Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Indian Prosthodont Soc ; 14(Suppl 1): 273-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26199530

RESUMEN

The present clinical report describes the prosthodontic management for a patient with uncontrolled bleeding and diabetes mellitus treated with a maxillary complete denture and a mandibular partial fixed dental prosthesis designed to interface with a removable cast framework partial denture retained by 2 ERA attachments. This approach was undertaken to improve both retention and stability of the distal extension Kennedy Class I removable partial denture. The rehabilitation provided better anterior esthetics than if treated with a conventional clasp retained removable partial denture, by employing a simple, practical design and offering a significant biomechanical advantages, restoring both oral health and function. Thus, this treatment modality, involving an ERA system and transfixation in fixed crowns, is an effective treatment and can be indicated as a clinical alternative for edentulous and partially edentulous patients with systemic disorders or for patients in economic situations that might preclude implant-based rehabilitation.

2.
Gen Dent ; 58(4): e168-71, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20591765

RESUMEN

An implant-retained overdenture is less expensive than a fixed implant-retained prosthesis; however, using ball attachments on abutments that are nonparallel and/or outside the path of insertion may result in loss of retention. As described in this case report, alignment devices can be used as a mandibular overdenture retainer to diminish the lack of parallelism between two implants. The treatment plan involved the use of an alignment device on each implant to ensure correct alignment among ball attachments and its retentive component. These devices can be used to fabricate overdentures retained by implants that are misaligned by as much as 14 degrees.


Asunto(s)
Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado/instrumentación , Dentadura Completa Inferior , Prótesis de Recubrimiento , Arcada Edéntula/rehabilitación , Adulto , Pilares Dentales , Implantación Dental Endoósea/instrumentación , Implantación Dental Endoósea/métodos , Implantes Dentales , Retención de Dentadura , Humanos , Masculino , Mandíbula , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA