1.
J Synchrotron Radiat ; 27(Pt 3): 762-771, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381779

RESUMEN

This study relates to the INFN project SYRMA-3D for in vivo phase-contrast breast computed tomography using the SYRMEP synchrotron radiation beamline at the ELETTRA facility in Trieste, Italy. This peculiar imaging technique uses a novel dosimetric approach with respect to the standard clinical procedure. In this study, optimization of the acquisition procedure was evaluated in terms of dose delivered to the breast. An offline dose monitoring method was also investigated using radiochromic film dosimetry. Various irradiation geometries have been investigated for scanning the prone patient's pendant breast, simulated by a 14 cm-diameter polymethylmethacrylate cylindrical phantom containing pieces of calibrated radiochromic film type XR-QA2. Films were inserted mid-plane in the phantom, as well as wrapped around its external surface, and irradiated at 38 keV, with an air kerma value that would produce an estimated mean glandular dose of 5 mGy for a 14 cm-diameter 50% glandular breast. Axial scans were performed over a full rotation or over 180°. The results point out that a scheme adopting a stepped rotation irradiation represents the best geometry to optimize the dose distribution to the breast. The feasibility of using a piece of calibrated radiochromic film wrapped around a suitable holder around the breast to monitor the scan dose offline is demonstrated.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Dosimetría por Película , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Italia , Dosis de Radiación , Sincrotrones
2.
J Synchrotron Radiat ; 26(Pt 4): 1343-1353, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274463

RESUMEN

Breast computed tomography (BCT) is an emerging application of X-ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron-radiation phase-contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase-contrast BCT based on the free-space propagation approach is under development. In this paper, full-volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high-resolution CdTe photon-counting detector and the projection data are processed via a phase-retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free-space propagation phase-contrast imaging provide relevant three-dimensional insights of breast morphology at clinically acceptable doses and scan times.


Asunto(s)
Mamografía/métodos , Microscopía de Contraste de Fase/métodos , Microtomografía por Rayos X/métodos , Compuestos de Cadmio/química , Femenino , Humanos , Sincrotrones , Telurio/química
3.
Eur J Appl Physiol ; 118(11): 2443-2454, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30171350

RESUMEN

PURPOSE: Brain hemodynamics is fundamental for the functioning of the human being. Many biophysical factors affect brain circulation, so that a satisfactory understanding of its behavior is challenging. We developed a mathematical model to simulate cerebral and extracerebral flows and pressures in humans. METHODS: The model is composed of an anatomically informed 1-D arterial network, and two 0-D networks of the cerebral circulation and brain drainage, respectively. It takes into account the pulse-wave transmission properties of the 55 main arteries and the main hydraulic and autoregulation mechanisms ensuring blood supply and drainage to the brain. Proper pressure outputs from the arterial 1-D model are used as input to the 0-D models, together with the contribution to venous pressure due to breathing that simulates the drainage effect of the thoracic pump. RESULTS: The model we developed is able to link the arterial tree with the venous pathways devoted to the brain drainage, and to simulate important factors affecting cerebral circulation both for physiological and pathological conditions, such as breathing and hypo/hypercapnia. Finally, the average value of simulated flows and pressures is in agreement with the available experimental data. CONCLUSIONS: The model has the potential to predict important clinical parameters before and after physiological and/or pathological changes.


Asunto(s)
Presión Sanguínea/fisiología , Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Modelos Cardiovasculares , Arterias/fisiología , Simulación por Computador , Humanos
4.
BMC Neurol ; 13: 81, 2013 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-23845008

RESUMEN

BACKGROUND: The quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinical practice. We developed a novel model to calculate the cerebral venous return, normalized to the arterial inflow, in the different segments of the IJV. METHODS: We assessed, by established Echo Colour Doppler (ECD) methodology, the head inflow (HBinF) defined as the sum of common carotids and vertebral arteries, as well as the cerebral flow (CBF) defined as the sum of internal carotid and vertebral arteries. We also assessed the head outflow (HBoutF) defined as the sum of the measurements at the junction of the IJV and the vertebral veins. In addition, we also calculated the collateral flow index (CFI) by estimating the flow which re-enters directly into the superior vena cava as the amount of blood extrapolated by the difference between the HBinF and the HBoutF. We preliminarily tested the model by comparing ten healthy controls (HC) with ten patients affected by chronic cerebral spinal venous insufficiency (CCSVI), a condition characterized by some blockages in the IJV which are bypassed by collateral circulation. RESULTS: In HC the HBinF was 956+-105ml/min, whereas the HBoutF was > 90% of the HBinF, leading to a final CFI value of 1%. The last result shows that a very small amount of blood is drained by the collaterals. In upright we confirmed a reduction of the outflow through the IJV which increased CFI to 9%. When we applied the model to CCSVI, the HBinF was not significantly different from controls. In supine, the flow of CCSVI patients in the IJV junction was significantly lower (p < 0.001) while the correspondent CFI value significantly increased (61%, p < 0.0002). CONCLUSIONS: Our preliminary application of the novel model in the clinical setting suggests the pivotal role of the collateral network in draining the blood into the superior vena cava under CCSVI condition.


Asunto(s)
Encéfalo/irrigación sanguínea , Venas Cerebrales/diagnóstico por imagen , Circulación Colateral/fisiología , Flujo Sanguíneo Regional/fisiología , Ultrasonografía Doppler en Color/métodos , Humanos , Modelos Biológicos , Proyectos Piloto
5.
Phys Med Biol ; 68(14)2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37276869

RESUMEN

Objective.Differentiation of breast tissues is challenging in X-ray imaging because tissues might share similar or even the same linear attenuation coefficientsµ. Spectral computed tomography (CT) allows for more quantitative characterization in terms of tissue density (ρ) and effective atomic number (Zeff) by exploiting the energy dependence ofµ. The objective of this study was to examine the potential ofρ/Zeffdecomposition in spectral breast CT so as to explore the benefits of tissue characterization and improve the diagnostic accuracy of this emerging 3D imaging technique.Approach.In this work, 5 mastectomy samples and a phantom with inserts mimicking breast soft tissues were evaluated in a retrospective study. The samples were imaged at three monochromatic energy levels in the range of 24-38 keV at 5 mGy per scan using a propagation-based phase-contrast setup at SYRMEP beamline at the Italian national synchrotron Elettra.Main results.A custom-made algorithm incorporating CT reconstructions of an arbitrary number of spectral energy channels was developed to extract the density and effective atomic number of adipose, fibro-glandular, pure glandular, tumor, and skin from regions selected by a radiologist.Significance.Preliminary results suggest that, via spectral CT, it is possible to enhance tissue differentiation. It was found that adipose, fibro-glandular and tumorous tissues have average effective atomic numbers (5.94 ± 0.09, 7.03 ± 0.012, and 7.40 ± 0.10) and densities (0.90 ± 0.02, 0.96 ± 0.02, and 1.07 ± 0.03 g cm-3) and can be better distinguished if both quantitative values are observed together.


Asunto(s)
Mastectomía , Tomografía Computarizada por Rayos X , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Imagenología Tridimensional
6.
Materials (Basel) ; 16(10)2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37241435

RESUMEN

The magnetron sputtering technique has been investigated in recent years with ever-growing interest as a verifiable solid target manufacturing technology aimed at the production of medical radionuclides by using low-energy cyclotron accelerators. However, the possible loss of high-cost materials prevents access to work with isotopically enriched metals. The need for expensive materials for the supply of the growing demand for theranostic radionuclides makes the material-saving approach and recovery essential for the radiopharmaceutical field. To overcome the main magnetron sputtering drawback, an alternative configuration is proposed. In this work, an inverted magnetron prototype for the deposition of tens of µm film onto different substrates is developed. Such configuration for solid target manufacturing has been proposed for the first time. Two ZnO depositions (20-30 µm) onto Nb backing were carried out and analysed by SEM (Scanning Electron Microscopy) and XRD (X-ray Diffractogram). Their thermomechanical stability under the proton beam of a medical cyclotron was tested as well. A possible improvement of the prototype and the perspective of its utilisation were discussed.

7.
Med Phys ; 39(9): 5652-63, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22957631

RESUMEN

PURPOSE: Image quality indices based upon model observers are promising alternatives to laborious human readings of contrast-detail images. This is especially appealing in digital mammography as limiting values for contrast thresholds determine, according to some international protocols, the acceptability of these systems in the radiological practice. The objective of the present study was to compare the signal to noise ratios (SNR) obtained with two nonprewhitening matched filter model observer approaches, one in the spatial domain and the other in the frequency domain, and with both of them worked out for disks as present in the CDMAM phantom. METHODS: The analysis was performed using images acquired with the Siemens Novation and Inspiration digital mammography systems. The spatial domain formulation uses a series of high dose CDMAM images as the signal and a routine exposure of two flood images to calculate the covariance matrix. The frequency domain approach uses the mathematical description of a disk and modulation transfer function (MTF) and noise power spectrum (NPS) calculated from images. RESULTS: For both systems most of the SNR values calculated in the frequency domain were in very good agreement with the SNR values calculated in the spatial domain. Both the formulations in the frequency domain and in the spatial domain show a linear relationship between SNR and the diameter of the CDMAM discs. CONCLUSIONS: The results suggest that both formulations of the model observer lead to very similar figures of merit. This is a step forward in the adoption of figures of merit based on NPS and MTF for the acceptance testing of mammography systems.


Asunto(s)
Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Relación Señal-Ruido , Fantasmas de Imagen , Incertidumbre
8.
Diagnostics (Basel) ; 12(10)2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36292096

RESUMEN

The jugular venous pulse (JVP) is a one of the crucial parameters of efficient cardiovascular function. Nowadays, limited data are available regarding the response of JVP to exercise because of its complex and/or invasive assessment procedure. The aim of the present work is to test the feasibility of a non-invasive JVP plethysmography system to monitor different submaximal exercise condition. Twenty (20) healthy subjects (13M/7F mean age 25 ± 3, BMI 21 ± 2) underwent cervical strain-gauge plethysmography, acquired synchronously with the electrocardiogram, while they were carrying out different activities: stand supine, upright, and during the execution of aerobic exercise (2 km walking test) and leg-press machine exercise (submaximal 6 RM test). Peaks a and x of the JVP waveform were investigated since they reflect the volume of cardiac filling. To this aim, the Δax parameter was introduced, representing the amplitude differences between a and x peaks. Significant differences in the values of a, x, and Δax were found between static and exercise conditions (p < 0.0001, p < 0.0001, p < 0.0001), respectively. Particularly, the Δax value for the leg press was approximately three times higher than the supine, and during walking was even nine times higher. The exercise monitoring by means of the novel JVP plethysmography system is feasible during submaximal exercise, and it provides additional parameters on cardiac filling and cerebral venous drainage to the widely used heartbeat rate value.

9.
Diagnostics (Basel) ; 12(9)2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36140512

RESUMEN

The aim of this study was the preliminary assessment of a new cationic contrast agent, the CA4+, via the analysis of spatial distribution in cartilage of ex vivo bovine samples, at micrometer and millimeter scale. Osteochondral plugs (n = 18) extracted from bovine stifle joints (n = 2) were immersed in CA4+ solution up to 26 h. Planar images were acquired at different time points, using a microCT apparatus. The CA4+ distribution in cartilage and saturation time were evaluated. Tibial plates from bovine stifle joints (n = 3) were imaged with CT, before and after 24 h-CA4+ bath immersion, at different concentrations. Afterward, potential CA4+ washout from cartilage was investigated. From microCT acquisitions, the CA4+ distribution differentiated into three distinct layers inside the cartilage, reflecting the spatial distribution of proteoglycans. After 24 h of diffusion, the iodine concentration reached in cartilage was approximately seven times that of the CA4+ bath. The resulting saturation time was 1.9 ± 0.9 h and 2.6 ± 2.9 h for femoral and tibial samples, respectively. Analysis of clinical CT acquisitions confirmed overall contrast enhancement of cartilage after 24 h immersion, observed for each CA4+ concentration. Distinct contrast enhancement was reached in different cartilage regions, depending on tissue's local features. Incomplete but remarkable washout of cartilage was observed. CA4+ significantly improved cartilage visualization and its qualitative analysis.

10.
Eur Radiol ; 21(6): 1207-13, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21193910

RESUMEN

OBJECTIVE: The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investigate the potential of DBT with variable dose distribution by using a phantom in which details of interest are within a heterogeneous background. METHODS: To compare the performance of a commercial digital mammography unit and a DBT prototype, 2D and 3D images of the breast phantom were obtained at similar dose levels. RESULTS: As expected, DBT showed superior performance over digital mammography. Although certain details of interest are not detectable with digital mammography, DBT can reveal their signal by reducing the complexity of tissue structures. Additionally, the potential of the central projection in variable dose DBT is similar to the standard projection obtained with digital mammography. Finally, the uniform and variable dose approaches provided almost identical reconstructed slices. CONCLUSION: This preliminary investigation demonstrates that breast tomosynthesis acquired with variable dose distribution exhibits inherent 3D reconstruction advantages for structure noise removal and provides a 2D projection with a physical image quality close to that of standard mammography.


Asunto(s)
Algoritmos , Neoplasias de la Mama/diagnóstico por imagen , Imagenología Tridimensional/métodos , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Femenino , Humanos , Mamografía/instrumentación , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Sci Rep ; 11(1): 4672, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33633331

RESUMEN

Cardiovascular haemodynamics alters during posture changes and exposure to microgravity. Vascular auto-remodelling observed in subjects living in space environment causes them orthostatic intolerance when they return on Earth. In this study we modelled the human haemodynamics with focus on head and neck exposed to different hydrostatic pressures in supine, upright (head-up tilt), head-down tilt position, and microgravity environment by using a well-developed 1D-0D haemodynamic model. The model consists of two parts that simulates the arterial (1D) and brain-venous (0D) vascular tree. The cardiovascular system is built as a network of hydraulic resistances and capacitances to properly model physiological parameters like total peripheral resistance, and to calculate vascular pressure and the related flow rate at any branch of the tree. The model calculated 30.0 mmHg (30%), 7.1 mmHg (78%), 1.7 mmHg (38%) reduction in mean blood pressure, intracranial pressure and central venous pressure after posture change from supine to upright, respectively. The modelled brain drainage outflow percentage from internal jugular veins is 67% and 26% for supine and upright posture, while for head-down tilt and microgravity is 65% and 72%, respectively. The model confirmed the role of peripheral veins in regional blood redistribution during posture change from supine to upright and microgravity environment as hypothesized in literature. The model is able to reproduce the known haemodynamic effects of hydraulic pressure change and weightlessness. It also provides a virtual laboratory to examine the consequence of a wide range of orthostatic stresses on human haemodynamics.


Asunto(s)
Adaptación Fisiológica , Mareo , Hemodinámica , Ingravidez , Planeta Tierra , Humanos , Presión Hidrostática , Presión Intracraneal/fisiología , Modelos Biológicos
12.
Diagnostics (Basel) ; 11(12)2021 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-34943625

RESUMEN

Cerebral venous outflow is investigated in the diagnosis of heart failure through the monitoring of jugular venous pulse, an indicator to assess cardiovascular diseases. The jugular venous pulse is a weak signal stemming from the lying internal jugular vein and often invasive methodologies requiring surgery are mandatory to detect it. Jugular venous pulse can also be extrapolated via the ultrasound technique, but it requires a qualified healthcare operator to perform the examination. In this work, a wireless, user-friendly, wearable device for plethysmography is developed to investigate the possibility of monitoring the jugular venous pulse non-invasively. The proposed device can monitor the jugular venous pulse and the electrocardiogram synchronously. To study the feasibility of using the proposed device to detect physiological variables, several measurements were carried out on healthy subjects by considering three different postures: supine, sitting, and upright. Data acquired in the experiment were properly filtered to highlight the cardiac oscillation and remove the breathing contribution, which causes a considerable shift in the amplitude of signals. To evaluate the proper functioning of the wearable device for plethysmography, a comparison with the ultrasound technique was carried out. As a satisfactory result, the acquired signals resemble the typical jugular venous pulse waveforms found in literature.

13.
Med Biol Eng Comput ; 59(9): 1889-1899, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34365590

RESUMEN

Accurate and reproducible measurement of blood flow profile is very important in many clinical investigations for diagnosing cardiovascular disorders. Given that many factors could affect human circulation, and several parameters must be set to properly evaluate blood flows with phase-contrast techniques, we developed an MRI-compatible hydrodynamic phantom to simulate different physiological blood flows. The phantom included a programmable hydraulic pump connected to a series of pipes immersed in a solution mimicking human soft tissues, with a blood-mimicking fluid flowing in the pipes. The pump is able to shape and control the flow by driving a piston through a dedicated software. Periodic waveforms are used as input to the pump to move the fluid into the pipes, with synchronization of the MRI sequences to the flow waveforms. A dedicated software is used to extract and analyze flow data from magnitude and phase images. The match between the nominal and the measured flows was assessed, and the scope of phantom variables useful for a reliable calibration of an MRI system was accordingly defined. Results showed that the NO-HYPE phantom is a valuable tool for the assessment of MRI scanners and sequence design for the MR evaluation of blood flows. Overview of the NOvel HYdrodynamic Phantom for the Evaluation of MRI flow measurements (NO-HYPE). Left: internal of the CompuFlow 1000 MR pump unit. Right: Setting of the NO-HYPE before a MRI acquisition session. Soft tissue mimicking material is hosted in the central part of the phantom (light blue chamber). Glass pipes pass through the chamber carrying the blood mimicking fluid.


Asunto(s)
Hidrodinámica , Imagen por Resonancia Magnética , Hemodinámica , Humanos , Fantasmas de Imagen , Programas Informáticos
14.
Eur Radiol Exp ; 4(1): 16, 2020 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-32173785

RESUMEN

BACKGROUND: Congenital vascular disease is one of the leading causes of death in paediatric age. Despite the importance of paediatric haemodynamics, large investigations have been devoted to the evaluation of circulation in adults. The novelty of this study consists in the development of a well calibrated mathematical model of cardiovascular circulation in paediatric subjects. To reach the purpose, a model for adult circulation was modified and recalibrated with experimental data and literature from children to be able to calculate the flow rates and pressures in the brain and neck. METHODS: The haemodynamic model simulates the 76 main arteries, together with the main veins in brain and neck. A proper magnetic resonance imaging (MRI) dataset of 29 volunteers aged 12 ± 5 years (mean ± standard deviation) was used to extract age-dependent physiological and clinical parameters such as heart rate, flow rate, vessel cross section area, and blood pressure. The computational model was calibrated using such experimental data. The paediatric and adult model results were compared. RESULTS: Increase of the vessels stiffness due to aging contributes to a flow rate decrease while blood pressure increases. In accordance, our simulation results show about 16% decrease in mean pressure of internal jugular vein in paediatric rather than adult subjects. The model outcomes indicated about 88% correlation with MRI data. CONCLUSIONS: The mathematical model simulates the paediatric head and neck blood circulation. The model provides detailed information of human haemodynamics including arterial and venous network to study both paediatric and adult blood circulation.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/fisiopatología , Hemodinámica/fisiología , Imagen por Resonancia Magnética/métodos , Adolescente , Envejecimiento/fisiología , Fenómenos Fisiológicos Cardiovasculares , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Modelos Teóricos
15.
Sci Rep ; 10(1): 17430, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-33060795

RESUMEN

Breast Computed Tomography (bCT) is a three-dimensional imaging technique that is raising interest among radiologists as a viable alternative to mammographic planar imaging. In X-rays imaging it would be desirable to maximize the capability of discriminating different tissues, described by the Contrast to Noise Ratio (CNR), while minimizing the dose (i.e. the radiological risk). Both dose and CNR are functions of the X-ray energy. This work aims at experimentally investigating the optimal energy that, at fixed dose, maximizes the CNR between glandular and adipose tissues. Acquisitions of both tissue-equivalent phantoms and actual breast specimens have been performed with the bCT system implemented within the Syrma-3D collaboration at the Syrmep beamline of the Elettra synchrotron (Trieste). The experimental data have been also compared with analytical simulations and the results are in agreement. The CNR is maximized at energies around 26-28 keV. These results are in line with the outcomes of a previously presented simulation study which determined an optimal energy of 28 keV for a large set of breast phantoms with different diameters and glandular fractions. Finally, a study on photon starvation has been carried out to investigate how far the dose can be reduced still having suitable images for diagnostics.


Asunto(s)
Mamografía/métodos , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Simulación por Computador , Femenino , Humanos , Fantasmas de Imagen
16.
Sci Rep ; 9(1): 13135, 2019 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-31511550

RESUMEN

The limits of mammography have led to an increasing interest on possible alternatives such as the breast Computed Tomography (bCT). The common goal of all X-ray imaging techniques is to achieve the optimal contrast resolution, measured through the Contrast to Noise Ratio (CNR), while minimizing the radiological risks, quantified by the dose. Both dose and CNR depend on the energy and the intensity of the X-rays employed for the specific imaging technique. Some attempts to determine an optimal energy for bCT have suggested the range 22 keV-34 keV, some others instead suggested the range 50 keV-60 keV depending on the parameters considered in the study. Recent experimental works, based on the use of monochromatic radiation and breast specimens, show that energies around 32 keV give better image quality respect to setups based on higher energies. In this paper we report a systematic study aiming at defining the range of energies that maximizes the CNR at fixed dose in bCT. The study evaluates several compositions and diameters of the breast and includes various reconstruction algorithms as well as different dose levels. The results show that a good compromise between CNR and dose is obtained using energies around 28 keV.


Asunto(s)
Mama/diagnóstico por imagen , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Fenómenos Biofísicos , Mama/anatomía & histología , Femenino , Humanos , Dosis de Radiación , Relación Señal-Ruido , Rayos X
17.
Sci Rep ; 9(1): 17778, 2019 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-31780707

RESUMEN

In this study we compared the image quality of a synchrotron radiation (SR) breast computed tomography (BCT) system with a clinical BCT in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), noise power spectrum (NPS), spatial resolution and detail visibility. A breast phantom consisting of several slabs of breast-adipose equivalent material with different embedded targets (i.e., masses, fibers and calcifications) was used. Phantom images were acquired using a dedicated BCT system installed at the Radboud University Medical Center (Nijmegen, The Netherlands) and the SR BCT system at the SYRMEP beamline of Elettra SR facility (Trieste, Italy) based on a photon-counting detector. Images with the SR setup were acquired mimicking the clinical BCT conditions (i.e., energy of 30 keV and radiation dose of 6.5 mGy). Images were reconstructed with an isotropic cubic voxel of 273 µm for the clinical BCT, while for the SR setup two phase-retrieval (PhR) kernels (referred to as "smooth" and "sharp") were alternatively applied to each projection before tomographic reconstruction, with voxel size of 57 × 57 × 50 µm3. The CNR for the clinical BCT system can be up to 2-times higher than SR system, while the SNR can be 3-times lower than SR system, when the smooth PhR is used. The peak frequency of the NPS for the SR BCT is 2 to 4-times higher (0.9 mm-1 and 1.4 mm-1 with smooth and sharp PhR, respectively) than the clinical BCT (0.4 mm-1). The spatial resolution (MTF10%) was estimated to be 1.3 lp/mm for the clinical BCT, and 5.0 lp/mm and 6.7 lp/mm for the SR BCT with the smooth and sharp PhR, respectively. The smallest fiber visible in the SR BCT has a diameter of 0.15 mm, while for the clinical BCT is 0.41 mm. Calcification clusters with diameter of 0.13 mm are visible in the SR BCT, while the smallest diameter for the clinical BCT is 0.29 mm. As expected, the image quality of the SR BCT outperforms the clinical BCT system, providing images with higher spatial resolution and SNR, and with finer granularity. Nevertheless, this study assesses the image quality gap quantitatively, giving indications on the benefits associated with SR BCT and providing a benchmarking basis for its clinical implementation. In addition, SR-based studies can provide a gold-standard in terms of achievable image quality, constituting an upper-limit to the potential clinical development of a given technique.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Algoritmos , Femenino , Humanos , Mamografía/instrumentación , Fantasmas de Imagen , Relación Señal-Ruido , Sincrotrones/instrumentación , Tomografía Computarizada por Rayos X/instrumentación
18.
J Med Imaging (Bellingham) ; 6(3): 031402, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30525064

RESUMEN

A program devoted to performing the first in vivo synchrotron radiation (SR) breast computed tomography (BCT) is ongoing at the Elettra facility. Using the high spatial coherence of SR, phase-contrast (PhC) imaging techniques can be used. The latest high-resolution BCT acquisitions of breast specimens, obtained with the propagation-based PhC approach, are herein presented as part of the SYRMA-3D collaboration effort toward the clinical exam. Images are acquired with a 60 - µ m pixel dead-time-free single-photon-counting CdTe detector. The samples are imaged at 32 and 38 keV in a continuous rotating mode, delivering 5 to 20 mGy of mean glandular dose. Contrast-to-noise ratio (CNR) and spatial resolution performances are evaluated for both PhC and phase-retrieved images, showing that by applying the phase-retrieval algorithm a five-time CNR increase can be obtained with a minor loss in spatial resolution across soft tissue interfaces. It is shown that, despite having a poorer CNR, PhC images can provide a sharper visualization of microcalcifications, thus being complementary to phase-retrieved images. Furthermore, the first full-volume scan of a mastectomy sample ( 9 × 9 × 3 cm 3 ) is reported. This investigation into surgical specimens indicates that SR BCT in terms of CNR, spatial resolution, scan duration, and scan volume is feasible.

19.
Phys Med Biol ; 64(15): 155011, 2019 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-31234148

RESUMEN

A quantitative characterization of the soft tissues composing the human breast is achieved by means of a monochromatic CT phase-contrast imaging system, through accurate measurements of their attenuation coefficients within the energy range of interest for breast CT clinical examinations. Quantitative measurements of linear attenuation coefficients are performed on tomographic reconstructions of surgical samples, using monochromatic x-ray beams from a synchrotron source and a free space propagation setup. An online calibration is performed on the obtained reconstructions, in order to reassess the validity of the standard calibration procedure of the CT scanner. Three types of healthy tissues (adipose, glandular, and skin) and malignant tumors, when present, are considered from each sample. The measured attenuation coefficients are in very good agreement with the outcomes of similar studies available in the literature, although they span an energy range that was mostly neglected in the previous studies. No globally significant differences are observed between healthy and malignant dense tissues, although the number of considered samples does not appear sufficient to address the issue of a quantitative differentiation of tumors. The study assesses the viability of the proposed methodology for the measurement of linear attenuation coefficients, and provides a denser sampling of attenuation data in the energy range useful to breast CT.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Mama/patología , Femenino , Humanos , Sincrotrones , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X/instrumentación
20.
Phys Med ; 45 Suppl 1: S2-S3, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29413851

RESUMEN

Advanced applications of digital mammography such as dual-energy and tomosynthesis require multiple exposures and thus deliver higher dose compared to standard mammograms. A straightforward manner to reduce patient dose without affecting image quality would be removal of the anti-scatter grid, provided that the involved reconstruction algorithms are able to take the scatter figure into account [1]. Monte Carlo simulations are very well suited for the calculation of X-ray scatter distribution and can be used to integrate such information within the reconstruction software. Geant4 is an open source C++ particle tracking code widely used in several physical fields, including medical physics [2,3]. However, the coherent scattering cross section used by the standard Geant4 code does not take into account the influence of molecular interference. According to the independent atomic scattering approximation (the so-called free-atom model), coherent radiation is indistinguishable from primary radiation because its angular distribution is peaked in the forward direction. Since interference effects occur between x-rays scattered by neighbouring atoms in matter, it was shown experimentally that the scatter distribution is affected by the molecular structure of the target, even in amorphous materials. The most important consequence is that the coherent scatter distribution is not peaked in the forward direction, and the position of the maximum is strongly material-dependent [4]. In this contribution, we present the implementation of a method to take into account inter-atomic interference in small-angle coherent scattering in Geant4, including a dedicated data set of suitable molecular form factor values for several materials of clinical interest. Furthermore, we present scatter images of simple geometric phantoms in which the Rayleigh contribution is rigorously evaluated.