Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Environ Mol Mutagen ; 62(2): 155-164, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33341964

RESUMEN

Considering the importance and lack of data of toxicogenomic approaches on occupational exposure to anesthetics, we evaluated possible associations between waste anesthetic gases (WAGs) exposure and biological effects including oxidative stress, DNA damage, inflammation, and transcriptional modulation. The exposed group was constituted by anesthesia providers who were mainly exposed to the anesthetics sevoflurane and isoflurane (10 ppm) and to a lesser degree to nitrous oxide (150 ppm), and the control group was constituted by physicians who had no exposure to WAGs. The oxidative stress markers included oxidized DNA bases (comet assay), malondialdehyde (high-performance liquid chromatography [HPLC]), nitric oxide metabolites (ozone-chemiluminescence), and antioxidative markers, including individual antioxidants (HPLC) and antioxidant defense marker (ferric reducing antioxidant power by spectrophotometry). The inflammatory markers included high-sensitivity C-reactive protein (chemiluminescent immunoassay) and the proinflammatory interleukins IL-6, IL-8 and IL-17A (flow cytometry). Telomere length and gene expression related to DNA repair (hOGG1 and XRCC1), antioxidant defense (NRF2) and inflammation (IL6, IL8 and IL17A) were evaluated by real-time quantitative polymerase chain reaction. No significant differences (p > .0025) between the groups were observed for any parameter evaluated. Thus, under the conditions of the study, the findings suggest that occupational exposure to WAGs is not associated with oxidative stress or inflammation when evaluated in serum/plasma, with DNA damage evaluated in lymphocytes and leucocytes or with molecular modulation assessed in peripheral blood cells in university anesthesia providers. However, it is prudent to reduce WAGs exposure and to increase biomonitoring of all occupationally exposed professionals.


Asunto(s)
Anestesia/efectos adversos , Anestésicos por Inhalación/efectos adversos , Daño del ADN/efectos de los fármacos , Expresión Génica/efectos de los fármacos , Inflamación/inducido químicamente , Exposición Profesional/efectos adversos , Estrés Oxidativo/efectos de los fármacos , Adulto , Anciano , Contaminantes Ocupacionales del Aire/efectos adversos , Antioxidantes/metabolismo , Reparación del ADN/efectos de los fármacos , Femenino , Hospitales , Humanos , Inflamación/metabolismo , Isoflurano/efectos adversos , Masculino , Persona de Mediana Edad , Óxido Nitroso/efectos adversos , Sevoflurano/efectos adversos
2.
Rev Bras Anestesiol ; 67(5): 516-520, 2017.
Artículo en Portugués | MEDLINE | ID: mdl-28259354

RESUMEN

BACKGROUND AND OBJECTIVES: Occupational exposure to waste anesthetic gases in operating room (OR) without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhaled anesthetics isoflurane and sevoflurane in OR with and without central scavenging system. METHOD: Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120minutes after the start of surgery) in both OR types. RESULTS: All isoflurane and sevoflurane concentrations in unscavenged OR were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged OR, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. CONCLUSIONS: The exposure to both anesthetics exceeded the international limit in unscavenged OR. In scavenged OR, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the OR scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.


Asunto(s)
Contaminación del Aire Interior/análisis , Anestésicos por Inhalación/análisis , Depuradores de Gas , Isoflurano/análisis , Sevoflurano/análisis , Brasil , Hospitales Universitarios , Quirófanos
3.
Rev. bras. anestesiol ; 67(5): 516-520, Sept-Oct. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-897762

RESUMEN

Abstract Background and objectives Occupational exposure to waste anesthetic gases in operating room without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhalational anesthetics isoflurane and sevoflurane in operating room with and without central scavenging system. Method Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120 min after the start of surgery) in both operating room types. Results All isoflurane and sevoflurane concentrations in unscavenged operating room were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged operating room, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. Conclusions The exposure to both anesthetics exceeded the international limit in unscavenged operating room. In scavenged operating room, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the operating room scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.


Resumo Justificativa e objetivos A exposição ocupacional aos resíduos de gases anestésicos em salas de operação (SO) sem sistema ativo de exaustão tem sido associada a efeitos adversos à saúde. Assim, o objetivo do estudo foi comparar os resíduos dos anestésicos inalatórios isoflurano e sevoflurano em SO com e sem sistema de exaustão. Método Concentrações residuais de isoflurano e sevoflurano foram mensuradas por analisador infravermelho em diferentes locais (próximo à área respiratória do auxiliar de enfermagem e do anestesiologista e próximo à estação de anestesia) e em dois momentos (30 e 120 min após o início da cirurgia) em ambos os tipos de SO. Resultados Todas as concentrações de isoflurano e sevoflurano nas SO sem sistema de exaustão foram mais elevadas em relação ao valor limite recomendado pelos EUA (2 partes por milhão), independentemente do local e momento avaliados. Nas SO com sistema de exaustão, as concentrações médias de isoflurano ficaram dentro do limite de exposição, exceto para as mensurações próximas à estação de anestesia, independentemente dos momentos avaliados. Para o sevoflurano, as concentrações excederam o valor limite em todos locais de medição e nos dois momentos. Conclusões A exposição a ambos os anestésicos excedeu o limite internacional nas SO sem sistema de exaustão. Nas SO com sistema de exaustão, as concentrações de sevoflurano, e em menor extensão, as de isoflurano excederam o valor limite recomendado. Dessa forma, o sistema de exaustão das SO analisado no presente estudo diminuiu as concentrações dos anestésicos, embora não tenha reduzido a valores internacionalmente recomendados.


Asunto(s)
Depuradores de Gas , Contaminación del Aire Interior/análisis , Anestésicos por Inhalación/análisis , Sevoflurano/análisis , Isoflurano/análisis , Quirófanos , Brasil , Hospitales Universitarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA