsation therapy (VTPT) on the repeatability of biometry readings of two different optical biometers in patients with meibomian gland dysfunction (MGD). METHODS: Patients affected by MGD were included in this prospective, randomized, controlled, investigator-masked study. One eye was randomized to VTPT (LipiFlow®, Johnson & Johnson), and the contralateral eye served as a control. Three visits were scheduled at baseline, 2 weeks and 3 months after the treatment. The main outcome parameter of the study was the repeatability of three calculations of emmetropic intraocular lens power (EIOLP) at the 3 months visit as compared to baseline using an optical biometer (IOLMaster® 700, Carl Zeiss Meditec AG). Repeatability of different keratometry values obtained by the optical biometer and a Placido-disc topographer (MS-39®, CSO) served as secondary outcome parameters. RESULTS: Twenty-nine patients were included in the final analysis. While tear film parameters improved in the study eyes, there were no significant differences regarding the repeatability of three EIOLP measurements between baseline and 3-months-visit in both eyes (p > 0.05) and keratometry measurements in both the optical biometer and the Placido-disc topographer. Remarkably, throughout all study visits, there were some outliers regarding the repeatability of measurements. CONCLUSION: While both devices showed high repeatability regarding EIOLP and keratometry, future studies are needed to detect high-risk patients for poor repeatability.


Asunto(s)
Hipertermia Inducida , Disfunción de la Glándula de Meibomio , Humanos , Estudios Prospectivos , Córnea , Biometría
10.
Invest Ophthalmol Vis Sci ; 65(3): 20, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38470325

RESUMEN

Purpose: The purpose of this study was to investigate rod photopigment bleaching-driven intrinsic optical signals (IOS) in the human outer retina and its measurement repeatability based on a commercial optical coherence tomography (OCT) platform. Methods: The optical path length of the rod photoreceptor subretinal space (SRS), that is, the distance between signal bands of rod outer segment tips and retinal pigment epithelium, was measured in 15 healthy subjects in ambient light and during a long-duration bleaching white-light exposure. Results: On 2 identical study days (day 1 and day 2 [D1 and D2]), light stimulation resulted in a significant decrease in rod SRS by 21.3 ± 7.6% and 19.8 ± 8.5% (both P < 0.001), respectively. The test-retest reliability of the SRS maximum change of an individual subject was moderate for single measures (intraclass correlation coefficient [ICC] = 0.730, 95% confidence interval [CI] = 0.376, 0.900, P < 0.001) and good for average measures (ICC = 0.844, 95% CI = 0.546, 0.947, P < 0.001). The mean area under the stimulus response curve with values of 14.8 ± 9.4 and 15.5 ± 7.5 µm × minutes (P = 0.782) showed excellent agreement between the stimulus response on D1 and D2. Intermittent dark adaptation of the retina led to an initial increase of the SRS by 6.1% (P = 0.018) and thereafter showed a decrease toward baseline, despite continued dark adaptation. Conclusions: The data indicate the potential of commercial OCT in measuring slow IOS in the outer retina suggesting that the rod SRS could serve as a biomarker for photoreceptor function. The presented approach could provide an easily implementable clinical tool for the early detection of diseases affecting photoreceptor health.


Asunto(s)
Retina , Tomografía de Coherencia Óptica , Humanos , Reproducibilidad de los Resultados , Retina/diagnóstico por imagen , Adaptación a la Oscuridad , Segmento Externo de la Célula en Bastón
11.
Pharmaceutics ; 16(3)2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38543260

RESUMEN

PURPOSE: Inhibitors of dihydroorotate dehydrogenase (DHODH) have been found to be potent anti-inflammatory agents. Recently, a topical formulation (KIO-101 eye drops) of a DHODH inhibitor has been developed. The aim of the present study was to evaluate the safety and tolerability of KIO-101 eye drops in Healthy Volunteers (HVs) and patients with conjunctival hyperemia. METHODS: The study was carried out in a double-masked, placebo-controlled, randomized, parallel-group design with two parts. In part I, HVs received single and multiple instillations (four times daily for 12 consecutive days) of KIO-101 eye drops in ascending doses of 0.05%, 0.15%, and 0.30%, respectively. Part II was conducted in patients with conjunctival hyperemia who received 0.15% KIO-101 eye drops twice daily for 12 consecutive days. Ophthalmic and systemic safety examinations were performed on all participants. In part II, ocular hyperemia grading and an ocular surface disease index (OSDI) questionnaire were performed. RESULTS: 24 HVs participated in part I and 21 patients in part II. KIO-101 eye drops were well tolerated in all subjects. No serious adverse events (SAEs) occurred, and all AEs that were reported were transient and considered mild to moderate. In the highest dose cohort (0.30%), epistaxis occurred in two subjects after multiple instillations. In part II, after 12 days treatment with 0.15% KIO-101, conjunctival hyperemia decreased by -1.1 ± 0.27 points in the treatment and -0.6 ± 0.79 points in the placebo group (p = 0.0385). OSDI decreased from 47.9 ± 18.7 to 27.6 ± 19.13 points in the treatment group, while in the placebo group, a change from 41.3 ± 12.08 to 27.3 ± 18.63 points occurred. CONCLUSIONS: A 12-day treatment regimen with topical KIO-101 eye drops at low and mid doses was safe and well tolerated in both HVs and patients with conjunctival hyperemia. The obtained results point towards an early sign of reduction in conjunctival hyperemia.

12.
J Ocul Pharmacol Ther ; 39(6): 371-378, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37327369

RESUMEN

Purpose: This prospective, randomized, observer-masked, parallel-group study aimed to compare the effect of topical azithromycin and oral doxycycline on tear film thickness (TFT) and signs and symptoms of ocular surface disease (OSD) in patients with meibomian gland dysfunction (MGD). Methods: Patients were randomized to either receive topical azithromycin or oral doxycycline. After a baseline visit, three follow-up visits at intervals of 2 weeks were scheduled. Main outcome of the study was change in TFT as measured with ultrahigh resolution optical coherence tomography. Results: Twenty patients were included in the analysis. TFT significantly increased in both groups (P = 0.028 vs. baseline) with no difference between the groups (P = 0.096). As secondary outcomes, ocular surface disease index (OSDI) score and composite signs of OSD significantly decreased in both groups (P = 0.023 for OSDI and P = 0.016 for OSD signs vs. baseline). While eye-related adverse events (AEs) occurred more frequently in the azithromycin group, systemic AEs were more common in the doxycycline group. Conclusions: Both treatments improved signs and symptoms of OSD in patients with MGD with no difference between the groups. Due to the higher frequency of systemic side effects of doxycycline, azithromycin eye drops seem to be an alternative with comparable efficacy. Clinical Trial Registration number: NCT03162497.


Asunto(s)
Síndromes de Ojo Seco , Disfunción de la Glándula de Meibomio , Humanos , Azitromicina/efectos adversos , Doxiciclina , Disfunción de la Glándula de Meibomio/tratamiento farmacológico , Antibacterianos/farmacología , Estudios Prospectivos , Glándulas Tarsales , Lágrimas , Síndromes de Ojo Seco/tratamiento farmacológico
13.
Antibiotics (Basel) ; 12(3)2023 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-36978384

RESUMEN

BACKGROUND: Antibiotic eye drops are frequently used in clinical practice. Due to the anatomical connection via the nasolacrimal duct, it seems possible that they have an influence on the nasal/pharyngeal microbiome. This was investigated by using two different commonly used antibiotic eye drops. METHODS: 20 subjects were randomized to four groups of five subjects receiving eye drops containing gentamicin, ciprofloxacin, or, as controls, unpreserved povidone or benzalkonium chloride-preserved povidone. Nasal and pharyngeal swabs were performed before and after the instillation period. Swabs were analyzed by Illumina next-generation sequencing (NGS)-based 16S rRNA analysis. Bacterial culture was performed on solid media, and bacterial isolates were identified to the species level by MALDI-TOF MS. Species-dependent antimicrobial susceptibility testing was performed using single isolates and pools of isolates. RESULTS: Bacterial richness in the nose increased numerically from 163 ± 30 to 243 ± 100 OTUs (gentamicin) and from 114 ± 17 to 144 ± 45 OTUs (ciprofloxacin). Phylogenetic diversity index (pd) of different bacterial strains in the nasal microbiome increased from 12.4 ± 1.0 to 16.9 ± 5.6 pd (gentamicin) and from 10.2 ± 1.4 to 11.8 ± 3.1 pd (ciprofloxacin). Unpreserved povidone eye drops resulted in minimal changes in bacterial counts. Preservative-containing povidone eye drops resulted in no change. A minor increase (1-2-fold) in the minimal inhibitory concentration (MIC) was observed in single streptococcal isolates. CONCLUSIONS: Antibiotic eye drops could affect the nasal microbiome. After an instillation period of seven days, an increase in the diversity and richness of bacterial strains in the nasal microbiome was observed.

14.
Acta Ophthalmol ; 100(5): e1127-e1134, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34708544

RESUMEN

PURPOSE: The aim of this retrospective analysis was to investigate whether trabeculectomy (TRAB) and XEN® Gel Stent implantation (XEN) - both filtrating surgery techniques - can slow down the deterioration of visual field (VF) parameters considering the floor effect, which could lead to a misestimation of pre- and postoperative VF rate of progression (ROP). METHODS: Included in this study were patients with open-angle glaucoma, who underwent either TRAB or XEN® gel stent implantation and who had at least three VF tests before and after surgery, over an observation period of 13 years. The annual ROP of the mean defect (MD) and the square root of loss variance (sLV) were calculated with two different censoring thresholds: by censored regression and by ordinary least squares regression (OLSR). In addition, the diagnostic range of sLV was calculated. RESULTS: 48 eyes of 39 glaucoma patients were included in the study. The annual rate of MD progression was significantly reduced by filtering surgery when calculating the yearly ROP using OLSR (p = 0.006) and by censoring values exceeding a precalculated cut-off of 14.20 dB (p = 0.041) and a cut-off from the literature of 15.00 dB (p = 0.028). On average, the MD was impacted by a significant floor effect of 14.20 dB (95% CI: 12.83-15.56), corresponding to 17.7/59 absolute defects or 29.9% of the whole VF. When applying both OLSR and censored regression, the annual rate of sLV progression did not show a significant difference. The sLV showed a diagnostic boundary at a MD of 15.78 dB. CONCLUSION: This study shows that filtering surgery can reduce the progression of VF in patients with open-angle glaucoma, especially those whose disease develops aggressively. This is valid even if the floor effect in advanced cases is compensated by censored regression. On average, the ROP of MD is affected by a significant floor effect at about 29.9% absolute loss of the whole VF.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Progresión de la Enfermedad , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/cirugía , Humanos , Presión Intraocular , Estudios Retrospectivos , Pruebas del Campo Visual , Campos Visuales
15.
Ann N Y Acad Sci ; 1511(1): 133-141, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35029314

RESUMEN

We compare the focal structure-function correlation of structural measurements of peripapillary retinal nerve fiber layer thickness (RNFL-T) using optical coherence tomography (OCT), capillary density (CD) measurements using OCT-angiography (OCT-A), or a combination of both, with visual field deviation (VFD) in early to advanced glaucoma. Primary open angle glaucoma patients (n = 46, mean ± SD age: 67 ± 10 years; VF mean deviation: -10.41 ± 6.76 dB) were included in this cross-sectional study. We performed 30-2 standard automated perimetry OCT (3.5-mm diameter ring scan) and 15°×15° OCT-A (superficial vascular complex slab). Based on a nerve fiber trajectory model, each VF test spot was assigned to an OCT-A wedge and an OCT ring-sector. Two univariate linear models (Mv and Mt ) using either CD-based vascular (Mv ) or RNFL-T-based thickness information (Mt ) and one multivariate model using both (Mv:t ) were compared in their associations with measured focal VFD, which were higher for the multivariate model Mv:t (mean ± SD correlation coefficient: 0.710 ± 0.086) than for either nested model (0.627 ± 0.078 for Mv and 0.578 ± 0.095 for Mt ). Using a focal visual field approach, the combination of RNFL-T and CD showed better structure-function correlations than thickness or vascular information only.


Asunto(s)
Glaucoma de Ángulo Abierto , Pruebas del Campo Visual , Anciano , Estudios Transversales , Humanos , Persona de Mediana Edad , Fibras Nerviosas , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica/métodos , Trastornos de la Visión , Pruebas del Campo Visual/métodos , Campos Visuales
16.
EPMA J ; 13(1): 107-123, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35265228

RESUMEN

Background/aims: Concerning healthcare approaches, a paradigm change from reactive medicine to predictive approaches, targeted prevention, and personalisation of medical services is highly desirable. This raises demand for biomarker signatures that support the prediction and diagnosis of diseases, as well as monitoring strategies regarding therapeutic efficacy and supporting individualised treatments. New methodological developments should preferably rely on non-invasively sampled biofluids like sweat and tears in order to provide optimal compliance, reduce costs, and ensure availability of the biomaterial. Here, we have thus investigated the metabolic composition of human tears in comparison to finger sweat in order to find biofluid-specific marker molecules derived from distinct secretory glands. The comprehensive investigation of numerous biofluids may lead to the identification of novel biomarker signatures. Moreover, tear fluid analysis may not only provide insight into eye pathologies but may also be relevant for the prediction and monitoring of disease progression and/ or treatment of systemic disorders such as type 2 diabetes mellitus. Methods: Sweat and tear fluid were sampled from 20 healthy volunteers using filter paper and commercially available Schirmer strips, respectively. Finger sweat analysis has already been successfully established in our laboratory. In this study, we set up and evaluated methods for tear fluid extraction and analysis using high-resolution mass spectrometry hyphenated with liquid chromatography, using optimised gradients each for metabolites and eicosanoids. Sweat and tears were systematically compared using statistical analysis. As second approach, we performed a clinical pilot study with 8 diabetic patients and compared them to 19 healthy subjects. Results: Tear fluid was found to be a rich source for metabolic phenotyping. Remarkably, several molecules previously identified by us in sweat were found significantly enriched in tear fluid, including creatine or taurine. Furthermore, other metabolites such as kahweol and various eicosanoids were exclusively detectable in tears, demonstrating the orthogonal power for biofluid analysis in order to gain information on individual health states. The clinical pilot study revealed that many endogenous metabolites that have previously been linked to type 2 diabetes such as carnitine, tyrosine, uric acid, and valine were indeed found significantly up-regulated in tears of diabetic patients. Nicotinic acid and taurine were elevated in the diabetic cohort as well and may represent new biomarkers for diabetes specifically identified in tear fluid. Additionally, systemic medications, like metformin, bisoprolol, and gabapentin, were readily detectable in tears of patients. Conclusions: The high number of identified marker molecules found in tear fluid apparently supports disease development prediction, developing preventive approaches as well as tailoring individual patients' treatments and monitoring treatment efficacy. Tear fluid analysis may also support pharmacokinetic studies and patient compliance control. Supplementary Information: The online version contains supplementary material available at 10.1007/s13167-022-00272-7.

17.
Front Med (Lausanne) ; 9: 1025853, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36438055

RESUMEN

Aims/Hypothesis: There is evidence that diabetes is accompanied by a break-down of functional hyperemia, an intrinsic mechanism of neural tissues to adapt blood flow to changing metabolic demands. However, to what extent functional hyperemia is altered in different stages of diabetic retinopathy (DR) in patients with type II diabetes is largely unknown. The current study set out to investigate flicker-induced retinal blood flow changes in patients with type II diabetes at different stages of DR. Materials and methods: A total of 76 subjects were included in the present parallel-group study, of which 56 had diabetes with either no DR or different stages of non-proliferative DR (n = 29 no DR, 12 mild DR, 15 moderate to severe DR). In addition, 20 healthy subjects were included as controls. Retinal blood flow was assessed before and during visual stimulation using a combined measurement of retinal vessel calibers and blood velocity by the means of Doppler optical coherence tomography (OCT). To measure systemic autonomic nervous system function, heart rate variability (HRV) was assessed using a short-term orthostatic challenge test. Results: In healthy controls, retinal blood flow increased by 40.4 ± 27.2% during flicker stimulation. Flicker responses in patients with DR were significantly decreased depending on the stage of the disease (no DR 37.7 ± 26.0%, mild DR 26.2 ± 28.2%, moderate to severe DR 22.3 ± 13.9%; p = 0.035, ANOVA). When assessing systemic autonomous neural function using HRV, normalized low frequency (LF) spectral power showed a significantly different response to the orthostatic maneuver in diabetic patients compared to healthy controls (p < 0.001). Conclusion/Interpretation: Our study indicates that flicker induced hyperemia is reduced in patients with DR compared to healthy subjects. Further, this impairment is more pronounced with increasing severity of DR. Further studies are needed to elucidate mechanisms behind the reduced hyperemic response in patients with type II diabetes. Clinical trial registration: [https://clinicaltrials.gov/], identifier [NCT03 552562].

18.
Diabetes ; 71(12): 2677-2684, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36107468

RESUMEN

The aim of this cross-sectional study was to assess retinal oxygen metabolism in patients with type 2 diabetes and different stages of nonproliferative diabetic retinopathy (DR) (n = 67) compared with healthy control subjects (n = 20). Thirty-four patients had no DR, 15 had mild DR, and 18 had moderate to severe DR. Retinal oxygen saturation in arteries and veins was measured using the oxygen module of a retinal vessel analyzer. Total retinal blood flow (TRBF) was measured using a custom-built Doppler optical coherence tomography system. Retinal oxygen extraction was calculated from retinal oxygen saturation and TRBF. Arteriovenous difference in oxygen saturation was highest in healthy subjects (34.9 ± 7.5%), followed by patients with no DR (32.5 ± 6.3%) and moderate to severe DR (30.3 ± 6.5%). The lowest values were found in patients with mild DR (27.3 ± 8.0%, P = 0.010 vs. healthy subjects). TRBF tended to be higher in patients with no DR (40.1 ± 9.2 µL/min) and mild DR (41.8 ± 15.0 µL/min) than in healthy subjects (37.2 ± 5.7 µL/min) and patients with moderate to severe DR (34.6 ± 10.4 µL/min). Retinal oxygen extraction was the highest in healthy subjects (2.24 ± 0.57 µL O2/min), followed by patients with no DR (2.14 ± 0.6 µL O2/min), mild DR (1.90 ± 0.77 µL O2/min), and moderate to severe DR (1.78 ± 0.57 µL O2/min, P = 0.040 vs. healthy subjects). These results indicate that retinal oxygen metabolism is altered in patients with type 2 diabetes. Furthermore, retinal oxygen extraction decreases with increasing severity of DR.


Asunto(s)
Diabetes Mellitus Tipo 2 , Retinopatía Diabética , Humanos , Retinopatía Diabética/metabolismo , Oxígeno/metabolismo , Estudios Transversales , Retina/metabolismo , Vasos Retinianos/metabolismo , Tomografía de Coherencia Óptica/métodos
19.
Acta Ophthalmol ; 100(6): e1272-e1279, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34881512

RESUMEN

PURPOSE: To investigate the response of the superficial and deep capillary plexuses to hyperoxia and hypoxia using optical coherence tomography angiography (OCT-A) and retinal vessel analyzer. METHODS: Twenty-four healthy volunteers participated in this randomized, double-masked, cross-over study. For each subject, two study days were scheduled: on one study day, hyperoxia was induced by breathing 100% oxygen whereas on the other study day, hypoxia was induced by breathing a mixture of 88% nitrogen and 12% oxygen. Perfusion density was calculated in the superficial vascular plexus (SVP) and the deep capillary plexus (DCP), using OCT-A before (normal breathing) and during breathing of the gas mixtures. Retinal vessel calibres in major retinal vessels were measured using a dynamic vessel analyzer. RESULTS: During 100% oxygen breathing, a significant decrease in DCP perfusion density from 41.7 ± 2.4 a.u to 35.6 ± 3.1 a.u. (p < 0.001) was observed, which was accompanied by a significant decrease in vessel diameters in major retinal arteries and veins (p < 0.001 each). No significant change in perfusion density in the SVP occurred (p = 0.33). In contrast, during hypoxia, perfusion density in the SVP significantly increased from 34.4 ± 3.0 a.u. to 37.1 ± 2.2 a.u. (p < 0.001), while it remained stable in the DCP (p = 0.25). A significant increase in retinal vessel diameters was found (p < 0.01). Systemic oxygen saturation correlated negatively with perfusion density in the SVP and the DCP and retinal vessel diameters (p < 0.005 each). CONCLUSION: Our results show that systemic hyperoxia induces a significant decrease in vessel density in the DCP, while hypoxia leads to increased vessel density limited to the SVP. These results indicate that the retinal circulation shows the ability to adapt its blood flow to metabolic changes with high local resolution dependent on the capillary plexus.


Asunto(s)
Oftalmopatías , Hiperoxia , Estudios Cruzados , Angiografía con Fluoresceína/métodos , Humanos , Hipoxia , Oxígeno , Vasos Retinianos , Tomografía de Coherencia Óptica/métodos
20.
Sci Rep ; 11(1): 23406, 2021 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-34862438

RESUMEN

At the moment, cataract, which is the opacification of the eye's lens, can only be treated by surgery. In order to develop and test new pharmacological treatment strategies for the disease, there is a need for an appropriate in vitro model using ex vivo animal lenses. In this study, porcine lenses were incubated in either culture medium, glucose, triamcinolone acetonide, sodium chloride, hydrogen peroxide, sodium selenite, neutral buffered formalin, or were exposed to microwave heating to experimentally induce lens opacification. Changes in the lens morphology, weight, size, and elasticity were monitored 7 days after treatment. The fastest induction of dense opacification was seen in lenses exposed to sodium chloride, neutral buffered formalin, and microwave heating. No change in the size and weight of the lenses were detected, whereas loss in elasticity could be detected in lenses treated with formalin solution or microwave heating. Thus, neutral buffered formalin- and microwave-treated ex vivo porcine lenses seem to be a suitable model for mature cataracts, whereas hypertonic sodium chloride may be useful for studies on osmolarity-induced lens opacification.


Asunto(s)
Catarata/patología , Medios de Cultivo/farmacología , Cristalino/patología , Microondas/efectos adversos , Animales , Catarata/etiología , Medios de Cultivo/química , Modelos Animales de Enfermedad , Cristalino/efectos de los fármacos , Cristalino/efectos de la radiación , Tamaño de los Órganos/efectos de los fármacos , Tamaño de los Órganos/efectos de la radiación , Concentración Osmolar , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA