Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Biol Chem ; 300(5): 107214, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38522521

RESUMEN

The role of polyunsaturated fatty acid (PUFA) biosynthesis in acute myeloid leukemia (AML) remains largely undefined. A comparative expression analysis of 35 genes encoding fatty acid biosynthesis enzymes showed that fatty acid desaturase 1 (FADS1) was highly expressed across multiple AML subtypes relative to healthy controls and that elevated FADS1 expression correlates with worse overall AML patient survival. Functionally, shRNA-mediated inhibition of FADS1 reduced AML cell growth in vitro and significantly delayed leukemia onset in an AML mouse model. AML cell lines depleted of FADS1 arrested in the G1/S-phase of the cell cycle, acquired characteristics of myeloid maturation and subsequently died. To understand the molecular consequences of FADS1 inhibition, a combination of mass spectrometry-based analysis of complex lipids and gene expression analysis (RNA-seq) was performed. FADS1 inhibition caused AML cells to exhibit significant lipidomic remodeling, including depletion of PUFAs from the phospholipids, phosphatidylserine, and phosphatidylethanolamine. These lipidomic alterations were accompanied by an increase induction of inflammatory and stimulator of interferon genes (STING)-mediated type-1 interferon signaling. Remarkably, genetic deletion of STING largely prevented the AML cell maturation and death phenotypes mediated by FADS1 inhibition. Highlighting the therapeutic implications of these findings, pharmacological blockade of PUFA biosynthesis reduced patient-derived AML cell numbers ex vivo but not that of healthy donor cells. Similarly, STING agonism attenuated patient-derived-AML survival; however, STING activation also reduced healthy granulocyte numbers. Collectively, these data unveil a previously unrecognized importance of PUFA biosynthesis in leukemogenesis and that imbalances in PUFA metabolism can drive STING-mediated AML maturation and death.


Asunto(s)
delta-5 Desaturasa de Ácido Graso , Ácido Graso Desaturasas , Ácidos Grasos Insaturados , Leucemia Mieloide Aguda , Proteínas de la Membrana , Leucemia Mieloide Aguda/metabolismo , Leucemia Mieloide Aguda/patología , Leucemia Mieloide Aguda/genética , Animales , Humanos , Ratones , Ácidos Grasos Insaturados/metabolismo , Ácidos Grasos Insaturados/biosíntesis , Ácido Graso Desaturasas/metabolismo , Ácido Graso Desaturasas/genética , Proteínas de la Membrana/metabolismo , Proteínas de la Membrana/genética , Línea Celular Tumoral , Muerte Celular , Transducción de Señal
2.
BMC Public Health ; 22(1): 1922, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-36243709

RESUMEN

OBJECTIVE: To evaluate the feasibility and performance of self-collected vaginal swab samples for HPV screening among women in Lagos, Nigeria. METHODS: A cross-sectional study was implemented from March to August 2020 among sexually active women. Study participants provided same-day paired vaginal swab samples. Medic-sampling and poster-directed self-sampling methods were used to collect the two samples per participant. A real-time PCR assay detected HPV 16, HPV 18, other-high-risk (OHR) HPV, and the human ß-globin gene. The self-collected samples' sensitivity, specificity, and accuracy were determined against the medic-collected samples using the MedCalc Online Diagnostic Calculator. RESULTS: Of the 213 women aged 16 ~ 63-year-old recruited, 187 (88%) participants had concordant results, while 26 (12%) participants had discordant results. Among the 187 concordant results, 35 (19%) were HPV positive, 150 (80%) participants were HPV negative, and two (1%) were invalid. 18 (69%) out of the 26 discordant samples were invalid. The self-collected sample was invalid for 14 (54%) participants. Two (8%) medic-collected samples were invalid. Compared to the medic-collected sample, the self-collected sample was 89.80% (95% CI: 77.77 ~ 96.60%) sensitive and 98.21% (95% CI: 94.87 ~ 99.63%) specific, with an accuracy of 96.31% (95% CI: 92.87 ~ 98.40%). The mean age for HPV positive and negative participants were 39 and 40, respectively, with an ANOVA p-value of 0.3932. The stratification of HPV infection by the age group was not statistically significant (P > 0.05). CONCLUSIONS: With high accuracy of 96%, self-collected sampling is adequate when tested with real-time PCR and may increase the uptake of HPV testing. Though more self-collected samples were invalid than medic-collected samples, most likely due to poor collection, they could be identified for repeat testing. Future implementation can avoid this error with improved guidance and awareness.


Asunto(s)
Alphapapillomavirus , Infecciones por Papillomavirus , Neoplasias del Cuello Uterino , Estudios Transversales , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Persona de Mediana Edad , Nigeria , Papillomaviridae/genética , Infecciones por Papillomavirus/diagnóstico , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Neoplasias del Cuello Uterino/diagnóstico , Frotis Vaginal/métodos , Globinas beta
3.
Front Oncol ; 13: 1254304, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37876969

RESUMEN

Introduction: Human Papillomavirus (HPV) infection is a risk factor for cervical cancer, the fourth most common cancer among women globally. Its burden is the highest in sub-Saharan Africa, with over 90% mortality. Interventions may fail without evidence-based data on stratified prevalence and risk factors among most at-risk women across Nigeria. Methods: A cross-sectional comparative study, with participants recruited from the Nigerian Institute of Medical Research's Clinics, NGO outreaches, a cancer screening centre and a university teaching hospital. Questionnaires were self-administered. Trained medics performed sampling at healthcare facilities, and self-sampling was used at outreaches. Results: Nine hundred eighty-five study participants were recruited. About 37% and 27% of the women knew about HPV and its vaccines, respectively, but only 6% confirmed vaccination with HPV vaccines. HPV prevalence was highest among women with unknown marital status (35.9%), single women (33.8%), widowed/divorced/separated women (30.3%), and married/cohabiting women (19.6%). HPV infection was significantly higher among women who take alcohol (odds=1.7 [95% CI: 1.2-2.4]) and women who smoke (odds=2.6 [95% CI: 1.4 - 4.6]. HPV strains detected included HPV16 (1.3%), HPV18 (1.5%), Low Risk (0.2%) and Other High-Risk groups (19.7%). Conclusion: The inverse relationship between prevalence and education suggests interventions improving awareness and prevention would be impactful. Such interventions could also target HIV-positive women, women presenting with sexually-transmitted infections, who smoke and frequently drink alcohol.

4.
Afr J Lab Med ; 11(1): 1677, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36337771

RESUMEN

Background: Previous studies in Nigeria have reported the presence of hepatitis B virus (HBV) genotype E and the availability of immune escape mutants. There is a paucity of data on chronic patients on long-term antiviral therapy for HBV infection. Objective: This study assessed HBV genotypes and drug resistance variants among patients with chronic HBV infection receiving tenofovir in Jos, Nigeria. Methods: This cross-sectional study consecutively enrolled 101 patients (51 with HIV/HBV co-infection and 50 with HBV infection only) on antiviral therapy from February 2018 to May 2019 at four hospitals in Jos, Nigeria. DNA quantification of HBV was performed on all samples; 30 samples with detectable viral load were selected for genotyping using Sanger sequencing by targeting the full-length sequences of reverse transcriptase gene of the HBV genome. Phylogenetic analysis was performed with reference sequences from GenBank. Escape mutant and drug resistance analysis were performed using HBV drug resistance interpretation and Geno2pheno. Results: Only 30 (29.7%) of the 101 study participants had detectable HBV DNA. Of these, six (20.0%) isolates were successfully amplified and sequenced. The identified genotype was E, including escape mutations L127R (16.7%) and G145A (16.7%). Conclusion: This study revealed exclusive dominance of genotype E in Nigeria. The S gene mutations G145A and L271R are known to be associated with modified antigenicity and impaired serologic assays, which may cause false negatives in the detection of anti-HBV surface antigen. The presence of mutants that are associated with vaccine immune escape may also have diagnostic and vaccine immune response implications.

5.
PLoS One ; 16(6): e0252611, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34111179

RESUMEN

The present global pandemic triggered by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has lingered for over a year in its devastating effects. Diagnosis of coronavirus disease 2019 (COVID-19) is currently established with a polymerase chain reaction (PCR) test by means of oropharyngeal-, nasopharyngeal-, anal-swabs, sputum and blood plasma. However, oral and nasal swabs are more commonly used. This study, therefore, assessed sensitivity and specificity of plasma as a diagnostic in comparison with a combination of oral and nasal swab samples, and the implications for blood transfusion. Oropharyngeal (OP) and nasopharyngeal (NP) swab samples were obtained from 125 individuals suspected to have COVID-19 and stored in viral transport medium (VTM) tubes. Ten millilitres of blood samples in EDTA were also obtained by venepuncture and spun to obtain plasma. Viral RNA was obtained from both swabs and plasma by manual extraction with Qiagen QIAamp viral RNA Mini Kit. Detection was done using a real time fluorescent RT-qPCR BGI kit, on a QuantStudio 3 real-time PCR instrument. Average age of study participants was 41 years, with 74 (59.2%) being male. Out of the 125 individuals tested for COVID-19, 75 (60%) were positive by OP/NP swab. However, only 6 (4.8%) had a positive plasma result for COVID-19 with median Ct value of 32.4. Sensitivity and specificity of RT-PCR SARS-CoV-2 test using plasma was 8% and 100% respectively. There was no false positive recorded, but 69 (55.2%) false negatives were obtained by plasma. SARS-CoV-2 viral RNA was detected, albeit low (4.8%) in plasma. Plasma is likely not a suitable biological sample to diagnose acute SARS-CoV-2 infection. The implication of transfusing blood in this era of COVID-19 needs further investigations.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , ARN Viral/análisis , SARS-CoV-2/aislamiento & purificación , Adolescente , Adulto , Anciano , COVID-19/sangre , COVID-19/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nigeria/epidemiología , ARN Viral/sangre , ARN Viral/genética , SARS-CoV-2/genética , Sensibilidad y Especificidad , Adulto Joven
6.
PLoS One ; 16(1): e0243271, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33428634

RESUMEN

In an outbreak, effective detection of the aetiological agent(s) involved using molecular techniques is key to efficient diagnosis, early prevention and management of the spread. However, sequencing is necessary for mutation monitoring and tracking of clusters of transmission, development of diagnostics and for vaccines and drug development. Many sequencing methods are fast evolving to reduce test turn-around-time and to increase through-put compared to Sanger sequencing method; however, Sanger sequencing remains the gold standard for clinical research sequencing with its 99.99% accuracy This study sought to generate sequence data of SARS-CoV-2 using Sanger sequencing method and to characterize them for possible site(s) of mutations. About 30 pairs of primers were designed, synthesized, and optimized using endpoint PCR to generate amplicons for the full length of the virus. Cycle sequencing using BigDye Terminator v.3.1 and capillary gel electrophoresis on ABI 3130xl genetic analyser were performed according to the manufacturers' instructions. The sequence data generated were assembled and analysed for variations using DNASTAR Lasergene 17 SeqMan Ultra. Total length of 29,760bp of SARS-CoV-2 was assembled from the sample analysed and deposited in GenBank with accession number: MT576584. Blast result of the sequence assembly shows a 99.97% identity with the reference sequence. Variations were noticed at positions: nt201, nt2997, nt14368, nt16535, nt20334, and nt28841-28843, which caused amino acid alterations at the S (aa614) and N (aa203-204) regions. The mutations observed at S and N-gene in this study may be indicative of a gradual changes in the genetic coding of the virus hence, the need for active surveillance of the viral genome.


Asunto(s)
COVID-19/virología , SARS-CoV-2/genética , Secuencia de Bases , COVID-19/epidemiología , Genoma Viral , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Nigeria/epidemiología , Filogenia , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
7.
PLoS One ; 16(2): e0246637, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33539485

RESUMEN

A key element in containing the spread of the SARS-CoV-2 infection is quality diagnostics which is affected by several factors. We now report the comparative performance of five real-time diagnostic assays. Nasopharyngeal swab samples were obtained from persons seeking a diagnosis for SARS-CoV-2 infection in Lagos, Nigeria. The comparison was performed on the same negative, low, and high-positive sample set, with viral RNA extracted using the Qiagen Viral RNA Kit. All five assays are one-step reverse transcriptase real-time PCR assays. Testing was done according to each assay's manufacturer instructions for use using real-time PCR platforms. 63 samples were tested using the five qPCR assays, comprising of 15 negative samples, 15 positive samples (Ct = 16-30; one Ct = 35), and 33 samples with Tib MolBiol E-gene Ct value ranging from 36-41. All assays detected all high positive samples correctly. Three assays correctly identified all negative samples while two assays each failed to correctly identify one different negative sample. The consistent detection of positive samples at different Ct/Cq values gives an indication of when to repeat testing and/or establish more stringent in-house cut-off value. The varied performance of different diagnostic assays, mostly with emergency use approvals, for a novel virus is expected. Comparative assays' performance reported may guide laboratories to determine both their repeat testing Ct/Cq range and/or cut-off value.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/epidemiología , COVID-19/virología , Humanos , Nigeria/epidemiología , ARN Viral/análisis , Estudios Retrospectivos , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
8.
J Biomol Tech ; 31(4): 157-164, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33100921

RESUMEN

Despite various challenges that hinder the implementation of high-tech molecular methods in resource-limited settings, we have been able to implement and achieve International Organization for Standardization 15189:2012 accreditation for genotypic HIV drug resistance testing in our facility. At the Center for Human Virology and Genomics, Nigerian Institute of Medical Research, Nigeria has recorded a high sequencing success rate and good quality sequence data. This was achieved by optimizing laboratory processes from 2008 to the current date. We have optimized sample preparation, RT-PCR, several post-PCR processes, and the cycle sequencing to improve the sensitivity of amplification even with limited plasma samples and low viral copy numbers. The optimized workflow maximizes output, minimizes reagent wastage, and achieves substantial cost savings without compromising the quality of the sequence data. Our performance at our last external quality assurance program is a testimonial to the efficiency of the workflow. For the 5-sample panel, each with 67-68 mutation points evaluated, we scored 100% for all 5 specimens. Our optimized laboratory workflow is thus documented to support laboratories and to help researchers achieve excellent results the first time and eliminate contamination while minimizing the wastage of costly sequencing reagents.


Asunto(s)
Farmacorresistencia Viral , Infecciones por VIH/diagnóstico , VIH-1/genética , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Análisis de Secuencia de ADN/métodos , Infecciones por VIH/virología , Humanos , Laboratorios , Nigeria , Control de Calidad , ARN Viral/aislamiento & purificación , Estándares de Referencia , Flujo de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA