Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Sci Rep ; 8(1): 2675, 2018 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-29422548

RESUMEN

We investigated host-derived biomarkers that were previously identified in QuantiFERON supernatants, in a large pan-African study. We recruited individuals presenting with symptoms of pulmonary TB at seven peripheral healthcare facilities in six African countries, prior to assessment for TB disease. We then evaluated the concentrations of 12 biomarkers in stored QuantiFERON supernatants using the Luminex platform. Based on laboratory, clinical and radiological findings and a pre-established algorithm, participants were classified as TB disease or other respiratory diseases(ORD). Of the 514 individuals included in the study, 179(34.8%) had TB disease, 274(51.5%) had ORD and 61(11.5%) had an uncertain diagnosis. A biosignature comprising unstimulated IFN-γ, MIP-1ß, TGF-α and antigen-specific levels of TGF-α and VEGF, identified on a training sample set (n = 311), validated by diagnosing TB disease in the test set (n = 134) with an AUC of 0.81(95% CI, 0.76-0.86), corresponding to a sensitivity of 64.2%(95% CI, 49.7-76.5%) and specificity of 82.7%(95% CI, 72.4-89.9%). Host biomarkers detected in QuantiFERON supernatants can contribute to the diagnosis of active TB disease amongst people presenting with symptoms requiring investigation for TB disease, regardless of HIV status or ethnicity in Africa.


Asunto(s)
Biomarcadores/sangre , Tuberculosis Pulmonar/diagnóstico , Adulto , África/epidemiología , Quimiocina CCL4/metabolismo , Citocinas/sangre , Femenino , Infecciones por VIH/complicaciones , Humanos , Interferón gamma/metabolismo , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Sensibilidad y Especificidad , Factor de Crecimiento Transformador alfa/metabolismo , Factor A de Crecimiento Endotelial Vascular/metabolismo
2.
Clin Biochem ; 49(1-2): 22-31, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26285074

RESUMEN

OBJECTIVE: Multi-center evaluation of a user-friendly lateral flow test for detection of IP-10 and CCL4 levels in Mycobacterium tuberculosis (Mtb) antigen-stimulated whole blood samples from tuberculosis (TB) suspects. DESIGN AND METHODS: A quantitative lateral flow (LF)-based assay platform was applied to detect chemokines IP-10 and CCL4. Chemokine quantitation was achieved using interference-free, fluorescent up-converting phosphor (UCP) labels. The new assays allowed worldwide shipping and storage without requiring a cold chain and were tested at seven institutes (including Ethiopia, Malawi, The Gambia, South Africa, Uganda and Namibia) employing portable lightweight readers for detection of the UCP label. At each site, clinical samples, confirmed TB and non-TB (i.e. other respiratory diseases (ORD)) cases, were collected and analyzed simultaneously with quality control (QC) human IP-10 or CCL4 standards. RESULTS: Performance of the UCP-LF assay in Africa using QC standards indicated high robustness allowing quantitative detection between 100 and 100,000pg/mL. The optimized assays allowed successful determination of chemokine levels using 1µL whole blood sample from the locally recruited subjects with TB or ORD. CONCLUSION: This African multi-center trial further demonstrated the applicability of the low-tech and robust UCP-LF platform as a convenient quantitative assay for chemokine detection in whole blood. Ambient shipping and storage of all assay reagents and the availability of lightweight standalone readers were acknowledged as essential requirement for test implementation in particular in remote and resource-limited settings.


Asunto(s)
Quimiocina CCL4/sangre , Quimiocina CXCL10/sangre , Tuberculosis/sangre , Estudios de Casos y Controles , Humanos
3.
J Infect ; 70(1): 11-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25043393

RESUMEN

OBJECTIVE: To assess mortality risk among adults presenting to an African teaching hospital with sepsis and severe sepsis in a setting of high HIV prevalence and widespread ART uptake. METHODS: Prospective cohort study of adults (age ≥16 years) admitted with clinical suspicion of severe infection between November 2008 and January 2009 to Queen Elizabeth Central Hospital, a 1250-bed government-funded hospital in Blantyre, Malawi. Demographic, clinical and laboratory information, including blood and cerebrospinal fluid cultures were obtained on admission. RESULTS: Data from 213 patients (181 with sepsis and 32 with severe sepsis; M:F = 2:3) were analysed. 161 (75.6%) patients were HIV-positive. Overall mortality was 22%, rising to 50% amongst patients with severe sepsis. The mortality of all sepsis patients commenced on antiretroviral therapy (ART) within 90 days was 11/28 (39.3%) compared with 7/42 (16.7%) among all sepsis patients on ART for greater than 90 days (p = 0.050). Independent associations with death were hypoxia (OR = 2.4; 95% CI, 1.1-5.1) and systolic hypotension (OR 7.0; 95% CI: 2.4-20.4). CONCLUSIONS: Sepsis and severe sepsis carry high mortality among hospitalised adults in Malawi. Measures to reduce this, including early identification and targeted intervention in high-risk patients, especially HIV-positive individuals recently commenced on ART, are urgently required.


Asunto(s)
Antirretrovirales/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Sepsis/mortalidad , Adulto , Antibacterianos/administración & dosificación , Bacteriemia , Ceftriaxona/administración & dosificación , Estudios de Cohortes , Femenino , Infecciones por VIH/complicaciones , Hospitalización , Hospitales Públicos , Humanos , Estudios Longitudinales , Malaui/epidemiología , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Sepsis/complicaciones , Sepsis/diagnóstico , Sepsis/tratamiento farmacológico , Adulto Joven
4.
BMJ ; 335(7612): 190, 2007 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-17638858

RESUMEN

OBJECTIVES: To assess the diagnostic accuracy and clinical utility of a simplified low cost method for measuring absolute and percentage CD4 counts with flow cytometry. DESIGN: A CD4 counting method (Blantyre count) using a CD4 and CD45 antibody combination with reduced blood and reagent volumes. Diagnostic accuracy was assessed by measuring agreement of the index test with two other assays (TruCount and FACSCount). Clinical utility was investigated by comparing CD4 counts with the new assay with WHO clinical staging in patients with HIV. SETTING: Research laboratories and antiretroviral therapy clinic at a medical school and large government hospital in southern Malawi. PARTICIPANTS: Assay comparisons were performed on consecutive blood samples sent for CD4 counting from 129 patients with HIV. Comparison of CD4 count with staging was conducted on 253 consecutive new patients attending the antiretroviral therapy clinic. MAIN OUTCOME MEASURES: Limits of agreement with 95% confidence intervals between index test and reference standards. RESULTS: The limits of agreement for Blantyre count and TruCount were excellent (cell count -48.9 to 27.0 x10(9)/l for absolute counts in the CD4 range <400x10(9)/l and -2.42% to 2.37% for CD4 percentage). The assay was affordable with reagent costs per test of $0.44 ( pound0.22, euro0.33) for both absolute count and CD4 percentage, and $0.11 for CD4 percentage alone. Of 193 patients with clinical stage I or II disease, who were ineligible for antiretroviral therapy by clinical staging criteria, 73 (38%) had CD4 counts <200x10(9)/l. By contrast, 12 (20%) of 60 patients with stage III or IV disease had CD4 counts >350x10(9)/l. CONCLUSIONS: This simplified method of counting CD4 cells with flow cytometry has good agreement with established commercial assays, is affordable for routine clinical use in Africa, and could improve clinical decision making in patients with HIV.


Asunto(s)
Linfocitos T CD4-Positivos , Infecciones por VIH/diagnóstico , Recuento de Linfocitos/normas , Adulto , Análisis Costo-Beneficio , Citometría de Flujo/economía , Citometría de Flujo/normas , Humanos , Recuento de Linfocitos/economía , Malaui , Control de Calidad , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA