Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30883053

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/etiología , Teorema de Bayes , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
2.
Circulation ; 140(23): 1895-1903, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31553222

RESUMEN

BACKGROUND: The Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support similar to those of metallic drug-eluting stents, followed by complete resorption in ≈3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year with BVS compared with cobalt chromium everolimus-eluting stents. Between 1 and 3 years and cumulative to 3 years, adverse event rates (particularly target vessel myocardial infarction and scaffold thrombosis) were increased after BVS. We sought to assess clinical outcomes after BVS through 5 years, including beyond the 3-year time point of complete scaffold resorption. METHODS: Clinical outcomes from ABSORB III were analyzed by randomized device (intention to treat) cumulative to 5 years and between 3 and 5 years. RESULTS: Rates of target lesion failure, target vessel myocardial infarction, and scaffold thrombosis were increased through the 5-year follow-up with BVS compared with everolimus-eluting stents. However, between 3 and 5 years, reductions in the relative hazards of the BVS compared with everolimus-eluting stents were observed, particularly for target lesion failure (hazard ratio, 0.83 [95% CI, 0.55-1.24] versus 1.35 [95% CI, 1.02-1.78]; Pint=0.052) and scaffold thrombosis (hazard ratio, 0.26 [95% CI, 0.02-2.87] versus 3.23 [95% CI, 1.25-8.30]; Pint=0.056) compared with the 0- to 3-year time period. CONCLUSIONS: In the ABSORB III trial, cumulative 5-year adverse event rates were increased after BVS compared with everolimus-eluting stents. However, the period of excess risk for BVS ended at 3 years, coincident with complete scaffold resorption. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT01751906.


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/cirugía , Implantes de Medicamentos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Aleaciones de Cromo , Ensayos Clínicos Fase III como Asunto/estadística & datos numéricos , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Estudios de Equivalencia como Asunto , Everolimus/uso terapéutico , Estudios de Seguimiento , Humanos , Estudios Multicéntricos como Asunto/estadística & datos numéricos , Infarto del Miocardio/epidemiología , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Método Simple Ciego , Andamios del Tejido , Resultado del Tratamiento
3.
N Engl J Med ; 373(20): 1905-15, 2015 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-26457558

RESUMEN

BACKGROUND: In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. METHODS: In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. RESULTS: Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). CONCLUSIONS: In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Anciano , Angina de Pecho/terapia , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis
4.
Catheter Cardiovasc Interv ; 89(2): 190-198, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26909669

RESUMEN

OBJECTIVE: To examine the influence of smoking on the antiplatelet effect of clopidogrel following percutaneous coronary intervention (PCI). BACKGROUND: Certain studies suggest smokers may have enhanced clopidogrel-induced platelet inhibition compared to non-smokers after PCI. Whether this is affected by clopidogrel dose is unknown. METHODS: In this study, we conducted an analysis of 5,429 patients in the Gauging Responsiveness With A VerifyNow P2Y12 Assay: Impact on Thrombosis and Safety (GRAVITAS) trial. Platelet reactivity was assessed 12-24 hr after PCI (baseline). Patients with high on-treatment platelet reactivity (OTR) (P2Y12 reaction units [PRU] ≥ 230) were randomized to clopidogrel 75 mg or 150 mg daily. Reactivity was subsequently assessed at 30-days, and 6-months. Patients were stratified by smoking status. RESULTS: Smoking was independently associated with lower PRU (P = 0.001), and smokers were less likely to have high OTR (odds ratio 0.80, 95% confidence interval 0.68-0.94; P = 0.006) at baseline. Among patients assigned to clopidogrel 75 mg, smokers had lower PRU and were less likely to still have high OTR at 30-days (P < 0.001) and 6-months (P < 0.001). However, in patients assigned clopidogrel 150 mg, PRU and high OTR did not differ by smoking status at any time. Tests demonstrated an interaction between smoking and dose at 30 days (P = 0.007), and a trend at 6-months (P = 0.098). CONCLUSIONS: Smokers treated with clopidogrel exhibit reduced platelet reactivity and are less likely to have persistent high OTR than non-smokers. This difference is mitigated by clopidogrel 150 mg, indicating non-smokers may require double-dose therapy to achieve a similar antiplatelet effect after PCI. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Plaquetas/efectos de los fármacos , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea , Activación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Fumar/efectos adversos , Ticlopidina/análogos & derivados , Anciano , Plaquetas/metabolismo , Distribución de Chi-Cuadrado , Clopidogrel , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Relación Dosis-Respuesta a Droga , Stents Liberadores de Fármacos , Femenino , Humanos , Modelos Lineales , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/efectos adversos , Pruebas de Función Plaquetaria , Estudios Prospectivos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Receptores Purinérgicos P2Y12/efectos de los fármacos , Receptores Purinérgicos P2Y12/metabolismo , Factores de Riesgo , Fumar/sangre , Ticlopidina/administración & dosificación , Ticlopidina/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 87(4): 703-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26481591

RESUMEN

BACKGROUND: Long-term clinical outcomes after exposure to non-ionic iso-osmolar contrast medium (IOCM) or ionic low-osmolar CM (LOCM) in patients with chronic kidney disease (CKD) undergoing coronary angiography are unclear. METHODS: The ICON trial was a prospective, double-blinded, multicentre study that randomly assigned 146 patients with CKD undergoing coronary angiography with or without percutaneous coronary intervention to the non-ionic IOCM Iodixanol or the ionic LOCM Ioxaglate. We report the 1-year clinical outcomes. RESULTS: After randomization, baseline and procedural characteristics were well-matched between the two groups. At 1 year, three deaths (4.1%) occurred in the ioxaglate and nine deaths in the iodixanol group (13.6%, P = 0.07). The cardiac death rate at 1 year was 2.7% in the ioxaglate group and 9.1% in the iodixanol group (P = 0.07). There were no significant differences in the rates of myocardial infarction (1.4% vs. 1.5%; P = 1.00) and repeated revascularization (6.8% vs. 9.1%; P = 0.75). CONCLUSIONS: The use of ionic LOCM ioxaglate was associated with a numerically lower mortality at 1 year as compared to iodixanol in patients who underwent cardiac catheterization. Future studies evaluating long-term safety following exposure to different types of CM are warranted.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Angioplastia Coronaria con Balón/efectos adversos , Medios de Contraste/efectos adversos , Angiografía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Ácido Yoxáglico/efectos adversos , Fallo Renal Crónico/complicaciones , Ácidos Triyodobenzoicos/efectos adversos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/mortalidad , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Humanos , Ácido Yoxáglico/análogos & derivados , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/mortalidad , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
N Engl J Med ; 366(18): 1686-95, 2012 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-22443479

RESUMEN

BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS: The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS: A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/clasificación , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemorragia/etiología , Heparina/efectos adversos , Heparina/uso terapéutico , Humanos , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias , Falla de Prótesis , Accidente Cerebrovascular/etiología , Tasa de Supervivencia , Resultado del Tratamiento , Ultrasonografía
7.
Catheter Cardiovasc Interv ; 85(2): 207-15, 2015 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24905795

RESUMEN

OBJECTIVES: To report 1- and 2-year clinical outcomes of patients receiving platinum chromium everolimus-eluting stents (PtCr-EES) in the prospective, single-arm PLATINUM small vessel (SV) and long lesion (LL) studies. BACKGROUND: Small vessel diameter and long lesion length are independently associated with increased risk of adverse cardiac events after drug-eluting stent implantation. METHODS: The PLATINUM SV study enrolled 94 patients with coronary artery lesions in vessels ≥2.25 mm to <2.50 mm in diameter and ≤28 mm in length. The PLATINUM LL study enrolled 102 patients with lesions >24 to ≤34 mm long in vessels ≥2.50 to ≤4.25 mm in diameter. The primary endpoint for both studies was target lesion failure (TLF) at 1 year compared to a prespecified performance goal based on outcomes with the TAXUS Express paclitaxel-eluting stent in small vessels and long lesions. RESULTS: One-year TLF rates with the PtCr-EES were significantly (P < 0.001) lower than the predetermined performance goals: 2.4% versus 21.1% in the SV cohort and 3.2% versus 19.4% in the LL cohort. Cumulative rates of TLF to 2 years were 4.7% in the SV cohort and 8.8% in the LL cohort. No myocardial infarction or ARC definite/probable stent thromboses occurred in either cohort through 2-year follow-up. CONCLUSIONS: The clinical efficacy and safety outcomes observed in these small vessel and long lesion cohorts support the use of the PtCr-EES in the treatment of small diameter vessels and long lesions.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Sirolimus/análogos & derivados , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Europa (Continente) , Everolimus , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Nueva Zelanda , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
8.
Eur Heart J Imaging Methods Pract ; 2(1): qyae035, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39045181

RESUMEN

Aims: A comparison of diagnostic performance comparing AI-QCTISCHEMIA, coronary computed tomography angiography using fractional flow reserve (CT-FFR), and physician visual interpretation on the prediction of invasive adenosine FFR have not been evaluated. Furthermore, the coronary plaque characteristics impacting these tests have not been assessed. Methods and results: In a single centre, 43-month retrospective review of 442 patients referred for coronary computed tomography angiography and CT-FFR, 44 patients with CT-FFR had 54 vessels assessed using intracoronary adenosine FFR within 60 days. A comparison of the diagnostic performance among these three techniques for the prediction of FFR ≤ 0.80 was reported. The mean age of the study population was 65 years, 76.9% were male, and the median coronary artery calcium was 654. When analysing the per-vessel ischaemia prediction, AI-QCTISCHEMIA had greater specificity, positive predictive value (PPV), diagnostic accuracy, and area under the curve (AUC) vs. CT-FFR and physician visual interpretation CAD-RADS. The AUC for AI-QCTISCHEMIA was 0.91 vs. 0.76 for CT-FFR and 0.62 for CAD-RADS ≥ 3. Plaque characteristics that were different in false positive vs. true positive cases for AI-QCTISCHEMIA were max stenosis diameter % (54% vs. 67%, P < 0.01); for CT-FFR were maximum stenosis diameter % (40% vs. 65%, P < 0.001), total non-calcified plaque (9% vs. 13%, P < 0.01); and for physician visual interpretation CAD-RADS ≥ 3 were total non-calcified plaque (8% vs. 12%, P < 0.01), lumen volume (681 vs. 510 mm3, P = 0.02), maximum stenosis diameter % (40% vs. 62%, P < 0.001), total plaque (19% vs. 33%, P = 0.002), and total calcified plaque (11% vs. 22%, P = 0.003). Conclusion: Regarding per-vessel prediction of FFR ≤ 0.8, AI-QCTISCHEMIA revealed greater specificity, PPV, accuracy, and AUC vs. CT-FFR and physician visual interpretation CAD-RADS ≥ 3.

10.
J Interv Cardiol ; 26(2): 131-6, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23369084

RESUMEN

OBJECTIVE: To evaluate clinical and angiographic outcomes using a 1.20 mm diameter angioplasty catheter as part of a predilation strategy for coronary lesion treatment. BACKGROUND: Development of an angioplasty catheter with low crossing profile and small balloon diameter represents an opportunity to facilitate percutaneous revascularization of complex coronary disease. METHODS: Clinical and angiographic outcomes were evaluated following a predilation treatment strategy using a low profile, 1.20 mm angioplasty catheter. The primary end-point of procedural success was defined as successful device delivery, performance and lesion treatment without occurrence of perforation, flow-limiting dissection, reduction in baseline TIMI grade, or clinically significant arrhythmias, and with final achievement of TIMI 3 flow. In-hospital major adverse events were also determined. RESULTS: Among 71 patients (83 lesions), angiographic characteristics included: de novo lesion, 75.9%; saphenous vein graft 9.6%; lesion length (mean ± standard deviation), 12.27 ± 5.96 mm; reference vessel diameter, 2.61 ± 0.57 mm; lesion classification B2/C, 59.0%; baseline TIMI 0/1 flow, 4.8%. Procedural success was achieved for 98.5% (66/67) of patients. Catheter delivery to the target lesion was achieved in all patients, and the rate of device success with luminal improvement after predilation was 96.2% (75/78). No acute procedural complications were observed, and in-hospital target lesion failure occurred in 6 patients (8.5%) related to peri-procedural non-Q wave myocardial infarction. CONCLUSIONS: Coronary lesion predilation with a low profile, 1.20 mm angioplasty catheter is associated with favorable procedural safety and efficacy and may represent an effective treatment for complex coronary anatomy.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo/instrumentación , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Complicaciones Posoperatorias/epidemiología , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Cateterismo/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento
11.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
12.
Circulation ; 124(10): 1132-7, 2011 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-21875913

RESUMEN

BACKGROUND: In the Gauging Responsiveness With A VerifyNow P2Y12 Assay: Impact on Thrombosis and Safety (GRAVITAS) trial, 6 months of high-dose clopidogrel did not reduce cardiovascular events compared with standard-dose clopidogrel in patients with high on-treatment platelet reactivity (OTR) after percutaneous coronary intervention, defined as OTR ≥230 P2Y12 reaction units according to the VerifyNow P2Y12 platelet function test. The aim of this analysis was to examine the relationship between outcomes and OTR over the course of the trial. METHODS AND RESULTS: OTR was measured at 12 to 24 hours and 30±7 days after percutaneous coronary intervention. Cox proportional hazards models with OTR as a time-varying covariate were used to determine the association between OTR and the primary end point of cardiovascular death, myocardial infarction, and stent thrombosis. Of the 2800 enrolled patients, 2796 (99.98%) had evaluable platelet function data. OTR <208 P2Y12 reaction units was significantly associated with a lower risk of the primary end point at 60 days (hazard ratio, 0.18; 95% confidence interval, 0.04 to 0.79; P=0.02) and at 6 months (hazard ratio, 0.43; 95% confidence interval, 0.23 to 0.82; P=0.01). After adjustment for other significant predictors of outcome, OTR <208 P2Y12 reaction units remained independently associated with the primary end point at 60 days (hazard ratio, 0.23; 95% confidence interval, 0.05 to 0.98; P=0.047) and tended to be associated at 6 months (adjusted hazard ratio, 0.54; 95% confidence interval, 0.28 to 1.04; P=0.065). CONCLUSIONS: In the GRAVITAS trial, achievement of on-clopidogrel reactivity <208 P2Y12 reaction units at 12 to 24 hours after percutaneous coronary intervention or during follow-up was associated with a lower risk for cardiovascular events. The efficacy of an individualized strategy to target a level of OTR below this threshold merits investigation. Clinical Trial Registration- http://www.clinicaltrials.gov. Unique identifier: NCT00645918.


Asunto(s)
Plaquetas/efectos de los fármacos , Stents Liberadores de Fármacos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticlopidina/análogos & derivados , Síndrome Coronario Agudo/tratamiento farmacológico , Anciano , Clopidogrel , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Pruebas de Función Plaquetaria , Trombosis/tratamiento farmacológico , Ticlopidina/uso terapéutico , Resultado del Tratamiento
13.
Am Heart J ; 163(3): 438-45, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22424015

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the 5-year clinical safety and efficacy outcomes of patients treated for in-stent restenosis of bare-metal stents (BMSs). BACKGROUND: The SISR trial is a prospective, randomized trial that compared the safety and efficacy of sirolimus-eluting stent (SES) vs vascular brachytherapy (VBT) for the treatment of BMS in-stent restenosis. METHODS: A total of 384 patients with BMS in-stent restenosis were randomized to treatment with SES (n = 259) or VBT (n = 125) and were followed for 5 years. RESULTS: At 5 years, the rates of target lesion revascularization (TLR) had narrowed and were nonsignificant between the SES and VBT groups, with TLR rates of 24.7% and 31.2% (95% CI -16.3% to 2.8%, P = .179) respectively. Target vessel failure was 33.6% vs 36.8% (95% CI -13.5% to 6.7% P = .568) for SES compared with VBT. The rate of major adverse cardiac event at 5 years was 34.0% vs 36.8% (95% CI -13.1% to7.1%, P = .648) for the SES compared with VBT. There were no differences between SES and VBT in terms of survival free from TLR (72.9% vs 66.4%, log-rank P = .08) or from target vessel failure (64.4% vs 61.3%, log-rank P = .349). There were no significant differences in the rates of definite/probable stent thrombosis (5.9% vs 2.5%, 95% CI -7.9% to 1.3%, P = .182) between the 2 groups. CONCLUSIONS: At a 5-year follow-up, no differences in safety or efficacy outcomes were observed for treatment of BMS restenosis with SES vs VBT. There were no significant differences in survival free from TLR, target vessel revascularization, or major adverse cardiac events between the 2 groups at 5 years. Sirolimus-eluting stent is a viable treatment option compared with VBT for BMS restenosis.


Asunto(s)
Braquiterapia/métodos , Reestenosis Coronaria/terapia , Vasos Coronarios/efectos de la radiación , Stents Liberadores de Fármacos , Sirolimus/farmacología , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
14.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35241222

RESUMEN

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Teorema de Bayes , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 77(4): 510-4, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21351225

RESUMEN

OBJECTIVE: An unmet need is represented in angioplasty catheters that permit the predilation stage of treating complex coronary anatomy oftentimes not amenable to conventional device therapies. BACKGROUND: Lesion preparation with balloon angioplasty prior to stent placement remains the most common method of percutaneous coronary revascularization. METHODS: Clinical and angiographic outcomes were evaluated following a treatment strategy of coronary artery disease that included predilation with a low-profile, 1.25-mm angioplasty catheter prior to stent placement. The study primary end point of procedural success was defined as successful device delivery and lesion treatment, including the absence of clinically significant perforation, arrhythmia, flow-limiting dissection, or reduction in baseline Thrombolysis In Myocardial Infarction (TIMI) grade with final achievement of TIMI 3 flow. RESULTS: Among 51 patients (54 lesions), predilation using a 1.25 mm angioplasty catheter was associated with procedural and device-related success rates of 100%. In-hospital target lesion failure occurred in one patient (2.0%) related to postprocedural myocardial infarction. Patient and angiographic characteristics included diabetes, 43.1%; lesion length ≥ 20 mm, 20.4%; bifurcation lesion, 31.5%; lesion classification B2/C, 74.1%; and baseline TIMI 0/1 flow, 13.0%. No subsequent in-hospital adverse events occurred. CONCLUSIONS: Percutaneous coronary revascularization involving a predilation strategy with a low profile, 1.25-mm angioplasty catheter is associated with favorable procedural safety and efficacy and may represent an effective initial treatment for complex coronary anatomy.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres , Estenosis Coronaria/terapia , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Circulación Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Stents , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
16.
JAMA ; 305(11): 1097-105, 2011 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-21406646

RESUMEN

CONTEXT: High platelet reactivity while receiving clopidogrel has been linked to cardiovascular events after percutaneous coronary intervention (PCI), but a treatment strategy for this issue is not well defined. OBJECTIVE: To evaluate the effect of high-dose compared with standard-dose clopidogrel in patients with high on-treatment platelet reactivity after PCI. DESIGN, SETTING, AND PATIENTS: Randomized, double-blind, active-control trial (Gauging Responsiveness with A VerifyNow assay-Impact on Thrombosis And Safety [GRAVITAS]) of 2214 patients with high on-treatment reactivity 12 to 24 hours after PCI with drug-eluting stents at 83 centers in North America between July 2008 and April 2010. INTERVENTIONS: High-dose clopidogrel (600-mg initial dose, 150 mg daily thereafter) or standard-dose clopidogrel (no additional loading dose, 75 mg daily) for 6 months. MAIN OUTCOME MEASURES: The primary end point was the 6-month incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. The key safety end point was severe or moderate bleeding according to the Global Utilization of Streptokinase and t-PA for Occluded Coronary Arteries (GUSTO) definition. A key pharmacodynamic end point was the rate of persistently high on-treatment reactivity at 30 days. RESULTS: At 6 months, the primary end point had occurred in 25 of 1109 patients (2.3%) receiving high-dose clopidogrel compared with 25 of 1105 patients (2.3%) receiving standard-dose clopidogrel (hazard ratio [HR], 1.01; 95% confidence interval [CI], 0.58-1.76; P = .97). Severe or moderate bleeding was not increased with the high-dose regimen (15 [1.4%] vs 25 [2.3%], HR, 0.59; 95% CI, 0.31-1.11; P = .10). Compared with standard-dose clopidogrel, high-dose clopidogrel provided a 22% (95% CI, 18%-26%) absolute reduction in the rate of high on-treatment reactivity at 30 days (62%; 95% CI, 59%-65% vs 40%; 95% CI, 37%-43%; P < .001). CONCLUSIONS: Among patients with high on-treatment reactivity after PCI with drug-eluting stents, the use of high-dose clopidogrel compared with standard-dose clopidogrel did not reduce the incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00645918.


Asunto(s)
Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Activación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Pruebas de Función Plaquetaria , Ticlopidina/análogos & derivados , Anciano , Enfermedades Cardiovasculares/mortalidad , Clopidogrel , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/prevención & control , Agregación Plaquetaria/efectos de los fármacos , Estudios Prospectivos , Riesgo , Trombosis/prevención & control , Ticlopidina/administración & dosificación
17.
Catheter Cardiovasc Interv ; 75(3): 309-14, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-19924774

RESUMEN

OBJECTIVES: To compare the very long-term clinical outcomes of bifurcation lesions using the crush and the simultaneous kissing stent (SKS) techniques. BACKGROUND: A variety of two-stent techniques have been used to treat coronary artery bifurcation lesions in the drug-eluting stent era, but the long-term clinical outcome of these approaches is not known. METHODS: A total of 74 consecutive patients underwent bifurcation stenting using either the crush or SKS techniques. Mean patient age was 66.91 + or - 11.3 years; 26% were diabetic, and the left anterior descending/diagonal bifurcation was the most frequently treated lesion (68%). RESULTS: In-hospital outcomes were not significantly different between groups. Over a median follow-up of 3.3 years, 1 patient in the SKS group and 3 patients in the crush group died (P = ns). Probable stent thrombosis leading to death according to the Academic Research Consortium definition occurred in 1 patient in the crush group. Mortality in the remaining 3 patients was noncardiac. Target lesion revascularization (TLR) occurred in 14 patients (40%) in the SKS group and 5 patients (12.8%) in the crush group (P = 0.015). Survival free from major adverse cardiac events (MACE) was significantly less in the SKS group and predominantly driven by TLR (60 vs. 88%, P = 0.001). CONCLUSIONS: In conclusion, over a median of 3.3 years of follow-up, TLR and MACE are significantly lower in bifurcation lesions treated with the crush technique when compared with the SKS technique. Definite or probable stent thrombosis is rare with either technique.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Implantación de Prótesis , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 75(7): 1076-83, 2010 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20146209

RESUMEN

Contrast-induced nephropathy (CIN) after coronary angiography or intervention is associated with substantial morbidity. The data supporting various prophylactic measures and adjunctive therapies to prevent this complication are conflicting. However, contrast volume is clearly related to CIN after percutaneous coronary intervention (PCI), and the risk of CIN has been shown to be directly related to contrast dose. Therefore, minimizing contrast exposure is a primary method to reduce the risk of CIN, especially in at-risk patients. We report a novel technique designed to deliver ultra-low (<15 cm(3)) volume contrast to patients with chronic kidney disease undergoing coronary angiography and PCI.


Asunto(s)
Angioplastia Coronaria con Balón , Cineangiografía , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedades Renales/complicaciones , Radiografía Intervencional , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Biomarcadores/sangre , Enfermedad Crónica , Medios de Contraste/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Enfermedades Renales/fisiopatología , Masculino , Persona de Mediana Edad , Stents , Resultado del Tratamiento , Ultrasonografía Intervencional
19.
Catheter Cardiovasc Interv ; 75(5): 708-12, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-20049957

RESUMEN

OBJECTIVES: To evaluate the outcome of patients with coronary perforations who were treated with the dual catheter approach. BACKGROUND: Coronary artery perforation is a grave complication of percutaneous coronary intervention (PCI) with high mortality and morbidity. Treating a coronary artery perforation with two catheters through dual access enables a rapid delivery of covered stent or coils to the vessel, without losing control of the perforation site. METHODS: We retrospectively reviewed all patients who had a severe coronary perforation during a PCI in our center, and compared outcomes of patients treated with the dual versus the traditional single guiding catheter approach. RESULTS: Between April 2004 and October 2008, 13,466 PCI's were performed in Columbia University - New York Presbyterian Medical Center. There were 33 documented cases of coronary perforations during that period of time (0.245%), among these, 26 were angiographically severe (Ellis type 2 or 3 perforations). Eleven patients were treated acutely with a dual catheter technique whereas the other fifteen patients were treated using a single guiding catheter. In the dual catheter group one patient expired after emergent CABG (9.1%), and four patients underwent emergent paricardiocentesis (36.4%). In patients treated with single catheter, there were three deaths (20%), two surgical explorations (13.3%), eight emergent pericardiocenthesis (53.3%), and one event of severe anoxic brain damage (6.7%). CONCLUSION: The dual catheter technique is a relatively safe and reproducible approach to treat a PCI induced severe coronary artery perforation, and may improve outcome compared to historical series.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Oclusión con Balón/métodos , Cateterismo Cardíaco/métodos , Vasos Coronarios/lesiones , Enfermedad Iatrogénica , Heridas Penetrantes/terapia , Centros Médicos Académicos , Anciano , Oclusión con Balón/efectos adversos , Oclusión con Balón/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Angiografía Coronaria , Femenino , Humanos , Masculino , Ciudad de Nueva York , Estudios Retrospectivos , Rotura , Índice de Severidad de la Enfermedad , Stents , Resultado del Tratamiento , Heridas Penetrantes/diagnóstico por imagen , Heridas Penetrantes/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA