Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 282
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-37952132

RESUMEN

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Asunto(s)
Anticoagulantes , Aspirina , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Canadá , Embolia/etiología , Embolia/prevención & control , Hemorragia/inducido químicamente , Piridonas/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Método Doble Ciego
2.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412340

RESUMEN

The DF-4 defibrillator standard has been rapidly adopted due to its convenience at implantation. There are however trade-offs compared to the traditional DF-1 standard that are underappreciated. This viewpoint outlines the advantages and limitations of current defibrillator lead standards that should be kept in mind, as they impact the options that are available to deal with issues that may arise.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38607938

RESUMEN

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Sistema de Registros , Reoperación , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Suiza/epidemiología , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos
4.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38693772

RESUMEN

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Asunto(s)
Arritmias Cardíacas , Cardiomiopatías , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Femenino , Masculino , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Persona de Mediana Edad , Adulto , Europa (Continente) , Encuestas y Cuestionarios , Volumen Sistólico , Encuestas de Atención de la Salud , Antiarrítmicos/uso terapéutico , Pautas de la Práctica en Medicina/estadística & datos numéricos , Función Ventricular Izquierda , Ablación por Catéter , Cardiólogos
5.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37062040

RESUMEN

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Resultado del Tratamiento , Incidencia , Factores de Riesgo , Fístula Esofágica/epidemiología , Fístula Esofágica/etiología , Fístula Esofágica/diagnóstico , Pronóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
6.
J Cardiovasc Electrophysiol ; 34(6): 1464-1468, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37146212

RESUMEN

INTRODUCTION: Electrophysiological testing has been proposed in the latest European Society of Cardiology (ESC) guidelines for cardiac pacing to identify left bundle branch block (LBBB) patients with infrahisian conduction delay (IHCD) after transcatheter aortic valve replacement (TAVR). While in general IHCD is defined by a His-ventricular (HV) interval of >55 ms, a cut-off of ≥70 ms to trigger pacemaker (PM) implantation has been proposed in the latest ESC guidelines. The ventricular pacing (VP) burden during follow-up in such patients is largely unknown. As such, we aimed to assess the VP burden during follow-up of patients receiving PM therapy for LBBB after TAVR based on an HV interval > 55 ms and ≥70 ms. METHODS: All patients with new-onset or pre-existing LBBB after undergoing TAVR at a tertiary referral center underwent EP testing the day after TAVR. In patients with a prolonged HV interval (>55 ms), PM implantation was performed by a trained electrophysiologist in a standardized fashion. All devices were programmed to avoid unnecessary VP by specific algorithms (e.g., AAI-DDD). RESULTS: 701 patients underwent TAVR at the University Hospital of Basel. One hundred seventy-seven patients presented with new-onset or pre-existing LBBB the day following TAVR and underwent EP testing. An HV interval > 55 ms was found in 58 patients (33%) and an HV interval ≥ 70 ms in 21 patients (12%). 51 patients (mean age 84 ± 6.2 years, 45% women) agreed to receive a PM, out of which 20 (39%) patients had an HV Interval over 70 ms. Atrial fibrillation was present in 53% of the patients. A dual chamber PM was implanted in 39 (77%), and a single chamber PC in 12 (23%) patients, respectively. Median follow-up was 21 months. The median VP burden overall was 3%. The median VP burden was not significantly different between patients with an HV ≥ 70 ms (6.5 [0.8-52]) and those with an HV between 55 and 69 ms (2 [0-17], p = .23). 31% of patients demonstrated a VP burden < 1%, 27% 1%-5% and 41% > 5%. The median HV intervals in patients with VP burdens < 1%, 1%-5% and >5% were 66 (IQR 62-70) ms, 66 (IQR 63-74) ms and 68 (IQR 60-72) ms, respectively, p = .52. When only assessing patients with an HV interval 55-69 ms, 36% demonstrated a VP burden of <1%, 29% of 1%-5% and 35% of >5%. In patients with an HV Interval ≥ 70 ms, 25% demonstrated a VP burden < 1%, 25% of 1%-5% and 50% of >5% %, p = .64 (Figure). CONCLUSION: In patients with LBBB after TAVR and IHCD defined by an HV interval > 55 ms, VP burden is relevant in a non-negligible amount of patients during follow-up. Further studies are warranted to define the optimal cut-off value for the HV interval or to develop risk models incorporating HV measurements and other risk factors to trigger PM implantation in patients with LBBB after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Marcapaso Artificial/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
7.
Value Health ; 26(12): 1721-1729, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37741443

RESUMEN

OBJECTIVES: Randomized controlled trials of pulmonary vein isolation (PVI) for treating atrial fibrillation (AF) have proven the procedure's efficacy. Studies assessing its empirical cost-effectiveness outside randomized trial settings are lacking. We aimed to evaluate the effectiveness and cost-effectiveness of PVI versus medical therapy for AF. METHODS: We followed a target trial approach using the Swiss-AF cohort, a prospective observational cohort study that enrolled patients with AF between 2014 and 2017. Resource utilization and cost information were collected through claims data. Quality of life was measured with EQ-5D-3L utilities. We estimated incremental cost-effectiveness ratios (ICERs) from the perspective of the Swiss statutory health insurance system. RESULTS: Patients undergoing PVI compared with medical therapy had a 5-year overall survival advantage with a hazard ratio of 0.75 (95% CI 0.46-1.21; P = .69) and a 19.8% SD improvement in quality of life (95% CI 15.5-22.9; P < .001), at an incremental cost of 29 604 Swiss francs (CHF) (95% CI 16 354-42 855; P < .001). The estimated ICER was CHF 158 612 per quality-adjusted life-year (QALY) gained within a 5-year time horizon. Assuming similar health effects and costs over 5 additional years changed the ICER to CHF 82 195 per QALY gained. Results were robust to the sensitivity analyses performed. CONCLUSIONS: Our results show that PVI might be a cost-effective intervention within the Swiss healthcare context in a 10-year time horizon, but unlikely to be so at 5 years, if a willingness-to-pay threshold of CHF 100 000 per QALY gained is assumed. Given data availability, we find target trial designs are a valuable tool for assessing the cost-effectiveness of healthcare interventions outside of randomized controlled trial settings.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Análisis Costo-Beneficio , Calidad de Vida , Venas Pulmonares/cirugía , Estudios Prospectivos , Años de Vida Ajustados por Calidad de Vida
8.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37102266

RESUMEN

Sudden cardiac death and ventricular arrhythmias are a global health issue. Recently, a new guideline for the management of ventricular arrhythmias and prevention of sudden cardiac death has been published by the European Society of Cardiology that serves as an update to the 2015 guideline on this topic. This review focuses on 10 novel key aspects of the current guideline: As new aspects, public basic life support and access to defibrillators are guideline topics. Recommendations for the diagnostic evaluation of patients with ventricular arrhythmias are structured according to frequently encountered clinical scenarios. Management of electrical storm has become a new focus. In addition, genetic testing and cardiac magnetic resonance imaging significantly gained relevance for both diagnostic evaluation and risk stratification. New algorithms for antiarrhythmic drug therapy aim at improving safe drug use. The new recommendations reflect increasing relevance of catheter ablation of ventricular arrhythmias, especially in patients without structural heart disease or stable coronary artery disease with only mildly impaired ejection fraction and haemodynamically tolerated ventricular tachycardias. Regarding sudden cardiac death risk stratification, risk calculators for laminopathies, and long QT syndrome are now considered besides the already established risk calculator for hypertrophic cardiomyopathy. Generally, 'new' risk markers beyond left ventricular ejection fraction are increasingly considered for recommendations on primary preventive implantable cardioverter defibrillator therapy. Furthermore, new recommendations for diagnosis of Brugada syndrome and management of primary electrical disease have been included. With many comprehensive flowcharts and practical algorithms, the new guideline takes a step towards a user-oriented reference book.


Asunto(s)
Desfibriladores Implantables , Función Ventricular Izquierda , Humanos , Volumen Sistólico , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Corazón
9.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37622589

RESUMEN

This article will discuss the past, present, and future of ventricular tachycardia ablation and the continuing contribution of the Europace journal as the platform for publication of milestone research papers in this field of ventricular tachycardia ablation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos
10.
Europace ; 2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37165671

RESUMEN

BACKGROUND: Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS: The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS: Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION: When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters.

11.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38036293

RESUMEN

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
12.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37944133

RESUMEN

AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2-7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69-73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74-83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78-89, one study) and PFA (87%, 95%CI 84-90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Factores de Tiempo , Resultado del Tratamiento , Recurrencia
13.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37314197

RESUMEN

AIMS: Atrial remodelling, defined as a change in atrial structure, promotes atrial fibrillation (AF). Bone morphogenetic protein 10 (BMP10) is an atrial-specific biomarker released to blood during atrial development and structural changes. We aimed to validate whether BMP10 is associated with AF recurrence after catheter ablation (CA) in a large cohort of patients. METHODS AND RESULTS: We measured baseline BMP10 plasma concentrations in AF patients who underwent a first elective CA in the prospective Swiss-AF-PVI cohort study. The primary outcome was AF recurrence lasting longer than 30 s during a follow-up of 12 months. We constructed multivariable Cox proportional hazard models to determine the association of BMP10 and AF recurrence. A total of 1112 patients with AF (age 61 ± 10 years, 74% male, 60% paroxysmal AF) was included in our analysis. During 12 months of follow-up, 374 patients (34%) experienced AF recurrence. The probability for AF recurrence increased with increasing BMP10 concentration. In an unadjusted Cox proportional hazard model, a per-unit increase in log-transformed BMP10 was associated with a hazard ratio (HR) of 2.28 (95% CI 1.43; 3.62, P < 0.001) for AF recurrence. After multivariable adjustment, the HR of BMP10 for AF recurrence was 1.98 (95% CI 1.14; 3.42, P = 0.01), and there was a linear trend across BMP10 quartiles (P = 0.02 for linear trend). CONCLUSION: The novel atrial-specific biomarker BMP10 was strongly associated with AF recurrence in patients undergoing CA for AF. CLINICALTRIALS.GOV IDENTIFIER: NCT03718364; https://clinicaltrials.gov/ct2/show/NCT03718364.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Cohortes , Estudios Prospectivos , Proteínas Morfogenéticas Óseas , Ablación por Catéter/efectos adversos
14.
Pacing Clin Electrophysiol ; 46(10): 1186-1196, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37616339

RESUMEN

BACKGROUND: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS: In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS: We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION: The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin.

15.
Eur Heart J ; 43(40): 4177-4191, 2022 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-35187560

RESUMEN

AIMS: Fragmented QRS complex with visible notching on standard 12-lead electrocardiogram (ECG) is understood to represent depolarization abnormalities and to signify risk of cardiac events. Depolarization abnormalities with similar prognostic implications likely exist beyond visual recognition but no technology is presently suitable for quantification of such invisible ECG abnormalities. We present such a technology. METHODS AND RESULTS: A signal processing method projects all ECG leads of the QRS complex into optimized three perpendicular dimensions, reconstructs the ECG back from this three-dimensional projection, and quantifies the difference (QRS 'micro'-fragmentation, QRS-µf) between the original and reconstructed signals. QRS 'micro'-fragmentation was assessed in three different populations: cardiac patients with automatic implantable cardioverter-defibrillators, cardiac patients with severe abnormalities, and general public. The predictive value of QRS-µf for mortality was investigated both univariably and in multivariable comparisons with other risk factors including visible QRS 'macro'-fragmentation, QRS-Mf. The analysis was made in a total of 7779 subjects of whom 504 have not survived the first 5 years of follow-up. In all three populations, QRS-µf was strongly predictive of survival (P < 0.001 univariably, and P < 0.001 to P = 0.024 in multivariable regression analyses). A similar strong association with outcome was found when dichotomizing QRS-µf prospectively at 3.5%. When QRS-µf was used in multivariable analyses, QRS-Mf and QRS duration lost their predictive value. CONCLUSION: In three populations with different clinical characteristics, QRS-µf was a powerful mortality risk factor independent of several previously established risk indices. Electrophysiologic abnormalities that contribute to increased QRS-µf values are likely responsible for the predictive power of visible QRS-Mf.


Asunto(s)
Electrocardiografía , Humanos , Electrocardiografía/métodos , Factores de Riesgo , Pronóstico , Valor Predictivo de las Pruebas
16.
Eur Heart J ; 43(22): 2127-2135, 2022 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-35171989

RESUMEN

AIMS: We aimed to investigate the association of clinically overt and silent brain lesions with cognitive function in atrial fibrillation (AF) patients. METHODS AND RESULTS: We enrolled 1227 AF patients in a prospective, multicentre cohort study (Swiss-AF). Patients underwent standardized brain magnetic resonance imaging (MRI) at baseline and after 2 years. We quantified new small non-cortical infarcts (SNCIs) and large non-cortical or cortical infarcts (LNCCIs), white matter lesions (WML), and microbleeds (Mb). Clinically, silent infarcts were defined as new SNCI/LNCCI on follow-up MRI in patients without a clinical stroke or transient ischaemic attack (TIA) during follow-up. Cognition was assessed using validated tests. The mean age was 71 years, 26.1% were females, and 89.9% were anticoagulated. Twenty-eight patients (2.3%) experienced a stroke/TIA during 2 years of follow-up. Of the 68 (5.5%) patients with ≥1 SNCI/LNCCI, 60 (88.2%) were anticoagulated at baseline and 58 (85.3%) had a silent infarct. Patients with brain infarcts had a larger decline in cognition [median (interquartile range)] changes in Cognitive Construct score [-0.12 (-0.22; -0.07)] than patients without new brain infarcts [0.07 (-0.09; 0.25)]. New WML or Mb were not associated with cognitive decline. CONCLUSION: In a contemporary cohort of AF patients, 5.5% had a new brain infarct on MRI after 2 years. The majority of these infarcts was clinically silent and occurred in anticoagulated patients. Clinically, overt and silent brain infarcts had a similar impact on cognitive decline. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02105844, https://clinicaltrials.gov/ct2/show/NCT02105844.


Asunto(s)
Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Infarto Encefálico , Cognición , Estudios de Cohortes , Femenino , Humanos , Ataque Isquémico Transitorio/complicaciones , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/patología
17.
Europace ; 24(7): 1179-1185, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35348646

RESUMEN

Conduction disorders such as left bundle branch block (LBBB) are common after transcatheter aortic valve implantation (TAVI). Consensus regarding a reasonable strategy to manage conduction disturbances after TAVI has been elusive. The European Heart Rhythm Association (EHRA) conducted a survey to capture contemporary clinical practice for conduction disorders after TAVI. A 25-item online questionnaire was developed and distributed among the EHRA electrophysiology (EP) research network centres. Of 117 respondents, 44% were affiliated with university hospitals. A standardized management protocol for advanced conduction disorders such as LBBB or atrioventricular block (AVB) after TAVI was available in 63% of participating centres. Telemetry after TAVI was chosen as the most frequent management strategy for patients with new-onset or pre-existing LBBB (79% and 70%, respectively). Duration of telemetry in patients with new-onset LBBB varied, with a 48-h period being the most frequently chosen, but almost half monitoring continued for at least 72 h. Similarly, in patients undergoing EP study due to new-onset LBBB, the HV interval cut-off point leading to pacemaker implantation was heterogeneous among European centres, although an HV >75 ms threshold was the most common. Conduction system pacing was chosen as a preferred approach by 3.7% of respondents for patients with LBBB and normal left ventricular ejection fraction (LVEF), and by 5.6% for patients with LBBB and reduced LVEF. This survey suggests some heterogenity in the management of conduction disorders after TAVI across European centres. The risk stratification strategies vary substantially. Conduction system pacing in patients with LBBB after TAVI is still underused.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/epidemiología , Trastorno del Sistema de Conducción Cardíaco/terapia , Humanos , Volumen Sistólico , Encuestas y Cuestionarios , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
18.
Europace ; 24(5): 774-783, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34849744

RESUMEN

AIM: The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit. METHODS AND RESULTS: Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes. CONCLUSION: Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Electrocardiografía , Humanos , Prevención Primaria/métodos , Estudios Prospectivos , Factores de Riesgo
19.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-35727739

RESUMEN

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
20.
J Cardiovasc Electrophysiol ; 32(6): 1687-1694, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33825257

RESUMEN

INTRODUCTION: Cardiac resynchronization defibrillator (CRT-D) as primary prevention is known to reduce mortality. At the time of replacement, higher age and comorbidities may attenuate the benefit of implantable cardioverter-defibrillator (ICD) therapy. The purpose of this study was to evaluate the progression of comorbidities after implantation and their association with mortality following CRT-D generator replacement. In addition, a risk score was developed to identify patients at high risk for mortality after replacement. METHODS AND RESULTS: We identified patients implanted with a primary prevention CRT-D (n = 648) who subsequently underwent elective generator replacement (n = 218) from two prospective ICD registries. The cohort consisted of 218 patients (median age: 70 years, male gender: 73%, mean left ventricular ejection fraction [LVEF]: 36 ± 11% at replacement). Median follow-up after the replacement was 4.2 years during which 64 patients (29%) died and 11 patients (5%) received appropriate ICD shocks. An increase in comorbidities was observed in 77 patients (35%). The 5-year mortality rate was 41% in patients with ≥2 comorbidities at the time of replacement. A risk score incorporating age, gender, LVEF, atrial fibrillation, anemia, chronic kidney disease, and history of appropriate ICD shocks at time of replacement accurately predicted 5-year mortality (C-statistic 0.829). Patients with a risk score of greater than 2.5 had excess mortality at 5-year postreplacement compared with patients with a risk score less than 1.5 (57% vs. 6%; p < .001). CONCLUSION: A simple risk score accurately predicts 5-year mortality after replacement in CRT-D patients, as patients with a risk score of greater than 2.5 are at high risk of dying despite ICD protection.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA