Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Swiss Med Wkly ; 147: w14425, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28421570

RESUMEN

BACKGROUND: Based on a reduction in morbidity and mortality, cardiac resynchronisation therapy (CRT) has evolved as a standard therapy for patients with advanced heart failure. OBJECTIVE: To provide insight into patient demographics, safety, echocardiographic remodelling and long-term follow-up of patients treated with CRT in a "real-world" setting at a Swiss tertiary care centre. METHODS: Patients implanted with a CRT device at the University Heart Centre Zurich between 2000 and 2015 were consecutively enrolled. Initial clinical and echocardiographic therapy response as well as long-term follow-up for mortality (defined as all-cause death, heart transplantation or ventricular assist device implantation) and hospitalisation for heart failure were assessed. RESULTS: A total of 418 patients with a median age of 66 years at the time of CRT implantation (78% male) were enrolled. Serious peri-interventional complications (from the time of implantation up to 14 days thereafter) were rare and included systemic infections in 2.4%, pneumothorax in 3.3% and haematoma requiring revision in 2.2% of cases. Overall, the Kaplan-Meier estimate for 5-year freedom from the composite endpoint (hospitalisation for heart failure or mortality) was 55.8%; the Kaplan-Meier estimate for 5-year freedom from mortality was 64.1%. CRT was associated with a significant symptomatic improvement and left ventricular reverse remodelling. Overall, 3.9% of patients did not respond to cardiac resynchronisation therapy (decline in left ventricular ejection fraction [LVEF] >5%), whereas 35.1% experienced neither a continued decline nor a relevant improvement of LVEF (±5%). In the remaining 61% of patients we observed an improvement in LVEF of more than 5%. Forty percent and 31% of patients were super responders, defined as an absolute LVEF improvement of 10% and by a relative reduction of left ventricular end-diastolic volume index by 20% or more. Super-response to CRT was associated with a significant benefit in terms of survival and rehospitalisation rates. CONCLUSION: Our data are consistent with large multicentre trials and indicate that CRT is similarly effective in a real-world setting in Switzerland.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Centros de Atención Terciaria , Anciano , Ecocardiografía , Femenino , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico/fisiología , Suiza , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología , Remodelación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA