1.
Artif Organs ; 46(11): 2244-2256, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35596611

RESUMEN

BACKGROUND: Left ventricular assist devices (LVADs) have been used as a standard treatment option for patients with advanced heart failure. However, these devices are prone to adverse events. Nonsurgical bleeding (NSB) is the most common complication in patients with continuous flow (CF) LVADs. The development of acquired von Willebrand syndrome (AVWS) in CF-LVAD recipients is thought to be a key factor. However, AVWS is seen across a majority of LVAD patients, not just those with NSB. The purpose of this study was to examine the link between acquired platelet defects and NSB in CF-LVAD patients. METHODS: Blood samples were collected from 62 CF-LVAD patients at pre- and 4 post-implantation timepoints. Reduced adhesion receptor expression (GPIbα and GPVI) and activation of platelets (GPIIb/IIIa activation) were used as markers for acquired platelet defects. RESULTS: Twenty-three patients experienced at least one NSB episode. Significantly higher levels of platelet activation and receptor reduction were seen in the postimplantation blood samples from bleeders compared with non-bleeders. All patients experienced the loss of high molecular weight monomers (HMWM) of von Willebrand Factor (vWF), but no difference was seen between the two groups. Multivariable logistic regression showed that biomarkers for reduced platelet receptor expression (GPIbα and GPVI) and activation (GPIIb/IIIa) have more predictive power for NSB, with the area under curve (AUC) values of 0.72, 0.68, and 0.62, respectively, than the loss of HMWM of vWF (AUC: 0.57). CONCLUSION: The data from this study indicated that the severity of acquired platelet defects has a direct link to NSB in CF-LVAD recipients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Enfermedades de von Willebrand , Humanos , Corazón Auxiliar/efectos adversos , Factor de von Willebrand , Hemorragia/terapia , Hemorragia/complicaciones , Enfermedades de von Willebrand/etiología , Activación Plaquetaria , Insuficiencia Cardíaca/cirugía
2.
Artif Organs ; 46(1): 117-127, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34425001

RESUMEN

We previously reported low rates of pump thrombosis and hemorrhagic stroke, but increased bleeding, under our original antithrombosis protocol (P1) in HeartWare recipients. We designed and implemented a revised protocol (P2) to reduce complexity and bleeding. Thrombelastography and PFA-100 guide antiplatelet titration. Goals for P2 were altered to decrease antiplatelet use and anticoagulation intensity. We compared the incidence and rates of gastrointestinal bleeding (GIB), embolic (eCVA) and hemorrhagic (hCVA) stroke, pump thrombosis (PT), and total bleeding (GIB+hCVA), total thrombosis (eCVA+PT), and total events between P1 and P2. Laboratory and medication data were assessed. Patients with and without hemocompatibility-related adverse events (HRAEs) were compared. The study included 123 patients (P1: 65; P2: 58). GIB rate decreased (P1: 0.66; P2 0.30 EPPY, P = .003). CVA rates and incidence were statistically similar, although hCVA incidence increased (P1: 3%; P2: 12%, P = .06). Incidence (P1: 3%; P2: 16%, P = .02) and rate (P1: 0.03; P2: 0.12 EPPY, P = .08) of PT increased. Incidence and rate of overall HRAEs and thrombotic events were similar, while bleeding rate decreased (P1: 0.69; P2: 0.40 EPPY, P = .02). Twelve-month medication burden decreased. Compared to non-HRAE patients, patients with bleeding HRAEs had more antiplatelet and pentoxifylline use, but less statin use; and lower PFAs. Patients with thrombotic HRAEs had less dual antiplatelet use, lower INRs, R-times, and PFA-ADP values. A revised antithrombotic protocol decreased GIB and overall hemorrhagic HRAE rate and medication burden. Unfortunately, PT increased. Non-HRAE and HRAE patients differed in anticoagulation and antiplatelet intensity. These differences will guide the revision of P2.


Asunto(s)
Fibrinolíticos/uso terapéutico , Corazón Auxiliar/efectos adversos , Trombosis/prevención & control , Femenino , Fibrinolíticos/administración & dosificación , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tromboelastografía
3.
J Card Surg ; 35(7): 1539-1547, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32579786

RESUMEN

BACKGROUND: Despite improved survival and morbidity after durable left ventricular assist device (dLVAD), outcomes for cardiogenic shock patients are suboptimal. Temporary mechanical circulatory support (tMCS) can permit optimization before dLVAD. Excellent outcomes have been observed using minimally-invasive dLVAD implantation. However, some feel tMCS contraindicates this approach. To evaluate whether left thoracotomy/hemisternotomy (LTHS) dLVAD placement is safe in this setting, we compared patients who did and did not require tMCS. METHODS: Outcomes for patients receiving dLVADs via LTHS were compared among those bridged with extracorporeal membrane oxygenation (ECMO), intra-aortic balloon pump (IABP), or no tMCS. We evaluated demographics, comorbidities, laboratory and hemodynamic data, and intraoperative and postoperative outcomes. RESULTS: Eighty-three patients underwent LTHS dLVAD placement. Fifty did not require tMCS, while 22 (26%) required IABP, and 11 (13%) ECMO. Non-tMCS patients were primarily Intermacs 3 (56%), while IABP recipients were mainly Intermacs 2 (45%). All patients with ECMO were Intermacs 1. Patients with tMCS had worse end-organ function. Operative outcomes were similar except more concomitant procedures and red-cell transfusions in patients with ECMO. Intensive care unit and hospital length of stay and inotrope duration were also similar. There were no differences in bleeding, stroke, and infection rates. Three- and 12-month survival were: no tMCS: 94%, 86%; IABP: 100%, 88%; and ECMO: 81%, 81% (P = .45). CONCLUSIONS: Patients with cardiogenic shock can safely undergo LTHS dLVAD implantation after stabilization with ECMO or IABP. Outcomes and complications in these patients were comparable to a less severely ill cohort without tMCS.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Contrapulsador Intraaórtico , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Implantación de Prótesis/métodos , Choque Cardiogénico/terapia , Esternotomía/métodos , Toracotomía/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad , Choque Cardiogénico/mortalidad , Tasa de Supervivencia , Resultado del Tratamiento
4.
J Card Surg ; 34(12): 1465-1469, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31692120

RESUMEN

BACKGROUND: Obesity and heart failure rates continue to rise, confronting heart failure centers with challenging left ventricular assist device (LVAD) implantations. Although less invasive approaches to implantation have been successfully implemented by many centers, this surgical approach has not yet been well evaluated in the obese population. Therefore, we sought to describe our experience with less invasive device implantation in this patient cohort. METHODS: All implants of centrifugal ventricular assist devices were retrospectively reviewed. Patients implanted with a less invasive approach via a left thoracotomy and upper hemisternotomy were included. Patients were stratified by body mass index (<30 vs ≥30 kg/m2 ). Perioperative and short-term outcomes were evaluated. RESULTS: Forty-two patients implanted with the less invasive approach (BMI <30: 27 vs. BMI ≥30 kg/m2 : 15) were identified. The obese cohort was significantly younger (58.5 vs 46.1 years, P = .022), while other preoperative demographics were similar. Postoperative mechanical ventilator time was longer in the obese cohort (22.9 vs 46.1 hour, P = .045). However, other perioperative and short-term outcomes were comparable. Wound dehiscence occurred in one obese patient. Six-month survival was also comparable between cohorts (96.3% vs 86.7%, P = .264). CONCLUSIONS: In this limited patient series, outcomes appear to be comparable in nonobese and obese patients undergoing less invasive LVAD implantation. Therefore, obesity should perhaps not be viewed as a lone contraindication to the application of this surgical approach.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Obesidad/complicaciones , Implantación de Prótesis/métodos , Anciano , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias , Estudios Retrospectivos
5.
Mol Cell Biochem ; 433(1-2): 125-137, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28343311

RESUMEN

Non-surgical bleeding (NSB) is the most common clinical complication in heart failure (HF) patients supported by continuous-flow left ventricular assist devices (CF-LVADs). In this study, oxidative stress and alteration of signal pathways leading to platelet apoptosis were investigated. Thirty-one HF patients supported by CF-LVADs were divided into bleeder (n = 12) and non-bleeder (n = 19) groups. Multiple blood samples were collected at pre-implant (baseline) and weekly up to 1-month post-implant. A single blood sample was collected from healthy subjects (reference). Production of reactive oxygen species (ROS) in platelets, total antioxidant capacity (TAC), oxidized low-density lipoproteins (oxLDL), expression of Bcl-2 and Bcl-xL, Bax and release of cytochrome c (Cyt.c), platelet mitochondrial membrane potential (Δψ m), activation of caspases, gelsolin cleavage and platelet apoptosis were examined. Significantly elevated ROS, oxLDL and depleted TAC were evident in the bleeder group compared to non-bleeder group (p < 0.05). Platelet pro-survival proteins (Bcl-2, Bcl-xL) were significantly reduced in the bleeder group in comparison to the non-bleeder group (p < 0.05). Translocation of Bax into platelet mitochondria membrane and subsequent release of Cyt.c were more prevalent in the bleeder group. Platelet mitochondrial damage, activation of caspases, gelsolin cleavage, and ultimate platelet apoptosis in the bleeder group were observed. Oxidative stress and activation of both intrinsic and extrinsic pathways of platelet apoptosis may be linked to NSB in CF-LVAD patients. Additionally, biomarkers of oxidative stress, examination of pro-survivals and pro-apoptotic proteins in platelets, mitochondrial damage, caspase activation, and platelet apoptosis may be used to help identify HF patients at high risk of NSB post-implant.


Asunto(s)
Apoptosis , Plaquetas/metabolismo , Insuficiencia Cardíaca , Corazón Auxiliar/efectos adversos , Hemorragia , Estrés Oxidativo , Adulto , Anciano , Plaquetas/patología , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/terapia , Hemorragia/sangre , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad
6.
Artif Organs ; 40(5): 434-43, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26416627

RESUMEN

The role of oxidative stress and leukocyte activation has not been elucidated in developing systemic inflammatory response syndrome (SIRS) in heart failure (HF) patients after continuous-flow left ventricular assist device (CF-LVAD) implantation. The objective of this study was to investigate the change of plasma redox status and leukocyte activation in CF-LVAD implanted HF patients with or without SIRS. We recruited 31 CF-LVAD implanted HF patients (16 SIRS and 15 non-SIRS) and 11 healthy volunteers as the control. Pre- and postimplant blood samples were collected from the HF patients. Plasma levels of oxidized low-density lipoprotein (oxLDL), malondialdehyde (MDA), total antioxidant capacity (TAC), superoxide dismutase (SOD) in erythrocyte, myeloperoxidase (MPO), and polymorphonuclear elastase (PMN-elastase) were measured. The HF patients had a preexisting condition of oxidative stress than healthy controls as evident from the higher oxLDL and MDA levels as well as depleted SOD and TAC. Leukocyte activation in terms of higher plasma MPO and PMN-elastase was also prominent in HF patients than controls. Persistent oxidative stress and reduced antioxidant status were found to be more belligerent in HF patients with SIRS after the implantation of CF-LVAD when compared with non-SIRS patients. Similar to oxidative stress, the activation of blood leukocyte was significantly highlighted in SIRS patients after implantation compared with non-SIRS. We identified that the plasma redox status and leukocyte activation became more prominent in CF-LVAD implanted HF patients who developed SIRS. Our findings suggest that plasma biomarkers of oxidative stress and leukocyte activation may be associated with the development of SIRS after CF-LVAD implant surgery.


Asunto(s)
Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Leucocitos/patología , Estrés Oxidativo , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/cirugía , Humanos , Lipoproteínas LDL/sangre , Masculino , Malondialdehído/sangre , Persona de Mediana Edad , Oxidación-Reducción , Síndrome de Respuesta Inflamatoria Sistémica/patología
7.
J Card Fail ; 21(7): 564-71, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25921521

RESUMEN

BACKGROUND: The objective of this study was to investigate the change of platelet function and platelet mitochondrial membrane potential in contentious-flow left ventricular assist device (CF-LVAD)-implanted heart failure (HF) patients with or without systemic inflammatory response syndrome (SIRS). METHODS AND RESULTS: We recruited 31 CF-LVAD patients (16 SIRS and 15 non-SIRS) and 11 healthy volunteers as control. Pre- and post-implantation blood samples were collected. We used PFA-100 to test platelet functionality. Mitochondrial potential-sensitive dye was used to detect platelet dysfunction (mitochondrial membrane potential; ΔΨm) via flow cytometry. The percentage of depolarized-ΔΨm platelets was found to be a preexisting condition in all HF patients before CF-LVAD implantation compared with control subjects (10.3 ± 6.3% vs 2.8 ± 2.2%; P < .001). As evident from the PFA-100 test, the HF patients who developed SIRS after CF-LVAD implantation had significantly more qualitative platelet defects and thrombocytopathies compared with baseline. After implantation, the depolarized platelets in the SIRS patients increased by 2-fold compared with baseline (18.2 ± 8.4% vs 9.0 ± 6.6%; P < .01); whereas no change was noticed in the non-SIRS patients (10.9 ± 6.2% vs 11.7 ± 5.8%; P = .75). CONCLUSIONS: We identified that platelet function and mitochondrial damage were enhanced in CF-LVAD patients with SIRS. Our findings suggest that depolarization of mitochondrial membrane potential is associated with SIRS after CF-LVAD implantation surgery.


Asunto(s)
Trastornos de las Plaquetas Sanguíneas , Plaquetas/metabolismo , Insuficiencia Cardíaca , Corazón Auxiliar/efectos adversos , Potencial de la Membrana Mitocondrial , Síndrome de Respuesta Inflamatoria Sistémica , Adulto , Anciano , Trastornos de las Plaquetas Sanguíneas/complicaciones , Trastornos de las Plaquetas Sanguíneas/diagnóstico , Trastornos de las Plaquetas Sanguíneas/metabolismo , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Atención Perioperativa/métodos , Pruebas de Función Plaquetaria/métodos , Índice de Severidad de la Enfermedad , Estadística como Asunto , Síndrome de Respuesta Inflamatoria Sistémica/sangre , Síndrome de Respuesta Inflamatoria Sistémica/etiología
8.
Platelets ; 26(6): 536-44, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25167344

RESUMEN

Non-surgical bleeding (NSB) is the most common clinical complication among heart failure (HF) patients supported by continuous-flow left ventricular assist devices (CF-LVADs). Understanding the role of platelet functionality contributing to NSB after CF-LVAD implantation is crucial for prevention and management of this adverse event. The aim of this study was to examine the role of intraplatelet reactive oxygen species (ROS) and platelet damage on the incidence of bleeding events after CF-LVAD implantation in HF patients. We recruited 25 HF patients implanted with CF-LVADs and 11 healthy volunteers as the control. Intraplatelet ROS generation, platelet mitochondrial damage and platelet apoptosis were quantified by flow cytometry. Among 25 patients, 8 patients developed non-surgical bleeding within one month after CF-LVAD implantation. Intraplatelet ROS, depolarized and apoptotic platelet were found to be pre-existing conditions in all baseline samples of the 25 HF patients when compared to the healthy volunteers. There was no significant difference in the levels of ROS between the non-bleeder and the bleeder groups prior to CF-LVAD implantation, although we noticed 2-fold and 1.5-fold rise in depolarized and apoptotic platelets, respectively, in the bleeder group compared to those in the non-bleeder group. Post implant levels of intraplatelet ROS, depolarized and apoptotic platelets increased and remained elevated in the bleeder group, whereas periodic decreases were noticed in the non-bleeder group, suggesting the potential role of platelet damage on bleeding incidence. ROS generation after CF-LVAD implantation positively associated with platelet apoptosis (ρ = 0.4263, p = 0.0023) and depolarized platelets (ρ = 0.4774, p = 0.0002), especially the latter. In conclusion, elevated intraplatelet ROS and platelet damage may be linked to the NSB among HF patients supported by CF-LVAD. These results provide mechanistic insights into the bleeding complication in patients with CF-LVAD support.


Asunto(s)
Apoptosis , Plaquetas/metabolismo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/metabolismo , Hemorragia/etiología , Mitocondrias/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Adulto , Anciano , Coagulación Sanguínea , Estudios de Casos y Controles , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Humanos , Masculino , Potencial de la Membrana Mitocondrial , Persona de Mediana Edad , Pruebas de Función Plaquetaria , Adulto Joven
11.
Innovations (Phila) ; 16(2): 157-162, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33410713

RESUMEN

OBJECTIVE: We have observed that minimally invasive left ventricular assist device (LVAD) insertion leads to more facile re-entry and easier cardiac transplantation. We hypothesize minimally invasive LVAD implantation results in improved outcomes at the time of subsequent heart transplant. METHODS: All adults undergoing cardiac transplantation between October 2015 and March 2019 at our institution were retrospectively reviewed. Those bridged to transplantation with a HeartWare HVAD were identified and divided into 2 cohorts based upon the surgical approach: those who underwent HVAD placement by conventional sternotomy versus minimally invasive insertion via lateral thoracotomy and hemisternotomy (LTHS). Patient demographics, as well as perioperative transplant outcomes, including survival, length of stay (LOS), blood utilization, ischemic time, bypass time, and postoperative extracorporeal membrane oxygenation (ECMO) were compared between cohorts. RESULTS: Forty-two patients were bridged to heart transplant with a HVAD implanted via either sternotomy (n = 22) or LTHS technique (n = 20). Demographics were similar between groups. There was 1 predischarge death in the sternotomy group and none in the LTHS group. Body surface area, cardiopulmonary bypass time, ischemic time, ECMO utilization, and reoperation for bleeding were similar. Red blood cell units transfused were significantly lower in the LTHS cohort (3.0 [1.0-5.0] vs 6.0 [2.5-10.0] P = 0.046). The LTHS cohort had a significantly shorter hospital LOS (12.0 [11.0-28.0] vs 22.5 [15.7-41.7] P = 0.022) with a trend toward shorter intensive care unit LOS (6.0 [5.0-10.5] vs 11.0 [6.0-21.5] days P = 0.057). CONCLUSIONS: Minimally invasive HVAD implantation improves outcomes at subsequent heart transplantation, resulting in shorter LOS and less red cell transfusion. Larger multi-institutional studies are necessary to validate these findings.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Implantación de Prótesis , Estudios Retrospectivos , Esternotomía , Resultado del Tratamiento
12.
J Cardiovasc Transl Res ; 14(3): 484-491, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33175315

RESUMEN

Gastrointestinal bleeding (GIB) is a frequent complication in patients with continuous-flow left ventricular assist devices (LVAD). We retrospectively evaluated eight patients implanted with a HeartWare LVAD between July 2017 and June 2020 who experienced at least one episode of GIB and were started on tamoxifen 20 mg once daily for secondary prevention. Tamoxifen was associated with a significant decrease in major GIB from a median of 3 (IQR 1.4-7) events/patient-year pre-tamoxifen initiation to 0 (IQR 0-0.9) events/patient-year post-tamoxifen initiation (p = 0.02). Transfusion of packed red blood cells also decreased from 16.8 (IQR 9.9-30.6) units/patient-year pre-tamoxifen initiation to 1.5 (IQR 0-7.5) units/patient-year post-tamoxifen (p = 0.04). Tamoxifen was well tolerated and no thromboembolic complications were observed. This small cohort study suggests that tamoxifen is associated with reduced GIB and transfusion requirements, with no apparent increase in thrombotic risk. A larger, randomized study is warranted to confirm the results of this exploratory analysis. Graphical abstract.


Asunto(s)
Hemorragia Gastrointestinal/prevención & control , Corazón Auxiliar/efectos adversos , Hemostáticos/uso terapéutico , Implantación de Prótesis/efectos adversos , Prevención Secundaria , Tamoxifeno/uso terapéutico , Adulto , Transfusión de Eritrocitos , Femenino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/instrumentación , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
13.
Innovations (Phila) ; 16(1): 104-107, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33205685

RESUMEN

A minimally invasive approach to left ventricular assist device (LVAD) insertion may benefit patients at the time of implant, but whether the approach to LVAD insertion influences the outcome of subsequent cardiovascular reoperations is unknown. Here we present the case of a 50-year-old male who underwent LVAD insertion through a minimally invasive approach and subsequently had left ventricular recovery. LVAD explant was performed without the use of any blood products or inotropic support. This case demonstrates that a minimally invasive approach to LVAD insertion may also facilitate subsequent device explant.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
14.
ASAIO J ; 65(1): 29-35, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29461279

RESUMEN

There are no evidence-based guidelines for antithrombotic therapy in left ventricular assist device patients. We evaluated the efficacy of a multi-agent, test-guided protocol, which remained consistent throughout our use of the Heartware HVAD. Thrombelastography and platelet function analyzer (PFA)-100 guide antiplatelet titration. Goals are normal kaolin thrombelastography maximum amplitude and prolonged PFA-100. We analyzed incidence and rates of nonprocedural bleeding, stroke, and pump thrombosis for all 81 primary Heartware left ventricular assist devices implanted since 2011. For each event, we examined whether each test was within goal range. We also compared medication burden and dosage between patients with and without events. Pump thrombosis and hemorrhagic stroke each occurred in two patients (2.5%; 0.03 events/patient-year [EPPY]), and ischemic stroke in six (7.4%; 0.10 EPPY). Nonprocedural bleeding occurred 75 times in 34 patients (42%; 1.24 EPPY), primarily gastrointestinal (28%; 0.66 EPPY). Subtherapeutic international normalized ratio (INR) was the most common at thrombotic events; supratherapeutic partial thromboplastin time, international normalized ratio (INR), and PFA-adenosine diphosphate (ADP) were common at bleeding events. Medication burden and dosage were lower in patients with events than in stable patients. Protocol-guided antithrombotic therapy resulted in low rates of pump thrombosis and hemorrhagic stroke. Ischemic stroke and gastrointestinal bleeding rates were higher than in a comparable HVAD population. Optimization of our protocol to decrease its complexity and to reduce bleeding is underway.


Asunto(s)
Fibrinolíticos/uso terapéutico , Corazón Auxiliar , Trombosis/prevención & control , Adulto , Femenino , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Trombosis/etiología
15.
Ann Thorac Surg ; 105(5): 1377-1383, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29305851

RESUMEN

BACKGROUND: We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. METHODS: Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. RESULTS: Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 ± 16.8 versus -18.7 ± 11.6 degrees, p < 0.001; lateral plane angle 23.7 ± 20.1 versus 0.2 ± 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). CONCLUSIONS: We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction.


Asunto(s)
Cánula , Falla de Equipo , Corazón Auxiliar , Trombosis/diagnóstico por imagen , Trombosis/etiología , Adulto , Anciano , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
16.
ASAIO J ; 64(4): 462-471, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28953486

RESUMEN

Nonsurgical bleeding (NSB) in heart failure (HF) patients with continuous-flow left ventricular assist device (CF-LVAD) support is the most common clinical complication. The aim of this study was to investigate the association between oxidative stress and platelet glycoproteins GPIbα and GPVI shedding on the incidence of NSB in CF-LVAD patients. Fifty-one HF patients undergoing CF-LVAD implantation and 11 healthy volunteers were recruited. Fourteen patients developed NSB (bleeder group) during 1 month follow-up duration, while others were considered nonbleeder group (n = 37). Several biomarkers of oxidative stress were quantified at baseline and weekly intervals in all patients. Surface expression and plasma elements of platelet receptor glycoproteins GPIbα and GPVI were measured. Oxidative stress biomarkers and platelet GPIbα and GPVI receptor-shedding (decreased surface expression and higher plasma levels) were found to be preexisting conditions in baseline samples of both groups of HF patients when compared with healthy volunteers. Significantly elevated oxidative stress biomarkers and platelet glycoprotein receptor shedding were observed in postimplant bleeder group temporarily when compared with nonbleeder group. Strong significant associations between biomarkers of oxidative stress and platelet glycoprotein receptor shedding were observed, suggesting a possible role of oxidative stress in platelet integrin shedding leading to NSB in CF-LVAD patients. Receiver operating characteristic analyses of GPIbα and GPVI indicated that the likelihood of NSB had a predictive power of bleeding complication in CF-LVAD patients. In conclusion, elevated oxidative stress may play a role in GPIbα and GPVI shedding in the event of NSB. Thus, oxidative stress and GPIbα and GPVI shedding may be used as potential biomarkers for bleeding risk stratification in those patients.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Hemorragia/etiología , Estrés Oxidativo , Complejo GPIb-IX de Glicoproteína Plaquetaria/análisis , Glicoproteínas de Membrana Plaquetaria/análisis , Adulto , Anciano , Plaquetas/metabolismo , Femenino , Insuficiencia Cardíaca/sangre , Humanos , Masculino , Persona de Mediana Edad
17.
Innovations (Phila) ; 13(3): 218-221, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29912739

RESUMEN

OBJECTIVE: Several centers have presented minimally invasive surgical approaches to centrifugal left ventricular assist device implantation. Although minimally invasive implantation has been successfully performed by experienced surgeons, at large implanting centers, it is unknown whether these techniques are widely adoptable. We evaluated the experience of a surgeon early in his career with conventional and minimally invasive approaches to device implantation. METHODS: All consecutive left ventricular assist device implantations by a single surgeon in the first year of practice (2015-2016) were retrospectively reviewed. Patients were stratified by standard approach, conventional full sternotomy versus a minimally invasive approach, left anterior thoracotomy and upper hemisternotomy. Demographics, perioperative variables, and short-term outcomes were compared using Wilcoxon rank-sum test. RESULTS: Thirteen patients were identified: six performed via the standard approach and seven performed via the minimally invasive approach. Preoperative demographics were comparable in both groups. However, there was significantly more preoperative right ventricle dysfunction in the minimally invasive group (P = 0.01). Although operative time was significantly longer in the minimally invasive cohort, there was a trend toward decreased cardiopulmonary bypass time. Six-month survival in both groups was 100%. CONCLUSIONS: Compared with conventional sternotomy, minimally invasive ventricular assist device implantation, performed by a surgeon in his first year of practice, had similar perioperative outcomes and excellent survival. Based on these data, minimally invasive implantation may be a feasible strategy for device implantation even early in a surgeon's career.


Asunto(s)
Corazón Auxiliar , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Esternotomía , Cirujanos , Resultado del Tratamiento
18.
Thromb Res ; 158: 140-148, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28915447

RESUMEN

INTRODUCTION: Oxidative stress and platelet integrin α2bß3 plays important role in the process of hemostasis and thrombosis. We hypothesized that device-induced patient specific oxidative stress and integrin α2bß3 shedding may be linked to major bleeding complication (MBC) in heart failure (HF) patients supported by continuous flow left ventricular assist devices (CF-LVADs). MATERIALS AND METHODS: We recruited 47patients implanted with CF-LVADs and 15 healthy volunteers. Fourteen patients developed MBC (bleeder group) within one month after implantation while others were considered non-bleeder group (n=33). Oxidative stresses were evaluated by measuring reactive oxygen species (ROS) in platelets, superoxide dismutase (SOD) activity, total antioxidant capacity (TAC) and oxidized low density lipoprotein (oxLDL). Assessments of α2bß3 were carried out using flow cytometry and ELISA. RESULTS: Biomarkers of oxidative stress and α2bß3 shedding (decreased surface expression and higher plasma levels) were found to be preexisting condition in all HF patients prior to CF-LVAD implantation compared to the healthy volunteers. Significantly elevated levels of ROS and oxLDL; concomitant depletion of SOD and TAC; and α2bß3 shedding were observed in the bleeder group temporarily in comparison to the non-bleeder group after CF-LVAD implantation. A significantly strong association between α2bß3 shedding and biomarkers of oxidative stress was observed; suggesting a potential role of oxidative stress in platelet integrin shedding leading to MBC after CF-LVAD implantation. Moreover, a receiver operating characteristic (ROC) analysis indicated that the likelihood of MBC data from Integrin α2bß3 shedding had a predictive power of MBC in CF-LVAD patients. CONCLUSIONS: Oxidative stress might play a potential role in accelerating α2bß3 shedding and platelet dysfunction, resulting in MBC in CF-LVAD patients. Integrin α2bß3 shedding may be used to refine bleeding risk stratification in CF-LVAD patients.


Asunto(s)
Plaquetas/metabolismo , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemorragia/sangre , Integrinas/sangre , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/patología , Humanos , Masculino , Persona de Mediana Edad , Estrés Oxidativo
SELECCIÓN DE REFERENCIAS