1.
J Magn Reson Imaging ; 59(2): 661-672, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37259965

RESUMEN

BACKGROUND: Sensitive detection and quantification of cerebral glucose is desired. PURPOSE: To quantify cerebral glucose by detecting the H1-α-glucose peak at 5.23 ppm in 1 H magnetic resonance spectroscopy at 7 T. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight non-fasted healthy subjects (aged 20-28 years). FIELD STRENGTH/SEQUENCE: Short echo time stimulated echo acquisition mode (short-TE STEAM) and semi-localized by adiabatic selective refocusing (semi-LASER) at 7 T. ASSESSMENT: Single voxel spectra were obtained from the posterior cingulate cortex (27-mL) using a 32-channel head coil. The H1-α-glucose peak in the spectrum with retrospective removal of the residual water peak was fitted using LCModel with a glucose basis set of only the H1-α-glucose peak. Conventional spectral analysis was performed with a glucose basis set of a full spectral pattern of glucose, also. Fitting precision was evaluated with Cramér-Rao lower bounds (CRLBs). The repeatability of glucose quantification via the semi-LASER sequence was tested. STATISTICAL TESTS: Paired or Welch's t-test were used for normally distributed values. A P value of <0.05 was considered significant. The repeatability of measures was analyzed using coefficient of variation (CV). RESULTS: Removal of the residual water peak improved the flatness and stability of baselines around the H1-α-glucose peak and reduced CRLBs for fitting the H1-α-glucose peak. The semi-LASER sequence was superior to the short-TE STEAM in the higher signal-to-noise ratio of the H1-α-glucose peak (mean ± SD 7.9 ± 2.5, P < 0.001). The conventional analysis overfitted the H1-α-glucose peak. The individual CVs of glucose quantification by detecting the H1-α-glucose peak were smaller than the corresponding CRLBs. DATA CONCLUSION: Cerebral glucose concentration is quantitated to be 1.07 mM by detecting the H1-α-glucose peak in the semi-LASER spectra. Despite requiring long scan times, detecting the H1-α-glucose peak allows true glucose quantification free from the influence of overlapping taurine and macromolecule signals. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Encéfalo , Agua , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Espectroscopía de Resonancia Magnética/métodos , Relación Señal-Ruido , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo
2.
Magn Reson Med ; 89(5): 2048-2061, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36576212

RESUMEN

PURPOSE: The purpose of this study is to assess the intra- and interscan repeatability of free-breathing phase-resolved functional lung (PREFUL) MRI in stable pediatric cystic fibrosis (CF) lung disease in comparison to static breath-hold hyperpolarized 129-xenon MRI (Xe-MRI) and pulmonary function tests. METHODS: Free-breathing 1-hydrogen MRI and Xe-MRI were acquired from 15 stable pediatric CF patients and seven healthy age-matched participants on two visits, 1 month apart. Same-visit MRI scans were also performed on a subgroup of the CF patients. Following the PREFUL algorithm, regional ventilation (RVent) and regional flow volume loop cross-correlation maps were determined from the free-breathing data. Ventilation defect percentage (VDP) was determined from RVent maps (VDPRVent ), regional flow volume loop cross-correlation maps (VDPCC ), VDPRVent ∪ VDPCC , and multi-slice Xe-MRI. Repeatability was evaluated using Bland-Altman analysis, coefficient of repeatability (CR), and intraclass correlation. RESULTS: Minimal bias and no significant differences were reported for all PREFUL MRI and Xe-MRI VDP parameters between intra- and intervisits (all P > 0.05). Repeatability of VDPRVent , VDPCC , VDPRVent ∪ VDPCC , and multi-slice Xe-MRI were lower between the two-visit scans (CR = 14.81%, 15.36%, 16.19%, and 9.32%, respectively) in comparison to the same-day scans (CR = 3.38%, 2.90%, 1.90%, and 3.92%, respectively). pulmonary function tests showed high interscan repeatability relative to PREFUL MRI and Xe-MRI. CONCLUSION: PREFUL MRI, similar to Xe-MRI, showed high intravisit repeatability but moderate intervisit repeatability in CF, which may be due to inherent disease instability, even in stable patients. Thus, PREFUL MRI may be considered a suitable outcome measure for future treatment response studies.


Asunto(s)
Fibrosis Quística , Humanos , Niño , Fibrosis Quística/diagnóstico por imagen , Respiración , Pulmón/diagnóstico por imagen , Pruebas de Función Respiratoria , Isótopos de Xenón , Imagen por Resonancia Magnética , Xenón
3.
Eur Radiol ; 33(4): 2536-2547, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36460925

RESUMEN

OBJECTIVE: To compare standard (STD-DWI) single-shot echo-planar imaging DWI and simultaneous multislice (SMS) DWI during whole-body positron emission tomography (PET)/MRI regarding acquisition time, image quality, and lesion detection. METHODS: Eighty-three adults (47 females, 57%), median age of 64 years (IQR 52-71), were prospectively enrolled from August 2018 to March 2020. Inclusion criteria were (a) abdominal or pelvic tumors and (b) PET/MRI referral from a clinician. Patients were excluded if whole-body acquisition of STD-DWI and SMS-DWI sequences was not completed. The evaluated sequences were axial STD-DWI at b-values 50-400-800 s/mm2 and the apparent diffusion coefficient (ADC), and axial SMS-DWI at b-values 50-300-800 s/mm2 and ADC, acquired with a 3-T PET/MRI scanner. Three radiologists rated each sequence's quality on a five-point scale. Lesion detection was quantified using the anatomic MRI sequences and PET as the reference standard. Regression models were constructed to quantify the association between all imaging outcomes/scores and sequence type. RESULTS: The median whole-body STD-DWI acquisition time was 14.8 min (IQR 14.1-16.0) versus 7.0 min (IQR 6.7-7.2) for whole-body SMS-DWI, p < 0.001. SMS-DWI image quality scores were higher than STD-DWI in the abdomen (OR 5.31, 95% CI 2.76-10.22, p < 0.001), but lower in the cervicothoracic junction (OR 0.21, 95% CI 0.10-0.43, p < 0.001). There was no significant difference in the chest, mediastinum, pelvis, and rectum. STD-DWI detected 276/352 (78%) lesions while SMS-DWI located 296/352 (84%, OR 1.46, 95% CI 1.02-2.07, p = 0.038). CONCLUSIONS: In cancer staging and restaging, SMS-DWI abbreviates acquisition while maintaining or improving the diagnostic yield in most anatomic regions. KEY POINTS: • Simultaneous multislice diffusion-weighted imaging enables faster whole-body image acquisition. • Simultaneous multislice diffusion-weighted imaging maintains or improves image quality when compared to single-shot echo-planar diffusion-weighted imaging in most anatomical regions. • Simultaneous multislice diffusion-weighted imaging leads to superior lesion detection.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Tomografía de Emisión de Positrones , Imagen de Cuerpo Entero , Anciano , Femenino , Humanos , Persona de Mediana Edad , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , Masculino , Imagen de Cuerpo Entero/métodos
4.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35713379

RESUMEN

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Asunto(s)
Imagen por Resonancia Magnética , Próstata , Brasil , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
5.
J Magn Reson Imaging ; 55(6): 1696-1707, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35312203

RESUMEN

BACKGROUND: Evaluation of structural lung abnormalities with magnetic resonance imaging (MRI) has previously been shown to be predictive of clinical neonatal outcomes in preterm birth. MRI during free-breathing with phase-resolved functional lung (PREFUL) may allow for complimentary functional information without exogenous contrast. PURPOSE: To investigate the feasibility of structural and functional pulmonary MRI in a cohort of neonates and infants with no cardiorespiratory disease. Macrovascular pulmonary blood flows were also evaluated. STUDY TYPE: Prospective. POPULATION: Ten term infants with no clinically defined cardiorespiratory disease were imaged. Infants recruited from the general population and neonatal intensive care unit (NICU) were studied. FIELD STRENGTH/SEQUENCE: T1 -weighted VIBE, T2 -weighted BLADE uncorrected for motion. Ultrashort echo time (UTE) and 3D-flow data were acquired during free-breathing with self-navigation and retrospective reconstruction. Single slice 2D-gradient echo (GRE) images were acquired during free-breathing for PREFUL analysis. Imaging was performed at 3 T. ASSESSMENT: T1 , T2 , and UTE images were scored according to the modified Ochiai scheme by three pediatric body radiologists. Ventilation/perfusion-weighted maps were extracted from free-breathing GRE images using PREFUL analysis. Ventilation and perfusion defect percent (VDP, QDP) were calculated from the segmented ventilation and perfusion-weighted maps. Time-averaged cardiac blood velocities from three-dimensional-flow were evaluated in major pulmonary arteries and veins. STATISTICAL TEST: Intraclass correlation coefficient (ICC). RESULTS: The ICC of replicate structural scores was 0.81 (95% CI: 0.45-0.95) across three observers. Elevated Ochiai scores, VDP, and QDP were observed in two NICU participants. Excluding these participants, mean ± standard deviation structural scores were 1.2 ± 0.8, while VDP and QDP were 1.0% ± 1.1% and 0.4% ± 0.5%, respectively. Main pulmonary arterial blood flows normalized to body surface area were 3.15 ± 0.78 L/min/m2 . DATA CONCLUSION: Structural and functional pulmonary imaging is feasible using standard clinical MRI hardware (commercial whole-body 3 T scanner, table spine array, and flexible thoracic array) in free-breathing infants. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Nacimiento Prematuro , Niño , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Recién Nacido , Pulmón , Imagen por Resonancia Magnética , Embarazo , Estudios Prospectivos , Estudios Retrospectivos
6.
IEEE ASME Trans Mechatron ; 27(1): 407-417, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35185321

RESUMEN

Brachytherapy is a radiation based treatment that is implemented by precisely placing focused radiation sources into tumors. In advanced interstitial cervical cancer bracytherapy treatment, this is performed by placing a metallic rod ("stylet") inside a hollow cylindrical tube ("catheter") and advancing the pair to the desired target. The stylet is removed once the target is reached, followed by the insertion of radiation sources into the catheter. However, manually advancing an initially straight stylet into the tumor with millimeter spatial accuracy has been a long-standing challenge, which requires multiple insertions and retractions, due to the unforeseen stylet deflection caused by the stiff muscle tissue that is traversed. In this paper, we develop a novel tendon-actuated deflectable stylet equipped with MR active-tracking coils that may enhance brachytherapy treatment outcomes by allowing accurate stylet trajectory control. Herein we present the design concept and fabrication method, followed by the kinematic and mechanics models of the deflectable stylet. The hardware and theoretical models are extensively validated via benchtop and MRI-guided characterization. At insertion depths of 60 mm, benchtop phantom targeting tests provided a targeting error of 1. 23 ± 0. 47 mm, and porcine tissue targeting tests provided a targeting error of 1. 65 ± 0. 64 mm, after only a single insertion. MR-guided experiments indicate that the stylet can be safely and accurately located within the MRI environment.

7.
AJR Am J Roentgenol ; 215(1): 94-104, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32348181

RESUMEN

OBJECTIVE. The purpose of this study was to develop a motion insensitive clinical dynamic contrast-enhanced MRI (DCE-MRI) protocol to assess the response of pleural tumors in clinical trials. MATERIALS AND METHODS. Thirty-two patients with pleura-based lesions were administered contrast material and imaged with gradient-recalled echo DCE-MRI sequence variants: either a traditional cartesian k-space acquisition (FLASH), a time-resolved imaging with stochastic trajectories acquisition (TWIST), or a radial stack-of-stars acquisition (radial) sequence in addition to other standard-of-care imaging sequences. Each image acquisition's sensitivity to motion was evaluated by comparing the motion of the thoracic border in 3D throughout the acquisition. One-way ANOVA was used to compare the image quality between different acquisitions. The 95% CIs were calculated for mean thoracic border displacement. The effects of motion on kinetic parameter estimation were explored with simulations according to clinically acquired data. RESULTS. Radial was the most motion-robust sequence with subvoxel mean displacement in the superior-inferior direction (0.4 ± 1.2 [SD] mm). FLASH showed intermediate displacement (4.6 ± 2.0 mm), whereas TWIST was most sensitive to motion (6.4 ± 3.4 mm). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images acquired with the radial sequence were on par or better than the FLASH and TWIST sequences when reconstructed with an improved density compensation algorithm. Simulations showed that motion on scans showing pleural-based lesions can lead to markedly inaccurate kinetic parameter estimation and inappropriate kinetic model convergence within a nested model analysis. CONCLUSION. A practical radial k-space trajectory sequence that provides motion-insensitive pharmacokinetic parameters was incorporated as part of the DCE-MRI protocol of pleural tumors. Validation and usefulness in clinical trials assessing response to therapy is needed.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias Pleurales/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Respiración , Sensibilidad y Especificidad , Relación Señal-Ruido
9.
NMR Biomed ; 29(7): 999-1009, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27241215

RESUMEN

A biomarker of cancer aggressiveness, such as hypoxia, could substantially impact treatment decisions in the prostate, especially radiation therapy, by balancing treatment morbidity (urinary incontinence, erectile dysfunction, etc.) against mortality. R2 (*) mapping with Mono-Exponential (ME) decay modeling has shown potential for identifying areas of prostate cancer hypoxia at 1.5T. However, Gaussian deviations from ME decay have been observed in other tissues at 3T. The purpose of this study is to assess whether gradient-echo signal decays are better characterized by a standard ME decay model, or a Gaussian Augmentation of the Mono-Exponential (GAME) decay model, in the prostate at 3T. Multi-gradient-echo signals were acquired on 20 consecutive patients with a clinical suspicion of prostate cancer undergoing MR-guided prostate biopsies. Data were fitted with both ME and GAME models. The information contents of these models were compared using Akaike's information criterion (second order, AICC ), in skeletal muscle, the prostate central gland (CG), and peripheral zone (PZ) regions of interest (ROIs). The GAME model had higher information content in 30% of the prostate on average (across all patients and ROIs), covering up to 67% of cancerous PZ ROIs, and up to 100% of cancerous CG ROIs (in individual patients). The higher information content of GAME became more prominent in regions that would be assumed hypoxic using ME alone, reaching 50% of the PZ and 70% of the CG as ME R2 (*) approached 40 s(-1) . R2 (*) mapping may have important applications in MRI; however, information lost due to modeling could mask differences in parameters due to underlying tissue anatomy or physiology. The GAME model improves characterization of signal behavior in the prostate at 3T, and may increase the potential for determining correlates of fit parameters with biomarkers, for example of oxygenation status.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Modelos Estadísticos , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Algoritmos , Simulación por Computador , Interpretación Estadística de Datos , Humanos , Masculino , Distribución Normal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
10.
J Magn Reson Imaging ; 44(4): 1020-30, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26971387

RESUMEN

PURPOSE: To assess whether R2* mapping with a standard Monoexponential (ME) or a Gaussian Augmentation of the Monoexponential (GAME) decay model better characterizes gradient-echo signal decays in gynecological cancers after external beam radiation therapy at 3T, and evaluate implications of modeling for noninvasive identification of intratumoral hypoxia. MATERIALS AND METHODS: Multi-gradient-echo signals were acquired on 25 consecutive patients with gynecologic cancers and three healthy participants during inhalation of different oxygen concentrations at 3T. Data were fitted with both ME and GAME models. Models were compared using F-tests in tumors and muscles in patients, muscles, cervix, and uterus in healthy participants, and across oxygenation levels. RESULTS: GAME significantly improved fitting over ME (P < 0.05): Improvements with GAME covered 34% of tumor regions-of-interest on average, ranging from 6% (of a vaginal tumor) to 68% (of a cervical tumor) in individual tumors. Improvements with GAME were more prominent in areas that would be assumed hypoxic based on ME alone, reaching 90% as ME R2* approached 100 Hz. Gradient echo decay parameters at different oxygenation levels were not significantly different (P = 0.81). CONCLUSION: R2* may prove sensitive to hypoxia; however, inaccurate representations of underlying data may limit the success of quantitative assessments. Although the degree to which R2 or σ values correlate with hypoxia remains unknown, improved characterization with GAME increases the potential for determining any correlates of fit parameters with biomarkers, such as oxygenation status. J. MAGN. RESON. IMAGING 2016;44:1020-1030.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/metabolismo , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Oxígeno/metabolismo , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Distribución Normal , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Hipoxia Tumoral
11.
Magn Reson Med ; 73(5): 1803-11, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24903165

RESUMEN

PURPOSE: To develop an active MR-tracking system to guide placement of metallic devices for radiation therapy. METHODS: An actively tracked metallic stylet for brachytherapy was constructed by adding printed-circuit micro-coils to a commercial stylet. The coil design was optimized by electromagnetic simulation, and has a radio-frequency lobe pattern extending ∼5 mm beyond the strong B0 inhomogeneity region near the metal surface. An MR-tracking sequence with phase-field dithering was used to overcome residual effects of B0 and B1 inhomogeneities caused by the metal, as well as from inductive coupling to surrounding metallic stylets. The tracking system was integrated with a graphical workstation for real-time visualization. The 3 Tesla MRI catheter-insertion procedures were tested in phantoms and ex vivo animal tissue, and then performed in three patients during interstitial brachytherapy. RESULTS: The tracking system provided high-resolution (0.6 × 0.6 × 0.6 mm(3) ) and rapid (16 to 40 frames per second, with three to one phase-field dithering directions) catheter localization in phantoms, animals, and three gynecologic cancer patients. CONCLUSION: This is the first demonstration of active tracking of the shaft of metallic stylet in MR-guided brachytherapy. It holds the promise of assisting physicians to achieve better targeting and improving outcomes in interstitial brachytherapy.


Asunto(s)
Artefactos , Braquiterapia/instrumentación , Braquiterapia/métodos , Marcadores Fiduciales , Neoplasias de los Genitales Femeninos/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Metales , Radioterapia Asistida por Computador/instrumentación , Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/instrumentación , Radioterapia Guiada por Imagen/métodos , Animales , Pollos , Gráficos por Computador , Simulación por Computador , Campos Electromagnéticos , Diseño de Equipo , Femenino , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Fantasmas de Imagen , Programas Informáticos
12.
Radiographics ; 35(5): 1439-60, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26207581

RESUMEN

Body magnetic resonance (MR) imaging is challenging because of the complex interaction of multiple factors, including motion arising from respiration and bowel peristalsis, susceptibility effects secondary to bowel gas, and the need to cover a large field of view. The combination of these factors makes body MR imaging more prone to artifacts, compared with imaging of other anatomic regions. Understanding the basic MR physics underlying artifacts is crucial to recognizing the trade-offs involved in mitigating artifacts and improving image quality. Artifacts can be classified into three main groups: (a) artifacts related to magnetic field imperfections, including the static magnetic field, the radiofrequency (RF) field, and gradient fields; (b) artifacts related to motion; and (c) artifacts arising from methods used to sample the MR signal. Static magnetic field homogeneity is essential for many MR techniques, such as fat saturation and balanced steady-state free precession. Susceptibility effects become more pronounced at higher field strengths and can be ameliorated by using spin-echo sequences when possible, increasing the receiver bandwidth, and aligning the phase-encoding gradient with the strongest susceptibility gradients, among other strategies. Nonuniformities in the RF transmit field, including dielectric effects, can be minimized by applying dielectric pads or imaging at lower field strength. Motion artifacts can be overcome through respiratory synchronization, alternative k-space sampling schemes, and parallel imaging. Aliasing and truncation artifacts derive from limitations in digital sampling of the MR signal and can be rectified by adjusting the sampling parameters. Understanding the causes of artifacts and their possible solutions will enable practitioners of body MR imaging to meet the challenges of novel pulse sequence design, parallel imaging, and increasing field strength.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Tejido Adiposo/patología , Conversión Analogo-Digital , Imagen Eco-Planar/instrumentación , Imagen Eco-Planar/métodos , Diseño de Equipo , Falla de Equipo , Humanos , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Magnetismo , Movimiento (Física) , Sensibilidad y Especificidad , Vísceras/patología
14.
J Neurooncol ; 119(1): 111-9, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24792644

RESUMEN

Spin-echo echo planar (EP) perfusion weighted imaging (SE-PWI) has been demonstrated to be more selective than gradient-echo EP PWI for blood volume in microvessels the size of glioma neocapillaries, but it has not been comprehensively studied in human clinical use. We assessed whether SE-PWI before and after initiating chemoradiation can stratify patients with respect to progression free survival (PFS) and overall survival (OS). Sixty-eight patients with newly diagnosed glioblastoma (mean age 58.3, 36 males) were included in analysis. SE EP cerebral blood volumes (SE-CBVs) in enhancing and nonenhancing tumor, normalized to contralateral normal appearing white matter (SE-nCBV), were assessed at baseline and after initial chemoradiation. SE-nCBV parameters predictive of PFS and OS were identified in univariate and multivariate Cox proportional hazards models. Multivariate analysis demonstrated that baseline tumor mean SE-nCBV was predictive of PFS (p = 0.038) and OS (p = 0.004). Within the patient sample, baseline tumor mean SE-nCBV <2.0 predicted longer patient PFS (median 47.0 weeks, p < 0.001) and OS (median 98.6 weeks, p = 0.003) compared with baseline mean SE-nCBV >2.0 (median PFS 25.3, median OS 56.0 weeks). Exploratory multi-group stratification demonstrated that very high (>4.0) tumor SE-nCBV was associated with worse patient OS than intermediate high (>2.0, <4.0) SE-nCBV (p = 0.025). Baseline mean SE-nCBV can stratify patients for PFS and OS prior to initiation of chemoradiation, which may help select patients who require closer surveillance. Our exploratory analysis indicates a magnitude-dependent relationship between baseline SE-nCBV and OS.


Asunto(s)
Neoplasias Encefálicas/patología , Glioblastoma/patología , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/terapia , Quimioradioterapia , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Imagen Eco-Planar , Femenino , Glioblastoma/mortalidad , Glioblastoma/terapia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Tasa de Supervivencia , Resultado del Tratamiento
15.
Eur J Radiol ; 176: 111527, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38810438

RESUMEN

PURPOSE: To assess the potential of apparent diffusion coefficient (ADC) values derived from diffusion weighted (DW) MRI preoperatively to predict the predominant histologic component among biphasic pleural mesothelioma (PM) tumors. METHODS: ADC maps were generated from DW MRI scans. Histology and predominant component of biphasic PM were confirmed following surgical resection. Statistical analyses were done with R (R Foundation for Statistical Computing, Vienna, Austria). Average ADC values corresponding to epithelioid- and sarcomatoid-predominant tumors were compared. ADC thresholding was accomplished by recursive partitioning and confirmed with ROC analysis. RESULTS: Eighty-four patients with biphasic PM's, 69 (82 %) epithelioid-predominant (BE) and 15(18 %) sarcomatoid-predominant (BS) tumors were evaluated. Thirty-eight (45 %) patients underwent extrapleural pneumonectomy (EPP), 39 (46 %) had extended pleural decortication (ePDC) and 7 (8 %) had pleural decortication (PDC). ADC values ranged between 0.696 x 10-3 to 1.921 x 10-3 mm2/s. BE tumors demonstrated significantly higher ADC values than BS tumors (p = 0.026). ADC values above 0.94 x 10-3 mm2/s were associated with a significant increase of relative risk of being in group BE over group BS (relative risk: 1.47, 95 %CI: 1.05-2.06, p = 0.027) CONCLUSION: Average ADC values of BE tumors were higher than BS tumors and the two groups can be separated by a cut off value of 0.94 X 10-3 mm2/s.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Mesotelioma , Neoplasias Pleurales , Humanos , Neoplasias Pleurales/diagnóstico por imagen , Neoplasias Pleurales/patología , Neoplasias Pleurales/cirugía , Masculino , Femenino , Persona de Mediana Edad , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Mesotelioma/diagnóstico por imagen , Mesotelioma/patología , Mesotelioma/cirugía , Adulto , Diagnóstico Diferencial , Anciano de 80 o más Años , Sensibilidad y Especificidad , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Mesotelioma Maligno/diagnóstico por imagen , Mesotelioma Maligno/patología
17.
AJR Am J Roentgenol ; 201(1): 117-21, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23789664

RESUMEN

OBJECTIVE: Ultrasmall superparamagnetic iron oxide nanoparticles, such as ferumoxytol, produce decreased MR signal on susceptibility-inducing T2*-weighted sequences in tissues of the reticuloendothelial system. However, acute iron deposition in the adrenals has not been reported. The purpose of this article is to report our initial observations of the imaging behavior of the normal adrenals on ferumoxytol-enhanced T2*-weighted magnetic resonance imaging. SUBJECTS AND METHODS: Quantitative T2* imaging was performed at 3 T using a breath-hold monopolar multiecho gradient echo sequence with six equally spaced in-phase echoes in nine patients. Changes in signal-to-noise ratio (SNR) were analyzed prior to and 48 hours after ferumoxytol administration in the adrenals, liver and spleen (positive controls), and pancreas and skeletal muscle (negative controls). RESULTS: In comparison with unenhanced images, there was an average SNR decrease of 67.4% in the right adrenal, 77.6% in the left adrenal, 68.4% in the liver, 89.1% in the spleen, 15.0% in the pancreas, and 9.5% in skeletal muscle on T2*-weighted images obtained 48 hours after ferumoxytol administration. The decrease in SNR observed in the adrenals was significantly greater than that seen in the pancreas and skeletal muscle (left adrenal, p < 0.0001; right adrenal, p = 0.0002) and similar to that seen in the liver and spleen. CONCLUSION: The normal adrenal loses signal on ferumoxytol-enhanced T2*-weighted MRI. Acute iron deposition within the adrenals has not been previously described. The mechanism of ferumoxytol uptake in the adrenal and potential clinical applications warrant further investigation.


Asunto(s)
Adenocarcinoma/patología , Glándulas Suprarrenales/metabolismo , Medios de Contraste/farmacocinética , Óxido Ferrosoférrico/farmacocinética , Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Relación Señal-Ruido
18.
Heliyon ; 9(7): e18357, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37539101

RESUMEN

Rationale and objectives: Macromolecules (MMs) affect the precision and accuracy of neurochemical quantification in magnetic resonance spectroscopy. A measured MM basis is increasingly used in LCModel analysis combined with a spline baseline, whose stiffness is controlled by a parameter named DKNTMN. The effects of measured MM basis and DKNTMN were investigated. Materials and methods: Twenty-six healthy subjects were prospectively enrolled and scanned twice using a short echo-time Stimulated Echo Acquisition Mode (STEAM) at 7-T. Using LCModel, analyses were conducted using the simulated MM basis (MMsim) with DKNTMN 0.15 and an MM basis measured inhouse (MMmeas) with DKNTMN of 0.15, 0.30, 0.60 and 1.00. Cramér-Rao lower bound (CRLB) and the concentrations of gamma-aminobutyric acid (GABA), glutamate and excitatory-inhibitory ratio (EIR), in addition to MMs were statistically analyzed. Measurement stability was evaluated using coefficient of variation (CV). Results: CRLBs of GABA were significantly lower when using MMsim than MMmeas; those of glutamate were 2-3. GABA concentrations were significantly higher in the analysis using MMsim than MMmeas where concentrations were significantly higher with DKNTMN of 0.15 or 0.30 than 0.60 or 1.00. Difference in glutamate concentration was not significant. EIRs showed the same difference as in GABA depending on the DKNTMN values. CVs between test-retest scans were relatively stable for glutamate but became larger as DKNTMN increased for GABA and EIR. Conclusion: Neurochemical quantification depends on the parameters of the basis sets used for fitting. Analysis using MMmeas with DKNTMN of 0.30 conformed best to previous studies and is recommended.

19.
J Neuroimaging ; 32(3): 377-388, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35099832

RESUMEN

Ultra-high-field 7.0 Tesla (T) MRI offers substantial gains in signal-to-noise ratio (SNR) over 3T and 1.5T, but for over two decades has remained a research tool, while 3T scanners have achieved widespread clinical use. This much slower translation of 7T relates to daunting technical challenges encountered in ultra-high-field human MR imaging. The recent introduction of United States Food and Drug Administration (FDA)-approved clinical 7T scanners promises to be a watershed for many 7T neuroimaging applications, including epilepsy imaging. The high SNR of 7T allows clinical imaging of fine neuroanatomic detail at unprecedented spatial resolution, helping with detection and differentiation of subtle, potentially treatable lesions undetectable or suboptimally assessed at 3T. The accompanying research paper reports our group's analysis of 7T MRI efficacy in epilepsy treatment planning. Here, we introduce the technical background and clinical approach we currently use, in order to assist clinical epileptologists and neuroimagers contemplating, creating, or referring patients to a clinical 7T epilepsy imaging service. We describe a tiered epilepsy imaging strategy and protocols designed to optimize 7T value and work around signal intensity variation and signal loss artifacts, which remain significant challenges to full exploitation of 7T clinical value. We describe FDA-approved techniques for mitigating these artifacts and briefly outline techniques currently under development, but not yet FDA approved. Finally, we discuss the major issues in 7T patient safety and toleration, outlining their physical causes and effects on workflow, and provide references to more comprehensive technical reviews for readers seeking greater technical detail.


Asunto(s)
Epilepsia , Imagen por Resonancia Magnética , Epilepsia/diagnóstico por imagen , Epilepsia/terapia , Humanos , Imagen por Resonancia Magnética/métodos , Neuroimagen , Selección de Paciente , Relación Señal-Ruido
20.
Acad Radiol ; 28(8): e209-e218, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32532639

RESUMEN

RATIONALE AND OBJECTIVES: Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a free-breathing 1H-based technique that produces maps of fractional ventilation (FV). This study compared ventilation defect percent (VDP) calculated using PREFUL to hyperpolarized (HP) 129Xe MRI and pulmonary function tests in pediatric cystic fibrosis (CF). MATERIALS AND METHODS: 27 pediatric participants were recruited (mean age 13.0 ± 2.7), including 6 with clinically stable CF, 11 CF patients undergoing a pulmonary exacerbation (PEx), and 10 healthy controls. Spirometry was performed to measure forced expiratory volume in 1 second (FEV1), along with nitrogen multiple breath washout to measure lung clearance index (LCI). VDP was calculated from single central coronal slice PREFUL FV maps and the corresponding HP 129Xe slice. RESULTS: The stable CF group had a normal FEV1 (p = 0.41) and elevated LCI (p = 0.007). The CF PEx group had a decreased FEV1 (p < 0.0001) and elevated LCI (p < 0.0001). PREFUL and HP 129Xe VDP were significantly different between the CF PEx and healthy groups (p < 0.05). In the stable CF group, PREFUL and HP 129Xe VDP were not significantly different from the healthy group (p = 0.18 and 0.08, respectively). There was a correlation between PREFUL and HP 129Xe VDP (R2 = 0.31, p = 0.004), and both parameters were significantly correlated with FEV1 and LCI. CONCLUSION: PREFUL MRI is feasible in pediatric CF, distinguishes patients undergoing pulmonary exacerbations compared to healthy subjects, and correlates with HP 129Xe MRI as well as functional measures of disease severity. PREFUL MRI does not require breath-holds and is straight forward to implement on any MRI scanner.


Asunto(s)
Fibrosis Quística , Adolescente , Niño , Fibrosis Quística/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Pruebas de Función Respiratoria , Isótopos de Xenón