Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38803029

RESUMEN

INTRODUCTION: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long-term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter. METHODS: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long-term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24-h Holter ECGs at 3, 6, and 12 months postablation; and 12-lead ECGs recorded during symptomatic episodes or visits. RESULTS: Half of the patients had ls-PerAF, and half had a history of catheter ablation-mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low-voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow-up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months. CONCLUSION: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.

2.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37335976

RESUMEN

AIMS: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Prospectivos , Adhesiones Focales , Resultado del Tratamiento , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
3.
Curr Opin Cardiol ; 36(1): 5-9, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33264171

RESUMEN

PURPOSE OF REVIEW: Pulsed field ablation is a nonthermal ablative modality that uses short living, strong electrical field created around catheter to create microscopic pores in cell membranes (electroporation). When adequately dosed/configured it shows a preference for myocardial tissue necrosis. Thus, it holds a promise to become a 'perfect' energy source for cardiac ablation to treat arrhythmias. Herein, we present update on platforms in clinical development. RECENT FINDINGS: First in human series using pulsed field ablation for atrial fibrillation ablation have been completed and data published for several platforms. Acute safety outcomes are similar across the platforms with exceptionally low rate of those complications that are typically reported for thermal ablation methods (esophageal injury, pulmonary vein stenosis, phrenic nerve palsy). Promising acute data on pulmonary vein isolation had been corroborated with satisfactory 1-year clinical follow-up for a single platform, whereas reports are pending for the rest. Research efforts are being expanded to a development of focal catheters, and therefore, pulsed field ablation application for ventricular arrhythmias. SUMMARY: As the reports confirming its safety and efficacy build up, there seems to be no way that the promise of pulsed field ablation could end in a blind alley.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Electroporación , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
4.
Heart Rhythm ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38499129

RESUMEN

BACKGROUND: Ablation of accessory pathways (APs) is the cornerstone for treatment of patients with Wolff-Parkinson-White syndrome and manifestation of atrioventricular reentrant tachycardia. Pulsed field ablation (PFA) is a new type of nonthermal energy source delivered to the underlying tissue via the ablation catheter and used for ablation of arrhythmic substrates. OBJECTIVE: The purpose of this study was to determine the efficiency and long-term outcome of ablation of APs of different localizations using a focal pulsed electrical field. METHODS: Electrophysiological study was performed in patients with indication for AP ablation. An ablation catheter was used to map the position of AP insertion. Pulsed electric field was delivered through a standard ablation catheter. In left-sided APs, the first ablation attempt was within the coronary sinus (CS). Patient follow-up was scheduled 1-3 months after the ablation. Additional check-up was performed after 6 and 12 months. RESULTS: Fourteen 14 patients (3 pediatric) were treated. Termination of AP conduction was achieved in all procedures. The cohort consisted of 3 right free wall, 3 posteroseptal, and 8 left-sided APs. Ablation through CS was successfully used in 7 of 8 patients with left-sided APs. No complications were reported. Median follow-up was 5.5 months. Conduction recurrence through AP was documented in 1 patient. CONCLUSION: Focal PFA for AP shows promising results in terms of efficacy and safety. A high rate of successful termination of left-sided APs by ablation within CS may represent a new standard approach. The safety and efficacy profile of PFA seems to be transferable to the pediatric population.

5.
JACC Clin Electrophysiol ; 7(5): 614-627, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33933412

RESUMEN

OBJECTIVES: This study sought to determine whether durable pulmonary vein isolation (PVI) using pulsed field ablation (PFA) translates to freedom from atrial fibrillation recurrence without an increase in adverse events. BACKGROUND: PFA is a nonthermal ablative modality that, in preclinical studies, is able to preferentially ablate myocardial tissue with minimal effect on surrounding tissues. Herein, we present 1-year clinical outcomes of PFA. METHODS: In 3 multicenter studies (IMPULSE [A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation], PEFCAT [A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation], and PEFCAT II [Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation]), paroxysmal atrial fibrillation patients underwent PVI using a basket or flower PFA catheter. Invasive remapping was performed at ∼2 to 3 months, and reconnected PVs were reisolated with PFA or radiofrequency ablation. After a 90-day blanking period, arrhythmia recurrence was assessed over 1-year follow-up. RESULTS: In 121 patients, acute PVI was achieved in 100% of PVs with PFA alone. PV remapping, performed in 110 patients at 93.0 ± 30.1 days, demonstrated durable PVI in 84.8% of PVs (64.5% of patients), and 96.0% of PVs (84.1% of patients) treated with the optimized biphasic energy PFA waveform. Primary adverse events occurred in 2.5% of patients (2 pericardial effusions or tamponade, 1 hematoma); in addition, there was 1 transient ischemic attack. The 1-year Kaplan-Meier estimates for freedom from any atrial arrhythmia for the entire cohort and for the optimized biphasic energy PFA waveform cohort were 78.5 ± 3.8% and 84.5 ± 5.4%, respectively. CONCLUSIONS: PVI with a "single-shot" PFA catheter results in excellent PVI durability and acceptable safety with a low 1-year rate of atrial arrhythmia recurrence. These data mitigate concern that the nonthermal ablative mechanism of PFA might mask undiscovered compromises to clinical success. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation, NCT03700385; A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation, NCT03714178; PEFCAT II Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation [PEFCAT II], NCT04170608).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Estudios de Factibilidad , Humanos , Venas Pulmonares/cirugía , Recurrencia
6.
J Am Coll Cardiol ; 76(9): 1068-1080, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32854842

RESUMEN

BACKGROUND: Unlike for paroxysmal atrial fibrillation (AF), pulmonary vein isolation (PVI) alone is considered insufficient for many patients with persistent AF. Adjunctive ablation of the left atrial posterior wall (LAPW) may improve outcomes, but is limited by both the difficulty of achieving lesion durability and concerns of damage to the esophagus-situated behind the LAPW. OBJECTIVES: This study sought to assess the safety and lesion durability of pulsed field ablation (PFA) for both PVI and LAPW ablation in persistent AF. METHODS: PersAFOne is a single-arm study evaluating biphasic, bipolar PFA using a multispline catheter for PVI and LAPW ablation under intracardiac echocardiographic guidance. A focal PFA catheter was used for cavotricuspid isthmus ablation. No esophageal protection strategy was used. Invasive remapping was mandated at 2 to 3 months to assess lesion durability. RESULTS: In 25 patients, acute PVI (96 of 96 pulmonary veins [PVs]; mean ablation time: 22 min; interquartile range [IQR]: 15 to 29 min) and LAPW ablation (24 of 24 patients; median ablation time: 10 min; IQR: 6 to 13 min) were 100% acutely successful with the multispline PFA catheter alone. Using the focal PFA catheter, acute cavotricuspid isthmus block was achieved in 13 of 13 patients (median: 9 min; IQR: 6 to 12 min). The median total procedure time was 125 min (IQR: 108 to 166 min) (including a median of 28 min [IQR: 25 to 33 min] for voltage mapping), with a median of 16 min (IQR: 12 to 23 min) fluoroscopy. Post-procedure esophagogastroduodenoscopy and repeat cardiac computed tomography revealed no mucosal lesions or PV narrowing, respectively. Invasive remapping demonstrated durable isolation (defined by entrance block) in 82 of 85 PVs (96%) and 21 of 21 LAPWs (100%) treated with the pentaspline catheter. In 3 patients, there was localized scar regression of the LAPW ablation, albeit without conduction breakthrough. CONCLUSIONS: The unique safety profile of PFA potentiated efficient, safe, and durable PVI and LAPW ablation. This extends the potential role of PFA beyond paroxysmal to persistent forms of AF. (Pulsed Fields for Persistent Atrial Fibrillation [PersAFOne]; NCT04170621).


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Anciano , Cateterismo Cardíaco/instrumentación , Ablación por Catéter/instrumentación , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA