Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Neuroimage ; 296: 120666, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38830440

RESUMEN

Direct imaging of semi-solid lipids, such as myelin, is of great interest as a noninvasive biomarker of neurodegenerative diseases. Yet, the short T2 relaxation times of semi-solid lipid protons hamper direct detection through conventional magnetic resonance imaging (MRI) pulse sequences. In this study, we examined whether a three-dimensional ultrashort echo time (3D UTE) sequence can directly acquire signals from membrane lipids. Membrane lipids from red blood cells (RBC) were collected from commercially available blood as a general model of the myelin lipid bilayer and subjected to D2O exchange and freeze-drying for complete water removal. Sufficiently high MR signals were detected with the 3D UTE sequence, which showed an ultrashort T2* of ∼77-271 µs and a short T1 of ∼189 ms for semi-solid RBC membrane lipids. These measurements can guide designing UTE-based sequences for direct in vivo imaging of membrane lipids.


Asunto(s)
Membrana Eritrocítica , Imagen por Resonancia Magnética , Lípidos de la Membrana , Vaina de Mielina , Humanos , Imagen por Resonancia Magnética/métodos , Vaina de Mielina/química , Membrana Eritrocítica/química , Membrana Eritrocítica/metabolismo , Lípidos de la Membrana/química , Liofilización , Eritrocitos/metabolismo
2.
Skeletal Radiol ; 53(5): 881-890, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37935923

RESUMEN

PURPOSE: To investigate the feasibility and application of a novel imaging technique, a three-dimensional dual adiabatic inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence, for high contrast assessment of cartilaginous endplate (CEP) imaging with head-to-head comparisons between other UTE imaging techniques. METHOD: The DIR-UTE sequence employs two narrow-band adiabatic full passage (AFP) pulses to suppress signals from long T2 water (e.g., nucleus pulposus (NP)) and bone marrow fat (BMF) independently, followed by multispoke UTE acquisition to detect signals from the CEP with short T2 relaxation times. The DIR-UTE sequence, in addition to three other UTE sequences namely, an IR-prepared and fat-saturated UTE (IR-FS-UTE), a T1-weighted and fat-saturated UTE sequence (T1w-FS-UTE), and a fat-saturated UTE (FS-UTE) was used for MR imaging on a 3 T scanner to image six asymptomatic volunteers, six patients with low back pain, as well as a human cadaveric specimen. The contrast-to-noise ratio of the CEP relative to the adjacent structures-specifically the NP and BMF-was then compared from the acquired images across the different UTE sequences. RESULTS: For asymptomatic volunteers, the DIR-UTE sequence showed significantly higher contrast-to-noise ratio values between the CEP and BMF (CNRCEP-BMF) (19.9 ± 3.0) and between the CEP and NP (CNRCEP-NP) (23.1 ± 1.7) compared to IR-FS-UTE (CNRCEP-BMF: 17.3 ± 1.2 and CNRCEP-NP: 19.1 ± 1.8), T1w-FS-UTE (CNRCEP-BMF: 9.0 ± 2.7 and CNRCEP-NP: 10.4 ± 3.5), and FS-UTE (CNRCEP-BMF: 7.7 ± 2.2 and CNRCEP-NP: 5.8 ± 2.4) for asymptomatic volunteers (all P-values < 0.001). For the spine sample and patients with low back pain, the DIR-UTE technique detected abnormalities such as irregularities and focal defects in the CEP regions. CONCLUSION: The 3D DIR-UTE sequence is able to provide high-contrast volumetric CEP imaging for human spines on a clinical 3 T scanner.


Asunto(s)
Dolor de la Región Lumbar , Humanos , Huesos , Imagen por Resonancia Magnética/métodos , Cartílago , Fantasmas de Imagen , Imagenología Tridimensional/métodos
3.
Magn Reson Med ; 89(2): 774-786, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36226662

RESUMEN

PURPOSE: Standardized blood tests often lack adequate sensitivity and specificity to capture the gradual progression of renal injuries. We suggest a multiparametric molecular MRI approach as a noninvasive tool for monitoring renal function loss and distinguishing different types of renal injuries. METHODS: CEST and quantitative magnetization transfer (qMT) imaging were performed on cisplatin (n = 16) and aristolochic acid (AA)-induced nephropathy (n = 22) mouse models at 7T with an infusion of either saline or urea. Seven-pool Lorentzian fitting was applied for the analysis of CEST Z-spectra, and the T1 -corrected CEST contrast apparent exchange-dependent relaxation (AREX) from urea (+1 ppm) and two nuclear Overhauser enhancement (NOE) pools (-1.6 and -3.5 ppm) were measured. Similarly, qMT spectra were fitted into two-pool Ramani equation and the relative semi-solid macromolecular pool-size ratio was measured. Histology of mouse kidneys was performed to validate the MR findings. RESULTS: AA model showed disrupted spatial gradients of urea in the kidney and significantly decreased NOE CEST and qMT contrast. The cisplatin model showed slightly decreased qMT contrast only. The orrelation of MR parameters to histological features showed that NOE CEST and qMT imaging are sensitive to both acute and chronic injuries, whereas urea CEST shows a significant correlation only to acute injuries. CONCLUSION: These results indicate that our multiparametric approach allows comprehensive and totally noninvasive monitoring of renal function and histological changes for distinguishing different nephropathies.


Asunto(s)
Cisplatino , Urea , Animales , Ratones , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Riñón/diagnóstico por imagen
4.
Magn Reson Med ; 85(5): 2791-2804, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33180343

RESUMEN

PURPOSE: We demonstrate a method of delayed urea differential enhancement CEST for probing urea recycling action of the kidney using expanded multi-pool Lorentzian fitting and apparent exchange-dependent relaxation compensation. METHODS: T1 correction of urea CEST contrast by apparent exchange-dependent relaxation was tested in phantoms. Nine mice were scanned at 7 Tesla following intraperitoneal injection of 2M 150 µL urea, and later saline. T1 maps and Z-spectra were acquired before and 20 and 40 min postinjection. Z-spectra were fit to a 7-pool Lorentzian model for CEST quantification and compared to urea assay of kidney homogenate. Renal injury was induced by aristolochic acid in 7 mice, and the same scan protocol was performed. RESULTS: Apparent exchange-dependent relaxation corrected for variable T1 times in phantoms. Urea CEST contrast at +1 ppm increased significantly at both time points following urea injection in the inner medulla and papilla. When normalizing the postinjection urea CEST contrast to the corresponding baseline value, both urea and saline injection resulted in identical fold changes in urea CEST contrast. Urea assay of kidney homogenate showed a significant correlation to both apparent exchange-dependent relaxation (R2 = 0.4687, P = .0017) and non-T1 -corrected Lorentzian amplitudes (R2 = 0.4964, P = .0011). Renal injury resulted in increased T1 time in the cortex and reduced CEST contrast change upon urea and saline infusion. CONCLUSION: Delayed urea enhancement following infusion can provide insight into renal urea handling. In addition, changes in CEST contrast at 1.0 ppm following saline infusion may provide insight into renal function.


Asunto(s)
Imagen por Resonancia Magnética , Urea , Animales , Riñón/diagnóstico por imagen , Ratones , Fantasmas de Imagen
5.
Magn Reson Med ; 83(3): 1034-1044, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31483529

RESUMEN

PURPOSE: Renal function is characterized by concentration of urea for removal in urine. We tested urea as a CEST-MRI contrast agent for measurement of the concentrating capacity of distinct renal anatomical regions. METHODS: The CEST contrast of urea was examined using phantoms with different concentrations and pH levels. Ten C57BL/6J mice were scanned twice at 7 T, once following intraperitoneal injection of 2M 150 µL urea and separately following an identical volume of saline. Kidneys were segmented into regions encompassing the cortex, outer medulla, and inner medulla and papilla to monitor spatially varying urea concentration. Z-spectra were acquired before and 20 minutes after injection, with dynamic scanning of urea handling performed in between via serial acquisition of CEST images acquired following saturation at +1 ppm. RESULTS: Phantom experiments revealed concentration and pH-dependent CEST contrast of urea that was both acid- and base-catalyzed. Z-spectra acquired before injection showed significantly higher CEST contrast in the inner medulla and papilla (2.3% ± 1.9%) compared with the cortex (0.15% ± 0.75%, P = .011) and outer medulla (0.12% ± 0.58%, P = .008). Urea infusion increased CEST contrast in the inner medulla and papilla by 2.1% ± 1.9% (absolute), whereas saline infusion decreased CEST contrast by -0.5% ± 2.0% (absolute, P = .028 versus urea). Dynamic scanning revealed that thermal drift and diuretic status are confounding factors. CONCLUSION: Urea CEST has a potential of monitoring renal function by capturing the spatially varying urea concentrating ability of the kidneys.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética , Urea/análisis , Algoritmos , Animales , Medios de Contraste/química , Femenino , Humanos , Concentración de Iones de Hidrógeno , Interpretación de Imagen Asistida por Computador/métodos , Corteza Renal , Pruebas de Función Renal , Masculino , Ratones , Ratones Endogámicos C57BL , Distribución Normal , Fantasmas de Imagen , Reproducibilidad de los Resultados , Urea/química , Urea/farmacología
6.
Bioconjug Chem ; 30(10): 2502-2518, 2019 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-31536323

RESUMEN

Unlike conventional 1H magnetic resonance imaging (MRI), 19F MRI features unambiguous detection of fluorine spins due to negligible background signals. Therefore, it is considered a promising noninvasive and selective imaging method for the diagnosis of cancers and other diseases. For 19F MRI, fluorine-rich molecules such as perfluorocarbons (PFC) have been formulated into nanoemulsions and used as its tracer agent. Along with advancements in other types of nanoparticles as targeted theranostics and stimuli-triggered probes and combined with the advantages of 19F MRI, PFC nanoemulsions are being empowered with these additional functionalities and becoming a promising theranostic platform. In this Review, we provide an overview of fluorine-based materials for sensitive 19F MRI of biological and pathological conditions. In particular, we describe designs and applications of recently reported stimuli-responsive and theranostic 19F MRI probes. Finally, challenges and future perspectives regarding the further development of 19F MRI probes for their clinical applications are described.


Asunto(s)
Imagen por Resonancia Magnética con Fluor-19/métodos , Sondas Moleculares/uso terapéutico , Animales , Flúor/química , Flúor/uso terapéutico , Humanos , Sondas Moleculares/química
7.
Radiology ; 287(2): 476-484, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29369752

RESUMEN

Purpose To investigate whether high-intensity focused ultrasound (HIFU)-induced macrophage infiltration could be longitudinally monitored with fluorine 19 (19F) magnetic resonance (MR) imaging in a quantitative manner. Materials and Methods BALB/c mice were subcutaneously inoculated with 4T1 cells and were separated into three groups: untreated mice (control, n = 9), HIFU-treated mice (HIFU, n = 9), and HIFU- and clodronate-treated mice (HIFU+Clod, n = 9). Immediately after HIFU treatment, all mice were intravenously given perfluorocarbon (PFC) emulsion. MR imaging examinations were performed 2, 4, 7, 10, and 14 days after HIFU treatment. Two-way repeated measures analysis of variance was used to analyze the changes in 19F signal over time and differences between groups. Histologic examinations were performed to confirm in vivo data. Results Fluorine 19 signals were detected at the rims of tumors and the peripheries of ablated lesions. Mean 19F signal in tumors was significantly higher in HIFU-treated mice than in control mice up to day 4 (0.82 ± 0.26 vs 0.42 ± 0.17, P < .001). Fluorine 19 signals were higher in the HIFU+Clod group than in the control group from day 4 (0.82 ± 0.23, P < .001) to day 14 (0.55 ± 0.16 vs 0.28 ± 0.06, P < .05). Histologic examination revealed macrophage infiltration around ablated lesions. Immunofluorescence staining confirmed PFC labeling of macrophages. Conclusion Fluorine 19 MR imaging can longitudinally capture and quantify HIFU-induced macrophage infiltration in preclinical tumor models. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Línea Celular Tumoral/efectos de los fármacos , Flúor/farmacocinética , Ultrasonido Enfocado de Alta Intensidad de Ablación , Inflamación/patología , Macrófagos/efectos de los fármacos , Neoplasias Experimentales/patología , Animales , Supervivencia Celular , Modelos Animales de Enfermedad , Técnica del Anticuerpo Fluorescente , Inflamación/diagnóstico por imagen , Ratones , Ratones Endogámicos BALB C , Neoplasias Experimentales/diagnóstico por imagen
8.
Radiology ; 282(1): 194-201, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27440581

RESUMEN

Purpose To investigate whether the magnitude of in vivo fluorine 19 (19F) magnetic resonance (MR) imaging signal is associated with subsequent development of colitis-associated dysplasia after in situ fluorination of inflammatory macrophages in a mouse model of inflammatory bowel disease (IBD). Materials and Methods Experiments were approved by the institutional animal care and use committee. Mice in the experimental group (n = 10) were administered azoxymethane and dextran sulfate sodium to induce colitis-associated dysplasia. Five mice were in the noninduced control group. Animals were injected with a commercially available perfluorocarbon and were examined in vivo with an 11.7-T MR imager for up to 110 days. Colons were then harvested followed by high-spatial-resolution ex vivo MR imaging. Multiple colon segments with or without 19F signal were histologically graded and were correlated with 19F signal intensity by using a Spearman correlation test. The signal intensity in mice with colitis-associated dysplasia was compared with that in control mice with a two-tailed Mann-Whitney U test. Results Patchy distributions of 19F signal intensity in the colon wall were seen on in vivo and ex vivo images, representing chronic inflammation as shown by immunohistochemistry. Histologic scores of inflammation and site-specific development of colitis-associated dysplasia in the descending colon showed good correlation with normalized 19F signal intensity (r = 0.88, P = .033 for the ascending colon; r = 0.82, P = .006 for the descending colon). A significantly (P = .002) higher normalized 19F signal-to-noise ratio was found at sites that developed dysplasia (mean, 0.58 ± 0.09 [standard deviation]) as compared with sites that did not (mean, 0.17 ± 0.22). Conclusion 19F MR imaging cell tracking of macrophages can be used to assess local inflammation in a mouse model of IBD. The resulting local 19F signal intensity, representing the magnitude of inflammation, has a positive correlation with the development of colitis-associated dysplasia. © RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Rastreo Celular/métodos , Colitis/diagnóstico por imagen , Macrófagos/patología , Imagen por Resonancia Magnética/métodos , Animales , Colitis/patología , Modelos Animales de Enfermedad , Femenino , Radioisótopos de Flúor , Procesamiento de Imagen Asistido por Computador , Ratones , Relación Señal-Ruido
9.
Quant Imaging Med Surg ; 14(2): 1673-1685, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38415151

RESUMEN

Background: Myelin water imaging (MWI) is a myelin-specific technique, which has great potential for the assessment of demyelination and remyelination. This study develops a new MWI method, which employs a short repetition time adiabatic inversion recovery (STAIR) technique in combination with a commonly used fast spin echo (FSE) sequence and provides quantification of myelin water (MW) fractions. Method: Whole-brain MWI was performed using the short repetition time adiabatic inversion recovery prepared-fast spin echo (STAIR-FSE) technique on eight healthy volunteers (mean age: 38±14 years, four-males) and seven patients with multiple sclerosis (MS) (mean age: 53.7±8.7 years, two-males) on a 3T clinical magnetic resonance imaging scanner. To facilitate the quantification of apparent myelin water fraction (aMWF), a proton density-weighted FSE was also used during the scans to allow total water imaging. The aMWF measurements of MS lesions and normal-appearing white matter (NAWM) regions in MS patients were compared with those measured in normal white matter (NWM) regions in healthy volunteers. Both the analysis of variance (ANOVA) test and paired comparison were performed for the comparison. Results: The MW in the whole-brain was selectively imaged and quantified using the STAIR-FSE technique in all participants. MS lesions showed much lower signal intensities than NAWM in the STAIR-FSE images. ANOVA analysis revealed a significant difference in the aMWF measurements between the three groups. Moreover, the aMWF measurements in MS lesions were significantly lower than those in both NWM of healthy volunteers and NAWM of MS patients. Lower aMWF measurements in NAWM were also found in comparison with those in NWM. Conclusions: The STAIR-FSE technique is capable of measuring aMWF values for the indirect detection of myelin loss in MS, thus facilitating clinical translation of whole brain MWI and quantification, which show great potential for the detection and evaluation of changes in myelin in the brain of patients with MS for future larger cohort studies.

10.
Front Physiol ; 15: 1394189, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38860112

RESUMEN

Introduction: Many spine disorders are caused by disc degeneration or endplate defects. Because nutrients entering the avascular disc are channeled through the cartilaginous endplate (CEP), structural and compositional changes in the CEP may block this solute channel, thereby hindering disc cell function. Therefore, imaging the CEP region is important to improve the diagnostic accuracy of spine disorders. Methods: A clinically available T1-weighted and fat-suppressed spoiled gradient recalled-echo (FS-SPGR) sequence was optimized for high-contrast CEP imaging, which utilizes the short T1 property of the CEP. The FS-SPGR scans with and without breath-hold were performed for comparison on healthy subjects. Then, the FS-SPGR sequence which produced optimal image quality was employed for patient scans. In this study, seven asymptomatic volunteers and eight patients with lower back pain were recruited and scanned on a 3T whole-body MRI scanner. Clinical T2-weighted fast spin-echo (T2w-FSE) and T1-weighted FSE (T1w-FSE) sequences were also scanned for comparison. Results: For the asymptomatic volunteers, the FS-SPGR scans under free breathing conditions with NEX = 4 showed much higher contrast-to-noise ratio values between the CEP and bone marrow fat (BMF) (CNRCEP-BMF) (i.e., 7.8 ± 1.6) and between the CEP and nucleus pulposus (NP) (CNRCEP-NP) (i.e., 6.1 ± 1.2) compared to free breathing with NEX = 1 (CNRCEP-BMF: 4.0 ± 1.1 and CNRCEP-NP: 2.5 ± 0.9) and breath-hold condition with NEX = 1 (CNRCEP-BMF: 4.2 ± 1.3 and CNRCEP-NP: 2.8 ± 1.3). The CEP regions showed bright linear signals with high contrast in the T1-weighted FS-SPGR images in the controls, while irregularities of the CEP were found in the patients. Discussion: We have developed a T1-weighted 3D FS-SPGR sequence to image the CEP that is readily translatable to clinical settings. The proposed sequence can be used to highlight the CEP region and shows promise for the detection of intervertebral disc abnormalities.

11.
Bioengineering (Basel) ; 11(1)2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38247943

RESUMEN

Introduction: The objective of this study was to assess the bi-exponential relaxation times and fractions of the short and long components of the human patellar tendon ex vivo using three-dimensional ultrashort echo time T1ρ (3D UTE-T1ρ) imaging. Materials and Methods: Five cadaveric human knee specimens were scanned using a 3D UTE-T1ρ imaging sequence on a 3T MR scanner. A series of 3D UTE-T1ρ images were acquired and fitted using single-component and bi-component models. Single-component exponential fitting was performed to measure the UTE-T1ρ value of the patellar tendon. Bi-component analysis was performed to measure the short and long UTE-T1ρ values and fractions. Results: The single-component analysis showed a mean single-component UTE-T1ρ value of 8.4 ± 1.7 ms for the five knee patellar tendon samples. Improved fitting was achieved with bi-component analysis, which showed a mean short UTE-T1ρ value of 5.5 ± 0.8 ms with a fraction of 77.6 ± 4.8%, and a mean long UTE-T1ρ value of 27.4 ± 3.8 ms with a fraction of 22.4 ± 4.8%. Conclusion: The 3D UTE-T1ρ sequence can detect the single- and bi-exponential decay in the patellar tendon. Bi-component fitting was superior to single-component fitting.

12.
Bone ; 184: 117096, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38631596

RESUMEN

High-resolution magnetic resonance imaging (HR-MRI) has been increasingly used to assess the trabecular bone structure. High susceptibility at the marrow/bone interface may significantly reduce the marrow's apparent transverse relaxation time (T2*), overestimating trabecular bone thickness. Ultrashort echo time MRI (UTE-MRI) can minimize the signal loss caused by susceptibility-induced T2* shortening. However, UTE-MRI is sensitive to chemical shift artifacts, which manifest as spatial blurring and ringing artifacts partially due to non-Cartesian sampling. In this study, we proposed UTE-MRI at the resonance frequency of fat to minimize marrow-related chemical shift artifacts and the overestimation of trabecular thickness. Cubes of trabecular bone from six donors (75 ± 4 years old) were scanned using a 3 T clinical scanner at the resonance frequencies of fat and water, respectively, using 3D UTE sequences with five TEs (0.032, 1.1, 2.2, 3.3, and 4.4 ms) and a clinical 3D gradient echo (GRE) sequence at 0.2 × 0.2 × 0.4 mm3 voxel size. Trabecular bone thickness was measured in 30 regions of interest (ROIs) per sample. MRI results were compared with thicknesses obtained from micro-computed tomography (µCT) at 50 µm3 voxel size. Linear regression models were used to calculate the coefficient of determination between MRI- and µCT-based trabecular thickness. All MRI-based trabecular thicknesses showed significant correlations with µCT measurements. The correlations were higher (examined with paired Student's t-test, P < 0.01) for 3D UTE images performed at the fat frequency (R2 = 0.59-0.74, P < 0.01) than those at the water frequency (R2 = 0.18-0.52, P < 0.01) and clinical GRE images (R2 = 0.39-0.47, P < 0.01). Significantly reduced correlations were observed with longer TEs. This study highlighted the feasibility of UTE-MRI at the fat frequency for a more accurate assessment of trabecular bone thickness.


Asunto(s)
Hueso Esponjoso , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Hueso Esponjoso/diagnóstico por imagen , Anciano , Masculino , Femenino , Tejido Adiposo/diagnóstico por imagen
13.
Front Radiol ; 3: 1263491, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37840897

RESUMEN

Introduction: Numerous techniques for myelin water imaging (MWI) have been devised to specifically assess alterations in myelin. The biomarker employed to measure changes in myelin content is known as the myelin water fraction (MWF). The short TR adiabatic inversion recovery (STAIR) sequence has recently been identified as a highly effective method for calculating MWF. The purpose of this study is to develop a new clinical transitional myelin water imaging (MWI) technique that combines STAIR preparation and echo-planar imaging (EPI) (STAIR-EPI) sequence for data acquisition. Methods: Myelin water (MW) in the brain has shorter T1 and T2 relaxation times than intracellular and extracellular water. In the proposed STAIR-EPI sequence, a short TR (e.g., ≤300 ms) together with an optimized inversion time enable robust long T1 water suppression with a wide range of T1 values [i.e., (600, 2,000) ms]. The EPI allows fast data acquisition of the remaining MW signals. Seven healthy volunteers and seven patients with multiple sclerosis (MS) were recruited and scanned in this study. The apparent myelin water fraction (aMWF), defined as the signal ratio of MW to total water, was measured in the lesions and normal-appearing white matter (NAWM) in MS patients and compared with those measured in the normal white matter (NWM) in healthy volunteers. Results: As seen in the STAIR-EPI images acquired from MS patients, the MS lesions show lower signal intensities than NAWM do. The aMWF measurements for both MS lesions (3.6 ± 1.3%) and NAWM (8.6 ± 1.2%) in MS patients are significantly lower than NWM (10 ± 1.3%) in healthy volunteers (P < 0.001). Discussion: The proposed STAIR-EPI technique, which can be implemented in MRI scanners from all vendors, is able to detect myelin loss in both MS lesions and NAWM in MS patients.

14.
Phys Med Biol ; 66(14)2021 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-34167100

RESUMEN

Cardiac chemical exchange saturation transfer-magnetic resonance imaging (CEST-MRI) has been used to probe levels of various metabolites that provide insight into myocardial structure and function. However, imaging of the heart using CEST-MRI is prolonged by the need to repeatedly acquire multiple images for a full Z-spectrum and to perform saturation and acquisition around cardiac and respiratory cycles. Compressed sensing (CS) reconstruction of sparse data enables accelerated acquisition, but reconstruction artifacts may bias subsequently derived measures of CEST contrast. In this study, we examine the impact of CS reconstruction of increasingly under-sampled cardiac CEST-MRI data on subsequent CEST contrasts of amine-containing metabolites and amide-containing proteins. Cardiac CEST-MRI data sets were acquired in six mice using low and high RF saturation for single and dual contrast generation, respectively. CEST-weighted images were reconstructed using CS methods at 2-5× levels of under-sampling. CEST contrasts were derived from corresponding Z-spectra and the impact of accelerated imaging on accuracy was assessed via analysis of variance. CS reconstruction preserved myocardial signal to noise ratio as compared to conventional reconstruction. However, greater absolute error and distribution of derived contrasts was observed with increasing acceleration factors. The results from this study indicate that acquisition of radial cardiac CEST-MRI data can be modestly, but meaningfully, accelerated via CS reconstructions with little error in CEST contrast quantification.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador , Animales , Artefactos , Imagen por Resonancia Magnética , Ratones , Fantasmas de Imagen , Relación Señal-Ruido
15.
Theranostics ; 7(3): 562-572, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28255351

RESUMEN

Perfluorocarbon nanoemulsions (PFCNEs) have recently been undergoing rigorous study to investigate their ability to improve the therapeutic efficacy of tumor ablation by high intensity focused ultrasound (HIFU). For precise control of PFCNE delivery and thermal ablation, their accumulation and distribution in a tumor should be quantitatively analyzed. Here, we used fluorine-19 (19F) magnetic resonance imaging (MRI) to quantitatively track PFCNE accumulation in a tumor, and analyzed how intra-tumoral PFCNE quantities affect the therapeutic efficacy of HIFU treatment. Ablation outcomes were assessed by intra-voxel incoherent motion analysis and bioluminescent imaging up to 14 days after the procedure. Assessment of PFCNE delivery and treatment outcomes showed that 2-3 mg/mL of PFCNE in a tumor produces the largest ablation volume under the same HIFU insonation conditions. Histology showed varying degrees of necrosis depending on the amount of PFCNE delivered. 19F MRI promises to be a valuable platform for precisely guiding PFCNE-enhanced HIFU ablation of tumors.


Asunto(s)
Técnicas de Ablación/métodos , Carcinoma/diagnóstico por imagen , Carcinoma/terapia , Imagen por Resonancia Magnética con Fluor-19/métodos , Fluorocarburos/administración & dosificación , Hipertermia Inducida/métodos , Sonicación/métodos , Animales , Carcinoma/patología , Modelos Animales de Enfermedad , Emulsiones/administración & dosificación , Histocitoquímica , Ratones Endogámicos BALB C , Ratones Desnudos , Trasplante Heterólogo , Resultado del Tratamiento
16.
Contrast Media Mol Imaging ; 2017: 4896310, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29362559

RESUMEN

The presence of tumor-associated macrophages (TAMs) is significantly associated with poor prognosis of tumors. Currently, magnetic resonance imaging- (MRI-) based TAM imaging methods that use nanoparticles such as superparamagnetic iron oxide and perfluorocarbon nanoemulsions are available for quantitative monitoring of TAM burden in tumors. However, whether MRI-based measurements of TAMs can be used as prognostic markers has not been evaluated yet. In this study, we used positron emission tomography (PET) with 18F-2-fluoro-2-deoxy-D-glucose (18F-FDG) as a radioactive tracer and fluorine-19- (19F-) MRI for imaging mouse breast cancer models to determine any association between TAM infiltration and tumor metabolism. Perfluorocarbon nanoemulsions were intravenously administered to track and quantify TAM infiltration using a 7T MR scanner. To analyze glucose uptake in tumors, 18F-FDG-PET images were acquired immediately after 19F-MRI. Coregistered 18F-FDG-PET and 19F-MR images enabled comparison of spatial patterns of glucose uptake and TAM distribution in tumors. 19F-MR signal intensities from tumors exhibited a strong inverse correlation with 18F-FDG uptake while having a significant positive correlation with tumor growth from days 2 to 7. These results show that combination of 19F-MRI and 18F-FDG-PET can improve our understanding of the relationship between TAM and tumor microenvironment.


Asunto(s)
Imagen por Resonancia Magnética con Fluor-19/métodos , Flúor/farmacología , Fluorodesoxiglucosa F18/farmacología , Macrófagos/metabolismo , Neoplasias Mamarias Experimentales , Tomografía de Emisión de Positrones/métodos , Microambiente Tumoral , Animales , Femenino , Macrófagos/patología , Neoplasias Mamarias Experimentales/diagnóstico por imagen , Neoplasias Mamarias Experimentales/metabolismo , Ratones
17.
Lab Chip ; 12(1): 159-66, 2012 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-22076418

RESUMEN

Embryonic stem cells (ESCs) have attracted great interest in the fields of tissue engineering, regenerative medicine, and organogenesis for their pluripotency and ability to self-renew. ESC aggregation, which produces an embryoid body (EB), has been widely utilized as a trigger of in vitro directed differentiation. In this paper, we propose a novel method for constructing large numbers of deep concave wells in PDMS microfluidic chips using the meniscus induced by the surface tension of a liquid PDMS prepolymer, and applied this chip for the mass production of uniform sized EBs. To investigate if the microenvironment in the deep concave well is suitable for ES cells, the oxygen diffusion to the deep concave well was analyzed by CFD simulation. Murine EBs were successfully formed in the deep concave wells without loss of cells and laborious careful intervention to refresh culture media. The size of the EBs was uniform, and retrieving of EBs was done just by flipping over the chip. All the processes including EB formation and harvest are easy and safe to cells, and their viability after completion of all processes was over 95%. The basic properties of the EBs were generated and their capacity to differentiate into 3 germ layers was investigated by analyzing the gene expression profile. The harvested EBs were found to differentiate into cardiac cells and neurons, and neurofilaments formed branches of elongated extensions more than 1.0 mm in length.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Cuerpos Embrioides/fisiología , Técnicas Analíticas Microfluídicas/instrumentación , Ingeniería de Tejidos/instrumentación , Ingeniería de Tejidos/métodos , Animales , Diferenciación Celular , Línea Celular , Supervivencia Celular , Simulación por Computador , Difusión , Dimetilpolisiloxanos/química , Cuerpos Embrioides/citología , Ratones , Mioblastos Cardíacos/citología , Células Neuroepiteliales/citología , Oxígeno/química , Tensión Superficial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA