1.
Ann Chim
; 93(1-2): 35-43, 2003.
Artículo
en Inglés
| MEDLINE
| ID: mdl-12650572
RESUMEN
An immobilised Pseudomonas putida cell based biosensor, able to work directly in organic solvent (n-hexane), was designed and built. The response, in n-hexane, to benzene and some of its derivatives was studied. The proposed biosensor was found to be suitable for determining benzene in hydrophobic matrices.