1.
Kyobu Geka ; 69(12): 995-998, 2016 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-27821823

RESUMEN

In off-pump coronary artery bypass grafting(OPCAB), a bloodless operative field has great influence on the quality of anastomosis. In addition, maintenance of distal coronary flow during anastomosis stabilizes hemodynamics. We introduced a new intracoronary shunt cannula, Mini Shunt Pro (MSP). MSP adopts the step-tip, which allows easy insertion and reduces the risk of intimal injury. The distal and proximal sides of the tips of MSP are 0.25 mm different in diameter, which improves its fitness to the coronary artery and enhances a bloodless operative field. This new shunt cannula is considered to be safe and useful for high-quality anastomosis in OPCAB.


Asunto(s)
Cánula , Puente de Arteria Coronaria Off-Pump/instrumentación , Puente de Arteria Coronaria Off-Pump/métodos , Vasos Coronarios/cirugía , Humanos
2.
Surg Today ; 45(9): 1153-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25366352

RESUMEN

PURPOSE: The saline injection test is commonly employed during mitral valvuloplasty. However, discrepancies in regurgitation between the naked eye findings during the saline injection test and the postoperative echocardiographic findings have been noted. Here, we describe the new retrograde cardio-protective beating test (RC-beating test) which allows direct transatrial evaluation of the valve in the fully loaded, beating heart under cross-clamping by means of the retrograde perfusion of warm oxygenated blood into the coronary sinus. METHODS: From January 2006 to June 2012, 63 patients (mean age, 59 ± 15 years) with degenerative mitral valve regurgitation underwent mitral valve repair with application of this novel evaluation. RESULTS: In 20 of the 63 patients (31.8%), minor residual leaks that were not remarkable in the saline injection test were detected during the RC-beating test and were completely corrected. Almost all patients (n = 61, 96.8%) revealed no mitral regurgitation on intraoperative transesophageal echocardiography. The results of the RC-beating test were satisfactory, and discrepancies were not recognized at all between this evaluation and the postoperative echocardiographic findings. The ultrastructure of the mitochondria showed significant myocardial preservation. CONCLUSION: The RC-beating test is a simpler and more accurate evaluation for mitral valve repair than the saline injection test. This novel evaluation enables a safe and more complete mitral valve repair.


Asunto(s)
Pruebas de Función Cardíaca/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Monitoreo Intraoperatorio/métodos , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anuloplastia de la Válvula Mitral/métodos , Cloruro de Sodio , Instrumentos Quirúrgicos , Adulto Joven
3.
Kyobu Geka ; 68(12): 985-9, 2015 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-26555912

RESUMEN

This report describes a case in which we treated a patient who developed infective endocarditis in the mitral valve at 28 weeks' gestation. The condition was resolved by performing mitral valvuloplasty 2 days after an emergency cesarean section. Although the patient was in a relatively stable period at 32 weeks' gestation, the mother had an extremely high risk of embolism;thus, emergency surgery was required. We believe that an accurate diagnosis in a timely manner and a valvuloplasty shortly after cesarean section saved the life of the mother and child.


Asunto(s)
Endocarditis Bacteriana/cirugía , Anuloplastia de la Válvula Mitral/métodos , Válvula Mitral/cirugía , Complicaciones Cardiovasculares del Embarazo/cirugía , Adulto , Cesárea , Femenino , Humanos , Embarazo , Resultado del Embarazo
4.
Kyobu Geka ; 67(10): 888-90, 2014 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-25201364

RESUMEN

Intraoperative evaluation is important for successful mitral valve plasty (MVP). We performed a saline injection test and a retrograde cardioprotective beating test (RC-beating test) for intraoperative evaluation. The concept of the RC- beating test is evaluation of residual mitral valve regurgitation( MR) under cardiac beating. A 66-year-old man with severe MR underwent MVP. The P3 chorda was ruptured and we performed quadrangular resection. The saline injection test showed trivial regurgitation. We then performed the RC-beating test and it revealed severe leakage from the posterior commissure(PC). Since the PC had a sclerotic change, another quadrangular resection was performed. Moreover,as the anterior leaflet( A3) was slightly elongated, the region was resected in an obtuse-angled triangle shape and repaired by suturing the edges. The final RC-beating test showed no residual leakage. The RC-beating test is useful for detecting residual mitral valve leakage.


Asunto(s)
Cardiopatías/fisiopatología , Válvula Mitral/cirugía , Anciano , Cardiopatías/cirugía , Humanos , Masculino
5.
Electrophoresis ; 34(17): 2464-72, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23801451

RESUMEN

A new fluorescent molecular probe, methyl 3-(3,5-bis((bis(pyridin-2-ylmethyl)amino)-methyl)-4-hydroxyphenyl)-2-(5-(dimethylamino)naphthalene-1-sulfonamido) propanoate, dizinc(II) chloride salt (Dansyl-1-Zn(II)), which possesses Zn(II) complexes and a dansyl group, was designed and synthesized to enable the detection of proteins in solution and in high-throughput electrophoresis by using a UV-based detection system. Dansyl-1-Zn(II) exhibited weak fluorescence in the absence of proteins and strong green fluorescence at approximately 510 nm in the presence of BSA upon irradiation with light at a wavelength of 345 nm. Compared with conventional protocols for in-gel SDS-PAGE protein staining (e.g. silver staining, SYPRO Ruby, and Oriole), the operating times of which range from 90 min to overnight, Dansyl-1-Zn(II) allowed 1-step protein staining (SDS-PAGE →Staining →Detection) and shortened the operating time (35 min) with high sensitivity (LOD: 1 ng or less) under 312-nm or 365-nm light excitation with orange or red emission filters, respectively. Moreover, Dansyl-1-Zn(II) was successfully applied to protein identification by MS via in-gel tryptic digestion, Western blotting, and Native-PAGE. Accordingly, Dansyl-1-Zn(II) may facilitate highly sensitive and high-throughput protein detection, and it may be widely applicable as a convenient tool in various scientific and medical fields.


Asunto(s)
Colorantes Fluorescentes/química , Sondas Moleculares/química , Proteínas/análisis , Proteómica/métodos , Espectrometría de Fluorescencia/métodos , Animales , Electroforesis en Gel Bidimensional , Ensayos Analíticos de Alto Rendimiento , Hígado/química , Espectrometría de Masas , Ratones , Proteínas/química , Proteínas/metabolismo
6.
Kyobu Geka ; 66(3): 187-9, 2013 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-23445641

RESUMEN

A 76-year-old female was hospitalized because of congestive heart failure and anemia. A thorough examination led to a diagnosis of severe aortic stenosis and cold agglutinin disease. The critical temperature for hemagglutination was 27 °C, which caused particular problems with regard to the myocardial protection temperature during surgery. Aortic valve replacement was performed safely by increasing the normal myocardial protection temperature from 15 °C to 32 °C and using 3 times the normal volume of cardioplagic fluid. As a result of strict perioperative thermal management, the operation was completed without any complications.


Asunto(s)
Anemia Hemolítica Autoinmune/complicaciones , Válvula Aórtica/cirugía , Paro Cardíaco Inducido/métodos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos
7.
Kyobu Geka ; 65(6): 500-2, 2012 Jun.
Artículo en Japonés | MEDLINE | ID: mdl-22647335

RESUMEN

Long-term durability and stability of the hemodynamic performance of commercially available 2nd generation Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount valve) is reported based on echocardiographic follow-up examinations. Prosthetic valve deterioration of the Perimount valve usually occurs late and is age-dependent. We describe bioprosthetic valve deterioration of a Perimount valve with severe stenotic change 1 month postoperatively that developed in an infective endocarditis patient. Although preoperative echocardiography showed no signs of valve dehiscence or vegetation on the prosthesis, valve stenosis alone had progressed extremely rapidly during 2 weeks of febrile symptom. The valve leaflet was found at explant to be infiltrated with a cellular material fibrin other than bacteria or leukocytes. This rare occurrence needs to be reported in the literature to forewarn clinicians of an early manifestation of endocarditis that may not be recognized yet.


Asunto(s)
Estenosis de la Válvula Aórtica/etiología , Bioprótesis/efectos adversos , Infecciones Relacionadas con Prótesis , Anciano , Insuficiencia de la Válvula Aórtica/cirugía , Ecocardiografía , Endocarditis/etiología , Femenino , Humanos , Infecciones Relacionadas con Prótesis/complicaciones
8.
Kyobu Geka ; 65(2): 98-102, 2012 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-22314162

RESUMEN

A 61-year-old man with acute myocardial infarction underwent percutaneous coronary intervention with stent for the left main coronary artery (LMT) and the left anterior descending artery (LAD). Three months later, we recognized the LMT aneurysm complicated with possible thrombus formation, which developed in size during 6 months. In addition, the LAD stent showed significant in-stent stenosis. For the purpose of supplying blood flow to the distal of LAD, and avoiding myocardial infarction due to distal thrombosis possibly originated from LMT aneurysm, we decided to perform surgical operation. On preoperative examination, this patient had an obstruction of the right internal carotid artery. Although the direct repair of LMT aneurysm requires conventional approach with cardiopulmonary bypass, we applied off-pump coronary artery bypass grafting( OPCAB) considering the risk of cerebrovascular event. Consequently, OPCAB was performed in usual fashion [right internal thoracic artery (RITA) -LAD, left internal thoracic artery-left circumflex artery (LITA-LCX)] followed by the ligation of the proximal of LAD and LCX without cardiopulmonary bypass. The patient had a good operative course.


Asunto(s)
Aneurisma Coronario/cirugía , Infarto del Miocardio/terapia , Stents , Vasos Coronarios , Humanos , Masculino , Persona de Mediana Edad
9.
Electrophoresis ; 32(12): 1403-13, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21692079

RESUMEN

A new fluorescent molecular probe, 2,2'-(1E,1'E)-2,2'-(4-(dicyanomethylene)-4H-pyrane-2,6-diyl)bis(ethene-2,1-diyl)bis(sodium benzenesulfonate) salt (1), possessing the cyanopyranyl moieties and two benzene sulfonic acid groups was designed and synthesized to detect proteins in solution and for high-throughput SDS-PAGE. Compound 1 exhibited no fluorescence in the absence of proteins; however, it exhibited strong fluorescence on the addition of bovine serum albumin as a result of intramolecular charge transfer. Compared with the conventional protocols for in-gel protein staining, such as SYPRO Ruby and silver staining, 1 achieves higher sensitivity, even though it offers a simplified, higher throughput protocol. In fact, the total time required for protein staining was 60-90 min under optimum conditions much shorter than that required by the less-sensitive silver staining or SYPRO Ruby staining protocols. Moreover, 1 was successfully applied to protein identification by mass spectrometry via in-gel tryptic digestion, Western blotting, and native PAGE together with protein staining by 1, which is a modified protocol of blue native PAGE (BN-PAGE). Thus, 1 may facilitate high-sensitivity protein detection, and it may be widely applicable as a convenient tool in various scientific and medical fields.


Asunto(s)
Electroforesis en Gel de Poliacrilamida/métodos , Colorantes Fluorescentes/química , Animales , Bencenosulfonatos/síntesis química , Bencenosulfonatos/química , Western Blotting , Bovinos , Colorantes Fluorescentes/síntesis química , Compuestos Organometálicos/química , Fragmentos de Péptidos/química , Fragmentos de Péptidos/aislamiento & purificación , Proteínas/química , Proteínas/aislamiento & purificación , Sensibilidad y Especificidad , Albúmina Sérica Bovina/química , Albúmina Sérica Bovina/aislamiento & purificación , Tinción con Nitrato de Plata , Espectrometría de Fluorescencia , Tripsina/química
10.
J Artif Organs ; 14(4): 289-93, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21735151

RESUMEN

The aim of this study was to investigate the effects of pressure load (pulmonary arterial pressure) on the long-term durability of second-generation xenobioprostheses in the pulmonary position in young adults. Thirteen patients survived pulmonary valve replacement for pulmonary regurgitation using the second-generation aortic porcine bioprosthesis at Sapporo Medical University School of Medicine between 1985 and 2009. The mean age at pulmonary valve replacement was 40.5 years, and the mean prosthetic valve size was 25.3 mm. Two patients developed structural valve deterioration 6 and 9 years, respectively, after pulmonary valve replacement. Both prosthetic valves with structural valve deterioration were subjected to long-term high levels of pressure load. No valve structural failure was observed in the remaining 11 patients who experience low-pressure load during a mean follow-up period of 11.9 years. The freedom from structural valve deterioration at 15 years was 75.8% for the overall population, but 100% for those with low-pressure load. Our findings suggest that the long-term durability of pulmonary-site bioprosthetic valves in young adult patients is promising but that pressure load might be a risk of the limited durability of the valve.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Presión , Falla de Prótesis , Válvula Pulmonar , Adulto , Animales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Porcinos , Adulto Joven
12.
Biol Open ; 8(7)2019 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-31182631

RESUMEN

Differentiation of stem cells to hepatocytes provides an unlimited supply of human hepatocytes and therefore has been vigorously studied. However, to date, the stem cell-derived hepatocytes were suggested to be of immature features. To obtain matured hepatocytes from stem cells, we tested the effect of culturing human-induced pluripotent stem (hiPS) cell-derived endoderm cells on collagen vitrigel membrane and compared with our previous reported nanofiber matrix. We cultured hiPS cell-derived endoderm cells on a collagen vitrigel membrane and examined the expression profiles, and tested the activity of metabolic enzymes. Gene expression profile analysis of hepatocytic differentiation markers revealed that upon culture on collagen vitrigel membrane, immature markers of AFP decreased, with a concomitant increase in the expression of mature hepatocyte transcription factors and mature hepatocyte markers such as ALB, ASGR1 Mature markers involved in liver functions, such as transporters, cytochrome P450 enzymes and phase II metabolic enzymes were also upregulated. We observed the upregulation of the liver markers for at least 2 weeks. Gene array profiling analysis revealed that hiPS cell-derived hepatocyte-like cells (hiPS-hep) resemble those of the primary hepatocytes. Functions of the CYP enzyme activities were tested in multi-institution and all revealed high CYP1A, CYP2C19, CYP2D6, CYP3A activity, which could be maintained for at least 2 weeks in culture. Taken together, the present approach identified that collagen vitrigel membrane provides a suitable environment for the generation of hepatocytes from hiPS cells that resemble many characteristics of primary human hepatocytes.

13.
Sensors (Basel) ; 7(12): 3058-3070, 2007 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-28903279

RESUMEN

A system for remotely measuring the distribution of air space charge in real time is developed. The system consists of a loudspeaker and an electric field antenna. By propagating a burst of directional sound wave from the speaker, a modulation in the space charge and, therefore, an electric field change at ground is produced. The distribution of the space charge density is derived from the E-field change which can be measured by the E- field antenna. The developed system has been confirmed by both laboratory and field experiments.

14.
J Vet Med Sci ; 79(3): 626-631, 2017 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-28163273

RESUMEN

The main factors affecting the outcome of Trueperella pyogenes (T. pyogenes) mastitis were examined through a survey of diagnostic data and interviews relating to the occurrence of T. pyogenes mastitis in 83 quarters from 82 Holstein cows between August 2012 and April 2014. Ultimately, one cow was sold during the examination, and 82 quarters from 81 cows were used for analysis on prognosis. T. pyogenes mastitis occurred year round in both lactating and dry cows. The incidence of T. pyogenes mastitis did not significantly differ by month or show seasonality in either lactating or dry cows. Therefore, the occurrence of T. pyogenes mastitis also differed from that of summer mastitis. The 1-month survival rate of infected cows was 64.6% (53/82), and the recovery rate of quarters with T. pyogenes mastitis was 14.6% (12/82). Bivariate logistic regression analysis was performed with survival and culling of infected cows as objective variables and with recovery and non-recovery of quarters with T. pyogenes mastitis as objective variables. The severe cases were significantly culled (odds ratio, 16.30) compared to mild cases, and the status of quarters didn't recover (odds ratio, 6.50). The results suggest that mild to moderate symptom severity at the time of onset are the main factors affecting outcomes in cows and recovery of quarters infected with T. pyogenes mastitis. Further, high level of NAGase activity also suggested the potential use as an indicator of culling of cows with T. pyogenes mastitis.


Asunto(s)
Actinomycetaceae/aislamiento & purificación , Infecciones por Actinomycetales/veterinaria , Mastitis Bovina/epidemiología , Mastitis Bovina/microbiología , Infecciones por Actinomycetales/epidemiología , Animales , Bovinos , Industria Lechera/métodos , Industria Lechera/estadística & datos numéricos , Femenino , Hexosaminidasas/análisis , Incidencia , Japón , Lactancia , Leche/enzimología , Leche/microbiología , Estaciones del Año
15.
J Thorac Cardiovasc Surg ; 151(6): 1704-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26971376

RESUMEN

OBJECTIVE: In this study, we compared the histologic and morphometric properties of both internal thoracic arteries and the right gastroepiploic artery (GEA) in patients undergoing coronary artery bypass grafting (CABG). METHODS: We microscopically examined transverse sections of segments of both internal thoracic arteries and the right GEA obtained from 83 consecutive patients who underwent CABG. RESULTS: There were no significant differences between the internal thoracic arteries. Significant differences were found between the left and right internal thoracic arteries and GEA in the intimal width (21.8, 21.5, and 71.7 µm, respectively; P < .01), intima-to-media ratio (0.286, 0.256, and 0.749, respectively; P < .01), and media width (148.5, 157.5, and 164.8 µm, respectively; P = .43). No atherosclerotic lesions, medial calcification, or intimal thickening were seen in the internal thoracic arteries; however, atherosclerotic lesions were seen in the GEA. The intima of the GEA was thicker than that of the internal thoracic arteries. Intimal thickening of the GEA, but not the internal thoracic arteries, was positively correlated with risk of arteriosclerosis. In patients with diabetes mellitus, dietary/drug therapy and insulin therapy were associated with GEA intimal thickness (P = .02 and .01, respectively). CONCLUSIONS: The internal thoracic arteries have equivalent histologic and morphometric properties that differ from those of the GEA only in intimal width. The former had no intimal thickening, and is thus preferable to the GEA for CABG.


Asunto(s)
Aterosclerosis/patología , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Endotelio Vascular/patología , Arteria Gastroepiploica/trasplante , Arterias Mamarias/trasplante , Complicaciones Posoperatorias/patología , Anciano , Femenino , Estudios de Seguimiento , Arteria Gastroepiploica/patología , Humanos , Hiperplasia , Masculino , Arterias Mamarias/patología , Estudios Retrospectivos , Factores de Riesgo , Túnica Íntima/patología
16.
J Med Ultrason (2001) ; 43(1): 91-4, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26703172

RESUMEN

We report a case of unroofed coronary sinus (URCS) in a 42-year-old female. At an outpatient clinic, she was found to have an atrioventricular septal defect and mitral regurgitation with pulmonary hypertension, and she was transferred to our institute for surgical treatment. Both atrioventricular valves were located at the same level, and both the right atrium (RA) and right ventricle were enlarged on two-dimensional transthoracic echocardiography. Color Doppler imaging demonstrated severe mitral and tricuspid regurgitation and a left-to-right shunt from the left atrium (LA) to the RA. Although an ostium primum defect of the atrial septum was suspected, the exact position of the shunt flow was unclear. Two-dimensional transesophageal echocardiography (2D-TEE) could visualize a direct communication between the LA and coronary sinus. Three-dimensional transesophageal echocardiography (3D-TEE) clearly visualized the entire route from the coronary sinus into the LA and RA. The utility of 3D-TEE as a modality complementary to 2D-TEE in diagnosis of URCS was confirmed.


Asunto(s)
Seno Coronario/anomalías , Seno Coronario/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Adulto , Seno Coronario/cirugía , Ecocardiografía Doppler en Color/métodos , Femenino , Humanos
17.
Nihon Geka Gakkai Zasshi ; 106(5): 334-7, 2005 May.
Artículo en Japonés | MEDLINE | ID: mdl-15934550

RESUMEN

Untreated or palliated congenital heart disease has the strong impact on the outcomes of surgery for non-cardiovascular disease that accrues with age. However, excellent guidelines have not been published yet that provide ideal information and expert opinion for patients and doctors in assessing adult congenital heart disease (ACHD). In the global risk assessment for such a condition, American College of Cardiology--American Heart Association (ACC/AHA) guidelines can be helpful although developed exclusively from populations with acquired heart disease. The first necessity is to clarify the diagnosis The second is preoperative hemodynamic assessment according to the specific physiology and anatomy. The third is to evaluate the intensity of expected hemodynamic stress by proposed operation. The last is to elucidate co-morbid conditions. In addition to global risk assessment, Risk factors unique to ACHD must be carefully considered. Under complete assessment of these risk factors by the staff who have sufficient experience or training in the management of ACHD, the optimal, effective and meticurous cares can be provided to patients with ACHD encountered at noncardiac surgery.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Atención Perioperativa , Procedimientos Quirúrgicos Operativos , Adulto , Comorbilidad , Cardiopatías Congénitas/fisiopatología , Hemodinámica , Humanos , Monitoreo Intraoperatorio , Guías de Práctica Clínica como Asunto , Medición de Riesgo , Factores de Riesgo
19.
Eur J Cardiothorac Surg ; 47(3): 459-63, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24878578

RESUMEN

OBJECTIVES: The objective of this study was to analyse the relationship between the intraoperative transit-time flow measurement (TTFM) parameter values and the postoperative angiographic results of gastroepiploic arterial (GEA) grafts to the right coronary artery (RCA). We investigated whether the intraoperative TTFM parameter values are reliable indicators of early patency in GEA grafts to the RCA. METHODS: Patients undergoing off-pump coronary artery bypass surgery with GEA grafts were included in this study. Eighty-three GEA grafts were individually anastomosed and examined by angiography 1 week after surgery. The quality of each graft was graded using FitzGibbon grading (Study 1) and graft-flow grading (Study 2). RESULTS: Study 1: Seventy-two grafts were determined as Grade A and 11 as Grades B or O. There were no significant differences in the average of mean graft flow (MGF), pulsatility index or diastolic filling percentage between Grade A and Grades B or O grafts. Study 2: Sixty-two grafts were graded as good-graft dominant, 16 as bidirectional and 5 as occlusion including string. The average of the MGF, pulsatility index and diastolic filling percentage in the grafts graded as bidirectional and occlusion including string were not significantly different from those of grafts graded as good-graft dominant. CONCLUSIONS: Previously reported cut-off values for intraoperative TTFM parameters could not be adapted for the early patency of GEA grafts to the RCA. However, the smoothness of the graft-flow curve may be a reliable predictor of postoperative graft patency.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/cirugía , Arteria Gastroepiploica/cirugía , Arteria Gastroepiploica/trasplante , Velocidad del Flujo Sanguíneo , Puente de Arteria Coronaria Off-Pump/efectos adversos , Electrocardiografía , Humanos , Flujo Sanguíneo Regional
20.
Eur J Cardiothorac Surg ; 48(6): 887-92, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25827688

RESUMEN

OBJECTIVES: Transit-time flow measurement (TTFM) parameters such as mean graft flow (MGF, ml/min), pulsatility index (PI) and diastolic filling (DF, %) have been extensively researched for internal mammary arterial or saphenous vein grafts. In our experience of using the right gastroepiploic arterial (GEA) graft for right coronary artery (RCA) grafting, we observed unique GEA graft flow waveforms. We analysed the GEA graft flow waveforms for their effectiveness in determining GEA graft patency by power spectral analysis. METHODS: Forty-five patients underwent off-pump coronary artery bypass using the GEA graft for RCA grafting individually. The means of intraoperative MGF, PI and DF were compared between patent and non-patent grafts, postoperatively. Furthermore, the GEA flow data were output and analysed using power spectral analysis. RESULTS: Forty grafts were 'patent' and five were 'non-patent'. There were no significant differences in the mean TTFM parameters between the patent and non-patent grafts (MGF: 22 vs 8 ml/min, respectively, P = 0.068; PI: 3.5 vs 6.5, respectively, P = 0.155; DF: 63 vs 53%, respectively, P = 0.237). Results of the power spectral analysis presented clear differences; the power spectral density (PSD) of patent grafts presented high peaks at frequency levels of 1, 2 and 3 Hz, and the non-patent graft PSD presented high peaks that were not limited to these frequencies. The PSD had a sensitivity and specificity of 80 and 87.5%, respectively. CONCLUSIONS: Power spectral analysis of the GEA graft flow is useful to distinguish between non-patent and patent grafts intraoperatively. This should be used as a fourth parameter along with MGF, PI and DF.


Asunto(s)
Arteria Gastroepiploica/cirugía , Monitoreo Fisiológico/métodos , Injerto Vascular/métodos , Grado de Desobstrucción Vascular , Anciano , Velocidad del Flujo Sanguíneo , Puente de Arteria Coronaria/métodos , Interpretación Estadística de Datos , Femenino , Arteria Gastroepiploica/diagnóstico por imagen , Hemodinámica , Humanos , Periodo Intraoperatorio , Masculino , Periodo Posoperatorio , Radiografía , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA