Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 34(11): 1963-1969, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37532095

RESUMEN

PURPOSE: To assess the diagnostic performance of carbon dioxide (CO2) and intraprocedural unenhanced computed tomography (CT) for adrenal venous sampling (AVS) (CO2-intraprocedural unenhanced CT-AVS) in patients with primary aldosteronism (PA) and a history of iodine contrast medium allergy. MATERIALS AND METHODS: CO2-intraprocedural unenhanced CT-AVS was performed in 18 patients with iodine contrast media allergies at the authors' hospital between December 2015 and January 2021. CT and noncontrast magnetic resonance angiography were used to evaluate the preoperative adrenal vein anatomy. CO2 venography was performed to confirm adrenal vein catheterization. Additionally, intraprocedural unenhanced CT was also performed to confirm catheter position in the right adrenal gland. RESULTS: In all cases in which CO2-intraprocedural unenhanced CT-AVS was performed, the right and left adrenal veins were catheterized appropriately, leading to a localized diagnosis. Catheterization of the left adrenal vein was confirmed using CO2 venography in all cases. In 7 of the 18 cases, CO2 venography demonstrated selection of the right adrenal vein. In 15 of 18 cases, intraprocedural unenhanced CT demonstrated selection of the right adrenal vein. CONCLUSIONS: CO2-intraprocedural unenhanced CT-AVS demonstrated the same diagnostic ability for PA localization as conventional AVS with iodine contrast media. The proposed method is clinically feasible for AVS, in which iodine contrast media use is restricted.


Asunto(s)
Hiperaldosteronismo , Hipersensibilidad , Yodo , Humanos , Flebografía/métodos , Medios de Contraste/efectos adversos , Dióxido de Carbono/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/irrigación sanguínea , Yodo/efectos adversos , Hiperaldosteronismo/diagnóstico por imagen , Estudios Retrospectivos , Aldosterona
2.
Tohoku J Exp Med ; 259(2): 127-133, 2023 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-36517016

RESUMEN

Laparoscopic adrenalectomy is currently the standard treatment modality for unilateral aldosterone-producing adenoma (APA); however, a less-invasive treatment is needed for its treatment. A new bipolar ablation system that poses a lower risk of complications has been recently developed. This study aimed to evaluate the safety and performance of a novel bipolar radiofrequency ablation (RFA) system for the treatment of APAs. Ablations were performed in an ex vivo study using bovine adrenal glands [group A: n = 6, single-probe; group B: n = 6, two probes, interprobe distance (ID) = 12 mm; group C: n = 6, two probes, ID = 20 mm]. The in vivo study was conducted in groups A and B (n = 2 each) using porcine adrenal glands. For the ex vivo study, the mean vertical diameter (Dv) of the coagulative necrosis area and the mean transverse diameter (Dt) values were 11.99 mm and 10.96 mm for group A, 12.66 mm and 10.0 mm for group B, and 23.37 mm and 22.10 mm for group C, respectively. For the in vivo study, the mean Dv and Dt values were 12.23 mm and 9.03 mm for group A, and 16.38 mm and 9.52 mm for group B, respectively. No heat-induced damage to the adjacent organs was observed. To our best knowledge, this is the first study to evaluate the performance of the bipolar system in RFA of the adrenal gland. RFA using the new bipolar ablation system is safe and produces a sufficient coagulation area to treat APAs.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Animales , Bovinos , Porcinos , Hígado/cirugía , Necrosis/cirugía , Glándulas Suprarrenales/cirugía
3.
BMC Nephrol ; 22(1): 187, 2021 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-34016044

RESUMEN

BACKGROUND: Fibromuscular dysplasia (FMD) often causes renal artery stenosis with renovascular hypertension. Recent clinical outcomes encourage percutaneous transluminal renal angioplasty (PTRA) to treat FMD; however, the necessary follow-up period remains unclear. Moreover, previous studies have not revealed the difference in the period until recurrence between two major types of FMD-multifocal and focal. CASE PRESENTATION: We describe two patients with multifocal FMD who developed hypertension during their teenage years and had recurrence of FMD > 10 years after PTRA. We further examined the types of FMD and age of onset in 26 patients who underwent PTRA. The period until recurrence of multifocal FMD was longer than that of focal FMD. Moreover, patients with early-onset multifocal FMD are likely to have a delayed recurrence after PTRA compared to other types. CONCLUSIONS: Our report suggests that patients with multifocal FMD, especially those with onset at an early age, may need long-term follow-up for at least ≥ 10 years.


Asunto(s)
Angioplastia , Displasia Fibromuscular/cirugía , Arteria Renal/cirugía , Adulto , Edad de Inicio , Continuidad de la Atención al Paciente , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia
4.
Tohoku J Exp Med ; 253(2): 143-150, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33658449

RESUMEN

Although adrenal resection is a major option to control hypercortisolemia in patients with bilateral macronodular adrenal hyperplasia, a predictive method for postoperative cortisol production has not been established. A 53-year-old man with ulcerative colitis was referred to our hospital for bilateral multiple adrenal nodules and hypertension. Physical and endocrinological examination revealed inappropriate cortisol production and suppressed secretion of adrenocorticotropic hormone with no typical signs of Cushing's syndrome. Imaging analysis revealed bilateral adrenal nodular enlargement, the nodules of which had the radiological features of adrenocortical adenomas without inter-nodular heterogeneity. In addition, computed tomography volumetry demonstrated that the left adrenal gland (70 mL) accounts for three quarters of the total adrenal volume (93 mL). The patient was diagnosed as subclinical Cushing's syndrome due to bilateral macronodular adrenal hyperplasia, and subsequently underwent a left laparoscopic adrenalectomy with the estimation of 75% decrease in the cortisol level based on the adrenal volume. The surgical treatment ultimately resulted in control of the cortisol level within the normal range, which was compatible to our preoperative prediction. However, regardless of the sufficient cortisol level, ulcerative colitis was exacerbated after the surgery, which needed a systemic therapy for remission. This case indicates successful surgical control of hypercortisolemia based on computed tomography volumetry in bilateral macronodular adrenal hyperplasia, as well as the perioperative exacerbation risk for inflammatory diseases in Cushing's syndrome. We report the potential utility of computed tomography volumetry as a quantitative method with retrospective evaluation of our historical cases.


Asunto(s)
Enfermedades de las Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/patología , Tomografía Computarizada por Rayos X , Enfermedades de las Glándulas Suprarrenales/cirugía , Glándulas Suprarrenales/cirugía , Hormona Adrenocorticotrópica/metabolismo , Anciano , Femenino , Humanos , Hidrocortisona/metabolismo , Hiperplasia , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
5.
J Vasc Interv Radiol ; 28(1): 50-59.e5, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27321887

RESUMEN

PURPOSE: To evaluate risk factors predicting death and complications of primary therapy for hepatic and gastric duodenal artery pseudoaneurysms following endovascular treatment (EVT) after pancreaticoduodenectomy (PD). MATERIALS AND METHODS: Between April 2004 and December 2014, 28 patients (mean age, 64.7 y) with post-PD hemorrhage underwent EVT. Prevention of hepatic artery blockage via stents or side-holed catheter grafts was stratified in cases without a replaced hepatic artery. Mortality and major hepatic complications following EVT were evaluated according to age; sex; surgery-EVT interval; presence of portal vein stenosis, shock, and coagulopathy at EVT onset; and post-EVT angiographic findings. RESULTS: All hemorrhages were successfully treated with microcoils (n = 17; 61%), covered stents (n = 1; 3%), bare stent-assisted coil embolization (n = 5; 18%), or catheter grafts with coil embolization (n = 5; 18%). Hepatic arterial flow was observed after EVT in 18 patients (64%). Mortality and major hepatic complication rates were 28.6% and 32.1%, respectively. Hemorrhagic shock and coagulopathy at EVT onset (n = 8 each; odds ratio [OR], 27; 95% confidence interval [CI], 3.1-235.7; P < .01) were significantly associated with mortality. Coagulopathy at EVT onset (adjusted OR [aOR], 48.1; 95% CI, 3.2-2,931), portal vein stenosis (n = 16; aOR, 16.9; 95% CI, 1.3-721.9), and no visualization of hepatopetal flow through the hepatic arteries (n = 10; aOR, 29.5; 95% CI, 2.1-1,477) were significantly associated with major hepatic complications. CONCLUSIONS: EVT should be performed as soon as possible before the development of shock or coagulopathy. Hepatic arterial flow visualization decreases major hepatic complications.


Asunto(s)
Aneurisma Falso/terapia , Aneurisma Roto/terapia , Embolización Terapéutica , Procedimientos Endovasculares , Arteria Hepática/lesiones , Pancreaticoduodenectomía/efectos adversos , Hemorragia Posoperatoria/terapia , Lesiones del Sistema Vascular/terapia , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/mortalidad , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/etiología , Aneurisma Roto/mortalidad , Angiografía por Tomografía Computarizada , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Arteria Hepática/diagnóstico por imagen , Humanos , Japón , Masculino , Persona de Mediana Edad , Pancreaticoduodenectomía/mortalidad , Hemorragia Posoperatoria/diagnóstico por imagen , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/mortalidad
6.
Radiology ; 278(1): 265-74, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26147784

RESUMEN

PURPOSE: To use segmental adrenal venous sampling (AVS) (S-AVS) of effluent tributaries (a version of AVS that, in addition to helping identify aldosterone hypersecretion, also enables the evaluation of intra-adrenal hormone distribution) to detect and localize intra-adrenal aldosterone secretion. MATERIALS AND METHODS: The institutional review board approved this study, and all patients provided informed consent. S-AVS was performed in 65 patients with primary aldosteronism (34 men; mean age, 50.9 years ± 11 [standard deviation]). A microcatheter was inserted in first-degree tributary veins. Unilateral aldosterone hypersecretion at the adrenal central vein was determined according to the lateralization index after cosyntropin stimulation. Excess aldosterone secretion at the adrenal tributary vein was considered to be present when the aldosterone/cortisol ratio from this vein exceeded that from the external iliac vein; suppressed secretion was indicated by the opposite pattern. Categoric variables were expressed as numbers and percentages; continuous variables were expressed as means ± standard errors of the mean. RESULTS: The AVS success rate, indicated by a selectivity index of 5 or greater, was 98% (64 of 65). The mean numbers of sampled tributaries on the left and right sides were 2.11 and 1.02, respectively. The following diagnoses were made on the basis of S-AVS results: unilateral aldosterone hypersecretion in 30 patients, bilateral hypersecretion without suppressed segments in 22 patients, and bilateral hypersecretion with at least one suppressed segment in 12 patients. None of the patients experienced severe complications. CONCLUSION: S-AVS could be used to identify heterogeneous intra-adrenal aldosterone secretion. Patients who have bilateral aldosterone-producing adenomas can be treated with adrenal-sparing surgery or other minimally invasive local therapies if any suppressed segment is identified at S-AVS.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Glándulas Suprarrenales/metabolismo , Aldosterona/sangre , Hiperaldosteronismo/sangre , Flebografía/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Angiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Eur Radiol ; 26(3): 622-30, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26108640

RESUMEN

OBJECTIVES: To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. METHODS: A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. RESULTS: The RAV was visualized in 93.2% by CT and 84.8% by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100% for CT and 95.2% for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16% of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70% of subjects. Success rate of AVS was 99.2%. CONCLUSIONS: Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. KEY POINTS: Dynamic CT and non-contrast-enhanced MR imaging detect the right adrenal vein (RAV). Dynamic CT can visualize the RAV more than non-contrast-enhanced MR imaging. Mapping the RAV helps to achieve successful adrenal venous sampling. Sixteen per cent of RAVs share the common trunk with accessory hepatic veins.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Hiperaldosteronismo/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada Multidetector/métodos , Imagen Multimodal/métodos , Flebografía/métodos , Glándulas Suprarrenales/diagnóstico por imagen , Adulto , Anciano , Variación Anatómica , Anatomía Transversal/métodos , Cateterismo Periférico/métodos , Medios de Contraste , Femenino , Venas Hepáticas/diagnóstico por imagen , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/estadística & datos numéricos , Imagen Multimodal/estadística & datos numéricos , Flebografía/instrumentación , Valor Predictivo de las Pruebas , Vena Cava Inferior/diagnóstico por imagen
8.
Ann Otol Rhinol Laryngol ; 124(2): 162-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25139135

RESUMEN

OBJECTIVES: The first objective was to describe a novel case of migration of a broken dental needle into the parapharyngeal space. The second was to address the importance of simulation elucidating visualization of such a thin needle under X-ray fluoroscopy. METHODS: Clinical case records (including computed tomography [CT] and surgical approaches) were reviewed, and a simulation experiment using a head phantom was conducted using the same settings applied intraoperatively. RESULTS: A 36-year-old man was referred after failure to locate a broken 31-G dental needle. Computed tomography revealed migration of the needle into the parapharyngeal space. Intraoperative X-ray fluoroscopy failed to identify the needle, so a steel wire was applied as a reference during X-ray to locate the foreign body. The needle was successfully removed using an intraoral approach with tonsillectomy under surgical microscopy. The simulation showed that the dental needle was able to be identified only after applying an appropriate compensating filter, contrasting with the steel wire. CONCLUSION: Meticulous preoperative simulation regarding visual identification of dental needle foreign bodies is mandatory. Intraoperative radiography and an intraoral approach with tonsillectomy under surgical microscopy offer benefits for accessing the parapharyngeal space, specifically for cases medial to the great vessels.


Asunto(s)
Instrumentos Dentales , Fluoroscopía/métodos , Migración de Cuerpo Extraño/cirugía , Agujas , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Faringe , Adulto , Migración de Cuerpo Extraño/diagnóstico , Humanos , Cuidados Intraoperatorios/métodos , Masculino , Cirugía Endoscópica por Orificios Naturales/métodos , Faringe/diagnóstico por imagen , Faringe/cirugía , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
J Vasc Surg ; 55(6): 1742-8, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22516891

RESUMEN

INTRODUCTION: Establishing an aneurysm model using simple and easy operative techniques is desirable to develop new endovascular treatment devices such as stent grafts. We developed an aneurysm model using the external iliac arteries (EIAs) of adult Beagles, a relatively large animal that we thought would be easy to handle, using simple and less complicated endovascular procedures. In addition, we evaluated the generated aneurysm model histologically and determined the factors that were necessary for creating more dilated aneurysms. METHODS: Experimental animals consisted of 16 beagles (average weight, 14.0 kg). The animals were divided into four groups (S, E, B+S, and B+E). Eight Beagles were in the S and E groups, without balloon dilation. S group Beagles were injected with normal saline into the right EIA and served as a control group. Elastase was injected into the left EIA of the same Beagles (E group). Eight Beagles were in the B+S and B+E groups with balloon dilation. After balloon dilation, normal saline was injected into right EIA of the B+S group. Elastase was injected into the left EIA of the same Beagles (B+E). After 4 weeks, we measured the EIA diameter using abdominal ultrasound imaging from a body surface. Both sides of the EIA were harvested. We evaluated the dilation rate of the EIA diameter, and histologically, evaluated the disappearance of the internal elastic lamina, degeneration and disappearance of medial smooth muscle and the external elastic lamina, and neointimal thickening. RESULTS: Inner diameters were dilated more in the B+E group vs the other groups. The B+E group internal elastic lamina had almost disappeared, with significantly more severe degeneration and disappearance of external elastic lamina. CONCLUSIONS: We developed a muscular artery aneurysm model using the EIA arteries of adult Beagles and a simple endovascular procedure. Histologically, internal and external elastic lamina degeneration was an important factor to create significantly dilated aneurysms in this muscular artery model.


Asunto(s)
Cateterismo/efectos adversos , Aneurisma Ilíaco/etiología , Arteria Ilíaca/patología , Elastasa Pancreática , Angiografía de Substracción Digital , Animales , Implantación de Prótesis Vascular , Dilatación Patológica , Modelos Animales de Enfermedad , Perros , Tejido Elástico/patología , Procedimientos Endovasculares , Aneurisma Ilíaco/diagnóstico , Aneurisma Ilíaco/patología , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Factores de Tiempo , Ultrasonografía
11.
J Vasc Interv Radiol ; 23(9): 1215-1221.e1, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22920981

RESUMEN

PURPOSE: To examine the properties of N-butyl cyanoacrylate (NBCA) and iodized oil (lipiodol [Lip]) in vitro and in vivo for safe and effective embolization. MATERIALS AND METHODS: Viscosity, polymerization time, and diffusing capacity were evaluated according to the NBCA/Lip ratio in vitro. Additionally, the effect of the NBCA/Lip ratio on arterial embolization was evaluated in vivo; various ratios of NBCA/Lip were injected into the renal arteries of adult beagles, after which the embolization effect following transcatheter arterial embolization was quantitatively investigated histopathologically and using computed tomography (CT) volumetry. RESULTS: The viscosity of NBCA/Lip increased, polymerization time was prolonged, and diffusing capacity increased as the NBCA density decreased. As the NBCA density decreased, embolic material was recognized in smaller diameter arteries, and embolization of a larger vascular bed was accomplished. The NBCA/Lip mixture with a low density of NBCA was located more peripherally from the catheter tip, and embolization of more peripheral and smaller diameter arteries was achieved. CONCLUSIONS: The relationships of properties of NBCA/Lip in vitro and embolization effects in vivo of various ratios of NBCA/Lip were quantitatively examined and compared. The results of this study are useful for safe and effective embolization.


Asunto(s)
Embolización Terapéutica/métodos , Enbucrilato/administración & dosificación , Aceite Etiodizado/administración & dosificación , Riñón/irrigación sanguínea , Arteria Renal , Animales , Difusión , Perros , Enbucrilato/química , Aceite Etiodizado/química , Inyecciones Intraarteriales , Riñón/diagnóstico por imagen , Riñón/patología , Polimerizacion , Arteria Renal/diagnóstico por imagen , Factores de Tiempo , Tomografía Computarizada por Rayos X , Viscosidad
12.
Cardiovasc Intervent Radiol ; 45(8): 1178-1185, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35606658

RESUMEN

PURPOSE: The aim was to evaluate a flexible device for transvenous adrenal gland radiofrequency ablation in vitro and in an in vivo animal model. MATERIALS AND METHODS: A flexible radiofrequency-tip catheter with an inner-cooling mechanism and a guidewire lumen was made. Then, using a polyvinyl alcohol gel model, the ablation diameter was evaluated and how much energy to deliver in vivo was determined. Finally, transvenous radiofrequency ablation of the left adrenal glands of two pigs was performed, delivering 5000 or 7000 J in a single dose to each. The ablation effects were also assessed by histological examination of hematoxylin-eosin-stained sections. RESULTS: The mean ablation diameters in the gel model were 20.2 and 21.9 mm in the short axis and 15 and 20 mm in the long axis for 5000 or 7000 J, respectively. The device was inserted into porcine left adrenal vein with no complications. The mean ablation diameters were 10 mm in the shorter axis (whole thickness of porcine left adrenal gland) in the porcine model for 7000 J. Transient increases in blood pressure and heart rate occurred during ablation. Histologically, the adrenal gland showed severe necrosis at ablated area. There was venous congestion upstream in a non-ablated area, and thermal damage to surrounding organs was not observed. CONCLUSIONS: A flexible radiofrequency-tip catheter could be inserted successfully into the left adrenal vein. The left adrenal gland was entirely ablated without any thermal damage to surrounding organs. We suggest transvenous adrenal ablation has potential as a therapeutic option for primary aldosteronism.


Asunto(s)
Ablación por Catéter , Glándulas Suprarrenales/cirugía , Animales , Presión Sanguínea , Ondas de Radio , Porcinos
13.
Sci Rep ; 12(1): 14090, 2022 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-35982148

RESUMEN

Evaluation of feasibility and safety of percutaneous radiofrequency ablation using bipolar radiofrequency devices in a prospective multicenter cohort of patients with benign aldosterone-producing adenoma. A total of five institutions participated. CT-guided percutaneous RFA was performed for patients diagnosed as APA. The safety of the procedure was evaluated using the Common Terminology Criteria for Adverse Events. During the 84-day follow-up period, serial changes in plasma aldosterone concentration and plasma renin activity were measured. The percentage of patients with normalized hormonal activity after the procedure, was calculated with 95% confidence intervals. Forty patients were enrolled, and two patients were excluded for cerebral hemorrhage and no safe puncture root. In another patients, RFA was tried, but an intraprocedural intercostal arterial injury occurred. Consequently, RFA was completed in thirty-seven patients (20 men, 17 women; mean age, 50.4 ± 10.0 year). The tumor size was 14.8 ± 3.8 mm. The treatment success rate of the ablation was 94.6% (35/37), and a 2nd session was performed in 2.7% (1/37) patients. Grade 4 adverse events were observed in 4 out of 38 sessions (10.5%). The normalization of plasma aldosterone concentration or aldosterone-renin ratio was 86.5% (72.0-94.1: 95% confidence interval) on day 84. Percutaneous CT-guided RFA for APA using a bipolar radiofrequency system was safe and feasible with clinical success rate of 86.5% on day 84.


Asunto(s)
Adenoma , Ablación por Catéter , Ablación por Radiofrecuencia , Adenoma/etiología , Adenoma/cirugía , Adulto , Aldosterona , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Electrodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/métodos , Renina , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
14.
Intern Med ; 60(2): 287-292, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-32830180

RESUMEN

Angioplasty for cases of chronic total occlusion of renal artery with/without atrophic kidney is generally not recommended. We herein report a 57-year-old man who presented with renin-mediated refractory hypertension caused by occlusion of a unilateral renal artery leading to kidney atrophy (length: 69 mm). Angioplasty favorably achieved blood pressure control with normalized renin secretion and enlargement of the atrophic kidney to 85 mm. Timely angioplasty can be beneficial in select patients, even with an atrophic kidney and total occlusion, especially in cases with deterioration of hypertension within six months and the presence of collateral perfusion to the affected kidney.


Asunto(s)
Angioplastia de Balón , Hipertensión Renovascular , Hipertensión , Obstrucción de la Arteria Renal , Angioplastia , Humanos , Hipertensión/complicaciones , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/complicaciones , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/cirugía
15.
Endocr Connect ; 10(1): 29-36, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33268573

RESUMEN

OBJECTIVES: This study compared cardiac function, morphology, and tissue characteristics between two common subtypes of primary aldosteronism (PA) using a 3T MR scanner. DESIGN: A retrospective, single-center, observational study. METHODS: We retrospectively reviewed 143 consecutive patients with PA, who underwent both adrenal venous sampling and cardiac magnetic resonance. We acquired cine, late gadolinium enhancement, and pre- and postcontrast myocardial T1-mapping images. RESULTS: PA was diagnosed as unilateral aldosterone-producing adenoma (APA) in 70 patients and bilateral hyperaldosteronism (BHA) in 73. The APA group showed significantly higher plasma aldosterone concentration (PAC) and aldosterone to renin rate (ARR) than the BHA group. After controlling for age, sex, antihypertensive drugs, systolic and diastolic blood pressure, and disease duration, the parameters independently associated with APA were: left ventricular end-diastolic volume index (EDVI: adjusted odds ratio (aOR) = 1.06 (95% CI: 1.030-1.096), P < 0.01), end-systolic volume index (ESVI: 1.06 (1.017-1.113), P < 0.01), stroke index (SI: 1.07 (1.020-1.121), P < 0.01), cardiac index (CI: 1.001 (1.000-1.001), P < 0.01), and native T1 (1.01 (1.000-1.019), P = 0.038). Weak positive correlations were found between PAC and EDVI (R = 0.28, P < 0.01), ESVI (0.26, P < 0.01), and SI (0.18, P = 0.03); and between ARR and EDVI (0.25, P < 0.01), ESVI (0.24, P < 0.01), and native T1 (0.17, P = 0.047). CONCLUSIONS: APA is associated with greater LV volumetric parameters and higher native T1 values, suggesting a higher risk of volume overload and myocardial damage.

16.
Radiographics ; 30(5): 1183-98, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20833844

RESUMEN

Ductal carcinoma in situ (DCIS) accounts for 20%-25% of breast cancers detected at screening mammography. The lesions are diverse and commonly are classified on the basis of their mammographic features and histologic characteristics such as nuclear grade and presence or absence of necrosis. The most common mammographic finding in DCIS is microcalcifications, but a low-grade lesion without necrosis is less likely to manifest with calcifications than either an intermediate- or a high-grade lesion. Other mammographic findings might include a mass or architectural distortion. Magnetic resonance (MR) imaging has higher sensitivity than mammography for the detection of DCIS and greater accuracy for depicting the extent of disease. The MR imaging appearance of DCIS depends primarily on the presence and extent of abnormal periductal or stromal vascularity. Nonmasslike enhancement, the most common MR imaging finding, is often seen in association with clumped internal enhancement. The enhancement kinetics in dynamic MR studies vary, and no kinetic pattern is pathognomonic of a particular nuclear grade of DCIS. However, the kinetic pattern at delayed imaging does appear to be correlated with the mammographic findings: Mass lesions show strong washout; fine pleomorphic, fine linear, and fine linear-branching calcifications demonstrate a plateau enhancement pattern; and amorphous calcifications exhibit persistent enhancement. Multidetector computed tomography might be a useful adjunct to MR imaging for preoperative mapping.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Calcinosis/diagnóstico , Carcinoma Ductal/diagnóstico , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Neoplasias de la Mama/complicaciones , Calcinosis/complicaciones , Carcinoma Ductal/complicaciones , Diagnóstico Diferencial , Femenino , Humanos , Estadística como Asunto
17.
Radiol Case Rep ; 15(11): 2125-2128, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32944111

RESUMEN

We describe treatment of a 53-year-old man with chronic hepatic encephalopathy. Contrast-enhanced computed tomography demonstrated a recanalized paraumbilical vein as a portosystemic shunt connecting the left branch of the portal vein and bilateral iliac veins. Percutaneous embolization was performed. The paraumbilical vein was punctured under ultrasonographic guidance; a 7-Fr sheath was inserted in the cranial direction. The hepatic side of the shunt was embolized with a vascular plug. The sheath direction was inverted to the caudal side; the pelvic side of the shunt was then embolized with another vascular plug. This report demonstrates that the percutaneous transparaumbilical venous approach is useful and safe for portosystemic shunt intervention. Moreover, the one-sheath inverse method was useful for embolization of upstream and downstream sides of the puncture site.

18.
Intern Med ; 59(9): 1173-1177, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31956203

RESUMEN

We report a case in which diffusion-weighted magnetic resonance imaging (DWI) demonstrated renal artery stenosis-related renal ischemia and the therapeutic efficacy of revascularization. The patient was a 73-year-old man, who underwent descending thoracic aortic replacement due to DeBakey IIIb chronic aortic dissection, and who showed progressive renal dysfunction due to right renal artery stenosis caused by false lumen thrombosis. DWI demonstrated a decreased apparent diffusion coefficient (ADC) in the right kidney, indicating renal ischemia. Angioplasty with stenting restored renal perfusion and improved the renal function, resulting in the normalization of the decreased ADC in the treated kidney. Thus, DWI can be used to monitor renal ischemia in cases involving advanced renal artery stenosis.


Asunto(s)
Aorta Torácica , Disección Aórtica/cirugía , Obstrucción de la Arteria Renal/diagnóstico , Trombosis/cirugía , Anciano , Angioplastia , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/diagnóstico por imagen , Obstrucción de la Arteria Renal/diagnóstico por imagen
19.
J Endocr Soc ; 4(2): bvaa004, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32099947

RESUMEN

Because of its rarity, our understanding of steroidogenesis in estrogen-producing adrenocortical adenoma, including the response to adrenocorticotropic hormone (ACTH) stimulation, remains limited. A 65-year-old man was referred to us because of primary aldosteronism and a right adrenal tumor. Endocrinological evaluations revealed secondary hypogonadism due to hyperestrogenemia. Adrenal venous sampling (AVS) and subsequent liquid chromatography-tandem mass spectrometry (LC-MS/MS) indicated bilateral hyperaldosteronism and a right estrogen-producing adrenocortical tumor. He subsequently underwent right unilateral adrenalectomy, which resulted in clinical remission of hypogonadism. Subsequent histopathological analysis identified a right estrogen-producing adrenocortical adenoma and multiple, concomitant adrenocortical micronodules. Sequential evaluation of steroid profiles using LC-MS/MS revealed unique hormone production, including adrenal androgens, and less responsiveness to ACTH in the right estrogen-producing adrenocortical adenoma as compared to the nonneoplastic adrenal cortex. This case study revealed unique profiles of steroid production in estrogen-producing adrenocortical adenoma associated with concomitant primary aldosteronism. Sequential steroid profiling analysis using LC-MS/MS in combination with AVS can contribute to the diagnosis of various adrenal disorders.

20.
Hypertens Res ; 43(11): 1214-1221, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32444857

RESUMEN

Renal artery stenosis causes kidney ischemia, reducing the size of the affected kidney, which eventually results in atrophy. Although renal atrophy is considered irreversible, resolution of the ischemia occasionally restores kidney size when the cause is renal artery stenosis. Angioplasty is effective in patients with nonatherosclerotic renovascular diseases (non-ARVDs). Nevertheless, renal enlargement after angioplasty has not been fully examined. We conducted a retrospective study to examine this phenomenon in non-ARVD patients. Ten patients with a <100-mm pole-to-pole length of the poststenotic kidney were treated with angioplasty. Data were collected up to 12 months after angioplasty. The mean age was 28 years; the estimated glomerular filtration rate was 92 ± 7 mL/min/1.73 m2 (mean ± SEM); blood pressure was 150/99 mmHg; 80% were women; and fibromuscular dysplasia was present in 90% of the patients. All patients had hypertension. The lengths of the poststenotic and contralateral kidney before angioplasty were 91 ± 1 and 111 ± 3 mm, respectively. After angioplasty, the length of the poststenotic kidney gradually increased during the 3 months after treatment (+5.4 mm) and that of the contralateral kidney decreased over the same time course (-3.7 mm). Enlargement was also found in the moderate atrophy subgroup (length < 92 mm), and it was greater in the <30 years old group. In a noteworthy case, renal size in the poststenotic kidney recovered from 87 to 102 mm after angioplasty. Our findings demonstrated that reduced renal size can be reversed after optimal angioplasty in non-ARVD patients, especially young patients, suggesting reversibility of the ischemic kidney.


Asunto(s)
Angioplastia , Hipertensión Renovascular/cirugía , Riñón/fisiología , Adolescente , Adulto , Femenino , Humanos , Hipertensión Renovascular/patología , Riñón/patología , Masculino , Tamaño de los Órganos , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA