Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 18(1): 206, 2017 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-28532493

RESUMEN

BACKGROUND: The aim of this study was to compare the functional outcomes and complication rates after distal femoral replacement (DFR) performed with the modular Munich-Luebeck (MML) modular prosthesis (ESKA/Orthodynamics, Luebeck, Germany) in patients being treated for malignant disease or failed total knee arthroplasty. METHODS: A retrospective review of patient charts and a functional investigation (involving Musculoskeletal Tumor Society Score [MSTS], American Knee Society Score [AKSS], Oxford Knee Score [OKS], Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC], Toronto Extremity Salvage Score [TESS], the 12-Item Short-Form [SF-12] Health Survey, and a failure classification system developed by Henderson et al.) of DFR cases from 2002 to 2015 were conducted. The indications for DFR were malignant tumor resection in the femur (n = 20, group A) or failure of revision total knee arthroplasty without a history of malignant disease (n = 16, group B). RESULTS: One-hundred and twenty-nine patients were treated during the study period. Of these, 82 were analyzed for complications and implant-survival. Further, 36 patients were available for functional assessment after a mean follow-up of 86 months (range: 24-154). There were 75 complications in total. The overall failure rate for DFR was 64.6% (53/82 patients). The most common failure mechanisms were type III (mechanical failure), followed by type I (soft tissue) and type II (aseptic loosening). The mean MSTS score (out of 30) was 17 for group A and 12 for group B. All the clinical outcome scores revealed an age-dependent deterioration of function. CONCLUSION: DFR is an established procedure to restore distal femoral integrity. However, complication rates are high. Post-procedure functionality depends mainly on the patient's age at initial reconstruction.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/tendencias , Neoplasias Femorales/cirugía , Prótesis de Cadera/tendencias , Falla de Prótesis/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Neoplasias Femorales/diagnóstico , Neoplasias Femorales/epidemiología , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis/métodos , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA