Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Biomed Phys Eng ; 12(2): 117-126, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35433519

RESUMEN

Background: Recent research on photon detection has led to the introduction of a silicone photomultiplier (SiPM) that operates at a low voltage and is insensitive to magnetic fields. Objective: This work aims to model a scintillation camera with a SiPM sensor and to evaluate the camera reconstructed images from gamma ray projection data. Material and Methods: The type of study in this research is experimental work and analytical. The scintillation camera, modelled from an SiPM sensor array SL4-30035, coupled with a scintillation material Caesium Iodide doped with Thallium (CsI(Tl)), is used in the experimental part. The performance of the camera was evaluated from reconstructed images by a back-projection technique of a radioactive source Caesium-137 (Cs-137). Results: The experiments conducted with a 1 µCi Cs-137 radioactive source have revealed that the bias voltage (Vbias ) of the SiPM needs to be set to 27.8 V at an operating temperature between 43 °C to 44 °C. The radioactive source has to be placed within a 1 cm distance from the sensor to obtain the optimum projection data. Finally, the back-projection technique for image reconstruction with linear interpolation pre-processing has revealed that the Ram-Lak filter produces a better image contrast ratio compared to others. Conclusion: This research has successfully modelled a scintillation camera with SiPM that was able to reconstruct images with an 86.4% contrast ratio from gamma ray projection data.

2.
Radiat Prot Dosimetry ; 156(2): 246-52, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23538891

RESUMEN

An extensive survey was carried out for gamma dose rates (GDRs) in the Mersing district, Johor, Malaysia. The average value of GDR measured in the district was found to be 140 nGy h(-1), in the range of 40-355 nGy h(-1). The mean weighted dose rate to the population, annual effective dose equivalent, collective effective dose equivalent, lifetime cancer risk were 0.836 mSv y(-1), 0.171 mSv, 1.18 × 10(1) man Sv y(-1) and 6.98 × 10(-4) Sv y, respectively. An isodose map was produced for the district. One way analysis of variance was used to test for differences due to different geological formations present in the Mersing District.


Asunto(s)
Radiación de Fondo , Rayos gamma , Sedimentos Geológicos/análisis , Monitoreo de Radiación , Humanos , Malasia , Modelos Estadísticos , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA