Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
PLoS One ; 14(1): e0211207, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30689658

RESUMEN

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization. BD Biosciences sponsored the clinical evaluation of the BD FACSLyric 10-color configuration at seven clinical sites using delinked and de-identified blood specimens from HIV-infected and uninfected subjects to enumerate T-, B-, and NK-lymphocytes with the BD Multitest™ reagents (BD Multitest IMK kit and BD Multitest 6-color TBNK). Samples were analyzed on the BD FACSLyric system with BD FACSuite Clinical software, and on the BD FACSCanto™ II system with BD FACSCanto clinical software and BD FACS 7-Color Setup beads. For equivalency between methods, data (n = 362) were analyzed with Deming regression for absolute count and percentage of lymphocytes. Results gave R2 ≥0.98, with slope values ≥0.96, and slope ranges between 0.90-1.05. The percent (%) bias values were <10% for T- and NK cells and <15% for B- cells. The between-site (n = 4) total precision was tested for 5 days (2 runs/day), and gave %coefficient of variation below 10% for absolute cell counts. The stability claims were confirmed (n = 186) for the two BD Multitest reagents. The reference intervals were re-established in male and female adults (n = 134). The analysis by gender showed statistically significant differences for CD3+ and CD4+ T-cell counts and %CD4. In summary, the BD FACSLyric and the BD FACSCanto II systems generated comparable measurements of T-, B-, and NK-cells using BD Multitest assays.


Asunto(s)
Linfocitos B/citología , Recuento de Células/métodos , Células Asesinas Naturales/citología , Linfocitos T/citología , Linfocitos T CD4-Positivos/citología , Recuento de Células/normas , Citometría de Flujo , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/inmunología , Humanos , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Reproducibilidad de los Resultados
2.
Cytometry B Clin Cytom ; 94(1): 129-135, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-27221715

RESUMEN

BACKGROUND: CD49d is emerging as a powerful adverse prognostic marker in chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL). However, flow cytometric testing for CD49d has not yet been widely adopted in the United States, in part due to the lack of establishment of its performance characteristics in the clinical setting, especially in comparison with the more common CLL/SLL prognostic markers CD38 and ZAP-70. METHODS: CD49d expression levels in 124 CLL/SLL cases were assessed among peripheral blood (PB), bone marrow (BM), and lymph node (LN) specimens and correlated with available CD38 and ZAP-70 expression and cytogenetic findings. For 10 PB/BM specimens, the stability of CD49d, CD38, and ZAP-70 expression was assessed at <24 hours, 48 hours, 72 hours, and 96 hours. RESULTS: 39% (28 of 71) PB, 56% (18 of 32) BM, and 71% (15 of 21) LN involved by CLL/SLL were CD49d+, using a ≥30% threshold. The mean for the CD49d+ cases was 2.8 standard deviations (SD) above the cutoff for positivity, compared with 1.7 SD for CD38 and 1.1 SD for ZAP-70. CD49d demonstrated the lowest mean SD (0.91) and coefficient of variation (CV) (8.0%) compared with CD38 (SD = 2.1, CV = 10.4%) and ZAP-70 (SD = 9.8, CV = 40.5%) in stability studies over a 96-hours time period. CD49d+ CLL/SLL correlated with trisomy 12 (P = 0.025) and lack of isolated deletion (13q) (P = 0.005). CD38+ CLL/SLL correlated with deletion (11q) (P = 0.025). ZAP-70 did not correlate with any underlying cytogenetic abnormality. CONCLUSIONS: CD49d is a robust adverse prognostic marker in CLL/SLL with superior performance characteristics. © 2016 International Clinical Cytometry Society.


Asunto(s)
Integrina alfa4/metabolismo , Leucemia Linfocítica Crónica de Células B/diagnóstico , Leucemia Linfocítica Crónica de Células B/metabolismo , ADP-Ribosil Ciclasa 1/metabolismo , Biomarcadores de Tumor/metabolismo , Médula Ósea/metabolismo , Aberraciones Cromosómicas , Citometría de Flujo/métodos , Humanos , Pronóstico , Proteína Tirosina Quinasa ZAP-70/metabolismo
3.
Cytometry B Clin Cytom ; 90(5): 404-14, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26525599

RESUMEN

OBJECTIVES: Flow cytometry is an important tool for identification of neoplastic T-cells, but immunophenotypic abnormalities are often subtle and must be distinguished from nonneoplastic subsets. Use of internal control (IC) T-cells in the evaluation for T-cell neoplasms was explored, both as a quality measure and as a reference for evaluating abnormal antigen expression. METHODS: All peripheral blood specimens (3-month period), or those containing abnormal T-cells (29-month period), stained with CD45 V500, CD2 V450, CD3 PE-Cy7, CD7 PE, CD4 Per-CP-Cy5.5, CD8 APC-H7, CD56 APC, CD16&57 FITC, were evaluated. IC T-cells were identified (DIVA, BD Biosciences) and median fluorescence intensity (MFI) recorded. Selected files were merged and reference templates generated (Infinicyt, Cytognos). RESULTS: IC T-cells were present in all specimens, including those with abnormal T-cells, but subsets were less well-represented. IC T-cell CD3 MFI differed between instruments (p = 0.0007) and subsets (p < 0.001), but not specimen categories, and served as a longitudinal process control. Merged files highlighted small unusual IC-T subsets: CD2+(dim) (0.25% total), CD2- (0.03% total). An IC reference template highlighted neoplastic T-cells, but was limited by staining variability (IC CD3 MFI reference samples different from test (p = 0.003)). CONCLUSIONS: IC T-cells present in the majority of specimens can serve as positive and longitudinal process controls. Use of IC T-cells as an internal reference is limited by variable representation of subsets. Analysis of merged IC T-cells from previously analyzed patient samples can alert the interpreter to less-well-recognized non-neoplastic subsets. However, application of a merged file IC reference template was limited by staining variability. © 2016 Clinical Cytometry Society.


Asunto(s)
Citometría de Flujo , Trastornos Linfoproliferativos/diagnóstico , Neoplasias/diagnóstico , Subgrupos de Linfocitos T/inmunología , Complejo CD3/metabolismo , Citometría de Flujo/métodos , Humanos , Inmunofenotipificación , Trastornos Linfoproliferativos/inmunología , Neoplasias/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA