Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Radiol ; 18(8): 1577-86, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18369632

RESUMEN

The purpose of this study was to assess the quality of biliary duct visualization using Gd-EOB-DTPA-enhanced magnetic resonance cholangiography (EOB-MRC) in patients with liver cirrhosis. Forty adult patients with liver cirrhosis (cirrhosis group) and 20 adult individuals with normal liver parenchyma (control group) underwent EOB-MRC using T1-weighted GRE imaging up to 180 min after Gd-EOB-DTPA administration. Two observers assessed the visualization of each biliary structure and the overall anatomical visualization of the biliary tree. Child-Pugh, MELD score and laboratory findings were compared. The grade of visualization for each evaluated biliary structure was statistically different in the two groups (P = 0.004 to <0.001). The overall EOB-MRC quality was rated as sufficient for anatomical visualization of the biliary tree in all individuals of the control group 20 min after Gd-EOB-DTPA application, but in only 16/40 patients (40%) of the cirrhosis group within 30 min after application. Analysis of the ROC curves revealed that the cut-off values, for non-sufficient visualization of the biliary tree 20 min after Gd-EOB-DTPA application, were MELD scores > or =11 and total serum bilirubin levels > or =30 micromol/l. Consecutively, EOB-MRC in patients with liver cirrhosis resulted in a decreased or even non-visualization of the biliary tree in a substantial percentage of patients.


Asunto(s)
Conductos Biliares/patología , Pancreatocolangiografía por Resonancia Magnética/métodos , Gadolinio DTPA , Aumento de la Imagen/métodos , Cirrosis Hepática/patología , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Radiology ; 245(1): 276-84, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17717331

RESUMEN

PURPOSE: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using kappa statistics. RESULTS: Overall, the image quality with fast MR angiography was significantly better (P=.001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography (kappa=1.00). CONCLUSION: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection.


Asunto(s)
Angiografía de Substracción Digital , Aorta Abdominal/anatomía & histología , Arteria Ilíaca/anatomía & histología , Angiografía por Resonancia Magnética/métodos , Arteria Renal/anatomía & histología , Adulto , Anciano , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/diagnóstico , Estudios Prospectivos , Obstrucción de la Arteria Renal/diagnóstico , Sensibilidad y Especificidad
3.
Radiology ; 238(2): 586-96, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16436819

RESUMEN

PURPOSE: To prospectively assess feasibility of renal magnetic resonance (MR) perfusion measurement method based on turbo fast low-angle shot sequences for grading effect of renal artery stenosis (RAS) on parenchymal perfusion. MATERIALS AND METHODS: Institutional review board approved this study, and patients gave written consent. Seventy-three patients (34 male, 39 female; age range, 17-84 years) who were clinically suspected of having RAS underwent contrast material-enhanced (gadodiamide) saturation-recovery turbo fast low-angle shot imaging for measurement of renal perfusion and high-spatial-resolution MR angiography for RAS detection and grading. Degree of stenosis was evaluated as high grade (>/=75% stenosis), low to intermediate grade (>0% to <75% stenosis), or absent. High temporal resolution of the turbo fast low-angle shot sequence allowed acquisition of an exact first-pass tracing of the contrast agent bolus from which a signal intensity (SI)-time curve was derived. On the basis of this curve, mean transit time (MTT) of the contrast agent bolus, maximal upslope (MUS) of the curve, maximum SI, and time to SI peak (TTP) were calculated with a gamma variate fit. Wilcoxon rank sum test, Pearson product moment correlation, and paired t test were used for statistical analysis. RESULTS: Twenty-four renal arteries had high-grade RAS, 12 renal arteries had low- to intermediate-grade RAS, and 104 renal arteries had no RAS. Significant differences between patients without stenoses or with low- to intermediate-grade stenoses and patients with high-grade stenoses were found for MTT, MUS, and TTP (P < .001). Perfusion parameters were correlated with patients' serum creatinine levels, and significant correlations were found for MTT (r = 0.41), MUS (r = 0.48), and TTP (r = 0.4), with P < .001. CONCLUSION: MR perfusion parameters can be used to assess effect of RAS on parenchymal perfusion. Perfusion measurements reflect renal function as measured with serum creatinine levels.


Asunto(s)
Imagen por Resonancia Magnética , Obstrucción de la Arteria Renal/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Obstrucción de la Arteria Renal/fisiopatología , Circulación Renal
4.
Radiology ; 236(1): 300-10, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15987982

RESUMEN

The purpose of this study was to integrate parallel acquisition techniques into a comprehensive whole-body cardiovascular screening protocol to image all relevant organ systems without compromising spatial or temporal resolution. The study was approved by the institutional review board, and oral and written informed consent was obtained from each subject. Fifty subjects underwent whole-body magnetic resonance imaging that included imaging of heart, blood vessels, brain, lungs, and abdominal organs with a standard eight-channel imager. Image quality and pathologic findings were evaluated by two readers. The same protocol was then implemented with a new 32-channel whole-body imager. Depiction of 1476 (73.2%) of 2016 vessel segments was rated as good to excellent, and that of 1744 (86.5%), as without venous overlay. Interobserver agreement was good in evaluation of image quality and excellent in evaluation of pathologic findings. Acquisition time was reduced significantly (P < .05) with use of the whole-body imager and parallel acquisition techniques, which provided high-quality fast cardiovascular imaging.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA