RESUMEN
Cone-beam computed tomography (CBCT) was first used in dental and maxillofacial radiology (DMFR) at the end of the 1990s. Since then, it has been successfully established as the standard three-dimensional radiographic imaging technique in DMFR, with a wide variety of applications in this field. This manuscript briefly reviews the background information on the technology and summarises available data on effective dose and dose optimisation. In addition, typical clinical applications and indications of the technique in DMFR are presented.
Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Huesos Faciales/diagnóstico por imagen , Imagenología Tridimensional/métodos , Maxilar/diagnóstico por imagen , Enfermedades Estomatognáticas/diagnóstico , Humanos , Dosis de RadiaciónRESUMEN
OBJECTIVES: To investigate diagnostic accuracy of panoramic radiography in detecting maxillary sinus floor septa by means of a multi-observer receiver operating characteristic (ROC) analysis and a standardized protocol for reporting (STARD protocol; Clin Chem 49(1):1-6, 2003). MATERIAL AND METHODS: From our database, 25 cone beam computed tomographies (CBCTs) were selected with one maxillary sinus floor septum (height ≥ 2.5 mm). For the same patient, a recent panoramic radiograph (PAN) had to be available in the database. As controls, 28 CBCTs plus corresponding PANs without evidence of a sinus septum were selected. Using the CBCTs as ground truth, 17 observers from our dental school on a five-point confidence scale rated both sinuses in all 53 PANs with respect to presence/absence of a sinus septum. Areas beneath ROC curves (Az-values), sensitivity/specificity (SNT/SPF), positive/negative predictive values (PPV, NPV), and positive/negative likelihood ratios (LR+, LR-) were computed for each observer and pooled over all observers. Inter-rater reproducibility was assessed by means of the intraclass coefficient (ICC) using a two-way random effects model. RESULTS: A pooled Az-value of 0.839 was observed (SNT 84.6%, SPF 73.5%). PPV ranged between 0.492 and 0.824 (median 0.627) and NPV between 0.838 and 0.976 (median 0.917). A median LR+ of 3.567 was computed (LR- median 0.193). Inter-rater reliability revealed an ICC of 0.55 (95% confidence interval 0.48 to 0.62). CONCLUSIONS: Our results indicate that PAN is a moderately accurate method for sinus elevation planning for the purpose of septum detection. Ruling out a septum by PAN seems to work more accurately than ruling in. CLINICAL RELEVANCE: For the purpose of maxillary sinus floor septa detection, panoramic radiography can be relatively safely advocated, particularly for judgment of a septum-free sinus.
Asunto(s)
Tomografía Computarizada de Haz Cónico , Seno Maxilar/diagnóstico por imagen , Radiografía Panorámica , Humanos , Curva ROC , Sensibilidad y Especificidad , Elevación del Piso del Seno MaxilarRESUMEN
Significant land use changes from natural/agricultural to urban land uses have been proposed within the Mpushini/Mkhondeni sub-catchments of the uMngeni Catchment in South Africa. A better understanding of the influences which such land use changes are likely to have on hydrological flows, is required, in order to make informed land use decisions for a sustainable future. As a point of departure, an overview of linkages between urbanisation and hydrological flow responses within this sub-humid study area is given. The urban characteristics of increased impervious areas and the potential return flows from transfers of potable water from outside the catchment were identified as being important in regard to hydrological flow responses. A methodology was developed to model urban response scenarios with urban characteristics as variables, using the daily time-step process based ACRU model. This is a hydrological multi-process model and not an urban hydraulic model and it addresses the landscape as well as the channel components of a catchment, and in addition to runoff components includes evaporation and transpiration losses as outputs. For the study area strong links between proposed urbanisation and hydrological resource flow responses were found, with increases in stormflows, together with increased and more regulated baseflows, and with impacts varying markedly between dry or wet years and by season. The impacts will depend on the fractions of impervious areas, whether or not these are connected to permeable areas, the amount of imported water and water system leaks. Furthermore, the urban hydrological impacts were found to be relatively greater in more arid than humid areas because of changes in the rainfall to runoff conversion. Flow changes due to urbanisation are considered to have important environmental impacts, requiring mitigation. The methodology used in this paper could be used for other urbanising areas.
Asunto(s)
Agricultura , Urbanización , Abastecimiento de Agua , Hidrología , SudáfricaRESUMEN
Materials with strong correlations are prone to spin and charge instabilities, driven by Coulomb, magnetic, and lattice interactions. In materials that have significant localized and itinerant spins, it is not obvious which will induce order. We combine electrical transport, X-ray magnetic diffraction, and photoemission studies with band structure calculations to characterize successive antiferromagnetic transitions in GdSi. GdSi has both sizable local moments and a partially nested Fermi surface, without confounding contributions from orbital effects. We identify a route to incommensurate order where neither type of moment dominates, but is rooted in cooperative feedback between them. The nested Fermi surface of the itinerant electrons induces strong interactions between local moments at the nesting vector, whereas the ordered local moments in turn provide the necessary coupling for a spin-density wave to form among the itinerant electrons. This mechanism echoes the cooperative interactions between electrons and ions in charge-density-wave materials, and should be germane across a spectrum of transition-metal and rare-earth intermetallic compounds.
RESUMEN
BACKGROUND: The retinoid acitretin, which has been approved as an effective therapy for severe keratinization disorders, is highly teratogenic, and exposure in the first trimester of pregnancy is associated with the risk of miscarriage and various malformations, including congenital heart defects. Cardiac conduction system disorders have not been described so far. CASE REPORT: A 24-year-old woman was treated with acitretin for dyskeratosis follicularis until pregnancy was diagnosed at 12 weeks of gestation. The female infant was born after 35 weeks gestation by cesarean section because of intermittent fetal bradycardia. The baby was vigorous at birth (Apgar 9, 10, 10 at 1, 5 and 10 min) but displayed intermittent third-degree atrioventricular block. A search for maternal autoantibodies and viral infections gave negative findings. CONCLUSION: The spectrum of disorders caused by intrauterine retinoid exposure appears to include atrioventricular conduction failure.
Asunto(s)
Bloqueo Atrioventricular/inducido químicamente , Bloqueo Atrioventricular/congénito , Efectos Tardíos de la Exposición Prenatal/inducido químicamente , Efectos Tardíos de la Exposición Prenatal/diagnóstico , Retinoides/efectos adversos , Adulto , Bloqueo Atrioventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Recién Nacido , Enfermedades del Recién Nacido/inducido químicamente , Enfermedades del Recién Nacido/diagnóstico , EmbarazoRESUMEN
Acceleration of particles by intense laser-plasma interactions represents a rapidly evolving field of interest, as highlighted by the recent demonstration of laser-driven relativistic beams of monoenergetic electrons. Ultrahigh-intensity lasers can produce accelerating fields of 10 TV m(-1) (1 TV = 10(12) V), surpassing those in conventional accelerators by six orders of magnitude. Laser-driven ions with energies of several MeV per nucleon have also been produced. Such ion beams exhibit unprecedented characteristics--short pulse lengths, high currents and low transverse emittance--but their exponential energy spectra have almost 100% energy spread. This large energy spread, which is a consequence of the experimental conditions used to date, remains the biggest impediment to the wider use of this technology. Here we report the production of quasi-monoenergetic laser-driven C5+ ions with a vastly reduced energy spread of 17%. The ions have a mean energy of 3 MeV per nucleon (full-width at half-maximum approximately 0.5 MeV per nucleon) and a longitudinal emittance of less than 2 x 10(-6) eV s for pulse durations shorter than 1 ps. Such laser-driven, high-current, quasi-monoenergetic ion sources may enable significant advances in the development of compact MeV ion accelerators, new diagnostics, medical physics, inertial confinement fusion and fast ignition.
RESUMEN
We report an experimental determination of the dispersion of the soft phonon mode along [100] in uranium as a function of pressure. The energies of these phonons increase rapidly, with conventional behavior found by 20 GPa, as predicted by recent theory. New calculations demonstrate the strong pressure (and momentum) dependence of the electron-phonon coupling, whereas the Fermi-surface nesting is surprisingly independent of pressure. This allows a full understanding of the complex phase diagram of uranium and the interplay between the charge-density wave and superconductivity.
RESUMEN
In the daily practice of external post-mortem examinations and dealing with surviving dependents, striking failures can be observed regularly, pointing to an increased demand for training of the various professional groups involved. In this study, the experience gained from using simulation mannequins and actors for post-mortem examination training in medical students and police officers are presented. Since 2017, a training station has been offered at the Medical Faculty of the Technical University of Dresden (Germany) for practicing examinations in death scene and establishing communication with grieving relatives. It is conducted in small groups of up to 5 people, both for medical students and for police officers and police recruits. These courses are evaluated by means of questionnaires including 3 and 11 items respectively for the different groups. The questionnaires have been completed by 679 medical students and 67 police participants. Both groups of participants evaluated their previous experience as average. They assessed the course as having a high degree of practical and professional relevance. The didactic transfer of the teaching contents and its competent support were rated remarkably positive by the participants. Additionally, the police group reported high rates of approval for the use of feedback, the learning effect, and the appropriateness of the group size. The establishment and continuation of the simulation-based external post-mortem examination in the form of small-group teaching is associated with a considerable expenditure of equipment, material and personnel. In addition, its implementation requires sound cooperation structures. On the other hand, introduction and continuation of these types of additional teaching and learning methods, with a large practical component, can increase confidence in daily practice, and thus improve the quality of external post-mortem examination. Ultimately, this can also improve the cooperation between forensic medicine and the investigating authorities.
Asunto(s)
Medicina Legal/educación , Maniquíes , Policia/educación , Entrenamiento Simulado , Estudiantes de Medicina , Educación de Pregrado en Medicina , Alemania , Humanos , Evaluación de Programas y Proyectos de Salud , Encuestas y CuestionariosRESUMEN
We present an angle-resolved photoemission spectroscopy study of the electronic structure of SnTe and compare the experimental results to ab initio band structure calculations as well as a simplified tight-binding model of the p bands. Our study reveals the conjectured complex Fermi surface structure near the L points showing topological changes in the bands from disconnected pockets, to open tubes, and then to cuboids as the binding energy increases, resolving lingering issues about the electronic structure. The chemical potential at the crystal surface is found to be 0.5 eV below the gap, corresponding to a carrier density of p=1.14 × 10(21) cm(-3) or 7.2 × 10(-2) holes per unit cell. At a temperature below the cubic-rhombohedral structural transition a small shift in spectral energy of the valance band is found, in agreement with model predictions.
RESUMEN
Since the activity of several conventional anticancer drugs is restricted by resistance mechanisms and dose-limiting side-effects, the design of nanocarriers seems to be an efficient and promising approach for drug delivery. Their chemical and mechanical stability and their possible multifunctionality render tubular nanomaterials, such as carbon nanotubes (CNTs) and carbon nanofibres (CNFs), promising delivery agents for anticancer drugs. The goal of the present study was to investigate CNTs and CNFs in order to deliver carboplatin in vitro. No significant intrinsic toxicity of unloaded materials was found, confirming their biocompatibility. Carboplatin was loaded onto CNTs and CNFs, revealing a loading yield of 0.20 mg (CNT-CP) and 0.13 mg (CNF-CP) platinum per milligram of material. The platinum release depended on the carrier material. Whereas CNF-CP marginally released the drug, CNT-CP functioned as a drug depot, constantly releasing up to 68% within 14 days. The cytotoxicity of CNT-CP and CNF-CP in urological tumour cell lines was dependent on the drug release. CNT-CP was identified to be more effective than CNF-CP concerning the impairment of proliferation and clonogenic survival of tumour cells. Moreover, carboplatin, which was delivered by CNT-CP, exhibited a higher anticancer activity than free carboplatin.
Asunto(s)
Apoptosis/efectos de los fármacos , Carboplatino/farmacocinética , Proliferación Celular/efectos de los fármacos , Sistemas de Liberación de Medicamentos/métodos , Nanotubos de Carbono/química , Carboplatino/química , Carboplatino/farmacología , Línea Celular Tumoral , Preparaciones de Acción Retardada , Ensayos de Selección de Medicamentos Antitumorales , Estabilidad de Medicamentos , Humanos , Ensayo de Materiales , Nanofibras/química , Nanofibras/ultraestructura , Nanotubos de Carbono/ultraestructura , Neoplasias/tratamiento farmacológico , Ensayo de Tumor de Célula MadreRESUMEN
To investigate potential correlations between objective CBCT image parameters and accuracy in endodontic working length determination ex vivo. Contrast-to-noise ratio (CNR) and spatial resolution (SR) as fundamental objective image parameters were examined using specific phantoms in seven different CBCT machines. Seven experienced observers were instructed and calibrated. The order of the CBCTs was randomized for each observer and observation. To assess intra-operator reproducibility, the procedure was repeated within six weeks with a randomized order of CBCT images. Multivariate analysis (MANOVA) did not reveal any influence of the combined image quality factors CNR and SR on measurement accuracy. Inter-operator reproducibility as assessed between the two observations was poor, with a mean intra-class correlation (ICC) of 0.48 (95%-CI 0.38, 0.59) for observation No. 1. and 0.40 (95%-CI 0.30, 0.51) for observation No. 2. Intra-operator reproducibility pooled over all observers between both observations was only moderate, with a mean ICC of 0.58 (95%-CI 0.52 to 0.64). Within the limitations of the study, objective image quality measures and exposure parameters seem not to have a significant influence on accuracy in determining endodontic root canal lengths in CBCT scans. The main factor of variance is the observer.
Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tomografía Computarizada de Haz Cónico Espiral/métodosRESUMEN
The study compared diagnostic performances of 2 different image compression methods: JPEG (discrete cosine transform; Joint Photographic Experts Group compression standard) versus JPEG2000 (discrete wavelet transform), both at a compression ratio of 12:1, from the original uncompressed TIFF radiograph with respect to the detection of non-cavitated carious lesions. Therefore, 100 approximal surfaces of 50 tooth pairs were evaluated on the radiographs by 10 experienced observers using a 5-point confidence scale. Observations were carried out on a standardized viewing monitor under subdued light conditions. The proportion of diseased surfaces was balanced to approximately 50% to avoid bias. True caries status was assessed by serial ground sectioning and microscopic evaluation. A non-parametric receiver operating characteristic analysis revealed non-significant differences between the 3 image modalities, as computed from the critical ratios z not exceeding +/-2 (JPEG/JPEG2000, z = -0.0339; TIFF/JPEG2000, z = 0.251;TIFF/JPEG, z = 0.914). The mean area beneath the curve was highest for TIFF (0.604) followed by JPEG2000 (0.593) and JPEG (0.591). Both intra-rater and inter-rater agreement were significantly higher for TIFF (kappa(intra) = 0.52; kappa(inter) = 0.40) and JPEG2000 images (kappa(intra) = 0.49; kappa(inter) = 0.38) than for JPEG images (kappa(intra) = 0.33; kappa(inter) = 0.35). Our results indicate that image compression with typical compression algorithms at rates yielding storage sizes of around 50 kB is sufficient even for the challenging task of radiographic detection of non-cavitated carious approximal lesions.
Asunto(s)
Compresión de Datos/métodos , Caries Dental/diagnóstico por imagen , Radiografía Dental Digital , Algoritmos , Caries Dental/patología , Esmalte Dental/diagnóstico por imagen , Esmalte Dental/patología , Dentina/diagnóstico por imagen , Dentina/patología , Diagnóstico Diferencial , Humanos , Microscopía , Microtomía , Variaciones Dependientes del Observador , Curva ROC , Sensibilidad y EspecificidadAsunto(s)
Brotes de Enfermedades , Contaminación de Alimentos/análisis , Inocuidad de los Alimentos , Intoxicación Alimentaria por Salmonella/epidemiología , Salmonella enteritidis/aislamiento & purificación , Adolescente , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios de Cohortes , Heces/microbiología , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Tipificación Molecular , Reacción en Cadena de la Polimerasa , Polimorfismo Genético , Intoxicación Alimentaria por Salmonella/diagnóstico , Intoxicación Alimentaria por Salmonella/microbiología , Salmonella enteritidis/genética , Encuestas y Cuestionarios , Adulto JovenRESUMEN
The aim of this review is to interpret recent studies in which molecular methods were used to identify and characterize prokaryotes in lake sediments and related habitats. In the first part studies based on the phylogenetic diversity of prokaryotes found in lacustrine habitats are summarized. The application of various cultivation-independent methods for the characterization of distinct groups of sediment bacteria is exemplified with morphologically conspicuous, colorless sulfur bacteria in the second part of this review. Finally, traditional and recently developed methods are described which could be used for linking the function of microbial populations with their identification. The potential of these approaches for the study of lake sediments is discussed in order to give a perspective for future studies in this habitat.
Asunto(s)
Bacterias/clasificación , Ecosistema , Agua Dulce/microbiología , Sedimentos Geológicos/microbiología , Bacterias/genética , Bacterias/crecimiento & desarrollo , Técnicas Bacteriológicas/métodos , ADN Bacteriano/análisis , ADN Bacteriano/genética , ADN Ribosómico/análisis , ADN Ribosómico/genética , Filogenia , ARN Ribosómico/genéticaRESUMEN
Spatial resolution is one of the most important parameters objectively defining image quality, particularly in dental imaging, where fine details often have to be depicted. Here, we review the current status on assessment parameters for spatial resolution and on published data regarding spatial resolution in CBCT images. The current concepts of visual [line-pair (lp) measurements] and automated [modulation transfer function (MTF)] assessment of spatial resolution in CBCT images are summarized and reviewed. Published measurement data on spatial resolution in CBCT are evaluated and analysed. Effective (i.e. actual) spatial resolution available in CBCT images is being influenced by the two-dimensional detector, the three-dimensional reconstruction process, patient movement during the scan and various other parameters. In the literature, the values range between 0.6 and 2.8 lp mm(-1) (visual assessment; median, 1.7 lp mm(-1)) vs MTF (range, 0.5-2.3 cycles per mm; median, 2.1 lp mm(-1)). Spatial resolution of CBCT images is approximately one order of magnitude lower than that of intraoral radiographs. Considering movement, scatter effects and other influences in real-world scans of living patients, a realistic spatial resolution of just above 1 lp mm(-1) could be expected.
Asunto(s)
Tomografía Computarizada de Haz Cónico/normas , Intensificación de Imagen Radiográfica/normas , Radiografía Dental/normas , Artefactos , Tomografía Computarizada de Haz Cónico/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Imagenología Tridimensional/normas , Radiografía Dental/instrumentaciónRESUMEN
PURPOSE: Histological verification of pulmonary lesions is important to ensure correct treatment. Computed tomographic (CT) transthoracic core biopsy is a well-established procedure for this. Comparison of available studies is difficult though, as technical and patient characteristics vary. Using a standardized biopsy technique, we evaluated our results for CT-guided coaxial core biopsy in a semi-automatic technique. MATERIALS AND METHODS: Within 2 years, 664 consecutive transpulmonary biopsies were analyzed retrospectively. All interventions were performed using a 17/18G semi-automatic core biopsy system (4 to 8 specimens). The incidence of complications and technical and patient-dependent risk factors were evaluated. RESULTS: Comparing the histology with the final diagnosis, the sensitivity was 96.3%, and the specificity was 100%. 24 procedures were not diagnostic. In all others immunohistological staining was possible. The main complication was pneumothorax (PT, 21.7%), with chest tube insertion in 6% of the procedures (n = 40). Bleeding without therapeutic consequences was seen in 43 patients. There was no patient mortality. The rate of PT with chest tube insertion was 9.6% in emphysema patients and 2.8% without emphysema (p = 0.001). Smokers with emphysema had a 5 times higher risk of developing PT (p = 0.001). Correlation of tumor size or biopsy angle and the risk of PT was not significant. The risk of developing a PT was associated with an increasing intrapulmonary depth of the lesion (p = 0.001). CONCLUSION: CT-guided, semiautomatic coaxial core biopsy of the lung is a safe diagnostic procedure. The rate of major complications is low, and the sensitivity and specificity of the procedure are high. Smokers with emphysema are at a significantly higher risk of developing pneumothorax and should be monitored accordingly. KEY POINTS: Using an 18G core biopsy system with 6 specimens will allow immunohistological staining with high sensitivity and specificity. Smokers with emphysema are at a significantly higher risk of developing a pneumothorax.
Asunto(s)
Biopsia con Aguja Gruesa/efectos adversos , Biopsia con Aguja Gruesa/instrumentación , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/instrumentación , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Gruesa/métodos , Femenino , Humanos , Enfermedad Iatrogénica , Biopsia Guiada por Imagen/métodos , Pulmón/patología , Neoplasias Pulmonares/secundario , Masculino , Persona de Mediana Edad , Neumotórax/etiología , Neumotórax/terapia , Valor Predictivo de las Pruebas , Adulto JovenRESUMEN
The RPII15 gene product of Drosophila melanogaster, which has recently been identified by sequence comparison, possesses a high similarity to subunit 9 of yeast RNA polymerase II. Using the polymerase chain reaction the coding region of RPII15 was isolated from genomic DNA of adult flies. Sequence analysis shows four amino acid substitutions in comparison to the previously reported sequence. Antisera were generated against bacterially expressed RPII15 and were used for immunoblotting experiments with RNA polymerase II of Drosophila melanogaster. This analysis identified the M(r) 15,000 subunit 9 as gene product of RPII15.
Asunto(s)
Drosophila melanogaster/genética , ARN Polimerasa II/genética , Secuencia de Aminoácidos , Animales , Secuencia de Bases , Proteínas Portadoras/genética , Drosophila melanogaster/enzimología , Electroforesis en Gel de Poliacrilamida , Expresión Génica , Immunoblotting , Proteínas de Unión a Maltosa , Datos de Secuencia Molecular , Reacción en Cadena de la Polimerasa , ARN Polimerasa II/química , Proteínas Recombinantes de Fusión/aislamiento & purificación , Proteínas Recombinantes de Fusión/metabolismoRESUMEN
Both depressed left ventricular ejection fraction and ventricular arrhythmias have been associated with a poor prognosis following acute myocardial infarction. To assess the relative role of each of these parameters in predicting mortality in the early period after hospitalization for myocardial infarction, 24 hour ambulatory electrocardiographic tape recordings and gated cardiac blood pool scans were obtained in 81 patients approximately two weeks after their admission to the hospital for myocardial infarction. Lown class 0 to II ventricular premature contractions during this period were classified as uncomplicated ventricular arrhythmias and Lown class III to V ventricular premature contractions were classified as complicated ventricular arrhythmias. Ejection fraction was calculated from biplane images of gated cardiac blood pool scans. In 35 patients the ejection fraction was greater than or equal to 0.40; only three of these had complicated ventricular arrhythmias. In 45 patients the ejection fraction was less than 0.40; 26 of these had complicated ventricular arrhythmias. Eight patients had documented ventricular fibrillation or instantaneous death during a mean 7.0 moonth (range 2 to 16 months) follow-up period outside the hospital. Although the number of patients studied was small, and there were only eight sudden deaths, life table analysis projected a one year mortality of 66 per cent in patients with complicated ventricular arrhythmias and 31 per cent in patients with an ejection fraction less than 0.40. All eight patients who died suddenly were in the subgroup of 26 patients with an ejection fraction less than 0.40 and complicated ventricular arrhymias; none was in the subgroup of 19 patients with an ejection fraction less than 0.40 and uncomplicated ventricular arrhythmias (P less than 0.02). Although a low ejection fraction may suggest a poor prognosis following myocardial infarction, the presence of complicated ventricular arrhythmias significantly increases the risk of sudden cardiac death in the early period after hospitalization in patients with low ejection fraction.
Asunto(s)
Muerte Súbita , Corazón/fisiopatología , Infarto del Miocardio/mortalidad , Arritmias Cardíacas/fisiopatología , Electrocardiografía , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Factores de TiempoRESUMEN
Recent studies have suggested a similar prognosis for patients with transmural myocardial infarction and nontransmural myocardial infarction despite a smaller infarct size in the latter patients estimated by creatine phosphokinase (CPK). Thirty-one patients with transmural myocardial infarction and 17 patients with nontransmural myocardial infarction as defined by electrocardiographic criteria underwent coronary angiography and left ventriculography from 10 to 24 days after they had an acute myocardial infarction. Forty-three of these 48 patients were asymptomatic following their myocardial infarction. When compared to patients with nontransmural myocardial infarction, those with transmural myocardial infarction had greater peak CPK levels, 1,090 +/- 210 versus 290 +/- 60 IU (p less than 0.01). There was no difference in prevalence of single, double or triple vessel coronary artery disease, mean number of coronary arteries 50 per cent narrowed (2.0 +/- 0.2 versus 2.0 +/- 0.2), near total or total occlusions, coronary score (Friesinger) (7.9 +/- 0.6 versus 8.2 +/- 0.7), left ventricular ejection fraction (48 +/- 2 versus 53 +/- 4), or per cent of akinetic-dyskinetic myocardial segments (66 of 242 [27 per cent] versus 32 of 132 [24 per cent]) between two groups. The similar extent of coronary artery narrowing and degree of left ventricular dysfunction may explain the similar prognosis for patients with transmural myocardial infarction and those with nontransmural myocardial infarction despite differences in enzymatically estimated acute infarct size.