1.
Eur J Heart Fail ; 26(6): 1383-1392, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38741283

RESUMEN

AIMS: We examined the effectiveness of a novel cardiopulmonary management wearable sensor (worn for less than 5 mins) at measuring congestion and correlated the device findings with established clinical measures of congestion. METHODS AND RESULTS: We enrolled three cohorts of patients: (1) patients with heart failure (HF) receiving intravenous diuretics in hospital; (2) patients established on haemodialysis, and (3) HF patients undergoing right heart catheterization (RHC). The primary outcomes in the respective cohorts were a Spearman correlation between (1) change in weight and change in thoracic impedance (TI) (from enrolment, 24 h after admission to discharge) in patients hospitalized for HF; (2) lung ultrasound B-lines and volume removed during dialysis with device measured TI, and (3) pulmonary capillary wedge pressure (PCWP) and sub-acoustic diastolic, third heart sound (S3) in the patients undergoing RHC. A total of 66 patients were enrolled. In HF patients (n = 25), change in weight was correlated with both change in device TI (Spearman correlation [rsp] = -0.64, p = 0.002) and change in device S3 (rsp = -0.53, p = 0.014). In the haemodialysis cohort (n = 21), B-lines and TI were strongly correlated before (rsp = -0.71, p < 0.001) and after (rsp = -0.77, p < 0.001) dialysis. Volume of fluid removed by dialysis was correlated with change in device TI (rsp = 0.49, p = 0.024). In the RHC cohort (n = 20), PCWP measured at one time point and device S3 were not significantly correlated (rsp = 0.230, p = 0.204). There were no device-related adverse events. CONCLUSIONS: A non-invasive device was able to detect changes in congestion in patients with HF receiving decongestion therapy and patients having fluid removed at haemodialysis. The cardiopulmonary management device, which measures multiple parameters, is a potentially useful tool to monitor patients with HF to prevent hospitalizations.


Asunto(s)
Insuficiencia Cardíaca , Diálisis Renal , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Masculino , Femenino , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Anciano , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Dispositivos Electrónicos Vestibles , Presión Esfenoidal Pulmonar/fisiología , Cateterismo Cardíaco/métodos
2.
Card Fail Rev ; 9: e10, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37427007

RESUMEN

Water and salt retention, in other words congestion, are fundamental to the pathophysiology of heart failure and are important therapeutic targets. Echocardiography is the key tool with which to assess cardiac structure and function in the initial diagnostic workup of patients with suspected heart failure and is essential for guiding treatment and stratifying risk. Ultrasound can also be used to identify and quantify congestion in the great veins, kidneys and lungs. More advanced imaging methods might further clarify the aetiology of heart failure and its consequences for the heart and periphery, thereby improving the efficiency and quality of care tailored with greater precision to individual patient need.

4.
Scand J Infect Dis ; 42(10): 791-3, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20482456

RESUMEN

Following the advent of antibiotics, pneumococcal pericarditis has become a rare clinical diagnosis. We discuss 2 cases of pneumococcal pericarditis that were preceded by community-acquired pneumonia. Cultures were negative in both patients and the diagnosis was made by antigen testing and polymerase chain reaction (PCR) of the pericardial fluid. PCR or antigen testing of pericardial fluid for pneumococci should be considered in patients with a typical history, particularly when culture-negative and with a history of prior antibiotics.


Asunto(s)
Antígenos Bacterianos/análisis , Pericarditis/diagnóstico , Infecciones Neumocócicas/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Streptococcus pneumoniae/genética , Streptococcus pneumoniae/aislamiento & purificación , Adulto , Infecciones Comunitarias Adquiridas/complicaciones , Infecciones Comunitarias Adquiridas/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Derrame Pericárdico/microbiología , Pericarditis/microbiología , Infecciones Neumocócicas/microbiología , Neumonía Neumocócica/complicaciones , Neumonía Neumocócica/microbiología , Streptococcus pneumoniae/clasificación , Streptococcus pneumoniae/inmunología , Adulto Joven
5.
Eur J Echocardiogr ; 11(2): 192-4, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19939816

RESUMEN

We report the case of a 76-year-old lady who had a mitral valve (MV) replacement for severe MV stenosis. Several days following the procedure, a routine transthoracic echocardiogram (TTE) was performed. Despite the prosthesis leaflets opening well anterograde maximum velocities were elevated; MV peak velocity of 2.4 m/s. A transoesophageal echocardiogram (TEE) demonstrated the superior strut of the prosthesis appearing to rotate inwards such that the ventricular (non-fixed) end of the struts approximate to one another during systole, reducing the effective orifice area for anterograde flow. A 3D TEE was performed. This showed that the valve struts were not parallel, with the planes of the struts converging from the base to the apex. However, this abnormal conformation appeared to be fixed rather than worsening in systole. The apparent movement of the posterior strut seen in the 2D TEE images appears to have resulted from systole movement of this strut partially out of the plane of the TEE (2D) cut. We believe the case demonstrates the value of 3D real-time TEE in the assessment of the MV prosthesis function.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Estenosis de la Válvula Mitral/cirugía
6.
Echo Res Pract ; 6(1): 7-15, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30550376

RESUMEN

Right ventricular (RV) dysfunction occurs following lung resection and is associated with post-operative complications and long-term functional morbidity. Accurate peri-operative assessment of RV function would have utility in this population. The difficulties of transthoracic echocardiographic (TTE) assessment of RV function may be compounded following lung resection surgery, and no parameters have been validated in this patient group. This study compares conventional TTE methods for assessing RV systolic function to a reference method in a lung resection population. Right ventricular index of myocardial performance (RIMP), fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE) and S' wave velocity at the tricuspid annulus (S'), along with speckle tracked global and free wall longitudinal strain (RV-GPLS and RV-FWPLS respectively) are compared with RV ejection fraction obtained by cardiovascular magnetic resonance (RVEFCMR). Twenty-seven patients undergoing lung resection underwent contemporaneous CMR and TTE imaging; pre-operatively, on post-operative day two and at 2 months. Ability of each of the parameters to predict RV dysfunction (RVEFCMR <45%) was assessed using the area under the receiver operating characteristic curve (AUROCC). RIMP, FAC and S' demonstrated no predictive value for poor RV function (AUROCC <0.61, P > 0.05). TAPSE performed marginally better with an AUROCC of 0.65 (P = 0.04). RV-GPLS and RV-FWPLS demonstrated good predictive ability with AUROCC's of 0.74 and 0.76 respectively (P < 0.01 for both). This study demonstrates that the conventional TTE parameters of RV systolic function are inadequate following lung resection. Longitudinal strain performs better and offers some ability to determine poor RV function in this challenging population.

7.
JACC Cardiovasc Imaging ; 12(1): 96-105, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29248646

RESUMEN

OBJECTIVES: The aim of this study was to establish sex differences in remodeling and outcome in aortic stenosis (AS) and their associations with biomarkers of myocardial fibrosis. BACKGROUND: The remodeling response and timing of symptoms is highly variable in AS, and sex plays an important role. METHODS: A total of 174 patients (133 men, mean age 66.2 ± 13.3 years) with asymptomatic moderate to severe AS underwent comprehensive stress cardiac magnetic resonance imaging, transthoracic echocardiography, and biomarker analysis (matrix metalloproteinase [MMP]-2, -3, -7, -8, and -9; tissue inhibitor matrix metalloproteinases-1 and -4; syndecan-1 and -4; and N-terminal pro-B-type natriuretic peptide), and were followed up at 6-month intervals. A primary endpoint was a composite of typical AS symptoms necessitating referral for aortic valve replacement, cardiovascular death, or major adverse cardiovascular events. RESULTS: For a similar severity of AS, male patients demonstrated higher indexed left ventricular (LV) volumes and mass, more concentric remodeling (higher LV mass/volume), a trend to more late gadolinium enhancement (present in 51.1% men vs. 34.1% women; p = 0.057), and higher extracellular volume index than female patients (13.27 [interquartile range (IQR): 11.5 to 17.0] vs. 11.53 [IQR: 10.5 to 13.5] ml/m2, p = 0.017), with worse systolic and diastolic function and higher MMP-3 and syndecan-4 levels, whereas female patients had higher septal E/e'. Male sex was independently associated with indexed LV mass (ß = 13.32 [IQR: 9.59 to 17.05]; p < 0.001). During median follow-up of 374 (IQR: 351 to 498) days, a primary outcome, driven by spontaneous symptom onset, occurred in 21.8% of male and 43.9% of female patients (relative risk: 0.50 [95% confidence interval: 0.31 to 0.80]; p = 0.004). Measures of AS severity were associated with the primary outcome in both sexes, whereas N-terminal pro-B-type natriuretic peptide, MMP-3, and mass/volume were only associated in men. CONCLUSIONS: In AS, women tolerate pressure overload with less concentric remodeling and myocardial fibrosis but are more likely to develop symptoms. This may be related to higher wall stress and filling pressures in women.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Disparidades en el Estado de Salud , Hipertrofia Ventricular Izquierda/etiología , Miocardio/patología , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda , Remodelación Ventricular , Adaptación Fisiológica , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Biomarcadores/sangre , Progresión de la Enfermedad , Ecocardiografía , Femenino , Fibrosis , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/patología , Hipertrofia Ventricular Izquierda/fisiopatología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología
8.
Eur J Heart Fail ; 20(9): 1338-1347, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29952090

RESUMEN

AIMS: We investigated which patients with heart failure (HF) should receive specialist palliative care (SPC) by first creating a definition of need for SPC in patients hospitalised with HF using patient-reported outcome measures (PROMs) and then testing this definition using the outcome of days alive and out of hospital (DAOH). We also evaluated which baseline variables predicted need for SPC and whether those with this need received SPC. METHODS AND RESULTS: PROMs assessing quality of life (QoL), symptoms, and mood were administered at baseline and every 4 months. SPC need was defined as persistently severe impairment of any PROM without improvement (or severe impairment immediately preceding death). We then tested whether need for SPC, so defined, was reflected in DAOH, a measure which combines length of stay, days of hospital re-admission, and days lost due to death. Of 272 patients recruited, 74 (27%) met the definition of SPC needs. These patients lived one third fewer DAOH than those without SPC need (and less than a quarter of QoL-adjusted DAOH). A Kansas City Cardiomyopathy Questionnaire (KCCQ) summary score of <29 identified patients who subsequently had SPC needs (area under receiver operating characteristic curve 0.78). Twenty-four per cent of patients with SPC needs actually received SPC (n = 18). CONCLUSIONS: A quarter of patients hospitalised with HF had a need for SPC and were identified by a low KCCQ score on admission. Those with SPC need spent many fewer DAOH and their DAOH were of significantly worse quality. Very few patients with SPC needs accessed SPC services.


Asunto(s)
Insuficiencia Cardíaca/terapia , Cuidados Paliativos/estadística & datos numéricos , Medición de Resultados Informados por el Paciente , Selección de Paciente , Calidad de Vida , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Cuidados Paliativos/métodos , Prevalencia , Estudios Retrospectivos , Especialización , Reino Unido/epidemiología
9.
Innovations (Phila) ; 11(2): 84-93, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26889881

RESUMEN

OBJECTIVE: This study aimed to evaluate a novel device system for surgical aortic valve replacement (SAVR) using a unique new less invasive access approach. The hypothesis is that SAVR can be performed through a short transverse incision in the neck, similar to that used for transcervical thymectomy avoiding chest disruption. METHODS: A new device system was developed to provide retraction, step-by-step illumination, and on-screen visualization for the new approach. Preliminary feasibility studies were performed in cadavers. Comprehensive risk analysis was performed, and training was implemented in Thiel preserved cadavers. For the first-in-man clinical case, a 63-year-old woman with symptomatic critical aortic stenosis (The Society of Thoracic Surgeons risk, 11%) and heavily calcified aortic valve was selected. A short transverse incision was made in the neck; the device was introduced, and the sternum was elevated; femorofemoral cardiopulmonary bypass was established; substernal dissection was guided by the sequenced illumination, and high-definition visualization was provided by the device, allowing for optimal exposition of the aorta and aortic valve; and a 23-mm Medtronic ENABLE sutureless valve prosthesis was implanted. Procedure success was evaluated according to the standardized composite end point definition of "device success" proposed by the Valve Academic Research Consortium. RESULTS: Access, delivery, and deployment of the valve prosthesis were successful. The correct position and intended performance of the valve were demonstrated (mean gradient, 6 mm Hg; aortic valve area, 2.5 cm) with the absence of moderate or severe prosthetic aortic regurgitation. Only one valve prosthesis was used. CONCLUSIONS: Transcervical SAVR with sutureless valve is feasible using this novel access system. The new approach has potential to offer patients substantially shorter stay and fewer, less serious complications, as has been observed in transcervical thymectomy. Further studies are merited.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Puente Cardiopulmonar/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Puente Cardiopulmonar/instrumentación , Femenino , Humanos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Cuello/cirugía , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
10.
Kardiol Pol ; 60(3): 247-9, 2004 Mar.
Artículo en Polaco | MEDLINE | ID: mdl-15156220

RESUMEN

We describe a case of a 55-year-old male with anterior myocardial infarction, treated in the acute phase with thrombolysis. Transthoracic echocardiography showed hypokinetic apical segments, ejection fraction of 55% and reduced coronary flow reserve in the left anterior descending (LAD) coronary artery. Elective coronary angiography revealed a borderline (40-50%) lesion in LAD. The patient underwent successful angioplasty of LAD with stent implantation. Non-invasive coronary flow reserve measurements were repeated 3 days, 6 weeks and 6 months after angioplasty showing continuous improvement in this parameter. The role of non-invasive echocardiographic assessment of coronary flow reserve in the selection for angioplasty and monitoring of the effects of treatment is discussed.


Asunto(s)
Circulación Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler en Color/métodos , Infarto del Miocardio/diagnóstico por imagen , Adenosina Trifosfato/farmacología , Velocidad del Flujo Sanguíneo , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Vasos Coronarios/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Radiografía