Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Proteome Res ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38713017

RESUMEN

Single-cell proteomics is a powerful approach to precisely profile protein landscapes within individual cells toward a comprehensive understanding of proteomic functions and tissue and cellular states. The inherent challenges associated with limited starting material demand heightened analytical sensitivity. Just as advances in sample preparation maximize the amount of material that makes it from the cell to the mass spectrometer, we strive to maximize the number of ions that make it from ion source to the detector. In isobaric tagging experiments, limited reporter ion generation limits quantitative accuracy and precision. The combination of infrared photoactivation and ion parking circumvents the m/z dependence inherent in HCD, maximizing reporter generation and avoiding unintended degradation of TMT reporter molecules in infrared-tandem mass tags (IR-TMT). The method was applied to single-cell human proteomes using 18-plex TMTpro, resulting in 4-5-fold increases in reporter signal compared to conventional SPS-MS3 approaches. IR-TMT enables faster duty cycles, higher throughput, and increased peptide identification and quantification. Comparative experiments showcase 4-5-fold lower injection times for IR-TMT, providing superior sensitivity without compromising accuracy. In all, IR-TMT enhances the dynamic range of proteomic experiments and is compatible with gas-phase fractionation and real-time searching, promising increased gains in the study of cellular heterogeneity.

2.
Nat Methods ; 17(5): 505-508, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32371966

RESUMEN

Ligands bound to protein assemblies provide critical information for function, yet are often difficult to capture and define. Here we develop a top-down method, 'nativeomics', unifying 'omics' (lipidomics, proteomics, metabolomics) analysis with native mass spectrometry to identify ligands bound to membrane protein assemblies. By maintaining the link between proteins and ligands, we define the lipidome/metabolome in contact with membrane porins and a mitochondrial translocator to discover potential regulators of protein function.


Asunto(s)
Lípidos/análisis , Espectrometría de Masas/métodos , Proteínas de la Membrana/metabolismo , Metaboloma , Proteoma/análisis , Humanos , Ligandos
3.
Angew Chem Int Ed Engl ; 62(36): e202305694, 2023 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-37329506

RESUMEN

Membrane proteins are challenging to analyze by native mass spectrometry (MS) as their hydrophobic nature typically requires stabilization in detergent micelles that are removed prior to analysis via collisional activation. There is however a practical limit to the amount of energy which can be applied, which often precludes subsequent characterization by top-down MS. To overcome this barrier, we have applied a modified Orbitrap Eclipse Tribrid mass spectrometer coupled to an infrared laser within a high-pressure linear ion trap. We show how tuning the intensity and time of incident photons enables liberation of membrane proteins from detergent micelles. Specifically, we relate the ease of micelle removal to the infrared absorption of detergents in both condensed and gas phases. Top-down MS via infrared multiphoton dissociation (IRMPD), results in good sequence coverage enabling unambiguous identification of membrane proteins and their complexes. By contrasting and comparing the fragmentation patterns of the ammonia channel with two class A GPCRs, we identify successive cleavage of adjacent amino acids within transmembrane domains. Using gas-phase molecular dynamics simulations, we show that areas prone to fragmentation maintain aspects of protein structure at increasing temperatures. Altogether, we propose a rationale to explain why and where in the protein fragment ions are generated.


Asunto(s)
Detergentes , Micelas , Espectrometría de Masas/métodos , Proteínas de la Membrana , Receptores Acoplados a Proteínas G
4.
Anal Chem ; 94(9): 3930-3938, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35189062

RESUMEN

Complete LC-MS-based protein primary sequence characterization requires measurement of intact protein profiles under denaturing and/or reducing conditions. To address issues of protein overcharging of unstructured proteins under acidic, denaturing conditions and sample heterogeneity (macro- and micro-scales) which often confound denaturing intact mass analysis of a wide variety of protein samples, we propose the use of broadband isolation of entire charge state distributions of intact proteins followed by ion-ion proton transfer charge reduction, which we have termed "full scan PTCR" (fsPTCR). Using rapid denaturing size exclusion chromatography coupled to fsPTCR-Orbitrap MS and time-resolved deconvolution data analysis, we demonstrate a strategy for method optimization, leading to significant analytical advantages over conventional MS1. Denaturing analysis of the flexible bacterial translation initiation factor 2 (91 kDa) using fsPTCR reduced overcharging and showed an 11-fold gain in S/N compared to conventional MS1. Analysis by fsPTCR-MS of the microheterogeneous glycoprotein fetuin revealed twice as many proteoforms as MS1 (112 vs 56). In a macroheterogeneous mixture of proteins ranging from 14 to 148 kDa, fsPTCR provided more than 10-fold increased sensitivity and quantitative accuracy for diluted bovine serum albumin (66 kDa). Finally, our analysis shows that collisional gas pressure is a key parameter which can be utilized during fsPTCR to retain or remove larger proteins from acquired spectra.


Asunto(s)
Protones , Albúmina Sérica Bovina , Secuencia de Aminoácidos , Cromatografía Liquida/métodos , Espectrometría de Masas , Albúmina Sérica Bovina/química
5.
Anal Chem ; 94(7): 3328-3334, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35142486

RESUMEN

Isobaric tagging facilitates multiplexed experiments that can determine sequences and relative amounts of peptides in biological samples using tandem mass spectrometry (MSn). Limited reporter ion generation limits quantitative accuracy and precision. As reporter ions are susceptible to unintended fragmentation and scattering by high-energy collisions, we activated peptides with IR photons and prevented successive dissociation of generated reporter ions with ion parking, which altogether boosted reporter ion yield by up to 55%. Even so, unintended co-isolation of contaminating peaks in MS2 experiments distorts reporter ion intensities and can distort quantitative information. MS3 experiments address contamination by generating reporter ions via collisional activation (HCD) of one or more peptide product ions rather than the isolated peptide precursor ion. Because HCD performance is related to m/z, activation of multiple synchronously isolated product ions generates less than optimal reporter ion intensities. In this work, we show that using infrared multiphoton dissociation, which is not dependent on m/z, to generate reporter ions from 10 synchronously isolated peptide product ions results in a 2.4-fold increase in reporter ion intensities, significantly enhancing the sensitivity and dynamic range of quantitation via isobaric tagging.


Asunto(s)
Péptidos , Espectrometría de Masas en Tándem , Indicadores y Reactivos , Iones , Péptidos/química , Espectrometría de Masas en Tándem/métodos
6.
Anal Chem ; 93(47): 15728-15735, 2021 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-34788003

RESUMEN

Electron transfer dissociation (ETD) is an analytically useful tool for primary structure interrogation of intact proteins, but its utility is limited by higher-order reactions with the products. To inhibit these higher-order reactions, first-generation fragment ions are kinetically excited by applying an experimentally tailored parallel ion parking waveform during ETD (ETD-PIP). In combination with subsequent ion/ion proton transfer reactions, precursor-to-product conversion was maximized as evidenced by the consumption of more than 90% of the 21 kDa Protein G precursor to form ETD product ions. The employment of ETD-PIP increased sequence coverage to 90% from 80% with standard ETD. Additionally, the inhibition of sequential electron transfers was reflected in the high number of complementary ion pairs from ETD-PIP (90%) compared to standard ETD (39%).


Asunto(s)
Electrones , Proteínas , Transporte de Electrón , Iones , Análisis de Secuencia
7.
Anal Chem ; 92(1): 1041-1049, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-31769661

RESUMEN

Ultraviolet photodissociation (UVPD) produces rich and informative fragmentation of intact protein ions, but in the case of high mass proteins (>30 kDa) the spectra are congested with overlapping isotope patterns of highly charged fragment ions. In the most congested regions, many fragments cannot be confidently identified even when high-resolution mass analyzers and modern deconvolution algorithms are used. Gas-phase ion-ion proton transfer reactions (PTR), which reduce the charge states of highly charged ions, can be used to alleviate this congestion and facilitate the identification of additional fragment ions when performed following UVPD. We have developed protocols for sequentially performing PTR on multiple populations of ions generated by UVPD in a way that can be tailored to balance the depth of characterization with speed and throughput. The improvements in sequence coverage and fragment identifications are demonstrated for four proteins ranging in size from 29 to 56 kDa. Sequence coverages up to 80% were achieved for carbonic anhydrase (29 kDa), 50% for aldolase (39 kDa), 46% for enolase (46 kDa), and 27% for glutamate dehydrogenase (56 kDa), and up to 74% sequence coverage was obtained for 25 kDa antibody drug conjugate subunits in online LC-MS experiments.


Asunto(s)
Enzimas/química , Inmunoconjugados/química , Protones , Secuencia de Aminoácidos , Animales , Bovinos , Cromatografía Liquida/métodos , Enzimas/efectos de la radiación , Inmunoconjugados/efectos de la radiación , Límite de Detección , Proteolisis/efectos de la radiación , Conejos , Saccharomyces cerevisiae/enzimología , Proteínas de Saccharomyces cerevisiae/química , Proteínas de Saccharomyces cerevisiae/efectos de la radiación , Espectrometría de Masas en Tándem/métodos , Rayos Ultravioleta
8.
Anal Chem ; 91(24): 15732-15739, 2019 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-31714757

RESUMEN

Despite the recent technological advances in Fourier transform mass spectrometry (FTMS) instrumentation, top-down proteomics (TDP) is currently mostly applied to the characterization of proteoforms <30 kDa due to the poor performance of high-resolution FTMS for the analysis of larger proteoforms and the high complexity of intact proteomes in the 30-60 kDa mass range. Here, we propose a novel data acquisition method based on ion-ion proton transfer, herein termed proton transfer charge reduction (PTCR), to investigate large proteoforms of Pseudomonas aeruginosa in a high-throughput fashion. We designed a targeted data acquisition strategy, named tPTCR, which applies two consecutive gas phase fractionation steps for obtaining intact precursor masses: first, a narrow (1.5 m/z-wide) quadrupole filter m/z transmission window is used to select a subset of charge states from all ionized proteoform cations; second, this aliquot of protein cations is subjected to PTCR in order to reduce their average charge state: upon m/z analysis in an Orbitrap, proteoform mass spectra with minimal m/z peak overlap and easy-to-interpret charge state distributions are obtained, simplifying the proteoform mass calculation. Subsequently, the same quadrupole-selected narrow m/z region of analytes is subjected to collisional dissociation to obtain proteoform sequence information, which used in combination with intact mass information leads to proteoform identification through an off-line database search. The newly proposed method was benchmarked against the previously developed "medium/high" data-dependent acquisition strategy and doubled the number of UniProt entries and proteoforms >30 kDa identified on the liquid chromatography time scale.


Asunto(s)
Proteínas Bacterianas/metabolismo , Cromatografía Liquida/métodos , Proteoma/análisis , Protones , Pseudomonas aeruginosa/metabolismo , Programas Informáticos , Espectrometría de Masas en Tándem/métodos , Isoformas de Proteínas
9.
Nat Commun ; 15(1): 3259, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627419

RESUMEN

The heterogeneity inherent in today's biotherapeutics, especially as a result of heavy glycosylation, can affect a molecule's safety and efficacy. Characterizing this heterogeneity is crucial for drug development and quality assessment, but existing methods are limited in their ability to analyze intact glycoproteins or other heterogeneous biotherapeutics. Here, we present an approach to the molecular assessment of biotherapeutics that uses proton-transfer charge-reduction with gas-phase fractionation to analyze intact heterogeneous and/or glycosylated proteins by mass spectrometry. The method provides a detailed landscape of the intact molecular weights present in biotherapeutic protein preparations in a single experiment. For glycoproteins in particular, the method may offer insights into glycan composition when coupled with a suitable bioinformatic strategy. We tested the approach on various biotherapeutic molecules, including Fc-fusion, VHH-fusion, and peptide-bound MHC class II complexes to demonstrate efficacy in measuring the proteoform-level diversity of biotherapeutics. Notably, we inferred the glycoform distribution for hundreds of molecular weights for the eight-times glycosylated fusion drug IL22-Fc, enabling correlations between glycoform sub-populations and the drug's pharmacological properties. Our method is broadly applicable and provides a powerful tool to assess the molecular heterogeneity of emerging biotherapeutics.


Asunto(s)
Glicoproteínas , Polisacáridos , Glicosilación , Glicoproteínas/metabolismo , Espectrometría de Masas/métodos , Polisacáridos/metabolismo
10.
Anal Chem ; 85(17): 8385-90, 2013 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-23909443

RESUMEN

Electron transfer dissociation (ETD), a technique that provides efficient fragmentation while depositing little energy into vibrational modes, has been widely integrated into proteomics workflows. Current implementations of this technique, as well as other ion-ion reactions like proton transfer, involve sophisticated hardware, lack robustness, and place severe design limitations on the instruments to which they are attached. Described herein is a novel, electrical discharge-based reagent ion source that is located in the first differentially pumped region of the mass spectrometer. The reagent source was found to produce intense reagent ion signals over extended periods of time while having no measurable impact on precursor ion signal. Further, the source is simple to construct and enables implementation of ETD on any instrument without modification to footprint. Finally, in the context of hybrid mass spectrometers, relocation of the reagent ion source to the front of the mass spectrometer enables new approaches to gas phase interrogation of intact proteins.


Asunto(s)
Transporte de Electrón , Espectrometría de Masa por Ionización de Electrospray/métodos , Iones
11.
Angew Chem Weinheim Bergstr Ger ; 135(36): e202305694, 2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-38516403

RESUMEN

Membrane proteins are challenging to analyze by native mass spectrometry (MS) as their hydrophobic nature typically requires stabilization in detergent micelles that are removed prior to analysis via collisional activation. There is however a practical limit to the amount of energy which can be applied, which often precludes subsequent characterization by top-down MS. To overcome this barrier, we have applied a modified Orbitrap Eclipse Tribrid mass spectrometer coupled to an infrared laser within a high-pressure linear ion trap. We show how tuning the intensity and time of incident photons enables liberation of membrane proteins from detergent micelles. Specifically, we relate the ease of micelle removal to the infrared absorption of detergents in both condensed and gas phases. Top-down MS via infrared multiphoton dissociation (IRMPD), results in good sequence coverage enabling unambiguous identification of membrane proteins and their complexes. By contrasting and comparing the fragmentation patterns of the ammonia channel with two class A GPCRs, we identify successive cleavage of adjacent amino acids within transmembrane domains. Using gas-phase molecular dynamics simulations, we show that areas prone to fragmentation maintain aspects of protein structure at increasing temperatures. Altogether, we propose a rationale to explain why and where in the protein fragment ions are generated.

12.
Anal Chem ; 84(6): 2875-82, 2012 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-22335612

RESUMEN

We describe the first implementation of negative electron-transfer dissociation (NETD) on a hybrid ion trap-orbitrap mass spectrometer and its application to high-throughput sequencing of peptide anions. NETD, coupled with high pH separations, negative electrospray ionization (ESI), and an NETD compatible version of OMSSA, is part of a complete workflow that includes the formation, interrogation, and sequencing of peptide anions. Together these interlocking pieces facilitated the identification of more than 2000 unique peptides from Saccharomyces cerevisiae representing the most comprehensive analysis of peptide anions by tandem mass spectrometry to date. The same S. cerevisiae samples were interrogated using traditional, positive modes of peptide LC-MS/MS analysis (e.g., acidic LC separations, positive ESI, and collision activated dissociation), and the resulting peptide identifications of the different workflows were compared. Due to a decreased flux of peptide anions and a tendency to produce lowly charged precursors, the NETD-based LC-MS/MS workflow was not as sensitive as the positive mode methods. However, the use of NETD readily permits access to underrepresented acidic portions of the proteome by identifying peptides that tend to have lower pI values. As such, NETD improves sequence coverage, filling out the acidic portions of proteins that are often overlooked by the other methods.


Asunto(s)
Proteínas Fúngicas/análisis , Péptidos/análisis , Proteoma/análisis , Proteómica/métodos , Saccharomyces cerevisiae/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Secuencia de Aminoácidos , Cromatografía Liquida/métodos , Concentración de Iones de Hidrógeno , Datos de Secuencia Molecular
13.
J Am Soc Mass Spectrom ; 32(9): 2334-2345, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33900069

RESUMEN

Obtaining extensive sequencing of an intact protein is essential in order to simultaneously determine both the nature and exact localization of chemical and genetic modifications which distinguish different proteoforms arising from the same gene. To effectively achieve such characterization, it is necessary to take advantage of the analytical potential offered by the top-down mass spectrometry approach to protein sequence analysis. However, as a protein increases in size, its gas-phase dissociation produces overlapping, low signal-to-noise fragments. The application of advanced ion dissociation techniques such as electron transfer dissociation (ETD) and ultraviolet photodissociation (UVPD) can improve the sequencing results compared to slow-heating techniques such as collisional dissociation; nonetheless, even ETD- and UVPD-based approaches have thus far fallen short in their capacity to reliably enable extensive sequencing of proteoforms ≥30 kDa. To overcome this issue, we have applied proton transfer charge reduction (PTCR) to limit signal overlap in tandem mass spectra (MS2) produced by ETD (alone or with supplemental ion activation, EThcD). Compared to conventional MS2 experiments, following ETD/EThcD MS2 with PTCR MS3 prior to m/z analysis of deprotonated product ions in the Orbitrap mass analyzer proved beneficial for the identification of additional large protein fragments (≥10 kDa), thus improving the overall sequencing and in particular the coverage of the central portion of all four analyzed proteins spanning from 29 to 56 kDa. Specifically, PTCR-based data acquisition led to 39% sequence coverage for the 56 kDa glutamate dehydrogenase, which was further increased to 44% by combining fragments obtained via HCD followed by PTCR MS3.

14.
Sci Rep ; 11(1): 18309, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-34526615

RESUMEN

Treatment of antibiotic-resistant infections is dependent on the detection of specific bacterial genes or proteins in clinical assays. Identification of methicillin-resistant Staphylococcus aureus (MRSA) is often accomplished through the detection of penicillin-binding protein 2a (PBP2a). With greater dependence on mass spectrometry (MS)-based bacterial identification, complementary efforts to detect resistance have been hindered by the complexity of those proteins responsible. Initial characterization of PBP2a indicates the presence of glycan modifications. To simplify detection, we demonstrate a proof-of-concept tandem MS approach involving the generation of N-terminal PBP2a peptide-like fragments and detection of unique product ions during top-down proteomic sample analyses. This approach was implemented for two PBP2a variants, PBP2amecA and PBP2amecC, and was accurate across a representative panel of MRSA strains with different genetic backgrounds. Additionally, PBP2amecA was successfully detected from clinical isolates using a five-minute liquid chromatographic separation and implementation of this MS detection strategy. Our results highlight the capability of direct MS-based resistance marker detection and potential advantages for implementing these approaches in clinical diagnostics.


Asunto(s)
Proteínas Bacterianas/genética , Staphylococcus aureus Resistente a Meticilina/clasificación , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Staphylococcus aureus Resistente a Meticilina/genética , Proteínas de Unión a las Penicilinas/genética , Infecciones Estafilocócicas/microbiología , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Proteínas Bacterianas/metabolismo , Técnicas de Tipificación Bacteriana , Humanos , Staphylococcus aureus Resistente a Meticilina/metabolismo , Proteínas de Unión a las Penicilinas/metabolismo
15.
Anal Chem ; 82(24): 10068-74, 2010 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-21062032

RESUMEN

Using a modified electron transfer dissociation (ETD)-enabled quadrupole linear ion trap (QLT) mass spectrometer, we demonstrate the utility of IR activation concomitant with ETD ion-ion reactions (activated-ion ETD, AI-ETD). Analyzing 12 strong cation exchanged (SCX) fractions of a LysC digest of human cell protein extract using ETD, collision-activated dissociation (CAD), and AI-ETD, we find that AI-ETD generates 13 405 peptide spectral matches (PSMs) at a 1% false-discovery rate (1% FDR), surpassing both ETD (7 968) and CAD (10 904). We also analyze 12 SCX fractions of a tryptic digest of human cell protein extract and find that ETD produces 6 234 PSMs, AI-ETD 9 130 PSMs, and CAD 15 209 PSMs. Compared to ETD with supplemental collisional activation (ETcaD), AI-ETD generates ∼80% more PSMs for the whole cell lysate digested with trypsin and ∼50% more PSMs for the whole cell lysate digested with LysC.


Asunto(s)
Extractos Celulares/química , Espectrometría de Masas/métodos , Fragmentos de Péptidos/aislamiento & purificación , Humanos , Rayos Infrarrojos , Espectrometría de Masas/instrumentación , Metaloendopeptidasas/metabolismo , Fragmentos de Péptidos/análisis , Proteínas/análisis , Proteínas/metabolismo , Tripsina/metabolismo
16.
J Am Soc Mass Spectrom ; 30(10): 2163-2173, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31392699

RESUMEN

We have enabled parallel ion parking on a modified Orbitrap Elite™ as a way to control ion-ion proton transfer reactions via selective activation of a range of ions. The result is the concentration of the majority of ion current from multiple charge states of each precursor proteoform into a single charge state, maximizing signal intensity and increasing effective sensitivity compared to conventional MS1 spectra. These techniques were applied in an on-line HPLC, data-dependent MS/MS analysis of intact E. coli ribosomal proteins with HCD fragmentation. With one injection, all but two ribosomal proteins were selected for fragmentation and subsequently identified. The techniques described facilitate rapid identification of intact proteins in complex mixtures and an enhanced ability to observe proteins of low abundance.

17.
Biochim Biophys Acta ; 1764(12): 1811-22, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17118725

RESUMEN

Mass spectrometry has played an integral role in the identification of proteins and their post-translational modifications (PTM). However, analysis of some PTMs, such as phosphorylation, sulfonation, and glycosylation, is difficult with collision-activated dissociation (CAD) since the modification is labile and preferentially lost over peptide backbone fragmentation, resulting in little to no peptide sequence information. The presence of multiple basic residues also makes peptides exceptionally difficult to sequence by conventional CAD mass spectrometry. Here we review the utility of electron transfer dissociation (ETD) mass spectrometry for sequence analysis of post-translationally modified and/or highly basic peptides. Phosphorylated, sulfonated, glycosylated, nitrosylated, disulfide bonded, methylated, acetylated, and highly basic peptides have been analyzed by CAD and ETD mass spectrometry. CAD fragmentation typically produced spectra showing limited peptide backbone fragmentation. However, when these peptides were fragmented using ETD, peptide backbone fragmentation produced a complete or almost complete series of ions and thus extensive peptide sequence information. In addition, labile PTMs remained intact. These examples illustrate the utility of ETD as an advantageous tool in proteomic research by readily identifying peptides resistant to analysis by CAD. A further benefit is the ability to analyze larger, non-tryptic peptides, allowing for the detection of multiple PTMs within the context of one another.


Asunto(s)
Espectrometría de Masas/métodos , Procesamiento Proteico-Postraduccional , Proteómica/métodos , Secuencia de Aminoácidos , Disulfuros/química , Transporte de Electrón , Electrones , Glicosilación , Histonas/química , Insulina/química , Datos de Secuencia Molecular , Fosforilación , Análisis de Secuencia de Proteína/métodos , Ácidos Sulfónicos/metabolismo , Espectrometría de Masas en Tándem/métodos , Ubiquitina/química
18.
J Am Soc Mass Spectrom ; 28(7): 1324-1332, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28349437

RESUMEN

Negative mode proteome analysis offers access to unique portions of the proteome and several acidic post-translational modifications; however, traditional collision-based fragmentation methods fail to reliably provide sequence information for peptide anions. Negative electron transfer dissociation (NETD), on the other hand, can sequence precursor anions in a high-throughput manner. Similar to other ion-ion methods, NETD is most efficient with peptides of higher charge state because of the increased electrostatic interaction between reacting molecules. Here we demonstrate that NETD performance for lower charge state precursors can be improved by altering the reagent cation. Specifically, the recombination energy of the NETD reaction-largely dictated by the ionization energy (IE) of the reagent cation-can affect the extent of fragmentation. We compare the NETD reagent cations of C16H10●+ (IE = 7.9 eV) and SF5●+ (IE = 9.6 eV) on a set of standard peptides, concluding that SF5●+ yields greater sequence ion generation. Subsequent proteome-scale nLC-MS/MS experiments comparing C16H10●+ and SF5●+ further supported this outcome: analyses using SF5●+ yielded 4637 peptide spectral matches (PSMs) and 2900 unique peptides, whereas C16H10●+ produced 3563 PSMs and 2231 peptides. The substantive gain in identification power with SF5●+ was largely driven by improved identification of doubly deprotonated precursors, indicating that increased NETD recombination energy can increase product ion yield for low charge density precursors. This work demonstrates that SF5●+ is a viable, if not favorable, reagent cation for NETD, and provides improved fragmentation over the commonly used fluoranthene reagent. Graphical Abstract ᅟ.

19.
J Am Soc Mass Spectrom ; 28(9): 1787-1795, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28721671

RESUMEN

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. Graphical Abstract ᅟ.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/análisis , Proteínas/química , Análisis de Secuencia de Proteína/métodos , Electrones , Diseño de Equipo , Análisis de Fourier , Espectrometría de Masas/instrumentación , Análisis de Secuencia de Proteína/instrumentación , Espectrometría de Masas en Tándem
20.
J Am Soc Mass Spectrom ; 27(3): 520-31, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26589699

RESUMEN

Electron transfer dissociation (ETD) is a valuable tool for protein sequence analysis, especially for the fragmentation of intact proteins. However, low product ion signal-to-noise often requires some degree of signal averaging to achieve high quality MS/MS spectra of intact proteins. Here we describe a new implementation of ETD on the newest generation of quadrupole-Orbitrap-linear ion trap Tribrid, the Orbitrap Fusion Lumos, for improved product ion signal-to-noise via ETD reactions on larger precursor populations. In this new high precursor capacity ETD implementation, precursor cations are accumulated in the center section of the high pressure cell in the dual pressure linear ion trap prior to charge-sign independent trapping, rather than precursor ion sequestration in only the back section as is done for standard ETD. This new scheme increases the charge capacity of the precursor accumulation event, enabling storage of approximately 3-fold more precursor charges. High capacity ETD boosts the number of matching fragments identified in a single MS/MS event, reducing the need for spectral averaging. These improvements in intra-scan dynamic range via reaction of larger precursor populations, which have been previously demonstrated through custom modified hardware, are now available on a commercial platform, offering considerable benefits for intact protein analysis and top down proteomics. In this work, we characterize the advantages of high precursor capacity ETD through studies with myoglobin and carbonic anhydrase.


Asunto(s)
Proteínas/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Algoritmos , Anhidrasas Carbónicas/química , Electrones , Mioglobina/química , Espectrometría de Masas en Tándem/métodos , Ubiquitina/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA