Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Neuroimage ; 277: 120219, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37307867

RESUMEN

Electrophysiological source imaging (ESI) aims at reconstructing the precise origin of brain activity from measurements of the electric field on the scalp. Across laboratories/research centers/hospitals, ESI is performed with different methods, partly due to the ill-posedness of the underlying mathematical problem. However, it is difficult to find systematic comparisons involving a wide variety of methods. Further, existing comparisons rarely take into account the variability of the results with respect to the input parameters. Finally, comparisons are typically performed using either synthetic data, or in-vivo data where the ground-truth is only roughly known. We use an in-vivo high-density EEG dataset recorded during intracranial single pulse electrical stimulation, in which the true sources are substantially dipolar and their locations are precisely known. We compare ten different ESI methods, using their implementation in the MNE-Python package: MNE, dSPM, LORETA, sLORETA, eLORETA, LCMV beamformers, irMxNE, Gamma Map, SESAME and dipole fitting. We perform comparisons under multiple choices of input parameters, to assess the accuracy of the best reconstruction, as well as the impact of such parameters on the localization performance. Best reconstructions often fall within 1 cm from the true source, with most accurate methods hitting an average localization error of 1.2 cm and outperforming least accurate ones erring by 2.5 cm. As expected, dipolar and sparsity-promoting methods tend to outperform distributed methods. For several distributed methods, the best regularization parameter turned out to be the one in principle associated with low SNR, despite the high SNR of the available dataset. Depth weighting played no role for two out of the six methods implementing it. Sensitivity to input parameters varied widely between methods. While one would expect high variability being associated with low localization error at the best solution, this is not always the case, with some methods producing highly variable results and high localization error, and other methods producing stable results with low localization error. In particular, recent dipolar and sparsity-promoting methods provide significantly better results than older distributed methods. As we repeated the tests with "conventional" (32 channels) and dense (64, 128, 256 channels) EEG recordings, we observed little impact of the number of channels on localization accuracy; however, for distributed methods denser montages provide smaller spatial dispersion. Overall findings confirm that EEG is a reliable technique for localization of point sources and therefore reinforce the importance that ESI may have in the clinical context, especially when applied to identify the surgical target in potential candidates for epilepsy surgery.


Asunto(s)
Electroencefalografía , Epilepsia , Humanos , Electroencefalografía/métodos , Mapeo Encefálico/métodos , Fenómenos Electrofisiológicos , Procesamiento de Señales Asistido por Computador
2.
Astrophys J ; 862(1)2018 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-30510305

RESUMEN

The hard X-ray emission in a solar flare is typically characterized by a number of discrete sources, each with its own spectral, temporal, and spatial variability. Establishing the relationship among these sources is critical to determining the role of each in the energy release and transport processes that occur within the flare. In this paper we present a novel method to identify and characterize each source of hard X-ray emission. The method permits a quantitative determination of the most likely number of subsources present, and of the relative probabilities that the hard X-ray emission in a given subregion of the flare is represented by a complicated multiple source structure or by a simpler single source. We apply the method to a well-studied flare on 2002 February 20 in order to assess competing claims as to the number of chromospheric footpoint sources present, and hence to the complexity of the underlying magnetic geometry/topology. Contrary to previous claims of the need for multiple sources to account for the chromospheric hard X-ray emission at different locations and times, we find that a simple two-footpoint-plus-coronal-source model is the most probable explanation for the data. We also find that one of the footpoint sources moves quite rapidly throughout the event, a factor that presumably complicated previous analyses. The inferred velocity of the footpoint corresponds to a very high induced electric field, compatible with the fields in thin reconnecting current sheets.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA