RESUMEN
In addition to specific dosimetric properties of protons, their higher biological effectiveness makes them superior to X-rays and gamma radiation, in radiation therapy. In recent years, enrichment of tumours with metallic nanoparticles as radiosensitizer agents has generated high interest, with several studies attempting to confirm the efficacy of nanoparticles in proton therapy. In the present study Geant4 Monte Carlo (MC) code was used to quantify the increased nanoscopic dose deposition of 50 nm metallic nanoparticles including gold, bismuth, iridium, and gadolinium in water upon exposure to 5, 25, and 50 MeV protons. Dose enhancement factors, radial dose distributions in nano-scale, as well as secondary electron and photon energy spectra were calculated for the studied nanoparticles and proton beams. The obtained results demonstrated that in the presence of metallic nanoparticles an increase in proton energy leads to a decrease in secondary electron and photon production yield. Additionally, an increase in the radial dose enhancement factor from 1.4 to 16 was calculated for the studied nanoparticles when the proton energy was increased from 5 to 50 MeV. It is concluded that the dosimetric advantages of proton beams could be improved significantly in the presence of metallic nanoparticles.
RESUMEN
Introduction: CTPA stands for computed tomography pulmonary angiography. CTPA is an X-ray imaging that combines X-rays and computer technology to create detailed images of the pulmonary arteries and veins in the lungs. This test diagnoses and monitors conditions like pulmonary embolism, arterial blockages, and hypertension. Coronavirus (COVID-19) has threatened world health over the last three years. The number of (CT) scans increased and played a vital role in diagnosing COVID-19 patients, including life-threatening pulmonary embolism (PE). This study aimed to assess the radiation dose resulted from CTPA for COVID-19 patients. Methods: Data were collected retrospectively from CTPA examinations on a single scanner in 84 symptomatic patients. The data collected included the dose length product (DLP), volumetric computed tomography dose index (CTDIvol), and size-specific dose estimate (SSDE). The organ dose and effective dose were estimated using VirtualDose software. Results: The study population included 84 patients, 52% male and 48% female, with an average age of 62. The average DLP, CTDIvol, and SSDE were 404.2 mGy cm, 13.5 mGy, and 11.6 mGy\, respectively. The mean effective doses (mSv) for males and females were 3.01 and 3.29, respectively. The maximum to minimum organ doses (mGy) between patients was 0.8 for the male bladder and 7.33 for the female lung. Conclusions: The increase in CT scans during the COVID-19 pandemic required close dose monitoring and optimization. The protocol used during CTPA should guarantee a minimum radiation dose with maximum patient benefits.
RESUMEN
Hallux valgus is one of the most common and painful deformities, occurring due to adductor/abductor imbalance of the big toe. Many structural foot disorders have been suggested as the cause of hallux valgus deformity. In this study, we aimed to show the relationship between hallux valgus and pes planus in adult males. A total of 213 patients were included in this study between May 2013 and May 2014. 54 patients with hallux valgus angle (HVA) >20° and intermetatarsal angle (IMA) >9° were evaluated in the case group and 159 patients randomly selected from those admitted for a recent foot ankle trauma with the HVA <15° and IMA <9° were the control group. All patients' HVA, IMA, and talonavicular coverage angle on anteroposterior (AP) foot radiographs and talar-first metatarsal angle (Meary's angle), calcaneal pitch angle, and lateral talocalcaneal angle on lateral foot radiographs were measured. There was no significant difference in talonavicular and Meary's angles between the groups. Calcaneal pitch angle was significantly lower in the case group, whereas talonavicular angle was higher in the control group. Calcaneal pitch angle and lateral talocalcaneal angle showed significant negative correlation with HVA and IMA. There are few reports in the literature about the relationship between pes planus and hallux valgus. Our results strongly showed a high correlation between pes planus and hallux valgus. Further larger patient cohort studies are needed to support our results.
Asunto(s)
Pie Plano/complicaciones , Hallux Valgus/complicaciones , Adulto , Calcáneo , Estudios de Casos y Controles , Pie Plano/diagnóstico por imagen , Pie Plano/patología , Hallux Valgus/diagnóstico por imagen , Hallux Valgus/patología , Humanos , Masculino , Radiografía , Rango del Movimiento Articular , Factores de Riesgo , Soporte de Peso , Adulto JovenRESUMEN
OBJECTIVE: The effects of quercetin and selenium on oxidative stress in endometrial adenocarcinoma cells are unclear. In this study, the effects of quercetin and selenium on oxidative stress caused by both hydrogen peroxide and UV radiation in endometrial adenocarcinoma cells were examined. METHODS: The viability of endometrial adenocarcinoma cells cultured in vitro and treated with different concentrations of quercetin and sodium selenite was measured using the MTT assay. Malondialdehyde (MDA) levels were investigated, and expression levels of BAD and p53 genes were analysed using realtime quantitative polymerase chain reaction. Acridine orange/ethidium bromide staining technique was applied to detect apoptosis. Mass attenuation coefficient of each quercetin and sodium selenite combinations was evaluated using Monte Carlo simulation. RESULTS: The combination of quercetin and sodium selenite enhanced cell viability, and reduced MDA levels. The expression levels of BAD and p53 genes decreased by combined treatment with quercetin and selenium while showing synergistic effects in terms of gene expression. Fluorescent microscopic examination showed a decrease in apoptotic cells in endometrial adenocarcinoma cells treated with the combination of quercetin and selenium. CONCLUSIONS: For the first time, selenium and quercetin have synergistic cytoprotective and radioprotective effects on oxidative stress caused by hydrogen peroxide in endometrial adenocarcinoma cells for the first time (Tab. 1, Fig. 7, Ref. 39).
Asunto(s)
Adenocarcinoma , Neoplasias Endometriales , Estrés Oxidativo , Quercetina , Selenio , Adenocarcinoma/patología , Apoptosis , Neoplasias Endometriales/patología , Femenino , Humanos , Peróxido de Hidrógeno , Malondialdehído , Estrés Oxidativo/efectos de los fármacos , Quercetina/farmacología , Selenio/farmacologíaRESUMEN
Radiotherapy is one of the commonly used treatments for cancer. A compensator is a device used in intensity modulated radiotherapy (IMRT) treatments to compensate for the irregularities of the body. One can provide a more uniform distribution of dose for the treatment of tumors using compensators in IMRT to obtain a better therapeutic outcome. A variety of compensators are used in IMRT. One high Z (cerrobend), two medium Z (brass and steel) and one low Z (lucite) compensators are selected for the present study. The mass attenuation coefficients have been computed in an energy range of 15 keV to 15 MeV using XCOM program and the Monte Carlo N-particle-5 (MCNP5) code. The percentage deviation between the values indicates that the mass attenuation coefficients obtained using both the methods are in good agreement. These values are further used to calculate the linear attenuation coefficients, mass energy absorption coefficients, effective atomic numbers, electron densities, equivalent atomic numbers and energy absorption and exposure buildup factors. All these parameters have been calculated in the energy range of 0.015-15.0 MeV. The variation of parameters has been studied with incident photon energies, chemical composition and penetration depth of the various compensators. It is observed that up to 3 MeV and 14 mean free path (mfp): compensator with lowest values of the effective atomic numbers has the highest value of the buildup factor. Cerrobend has a particularly high value of the buildup factor near 100 keV. Above 3 MeV and 14 mfp: compensator with lowest values of the effective atomic numbers has the lowest value of the buildup factor. Thus a complete reversal in trend is observed at 3 MeV and 14 mfp. All these observation have been explained due to the dominance of the different interaction processes in different energy regions.
Asunto(s)
Método de Montecarlo , Neoplasias/radioterapia , Radiometría , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Simulación por Computador , HumanosRESUMEN
This study investigates the photon interaction mechanism of various small molecule radiosensitizers, including Hydrogen Peroxide, Nimorazole, 5-Fluorouracil, NVX-108, and others, using the MCNP 6.3 Monte Carlo simulation code. The simulations focused on quantifying the linear attenuation coefficients, mean free path, and accumulation factors of these radiosensitizers, as well as their interactions in a simulated spherical water phantom irradiated with a 100 keV mono-energetic X-ray source. Our findings reveal significant variations in deposited energy, collision events, and mean free path among the radiosensitizers, indicating different efficacy levels in enhancing radiation therapy. Notably, NVX-108 demonstrated the highest energy deposition, suggesting its potential as a highly effective radiosensitizer. The study also examined the individual attenuation properties of these radiosensitizers against energetic photons, with NVX-108 showing the highest attenuation coefficient and a shorter mean free path, further supporting its superior potential in effective radiosensitization. It can be concluded that NVX-108 has higher interaction tendency with the energetic photons comparing other small-molecules under investigation.
RESUMEN
INTRODUCTION: The utilization of radiation shielding material positioned between the both breasts are crucial for the reduction of glandular dose and the safeguarding of the contralateral breast during mammographic procedures. This study proposes an alternative substance for shielding the contralateral breast from radiation exposure during mammography screening. METHODS: In this study, we present an analysis of the shielding effectiveness of transparent glass that has been doped with Tantalum (V) oxide encoded as BTZT6. The evaluation of this shielding material was conducted using the MCNPX code, specifically for the ipsilateral and contralateral breasts. The design of the left and right breast phantoms involved the creation of three-layer heterogeneous breast phantoms, consisting of varying proportions of glandular tissue (25%, 50%, and 75%). The design of BTZT6 and lead-acrylic shielding screens is implemented using the MCNPX code. The comparative analysis of dose outcomes is conducted to assess the protective efficacy of BTZT6 and lead-acrylic shielding screens. RESULTS: The utilization of BTZT6 shielding material resulted in a reduction in both breast dose and skin dose exposure when compared to the lead-acrylic shield. CONCLUSION: Based on the findings acquired, the utilization of BTZT6 shielding material screens during mammography procedures involving X-rays with energy levels ranging from 26 to 30 keV is associated with a decrease in radiation dose. IMPLICATIONS FOR PRACTICE: It can be inferred that the utilization of BTZT6 demonstrates potential efficacy in mitigating excessive radiation exposure to the breasts and facilitating the quantification of glandular doses in mammography procedures.
Asunto(s)
Tantalio , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Mamografía/métodos , Mama/diagnóstico por imagenRESUMEN
This study provides a comprehensive evaluation of the occupational radiation exposure faced by healthcare professionals during Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures. Utilizing an anthropomorphic RANDO phantom equipped with Thermoluminescent Dosimeters (TLDs), we replicated ERCP scenarios to measure radiation doses received by medical staff. The study meticulously assessed radiation exposure in various corresponding body regions typically occupied by medical staff during ERCP, with a focus on eyes, thyroid, hands, and reproductive corresponding organ regions. The findings revealed significant variations in radiation doses across different body parts, highlighting areas of higher exposure and underscoring the need for improved protective measures and procedural adjustments. The effective radiation doses were calculated using standard protocols, considering the varying levels of protection offered by lead aprons and thyroid shields. The results demonstrate the substantial radiation exposure experienced by healthcare staff, particularly in regions not adequately shielded. This study emphasizes the necessity for enhanced radiation safety protocols in clinical settings, advocating for advanced protective equipment, training in radiation safety, and the exploration of alternative imaging modalities. The findings have crucial implications for both patient and staff safety, ensuring the continued efficacy and safety of ERCP and similar interventional procedures. This research contributes significantly to the field of occupational health and safety in interventional radiology, providing vital data for the development of safer medical practices.
Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Exposición Profesional , Fantasmas de Imagen , Dosis de Radiación , Exposición a la Radiación , Protección Radiológica , Dosimetría Termoluminiscente , Humanos , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Protección Radiológica/métodos , Personal de SaludRESUMEN
In this study, it was aimed to evaluate the effect of ethanol extract of Annona Muricata (AM) leaves in the prevention of brain damage caused by ionizing radiation (IR). This study was conducted in the Experimental Animal Research Unit of a university with 28 adults female Wistar Albino rats. The experimental groups were as follows: Control group (n = 8), AM group (n = 6), IR group (n = 8), AM + IR group (n = 6). In the IR group, astrocyte hypertrophy, microglial reaction and inflammatory reaction levels were significantly higher than the control and AM groups (P < 0.001). Edema was significantly higher in the IR group compared to the control group (P=0.001). The MDA of the IR group was significantly higher compared to the control group and AM group (P=0.031, P=0.006, respectively). The MDA of the AM + IR group was significantly higher than the AM group (P=0.039). Our findings show that histomorphology and oxidant damage caused by IR can be ameliorated using AM, as demonstrated by the comparison of the controls to AM + IR recipients, which showed similar histomorphology and oxidant damage levels.
RESUMEN
We report the functional assessment of tungsten (VI) oxide on gamma-ray attenuation properties of 60Sb2O3-(40-x)NaPO3-xWO3 antimony glasses. The elemental mass-fractions and glass-densities of each glass sample are specified separately for the MCNPX Monte Carlo code. In addition to fundamental gamma absorption properties, Transmission Factors throughout a broad radioisotope energy range were measured. According to findings, holmium (Ho) incorporation into the glass structure resulted in a net increase of 0.3406 g/cm3, whereas cerium (Ce) addition resulted in a net increase of 0.2047 g/cm3. The 40% WO3 reinforced S7 sample was found to have the greatest LAC value, even though seven glass samples exhibited identical behavior. The S2 sample had the lowest HVL values among the glass groups evaluated in this work, computed in the energy range of 0.015-15 MeV. The lowest EBF and EABF values were reported for 40% WO3 reinforced S7 sample with the highest LAC and density values. According to the findings of this research, WO3 will likely make a significant contribution to the gamma ray absorption properties of antimony glasses, which are employed for optical and structural modification. Therefore, it can be concluded that WO3 may be treated monotonically and can be employed successfully in circumstances where gamma-ray absorption characteristics, optical properties, and structural qualities need to be enhanced.
RESUMEN
Introduction: We report the breast and chest radiation dose assessment for mammographic examinations using a three-layer heterogeneous breast phantom through the MCNPX Monte Carlo code. Methods: A three-layer heterogeneous phantom along with compression plates and X-ray source are modeled. The validation of the simulation code is obtained using the data of AAPM TG-195 report. Deposited energy amount as a function of increasing source energy is calculated over a wide energy range. The behavioral changes in X-ray absorption as well as transmission are examined using the F6 Tally Mesh extension of MCNPX code. Moreover, deposited energy amount is calculated for modeled body phantom in the same energy range. Results and discussions: The diverse distribution of glands has a significant impact on the quantity of energy received by the various breast layers. In layers with a low glandular ratio, low-energy primary X-ray penetrability is highest. In response to an increase in energy, the absorption in layers with a low glandular ratio decreased. This results in the X-rays releasing their energy in the bottom layers. Additionally, the increase in energy increases the quantity of energy absorbed by the tissues around the breast.
Asunto(s)
Mamografía , Método de Montecarlo , Mamografía/métodos , Dosis de Radiación , RadiografíaRESUMEN
This study's primary objective is to provide the preliminary findings of novel research on the design of Indium (III) oxide-reinforced glass container that were thoroughly developed for the purpose of a nuclear material container for transportation and waste management applications. The shielding characteristics of an Indium (III) oxide-reinforced glass container with a certain elemental composition against the 60Co radioisotope was thoroughly evaluated. The energy deposition in the air surrounding the designed portable glass containers is measured using MCNPX general-purpose Monte Carlo code. Simulation studies were carried out using Lenovo-P620 workstation and the number of tracks was defined as 108 in each simulation phase. According to results, the indium oxide-doped C6 (TZI8) container exhibits superior protective properties compared to other conventional container materials such as 0.5Bitumen-0.5 Cement, Pb Glass composite, Steel-Magnetite concrete. In addition to its superiority in terms of nuclear safety, it is proposed that the source's simultaneous observation and monitoring, as well as the C6 (TZI8) glass structure's transparency, be underlined as significant advantages. High-density glasses, which may replace undesirable materials such as concrete and lead, provide several advantages in terms of production ease, non-toxic properties, and resource monitoring. In conclusion, the use of Indium (III) oxide-reinforced glass with its high transparency and outstanding protection properties may be a substantial choice in places where concrete is required to ensure the safety of nuclear materials.
RESUMEN
Introduction: A lead-acrylic protective screen is suggested to reduce radiation exposure to the unexposed breast during mammography. The presence of toxic lead in its structure may harm the tissues with which it comes in contact. This study aimed to design a CdO-rich quaternary tellurite glass screen (C40) and evaluate its efficiency compared to the Lead-Acrylic protective screen. Methods: A three-layer advanced heterogeneous breast phantom designed in MCNPX (version 2.7.0) general-purpose Monte Carlo code. Lead acrylic and C40 shielding screens were modeled in the MCNPX and installed between the right and left breast. The reliability of the absorption differences between the lead acrylic and C40 glass were assessed. Results and discussion: The results showed that C40 protective glass screen has much superior protection properties compared to the lead acrylic protective screen. The amount of total dose absorbed in the unexposed breast for C40 was found to be much less than that for lead-based acrylic. The protection provided by the C40 glass screen is 35-38% superior to that of the Lead-Acrylic screen. The C40 offer the opportunity to avoid the toxic Pb in the structure of Lead-Acrylic material and may be utilized for mammography to offer superior radioprotection to Lead-Acrylic and significantly lower the dose amount in the unexposed breast. It can be concluded that transparent glass screens may be utilized for radiation protection purposes in critical diagnostic radiology applications through mammography.
Asunto(s)
Protección Radiológica , Protección Radiológica/métodos , Dosis de Radiación , Método de Montecarlo , Benchmarking , Reproducibilidad de los Resultados , Mamografía/métodosRESUMEN
We report the critical optical properties such as Average Visible Transmittance (AVT), colour, Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of a multicomponent glass system with a nominal composition of 50TeO2-30B2O3-(20-x)Li2O-xCeO2 (x = 0,0.5,1,2,3,4,5,10,15,20 mol%). Various advanced theoretical approaches as well as calculations are utilized in terms of determining the optical properties of studied glasses. The maximum transmittance and AVT values of the glass system exceeded 80% and 79.59%, respectively. The colour coordinates are found extremely near to D65 and the achromatic point without CeO2 contribution. According to our results, the current system has a promising ability to be utilized for coloured window applications in terms of both AVT and colour with 2% CeO2 doping. Our results showed that, the CeO2 additive is able to move the glass colour straight into the red spectrum by shifting the transmittance spectrum to the long-wavelength portion of the visible spectrum. With 10% CeO2 doping, opacity in the visible area and permeability in the NIR region are obtained, and the CCT value changes from 5002 K to 2560 K. It can be concluded that a filter system with modifiable NIR or red optical characteristics may be produced through the CeO2 alterations in borotellurite glass systems.
RESUMEN
RATIONALE AND OBJECTIVES: Radiology personnel must have good knowledge, experience and adherence to radiation protection and infection control practices to ensure patient safety and prevent the further spread of the COVID-19 virus. This study analysed compliance and adherence to radiation protection and infection control during COVID-19 mobile radiography. METHODS: A cross-sectional using online survey was conducted from September to December 2021. Data on demographic characteristics, adherence to radiation protection and infection control practice were collected during mobile radiography for COVID-19 patients in the study. A random sample of the radiographers working in COVID-19 centres in the United Arab Emirates. RESULTS: Responses were received from 140 participants, with a response rate of 87.5%. Females were the predominant participants (n = 81; 58%). Participants aged ages between 18-25 years (n = 46; 33%) and 26-35 years (n = 42; 30%), (n = 57; 41%) had less than five years of experience, followed by participants who had more than 15 years (n = 38; 27%). Most participants (n = 81; 57.9%) stated that they performed approximately 1-5 suspected or confirmed COVID-19 cases daily. The participants had moderate to high adherence to radiation protection, with a mean and standard deviation of 42.3 ± 6.28. Additionally, infection control adherence was high, with 82% of the participants showing high adherence. CONCLUSION: Continuous guidance, training and follow-up are recommended to increase adherence and compliance to radiation protection and infection control compliance. Educational institutions and professional organisations must collaborate to provide structured training programmes for radiology practitioners to overcome the practice and knowledge gap.
Asunto(s)
COVID-19 , Radiología , Femenino , Humanos , Anciano , Adolescente , Adulto Joven , Adulto , COVID-19/epidemiología , COVID-19/prevención & control , Estudios Transversales , SARS-CoV-2 , Control de InfeccionesRESUMEN
Electronic image cropping and poor collimation practices are used by some radiographers during paediatric radiography. Advantages of collimation should be investigated to disseminate convenient use among radiographers and create awareness. The aim of this study was to use Monte Carlo simulation to investigate the extent of the effect of collimation on the absorbed organ dose in neonates undergoing anterior-posterior chest examination. The minimum field size recommended by the European guidelines was calculated experimentally using a neonate phantom. A PCXMC version 2.0 simulation calculated the organ and effective doses at the minimum field size and at different field sizes. Increasing the field size by 1 cm in the head-to-feet direction increases the dose to the urinary bladder and prostate, whereas increasing the field size by 1 cm on all sides increases the dose to the upper limbs, ovaries, testicles and prostate. The use of an optimal field size reduces organ doses for neonates undergoing chest X-ray. Cropping X-ray images to reduce unnecessarily large field sizes results in unnecessary patient dosages and should be avoided. The primary beam should be restricted to expose only the area of interest, and image cropping should be discouraged.
Asunto(s)
Método de Montecarlo , Niño , Simulación por Computador , Humanos , Recién Nacido , Masculino , Fantasmas de Imagen , Dosis de Radiación , RadiografíaRESUMEN
Purpose: Diagnostic Reference Level (DRL) is a practical tool for radiation dose optimization, yet it does not indicate the patient size or image quality. The Acceptable Quality Dose (AQD) introduced to address the limitations of the DRLs and it is based on image quality, radiation dose, and patient weight. The aim of this study is to establish the AQD for adult patients' undergoing Computed Tomography (CT) examinations (Head, chest, abdomen). Methods: This study is conducted in the four main hospitals at the Ministry of Health and Prevention. Patient information and exposure parameters were extracted. All the acceptable images are scored for their quality assessments. Data is classified as seven weight groups, <50, 50-59, 60-69, 70-79, 80-89, 90-99, and ≥100 kg. The mean ± SD, median, and 75th are calculated for the CTDIvol and DLP for each weight group per examination. Results: Out of 392, 358 CT examinations are scored with acceptable quality. The median CTDIvol values for the weight groups are obtained as 24.6, 25.4, 25.4, 25.0, 26.0, 27.0, and 29.0 mGy. Moreover, median DLP values are obtained as 576.7, 601.0, 616.5, 636.1, 654.0, 650.0, 780.0, and 622.5 mGy.cm, respectively, for head CT without Contrast Media (CM). Similar calculation for head CT with (CM), chest without CM, abdomen without CM, and chest and abdomen (with and without CM) CTs are presented. Conclusion: Images with bad, unacceptable and higher than necessary qualities contribute to increasing patient dose and increasing the DRLs. The AQD for the selected examinations were lower than the proposed DRLs in the United Arab Emirates. The integration of image quality and patients size in the assessment of the AQD values provide effective model to compare radiation dose indices within facility and compare with others. The obtained results may be useful in terms of improving dose and the diagnostic quality in the national and international levels.
Asunto(s)
Medios de Contraste , Tomografía Computarizada por Rayos X , Adulto , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Emiratos Árabes UnidosRESUMEN
Purpose: This study aimed to evaluate Artificial Neural Network (ANN) modeling to estimate the significant dose length product (DLP) value during the abdominal CT examinations for quality assurance in a retrospective, cross-sectional study. Methods: The structure of the ANN model was designed considering various input parameters, namely patient weight, patient size, body mass index, mean CTDI volume, scanning length, kVp, mAs, exposure time per rotation, and pitch factor. The aforementioned examination details of 551 abdominal CT scans were used as retrospective data. Different types of learning algorithms such as Levenberg-Marquardt, Bayesian and Scaled-Conjugate Gradient were checked in terms of the accuracy of the training data. Results: The R-value representing the correlation coefficient for the real system and system output is given as 0.925, 0.785, and 0.854 for the Levenberg-Marquardt, Bayesian, and Scaled-Conjugate Gradient algorithms, respectively. The findings showed that the Levenberg-Marquardt algorithm comprehensively detects DLP values for abdominal CT examinations. It can be a helpful approach to simplify CT quality assurance. Conclusion: It can be concluded that outcomes of this novel artificial intelligence method can be used for high accuracy DLP estimations before the abdominal CT examinations, where the radiation-related risk factors are high or risk evaluation of multiple CT scans is needed for patients in terms of ALARA. Likewise, it can be concluded that artificial learning methods are powerful tools and can be used for different types of radiation-related risk assessments for quality assurance in diagnostic radiology.
Asunto(s)
Inteligencia Artificial , Tomografía Computarizada por Rayos X , Teorema de Bayes , Estudios Transversales , Humanos , Dosis de Radiación , Estudios Retrospectivos , Medición de Riesgo , Tomografía Computarizada por Rayos X/métodosRESUMEN
The nuclear spectroscopy method has long been used for advanced studies on nuclear physics. In order to decrease costs and increase the efficiency of nuclear radiation investigations, quick and efficient solutions are required. The purpose of this research was to calculate the whole energy peak efficiency values for a range of gamma-ray energies, from 30.973 keV to 1408 keV, at various source-detector distances using the MCNPX Monte Carlo code, which is extensively used in nuclear medicine, industry, and scientific research. As a result, the modeled detectors' full-energy peak efficiencies were calculated and compared to both experimental data and Monte Carlo simulations. Experiment results and prior studies using Monte Carlo simulations were found to be very consistent with these results. The counting efficiency against source-detector distance is then calculated using the modeled detectors. The data we have show that LaBr3(Ce) has outstanding detection properties. This study's findings might be used to improve the design of detectors for use in wide range of high-tech gamma spectroscopy and nuclear research applications.
RESUMEN
Assessing the current Artificial intelligence (AI) situation is a crucial step towards its implementation into radiology practice. The study aimed to assess radiographer willingness to accept AI in radiology work practice and the impact of AI in work performance. An exploratory cross-sectional online survey conducted for radiographers working within the Middle East and India was conducted from May-August 2020. A previously validated survey used to obtain radiographer's demographics, knowledge, perceptions, organization readiness, and challenges of integrating AI into radiology. The survey was accessible for radiographers and distributed through the societies page. The survey was completed by 549 radiographers distributed as (77.6%, n = 426) from the Middle East while (22.4%, n = 123) from India. A majority (86%, n = 773) agreed that AI currently plays an important role in radiology and (88.0%, n = 483) expected that AI would play a role in radiology practice and image production. The challenges for AI implementation in practice were developing AI skills (42.8%, n = 235) and AI knowledge development (37.0%, n = 203). Participants showed high interest to integrate AI in under and postgraduate curriculum. There is excitement about what AI could offer, but education input is a requirement. Fears are expressed about job security and how radiology may work across all ages and educational backgrounds. Radiographers become aware of AI role and challenges, which can be improved by education and training.