Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31904800

RESUMEN

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 95(3): 398-407, 2020 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-31609073

RESUMEN

AIMS: To evaluate outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) using three different new-generation devices. BACKGROUND: Although new generation transcatheter aortic valves (TAVs) have demonstrated to improve procedural outcomes, to date few head-to-head comparisons are available among these devices. METHODS: This is a single center, retrospective study. From September 2014 to February 2018, 389 patients underwent elective TF-TAVI for native, severe aortic stenosis using a new-generation transcatheter aortic valve (TAV) with a preprocedural multi-detector computed tomography assessment. Among these, 346 patients received an Edwards SAPIEN 3 (n = 134), Medtronic Evolut R (n = 111), or Boston ACURATE neo (n = 101) prosthesis. Differences in baseline clinical characteristics between groups were accounted using the propensity score weighting method. RESULTS: The mean age for the entire study cohort was 81.4 ± 5.2 years while the Society of Thoracic Surgery predicted risk of mortality was 4.0 ± 2.5%. After propensity score weighting adjustment, TAVs did not differently impact on 30-day all-cause and cardiovascular mortality. Evolut R device showed an increased risk of permanent pacemaker implantation (PPI) after the procedure (8.3% for SAPIEN 3 vs. 16.7% for Evolut R vs. 2.1% for ACURATE neo, p < .05). At 30 days, patients treated with SAPIEN 3 valve showed a higher mean transvalvular gradient (9.7 ± 7.5 mmHg vs. 6.1 ± 2.4 mmHg vs. 8.4 ± 3.5 mmHg for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01) and a lower rate of more-than-trace paravalvular regurgitation (PVR) (18.8 vs. 47.9 vs. 45.8%, for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01). At 1 year, SAPIEN 3, Evolut R, and ACURATE neo TAVs showed excellent and comparable outcomes with no difference in terms of freedom from major adverse cardiovascular and cerebrovascular event (MACCE) (plog-rank = 0.534). CONCLUSIONS: TAVI using new-generation prostheses was associated with high device success (97.0% vs. 92.8% vs. 95.0% for SAPIEN 3, Evolut R and ACURATE neo, respectively) and low complications rates up to 1 year. Evolut R valve was associated with a higher rate of PPI whereas SAPIEN 3 valve was associated with a higher mean transvalvular gradient and lower rate of more-than-trace PVR. At 1-year, MACCE rates were similar among the three groups.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 85(4): E99-E107, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25154722

RESUMEN

OBJECTIVES: We performed systematic optical coherence tomography (OCT) analyses after bioresorbable vascular scaffolds (BVS) implantation in a "real world" setting aiming at evaluating scaffold expansion and longitudinal integrity. BACKGROUND: a comprehensive elucidation of BVS acute performance in the "real-world" setting is lacking. METHODS: acute BVS expansion compared with compliance chart information and longitudinal integrity were assessed in 29 patients (32 lesions) by OCT. In addition, bench experiments with four scaffolds were performed with different combinations of deployment pressures and tube stiffness. RESULTS: scaffold underexpansion, using compliance chart information as reference, was observed in 97% of OCT cross-sections in vivo; however, only 8.3% of the cross-section analyzed revealed BVS area <5 mm(2) . Calcified plaques were more common in the lowest (9.7%) compared with the mid (8.8%) and highest (6.3%) tertiles of scaffold expansion (P = 0.003 and P = 0.001 for lowest vs. mid, and lowest vs. highest, respectively). Seventeen (54.8%) scaffolds were elongated during implantation, but no signs of scaffold fracture were revealed. Elongation and impaired expansion were reproduced in the bench testing when the scaffold was deployed with high pressure in a hard tube. CONCLUSIONS: compliance chart information should not be used to predict final BVS dimensions in the clinical setting. While BVS expansion could be potentially impaired by calcified plaques, they may elongate during deployment. Bench experiments confirmed the elongation phenomenon when BVS were deployed with high pressure in hard tubes.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Calcificación Vascular/terapia , Anciano , Adaptabilidad , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/patología , Femenino , Humanos , Italia , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Placa Aterosclerótica , Presión , Diseño de Prótesis , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Calcificación Vascular/diagnóstico
4.
JACC Cardiovasc Interv ; 17(6): 727-737, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456879

RESUMEN

BACKGROUND: Coronary re-engagement after transcatheter aortic valve replacement (TAVR) using self-expanding transcatheter heart valves (THVs) systematically implanted using commissural alignment (CA) techniques has been poorly investigated. OBJECTIVES: The aim of this study was to evaluate unsuccessful coronary cannulation, and its predictors, after TAVR using self-expanding devices implanted using CA techniques. METHODS: RE-ACCESS 2 (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent 2) was an investigator-driven, single-center, prospective study that enrolled consecutive TAVR patients receiving Evolut and ACURATE THVs implanted using CA techniques. The primary endpoint was unsuccessful coronary cannulation after TAVR. The secondary endpoint was the identification of postprocedural predictors of unfeasible, selective coronary ostia re-engagement on computed tomographic angiography performed after TAVR. RESULTS: Among 127 patients enrolled from September 2021 to December 2022, 7 (5.5%) had unsuccessful coronary cannulation after TAVR, and 6 of them received Evolut THVs (7.5% vs 2.3%; P = 0.26). Failure of left coronary artery cannulation was similar between Evolut and ACURATE THVs (2.5% vs 2.1%; P = 1.00), whereas that of right coronary artery cannulation was prevalent in the Evolut group (6.3% vs 0.0%; P = 0.16). Coronary overlap was associated with the inability to selectively cannulate the right coronary artery (OR: 5.6; 95% CI: 1.2-25.8; P = 0.03), but not in ACURATE recipients (P = 0.39). Severe misalignment of Evolut THVs was associated with the inability to selectively cannulate both coronary arteries (OR: 24.7; 95% CI: 1.9-312.9; P = 0.01). CONCLUSIONS: Unsuccessful coronary cannulation after TAVR using self-expanding THVs implanted using CA techniques was reported in 5.5% of cases, with the majority involving the Evolut THV. Commissural misalignment affected coronary cannulation after TAVR mostly in Evolut recipients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Factores de Riesgo , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Cateterismo
5.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
6.
J Clin Med ; 13(12)2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38930026

RESUMEN

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

7.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
8.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
9.
Catheter Cardiovasc Interv ; 82(4): E446-52, 2013 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-23592634

RESUMEN

OBJECTIVES: To externally validate the logistic clinical SYNTAX in patients undergoing percutaneous coronary intervention (PCI) of the left main coronary artery (LMCA). BACKGROUND: A novel version of the clinical SYNTAX score (CSS) has been recently introduced to overcome the limitations of categorical risk scores for PCI by the incorporation of clinical variables and the SYNTAX score (SXscore) into a logistic formula for predicting 1-year mortality. METHODS: Core and extended models of the logistic CSS (logCSS(core) and logCSS(ext)) were applied to 400 patients undergoing LMCA PCI, and their performance was compared with those of the standard CSS, SXscore, and age, creatinine, and ejection fraction (ACEF) score by different measures of discrimination and calibration. RESULTS: A significant gradient in the distribution of 1-year mortality was noted with all the models (P < 0.001), with the SYNTAX and ACEF scores showing the lowest (0.64) and the highest (0.75) c-statistic, respectively. Based on Somers' D(xy) rank correlation, discrimination of both the logCSS(core) and the logCSS(ext) was numerically lower than that of the ACEF score. The logCSS(core) was miscalibrated toward underpredicting all-cause mortality in low-predicted probabilities, while the logCSS(ext) tended to underpredict in low-predicted probabilities and overpredict in high-predicted probabilities. Slope and intercept values reflected a better calibration ability of the logCSS(core) compared with the logCSS(ext). The global accuracy of the logCSS(core) was superior to that of the logCSS(ext) (Brier score 0.087 vs. 0.095). CONCLUSIONS: A personalized approach to risk stratification of LMCA PCI with the logistic CSS is feasible and of potential clinical utility. However, in this study, the logistic CSS did not achieve superior discrimination compared with other categorical models, and suffered from mild to moderate miscalibration.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Técnicas de Apoyo para la Decisión , Intervención Coronaria Percutánea/mortalidad , Factores de Edad , Biomarcadores/sangre , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Creatinina/sangre , Humanos , Modelos Logísticos , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Curva ROC , Sistema de Registros , Reproducibilidad de los Resultados , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
10.
Minerva Cardiol Angiol ; 71(3): 311-320, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36305774

RESUMEN

BACKGROUND: The safety of concomitant percutaneous coronary intervention (PCI) during transcatheter aortic valve implantation (TAVI) setting is still highly debated. This study aimed to assess the safety and the effectiveness of TAVI and PCI performed in the same session compared with TAVI alone. METHODS: Patients with severe aortic stenosis and coronary artery disease (CAD) (N.=786) who underwent TAVI from June 2007 to April 2021 were divided into two groups: patients who underwent TAVI alone (N.=633) and patients treated with TAVI and concomitant PCI (N.=153). The propensity-score matching adjustment was used to account for baseline confounding variables. RESULTS: A total of 302 TAVI with CAD patients (151 matched pairs), undergoing either isolated TAVI or TAVI+PCI were compared. In-hospital death (6% vs. 4%; P=0.427), stroke (2% vs. 0.7%; P=0.314), myocardial infarction (MI) (0% vs. 0.7%; P=0.317), major and life-threatening bleeding (14.6% vs. 15.9%; P=0.749), and acute kidney injury (9.3% vs. 10.6%; P=0.700) were similar for both groups. At 3 years, the rates of all-cause death (25.2% vs. 19.2%; P=0.615), the composite endpoints of all-cause death and MI (27.2% vs. 21.2%; P=0.699) and all-cause death, MI, and stroke (28.5% vs. 22.5%; P=0.739) were also comparable between the two groups. Achieving complete coronary revascularization in the TAVI setting did not impact on long-term mortality (P=0.257). CONCLUSIONS: In patients with severe aortic stenosis and CAD, concomitant TAVI and PCI was as safe and effective as TAVI alone up to 3-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Mortalidad Hospitalaria , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Infarto del Miocardio/epidemiología , Infarto del Miocardio/cirugía , Accidente Cerebrovascular/complicaciones
11.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
12.
J Cardiovasc Echogr ; 32(3): 168-171, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36619783

RESUMEN

We present the case of a 69-year-old man with an aortic biological prosthetic valve. In May 2019, the patient experienced increasing dyspnea and fatigue: A diagnosis of prosthetic aortic valve dysfunction was made, leading to severe valvular insufficiency. The dysfunction of the prosthetic valve seemed to be linked to a previous infective endocarditis: after ruling out active endocarditis, the patient was treated with an off-label valve-in-valve transcatheter aortic valve implantation.

13.
JACC Case Rep ; 4(2): 83-86, 2022 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-35106489

RESUMEN

Achieving patient-specific commissural alignment of transcatheter aortic valves is particularly important to ensure coronary reaccess after transcatheter aortic valve implantation. Nevertheless, in case of uncommon origin of coronary arteries, commissural alignment could be counterproductive. This case shows how alignment techniques could serve to intentionally misalign the neocommissures in this subset of patients. (Level of Difficulty: Intermediate.).

14.
G Ital Cardiol (Rome) ; 23(6): 461-468, 2022 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-35674037

RESUMEN

BACKGROUND: To assess the longitudinal changes in transcatheter aortic valve implantation (TAVI) practice and patients' outcomes in a high-volume Italian center. METHODS: We analyzed all patients undergoing TAVI at our Institution from June 2007 to August 2021. We stratified the overall population considering four time periods according to procedural advancements and changes in clinical practice: period 1 (2007-2009, n=107) vs period 2 (2010-2014, n=449) vs period 3 (2015-2019, n=864) vs period 4 (2019-2021, n=638). Baseline and procedural characteristics, and in-hospital outcomes among the four groups were compared. RESULTS: A total of 2058 patients underwent TAVI receiving all the available devices. Patients had a median age of 82 years (78-85) with no differences among time periods. A stepwise reduction of median Society of Thoracic Surgeons mortality risk score (3.7 [2.8-5.3] vs 3.6 [2.6-5.4] vs 3.6 [2.5-5.5] vs 3.3 [2.2-4.9]; p=0.01) was observed. In-hospital all-cause-death (7.5% vs 5.1% vs 2.9% vs 3.0%; p<0.05), major stroke (4.7% vs 0.7% vs 1.0% vs 0.8%; p<0.05), major vascular complications (17.8% vs 8.7% vs 10.5% vs 5.8%; p<0.05) and permanent pacemaker implantation (23.4% vs 12.0% vs 8.7% vs 8.8%; p<0.05) rates significantly lowered over time. Device success markedly improved (80.4% vs 87.1% vs 95.0% vs 96.3%; p<0.05) with significant improvement of paravalvular regurgitation after TAVI (moderate-to-severe 16.8% vs 8.1% vs 0.7% vs 0.2%; mild 61.4% vs 38.2% vs 38.5% vs 25.6%; p<0.05). CONCLUSIONS: All-cause death and in-hospital outcomes of patients undergoing TAVI significantly improved accordingly to technical advancements and changes in clinical practice over 15-year experience.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Fluoroscopía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
15.
Int J Cardiol ; 352: 190-194, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35077726

RESUMEN

BACKGROUND: The coronavirus 2019 (COVID-19) pandemic upset healthcare systems and their logistics worldwide. We sought to assess safety and effectiveness of an optimized logistics for transcatheter aortic valve implantation (TAVI) pathway developed during the COVID-19 pandemic. METHODS: This is a retrospective analysis. An optimized TAVI logistics based on performing TAVI work-up and procedure during the same hospitalization was used during the COVID-19 pandemic. In-hospital and 30-day outcomes of patients treated during the pandemic were compared with an historical cohort of patients undergoing TAVI with staged work-up before the pandemic within an homogeneous timeframe. RESULTS: Of 536 patients, 227 (42.4%) underwent TAVI during the COVID-19 pandemic with a reduction of 26.5% compared to the pre-pandemic period (n = 309). The median age was 81 (77-85) years and STS score was 3.4 (2.2-5.6)%. Lower rates of in-hospital major vascular complications (2.2% vs. 8.7%; p < 0.01) and life-threatening bleeding (0.4% vs. 4.2%; p = 0.01) were reported in the COVID-19 period, whereas no difference in acute kidney injury (7.0% vs. 7.4%, p = 0.85) rate was reported between COVID-19 and pre-COVID-19 periods. No difference in 30-day rates of all-cause death (4.0 vs. 4.5, p = 0.75) and of major adverse cardiovascular events (4.0 vs. 6.1, p = 0.26) were reported between COVID-19 and pre-COVID-19 periods. CONCLUSIONS: The use of optimized single-hospitalization logistics for TAVI workup and procedure developed during the COVID-19 pandemic, showed to be as safe and effective as the two-stage TAVI pathway previously adopted, allowing the minimization of potential exposure to COVID-19 infection and shortening times to treatment for severely symptomatic patients.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , COVID-19/epidemiología , Atención a la Salud , Humanos , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
16.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35595675

RESUMEN

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 15(23): 2398-2407, 2022 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-36121242

RESUMEN

BACKGROUND: The latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes. OBJECTIVES: This study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices. METHODS: The OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively. RESULTS: Among 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01). CONCLUSIONS: The OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.


Asunto(s)
Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
EuroIntervention ; 17(9): 728-735, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-33589411

RESUMEN

BACKGROUND: Vascular complications still represent an important issue after transcatheter aortic valve implantation (TAVI). AIMS: The aim of this study was to evaluate the effectiveness of upfront use of an adjunctive Angio-Seal (AS) plug-based system on top of suture-based devices (SBDs) for endovascular haemostasis after transfemoral (TF) TAVI. METHODS: From January 2019 to April 2020, 332 consecutive patients with preprocedural computed tomography angiography (CTA) assessment underwent fully percutaneous TF-TAVI. The primary outcomes were 30-day major vascular complications and major or life-threatening (LT) bleeding due to endovascular closure system failure. A total of 246 TF-TAVI patients (123 pairs), undergoing either isolated SBD or SBD+AS, were matched using the propensity-score method. RESULTS: At 30 days, patients receiving SBD+AS had lower rates of major/LT bleeding (1.6% vs 8.9%, odds ratio [OR] 0.17, 95% confidence interval [CI]: 0.04-0.78; p<0.01) and major vascular complications (1.6% vs 8.9%, OR 0.17, 95% CI: 0.04-0.78; p<0.01). In addition, the use of SBD+AS was associated with a significant cost saving related to the vascular event (mean difference -315.3 € per patient, 95% CI: -566.4 € to -64.1 €; p=0.01), and a higher probability of next-day discharge (NDD) after TAVI (30.9% vs 16.3%, OR 2.30, 95% CI: 1.25-4.25; p<0.01). No difference in all-cause 30-day mortality was observed (3.3% vs 1.6% for SBD and SBD+AS groups, respectively, OR 0.49, 95% CI: 0.09-2.74; p=0.41). CONCLUSIONS: An upfront combined strategy with an additional AS plug-based device on top of SBDs was shown to reduce major vascular complications and major/LT bleeding due to closure system failure after TF-TAVI. This approach was associated with a cost saving and with a higher probability of NDD compared to the use of isolated SBD. Visual summary. Effectiveness of the upfront combined strategy for endovascular haemostasis in transfemoral transcatheter aortic valve implantation using Angio-Seal on top of a suture-based device (SBD) versus the isolated use of SBD. LT: life-threatening; TF-TAVI: transfemoral transcatheter aortic valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hemostasis , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
J Cardiovasc Echogr ; 30(3): 154-161, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33447506

RESUMEN

BACKGROUND: According to the actual guidelines regarding severe aortic valve stenosis (AS), symptoms are the most important trigger for aortic valve replacement (AVR). However, the objective analysis of cardiological clinic can be confused, considering the aging population this disease affects and the comorbidities. OBJECTIVES: Looking for an objective marker of disease, useful for scheduling the correct AVR, we researched the relation between some biochemical markers of left ventricular (LV) dysfunction and its global longitudinal strain. MATERIALS AND METHODS: We analyzed 74 consecutive patients (82 ± 4 years) with severe AS. We identified 61 patients with symptoms (angina, dyspnea, and syncope) and 13 asymptomatic patients. The clinical and echocardiographic parameters were compared between these two groups. LV ejection fraction (LVEF), LV global longitudinal strain (LVGLS), NT-pro-B-type brain natriuretic peptide (BNP), troponin T (TNT), creatine kinase-MB (CPK-MB), and myoglobin were determined at the time of evaluation. RESULTS: Compared with the asymptomatic group, patients in the symptomatic group had a lower LVGLS (P = 0.002) and an increased pro-BNP (P = 0.0002). LVGLS showed a good correlation with pro-BNP as a marker of myocardial damage, with a linear increase of pro-BNP in patients with a linear decrease of LVGLS (r = 0.43). Despite the normal value of LVEF > 50% in asymptomatic patients, some of them (46%) have an early dysfunction of LVGLS. No other statistically significant difference emerged from the biochemical analysis, in TNT (P = 0.29), CPK-MB (P = 0.36), and myoglobin (P = 0.38). CONCLUSIONS: Pro-BNP and LVGLS can be considered an objective marker of clinical severity of AS disease, useful for management and scheduling of AVR, especially in asymptomatic patients.

20.
EuroIntervention ; 16(6): e494-e501, 2020 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32091404

RESUMEN

AIMS: The aim of this study was to evaluate predictors and safety of next-day discharge (NDD) after transfemoral transcatheter aortic valve implantation (TF-TAVI) in unselected patients receiving either balloon-expandable or self-expanding devices. METHODS AND RESULTS: From June 2007 to August 2018, 1,232 consecutive patients undergoing TF-TAVI were discharged alive from our institution. They had a mean age of 80.9±5.4 years and an intermediate estimated surgical mortality risk; they received either balloon-expandable (26.1%) or self-expanding prostheses (73.9%). We compared patients discharged within 24 hours from the procedure (n=160, 13.0%) with those discharged later, and accounted for confounding variables through a propensity matching adjustment. After adjustment, no differences in all-cause mortality (1.2% vs 0.0%, for NDD and no-NDD matched groups, respectively, p=0.16) or permanent pacemaker implantation (PPI) after TAVI (0.6% vs 0.6%, respectively) were encountered at 30 days. At one year, no difference in the composite endpoint of all-cause death and heart failure (HF) rehospitalisation was encountered (Kaplan-Meier [KM] estimates 91.9% vs 90.6% for NDD and no-NDD matched groups, respectively, p=0.69). After excluding patients with post-procedural major complications from the unmatched population, prior PPI (OR 2.06, 95% CI: 1.21-3.51; p<0.01) and availability of preprocedural computed tomography angiography (CTA) (OR 1.71, 95% CI: 1.15-2.54; p<0.01) were found to be predictors of NDD after TAVI. CONCLUSIONS: NDD in unselected patients after TF-TAVI using either balloon-expandable or self-expanding devices was demonstrated to be a safe strategy up to one year in the absence of procedural complications. Patients with prior PPI and undergoing preprocedural CTA had a higher chance of NDD.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Alta del Paciente/normas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Femenino , Humanos , Tiempo de Internación , Masculino , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA