Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556747

RESUMEN

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Asunto(s)
Fibrilación Atrial , Criocirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Potenciales de Acción , Frecuencia Cardíaca , Factores de Tiempo , Estudios Retrospectivos , Recurrencia , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología
2.
Circ J ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38763754

RESUMEN

BACKGROUND: Myocardial bridge (MB) is a common coronary anomaly characterized by a tunneled course through the myocardium. Coronary computed tomography angiography (CCTA) can identify MB. The impact of MB detected by CCTA on coronary physiological parameters before and after percutaneous coronary intervention (PCI) is unknown.Methods and Results: We investigated 141 consecutive patients who underwent pre-PCI CCTA and fractional flow reserve (FFR)-guided elective PCI for de novo single proximal lesions in the left anterior descending artery (LAD). We compared clinical demographics and physiological parameters between patients with and without CCTA-defined MB. MB was identified in 46 (32.6%) patients using pre-PCI CCTA. The prevalence of diabetes was higher among patients with MB. Median post-PCI FFR values were significantly lower among patients with than without MB (0.82 [interquartile range 0.79-0.85] vs. 0.85 [interquartile range 0.82-0.89]; P=0.003), whereas pre-PCI FFR values were similar between the 2 groups. Multivariable linear regression analysis revealed that the presence of MB and greater left ventricular mass volume in the LAD territory were independently associated with lower post-PCI FFR values. Multivariable logistic regression analysis also revealed that the presence of MB and lower pre-PCI FFR values were independent predictors of post-PCI FFR values ≤0.80. CONCLUSIONS: CCTA-defined MB independently predicted both lower post-PCI FFR as a continuous variable and ischemic FFR as a categorical variable in patients undergoing elective PCI for LAD.

3.
PLoS One ; 19(8): e0307384, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39146288

RESUMEN

BACKGROUND: Stress-transthoracic Doppler echocardiography (S-TDE) provides a noninvasive assessment of coronary flow parameters in the left anterior descending artery (LAD). However, the association between morphological characteristics and coronary flow changes after elective percutaneous coronary intervention (PCI) remains unclear. We aimed to evaluate the relationships between periprocedural coronary flow changes observed on S-TDE and lesion-specific plaque characteristics obtained by optical coherence tomography (OCT) in the interrogated vessels in patients with chronic coronary syndrome (CCS). METHODS AND RESULTS: Patients with CCS who underwent pre- and post-PCI S-TDE and elective fractional flow reserve (FFR)-guided PCI under OCT guidance for de novo single LAD lesions were included. S-TDE-derived hyperemic diastolic peak flow velocity (hDPV) was used as a surrogate for coronary flow. Lesions were categorized into two groups based on the %hDPV increase or decrease. The baseline clinical, physiological, and OCT findings were compared between the groups. In total, 103 LAD lesions were studied in 103 patients. After PCI, hDPV significantly increased from 55.6 cm/s to 69.5 cm/s (P<0.01), with a median %hDPV increase of 27.2 (6.32-59.1) %, while %hDPV decreased in 20 (19.4%) patients. The FFR improved in all patients. On OCT, layered plaques were more frequently present in the culprit vessels in the %hDPV-decrease group than in the %hDPV-increase group (85.0% vs. 50.6%, P = 0.01). Multivariable logistic regression analysis showed that the presence of layered plaques and high pre-PCI hDPV were independent predictors of %hDPV decrease. CONCLUSIONS: In patients who underwent successful uncomplicated elective PCI for de novo single LAD lesions, the presence of layered plaques was independently associated with hyperemic coronary flow decrease as assessed by S-TDE.


Asunto(s)
Ecocardiografía Doppler , Intervención Coronaria Percutánea , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Intervención Coronaria Percutánea/métodos , Ecocardiografía Doppler/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/patología , Stents , Reserva del Flujo Fraccional Miocárdico , Hiperemia/diagnóstico por imagen , Hiperemia/fisiopatología , Circulación Coronaria/fisiología , Velocidad del Flujo Sanguíneo , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA