Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
CA Cancer J Clin ; 69(2): 127-157, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30720861

RESUMEN

Judgement, as one of the core tenets of medicine, relies upon the integration of multilayered data with nuanced decision making. Cancer offers a unique context for medical decisions given not only its variegated forms with evolution of disease but also the need to take into account the individual condition of patients, their ability to receive treatment, and their responses to treatment. Challenges remain in the accurate detection, characterization, and monitoring of cancers despite improved technologies. Radiographic assessment of disease most commonly relies upon visual evaluations, the interpretations of which may be augmented by advanced computational analyses. In particular, artificial intelligence (AI) promises to make great strides in the qualitative interpretation of cancer imaging by expert clinicians, including volumetric delineation of tumors over time, extrapolation of the tumor genotype and biological course from its radiographic phenotype, prediction of clinical outcome, and assessment of the impact of disease and treatment on adjacent organs. AI may automate processes in the initial interpretation of images and shift the clinical workflow of radiographic detection, management decisions on whether or not to administer an intervention, and subsequent observation to a yet to be envisioned paradigm. Here, the authors review the current state of AI as applied to medical imaging of cancer and describe advances in 4 tumor types (lung, brain, breast, and prostate) to illustrate how common clinical problems are being addressed. Although most studies evaluating AI applications in oncology to date have not been vigorously validated for reproducibility and generalizability, the results do highlight increasingly concerted efforts in pushing AI technology to clinical use and to impact future directions in cancer care.


Asunto(s)
Inteligencia Artificial , Diagnóstico por Imagen/métodos , Neoplasias/diagnóstico por imagen , Humanos
2.
World J Urol ; 41(5): 1309-1315, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36930254

RESUMEN

PURPOSE: To describe the national-level patterns of care for local ablative therapy among men with PCa and identify patient- and hospital-level factors associated with the receipt of these techniques. METHODS: We retrospectively interrogated the National Cancer Database (NCDB) for men with clinically localized PCa between 2010 and 2017. The main outcome was receipt of local tumor ablation with either cryo- or laser-ablation, and "other method of local tumor destruction including high-intensity focused ultrasound (HIFU)". Patient level, hospital level, and demographic variables were collected. Mixed effect logistic regression models were fitted to identify separately patient- and hospital-level predictors of receipt of local ablative therapy. RESULTS: Overall, 11,278 patients received ablative therapy, of whom 78.8% had cryotherapy, 15.6% had laser, and 5.7% had another method including HIFU. At the patient level, men with intermediate-risk PCa were more likely to be treated with local ablative therapy (OR 1.05; 95% CI 1.00-1.11; p = 0.05), as were men with Charlson Comorbidity Index > 1 (OR 1.36; 95% CI 1.29-1.43; p < 0.01), men between 71 and 80 years (OR 3.70; 95% CI 3.43-3.99; p < 0.01), men with Medicare insurance (OR 1.38; 95% 1.31-1.46; p < 0.01), and an income < $47,999 (OR 1.16; 95% CI 1.06-1.21; p < 0.01). At the hospital-level, local ablative therapy was less likely to be performed in academic/research facilities (OR 0.45; 95% CI 0.32-0.64; p < 0.01). CONCLUSIONS: Local ablative therapy for PCa treatment is more commonly offered among older and comorbid patients. Future studies should investigate the uptake of these technologies in non-hospital-based settings and in light of recent changes in insurance coverage.


Asunto(s)
Terapia por Láser , Neoplasias de la Próstata , Masculino , Humanos , Anciano , Estados Unidos , Estudios Retrospectivos , Medicare , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Sistema de Registros
3.
Eur Radiol ; 33(1): 461-471, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35771247

RESUMEN

OBJECTIVES: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant's ability to apply PI-QUAL. METHODS: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. RESULTS: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50-0.66]) to post-teaching (0.96 [0.92-0.98]), an improvement of 0.37 [0.21-0.41] (p < 0.001). CONCLUSIONS: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. KEY POINTS: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/patología , Becas , Neoplasias de la Próstata/patología , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
4.
Lancet Oncol ; 23(7): 910-918, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35714666

RESUMEN

BACKGROUND: Men with grade group 2 or 3 prostate cancer are often considered ineligible for active surveillance; some patients with grade group 2 prostate cancer who are managed with active surveillance will have early disease progression requiring radical therapy. This study aimed to investigate whether MRI-guided focused ultrasound focal therapy can safely reduce treatment burden for patients with localised grade group 2 or 3 intermediate-risk prostate cancer. METHODS: In this single-arm, multicentre, phase 2b study conducted at eight health-care centres in the USA, we recruited men aged 50 years and older with unilateral, MRI-visible, primary, intermediate-risk, previously untreated prostate adenocarcinoma (prostate-specific antigen ≤20 ng/mL, grade group 2 or 3; tumour classification ≤T2) confirmed on combined biopsy (combining MRI-targeted and systematic biopsies). MRI-guided focused ultrasound energy, sequentially titrated to temperatures sufficient for tissue ablation (about 60-70°C), was delivered to the index lesion and a planned margin of 5 mm or more of normal tissue, using real-time magnetic resonance thermometry for intraoperative monitoring. Co-primary outcomes were oncological outcomes (absence of grade group 2 and higher cancer in the treated area at 6-month and 24-month combined biopsy; when 24-month biopsy data were not available and grade group 2 or higher cancer had occurred in the treated area at 6 months, the 6-month biopsy results were included in the final analysis) and safety (adverse events up to 24 months) in all patients enrolled in the study. This study is registered with ClinicalTrials.gov, NCT01657942, and is no longer recruiting. FINDINGS: Between May 4, 2017, and Dec 21, 2018, we assessed 194 patients for eligibility and treated 101 patients with MRI-guided focused ultrasound. Median age was 63 years (IQR 58-67) and median concentration of prostate-specific antigen was 5·7 ng/mL (IQR 4·2-7·5). Most cancers were grade group 2 (79 [78%] of 101). At 24 months, 78 (88% [95% CI 79-94]) of 89 men had no evidence of grade group 2 or higher prostate cancer in the treated area. No grade 4 or grade 5 treatment-related adverse events were reported, and only one grade 3 adverse event (urinary tract infection) was reported. There were no treatment-related deaths. INTERPRETATION: 24-month biopsy outcomes show that MRI-guided focused ultrasound focal therapy is safe and effectively treats grade group 2 or 3 prostate cancer. These results support focal therapy for select patients and its use in comparative trials to determine if a tissue-preserving approach is effective in delaying or eliminating the need for radical whole-gland treatment in the long term. FUNDING: Insightec and the National Cancer Institute.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata , Anciano , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia
5.
Int J Cancer ; 144(3): 422-430, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30098215

RESUMEN

Recognition of <3 metastases in <2 organs, particularly in cancers with a known predisposition to oligometastatic disease (OMD) (colorectal, prostate, renal, sarcoma and lung), offers the opportunity to focally treat the lesions identified and confers a survival advantage. The reliability with which OMD is identified depends on the sensitivity of the imaging technique used for detection and may be predicted from phenotypic and genetic factors of the primary tumour, which determine metastatic risk. Whole-body or organ-specific imaging to identify oligometastases requires optimization to achieve maximal sensitivity. Metastatic lesions at multiple locations may require a variety of imaging modalities for best visualisation because the optimal image contrast is determined by tumour biology. Newer imaging techniques used for this purpose require validation. Additionally, rationalisation of imaging strategies is needed, particularly with regard to timing of imaging and follow-up studies. This article reviews the current evidence for the use of imaging for recognising OMD and proposes a risk-based roadmap for identifying patients with true OMD, or at risk of metastatic disease likely to be OM.


Asunto(s)
Neoplasias/diagnóstico por imagen , Anciano de 80 o más Años , Diagnóstico por Imagen/métodos , Humanos , Masculino , Metástasis de la Neoplasia , Neoplasias/patología , Imagen de Cuerpo Entero/métodos
6.
Radiology ; 292(2): 464-474, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31184561

RESUMEN

High-quality evidence shows that MRI in biopsy-naive men can reduce the number of men who need prostate biopsy and can reduce the number of diagnoses of clinically insignificant cancers that are unlikely to cause harm. In men with prior negative biopsy results who remain under persistent suspicion, MRI improves the detection and localization of life-threatening prostate cancer with greater clinical utility than the current standard of care, systematic transrectal US-guided biopsy. Systematic analyses show that MRI-directed biopsy increases the effectiveness of the prostate cancer diagnosis pathway. The incorporation of MRI-directed pathways into clinical care guidelines in prostate cancer detection has begun. The widespread adoption of the Prostate Imaging Reporting and Data System (PI-RADS) for multiparametric MRI data acquisition, interpretation, and reporting has promoted these changes in practice. The PI-RADS MRI-directed biopsy pathway enables the delivery of key diagnostic benefits to men suspected of having cancer based on clinical suspicion. Herein, the PI-RADS Steering Committee discusses how the MRI pathway should be incorporated into routine clinical practice and the challenges in delivering the positive health impacts needed by men suspected of having clinically significant prostate cancer.


Asunto(s)
Imagen por Resonancia Magnética Intervencional/métodos , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Sistemas de Información Radiológica , Humanos , Biopsia Guiada por Imagen , Masculino , Próstata/diagnóstico por imagen , Próstata/patología
7.
Cancer ; 124(17): 3528-3535, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-29975404

RESUMEN

BACKGROUND: Partial prostate treatment has emerged as a potential method for treating patients with favorable-risk prostate cancer while minimizing toxicity. The authors previously demonstrated poor rates of biochemical disease control for patients with National Comprehensive Cancer Network (NCCN) intermediate-risk disease using partial gland treatment with brachytherapy. The objective of the current study was to estimate the rates of distant metastasis and prostate cancer-specific mortality (PCSM) for this cohort. METHODS: Between 1997 and 2007, a total of 354 men with clinical T1c disease, a prostate-specific antigen (PSA) level < 15 ng/mL, and Gleason grade ≤3 + 4 prostate cancer underwent partial prostate treatment with brachytherapy to the peripheral zone under 0.5-Tesla magnetic resonance guidance. The cumulative incidences of metastasis and PCSM for the NCCN very low-risk, low-risk, and intermediate-risk groups were estimated. Fine and Gray competing risk regression was used to evaluate clinical factors associated with time to metastasis. RESULTS: A total of 22 patients developed metastases at a median of 11.0 years (interquartile range, 6.9-13.9 years). The 12-year metastasis rates for patients with very low-risk, low-risk, and intermediate-risk disease were 0.8% (95% confidence interval [95% CI], 0.1%-4.4%), 8.7% (95% CI, 3.4%-17.2%), and 15.7% (95% CI, 5.7%-30.2%), respectively, and the 12-year PCSM estimates were 1.6% (95% CI, 0.1%-7.6%), 1.4% (95% CI, 0.1%-6.8%), and 8.2% (95% CI, 1.9%-20.7%), respectively. On multivariate analysis, NCCN risk category (low risk: hazard ratio, 6.34 [95% CI, 1.18-34.06; P = .03] and intermediate risk: hazard ratio, 6.98 [95% CI, 1.23-39.73; P = .03]) was found to be significantly associated with the time to metastasis. CONCLUSIONS: Partial prostate treatment with brachytherapy may be associated with higher rates of distant metastasis and PCSM for patients with intermediate-risk disease after long-term follow-up. Treatment of less than the full gland may not be appropriate for this cohort.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Anciano , Braquiterapia/métodos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pronóstico , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Espera Vigilante
9.
Radiology ; 285(2): 343-356, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29045233

RESUMEN

Systematic transrectal ultrasonography (US)-guided biopsy is the standard approach for histopathologic diagnosis of prostate cancer. However, this technique has multiple limitations because of its inability to accurately visualize and target prostate lesions. Multiparametric magnetic resonance (MR) imaging of the prostate is more reliably able to localize significant prostate cancer. Targeted prostate biopsy by using MR imaging may thus help to reduce false-negative results and improve risk assessment. Several commercial devices are now available for targeted prostate biopsy, including in-gantry MR imaging-targeted biopsy and real-time transrectal US-MR imaging fusion biopsy systems. This article reviews the current status of MR imaging-targeted biopsy platforms, including technical considerations, as well as advantages and challenges of each technique. © RSNA, 2017.


Asunto(s)
Biopsia Guiada por Imagen , Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Humanos , Masculino , Imagen Multimodal , Próstata/diagnóstico por imagen , Próstata/patología , Ultrasonografía
10.
AJR Am J Roentgenol ; 209(3): W145-W151, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28657843

RESUMEN

OBJECTIVE: The purpose of this study is to determine the interobserver agreement of the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for diagnosing prostate cancer using in-bore MRI-guided prostate biopsy as the reference standard. MATERIALS AND METHODS: Fifty-nine patients underwent in-bore MRI-guided prostate biopsy between January 21, 2010, and August 21, 2013, and underwent diagnostic multiparametric MRI 6 months or less before biopsy. A single index lesion per patient was selected after retrospective review of MR images. Three fellowship-trained abdominal radiologists (with 1-11 years' experience) blinded to clinical information interpreted all studies according to PI-RADSv2. Interobserver agreement was assessed using Cohen kappa statistics. RESULTS: Thirty-eight lesions were in the peripheral zone and 21 were in the transition zone. Cancer was diagnosed in 26 patients (44%). Overall PI-RADS scores were higher for all biopsy-positive lesions (mean ± SD, 3.9 ± 1.1) than for biopsy-negative lesions (3.1 ± 1.0; p < 0.0001) and for clinically significant lesions (4.2 ± 1.0) than for clinically insignificant lesions (3.1 ± 1.0; p < 0.0001). Overall suspicion score interobserver agreement was moderate (κ = 0.45). There was moderate interobserver agreement among overall PI-RADS scores in the peripheral zone (κ = 0.46) and fair agreement in the transition zone (κ = 0.36). CONCLUSION: PI-RADSv2 scores were higher in the biopsy-positive group. PI-RADSv2 showed moderate interobserver agreement among abdominal radiologists with no prior experience using the scoring system.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
Cancer ; 121(6): 817-27, 2015 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-25204551

RESUMEN

The authors review methods for image-guided diagnosis and therapy that increase precision in the detection, characterization, and localization of many forms of cancer to achieve optimal target definition and complete resection or ablation. A new model of translational, clinical, image-guided therapy research is presented, and the Advanced Multimodality Image-Guided Operating (AMIGO) suite is described. AMIGO was conceived and designed to allow for the full integration of imaging in cancer diagnosis and treatment. Examples are drawn from over 500 procedures performed on brain, neck, spine, thorax (breast, lung), and pelvis (prostate and gynecologic) areas and are used to describe how they address some of the many challenges of treating brain, prostate, and lung tumors. Cancer 2015;121:817-827. © 2014 American Cancer Society.


Asunto(s)
Diagnóstico por Imagen/métodos , Imagen Multimodal/métodos , Neoplasias/diagnóstico , Diagnóstico por Imagen/instrumentación , Humanos , Imagen Multimodal/instrumentación , Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Radiografía
12.
Radiology ; 274(1): 170-80, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25222067

RESUMEN

PURPOSE: To determine the detection rate, clinical relevance, Gleason grade, and location of prostate cancer ( PCa prostate cancer ) diagnosed with and the safety of an in-bore transperineal 3-T magnetic resonance (MR) imaging-guided prostate biopsy in a clinically heterogeneous patient population. MATERIALS AND METHODS: This prospective retrospectively analyzed study was HIPAA compliant and institutional review board approved, and informed consent was obtained. Eighty-seven men (mean age, 66.2 years ± 6.9) underwent multiparametric endorectal prostate MR imaging at 3 T and transperineal MR imaging-guided biopsy. Three subgroups of patients with at least one lesion suspicious for cancer were included: men with no prior PCa prostate cancer diagnosis, men with PCa prostate cancer who were undergoing active surveillance, and men with treated PCa prostate cancer and suspected recurrence. Exclusion criteria were prior prostatectomy and/or contraindication to 3-T MR imaging. The transperineal MR imaging-guided biopsy was performed in a 70-cm wide-bore 3-T device. Overall patient biopsy outcomes, cancer detection rates, Gleason grade, and location for each subgroup were evaluated and statistically compared by using χ(2) and one-way analysis of variance followed by Tukey honestly significant difference post hoc comparisons. RESULTS: Ninety biopsy procedures were performed with no serious adverse events, with a mean of 3.7 targets sampled per gland. Cancer was detected in 51 (56.7%) men: 48.1% (25 of 52) with no prior PCa prostate cancer , 61.5% (eight of 13) under active surveillance, and 72.0% (18 of 25) in whom recurrence was suspected. Gleason pattern 4 or higher was diagnosed in 78.1% (25 of 32) in the no prior PCa prostate cancer and active surveillance groups. Gleason scores were not assigned in the suspected recurrence group. MR targets located in the anterior prostate had the highest cancer yield (40 of 64, 62.5%) compared with those for the other parts of the prostate (P < .001). CONCLUSION: In-bore 3-T transperineal MR imaging-guided biopsy, with a mean of 3.7 targets per gland, allowed detection of many clinically relevant cancers, many of which were located anteriorly.


Asunto(s)
Biopsia Guiada por Imagen , Imagen por Resonancia Magnética Intervencional/métodos , Neoplasias de la Próstata/patología , Anciano , Medios de Contraste , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Perineo , Estudios Prospectivos
13.
IEEE ASME Trans Mechatron ; 20(4): 1920-1932, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26412962

RESUMEN

This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure.

14.
Eur Urol ; 85(5): 466-482, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38519280

RESUMEN

BACKGROUND AND OBJECTIVE: Magnetic resonance imaging (MRI) can detect recurrences after focal therapy for prostate cancer but there is no robust guidance regarding its use. Our objective was to produce consensus recommendations on MRI acquisition, interpretation, and reporting after focal therapy. METHODS: A systematic review was performed in July 2022 to develop consensus statements. A two-round consensus exercise was then performed, with a consensus meeting in January 2023, during which 329 statements were scored by 23 panellists from Europe and North America spanning urology, radiology, and pathology with experience across eight focal therapy modalities. Using RAND Corporation/University of California-Los Angeles methodology, the Transatlantic Recommendations for Prostate Gland Evaluation with MRI after Focal Therapy (TARGET) were based on consensus for statements scored with agreement or disagreement. KEY FINDINGS AND LIMITATIONS: In total, 73 studies were included in the review. All 20 studies (100%) reporting suspicious imaging features cited focal contrast enhancement as suspicious for cancer recurrence. Of 31 studies reporting MRI assessment criteria, the Prostate Imaging-Reporting and Data System (PI-RADS) score was the scheme used most often (20 studies; 65%), followed by a 5-point Likert score (six studies; 19%). For the consensus exercise, consensus for statements scored with agreement or disagreement increased from 227 of 295 statements (76.9%) in round one to 270 of 329 statements (82.1%) in round two. Key recommendations include performing routine MRI at 12 mo using a multiparametric protocol compliant with PI-RADS version 2.1 standards. PI-RADS category scores for assessing recurrence within the ablation zone should be avoided. An alternative 5-point scoring system is presented that includes a major dynamic contrast enhancement (DCE) sequence and joint minor diffusion-weighted imaging and T2-weighted sequences. For the DCE sequence, focal nodular strong early enhancement was the most suspicious imaging finding. A structured minimum reporting data set and minimum reporting standards for studies detailing MRI data after focal therapy are presented. CONCLUSIONS AND CLINICAL IMPLICATIONS: The TARGET consensus recommendations may improve MRI acquisition, interpretation, and reporting after focal therapy for prostate cancer and provide minimum standards for study reporting. PATIENT SUMMARY: Magnetic resonance imaging (MRI) scans can detect recurrent of prostate cancer after focal treatments, but there is a lack of guidance on MRI use for this purpose. We report new expert recommendations that may improve practice.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/patología , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Imagen de Difusión por Resonancia Magnética
15.
Eur Urol ; 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38556436

RESUMEN

BACKGROUND AND OBJECTIVE: The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) recommendations standardise the reporting of prostate magnetic resonance imaging (MRI) in patients on active surveillance (AS) for prostate cancer. An international consensus group recently updated these recommendations and identified the areas of uncertainty. METHODS: A panel of 38 experts used the formal RAND/UCLA Appropriateness Method consensus methodology. Panellists scored 193 statements using a 1-9 agreement scale, where 9 means full agreement. A summary of agreement, uncertainty, or disagreement (derived from the group median score) and consensus (determined using the Interpercentile Range Adjusted for Symmetry method) was calculated for each statement and presented for discussion before individual rescoring. KEY FINDINGS AND LIMITATIONS: Participants agreed that MRI scans must meet a minimum image quality standard (median 9) or be given a score of 'X' for insufficient quality. The current scan should be compared with both baseline and previous scans (median 9), with the PRECISE score being the maximum from any lesion (median 8). PRECISE 3 (stable MRI) was subdivided into 3-V (visible) and 3-NonV (nonvisible) disease (median 9). Prostate Imaging Reporting and Data System/Likert ≥3 lesions should be measured on T2-weighted imaging, using other sequences to aid in the identification (median 8), and whenever possible, reported pictorially (diagrams, screenshots, or contours; median 9). There was no consensus on how to measure tumour size. More research is needed to determine a significant size increase (median 9). PRECISE 5 was clarified as progression to stage ≥T3a (median 9). CONCLUSIONS AND CLINICAL IMPLICATIONS: The updated PRECISE recommendations reflect expert consensus opinion on minimal standards and reporting criteria for prostate MRI in AS. PATIENT SUMMARY: The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) recommendations are used in clinical practice and research to guide the interpretation and reporting of magnetic resonance imaging for patients on active surveillance for prostate cancer. An international panel has updated these recommendations, clarified the areas of uncertainty, and highlighted the areas for further research.

16.
J Magn Reson Imaging ; 37(5): 1035-54, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23606141

RESUMEN

Magnetic resonance (MR) examinations of men with prostate cancer are most commonly performed for detecting, characterizing, and staging the extent of disease to best determine diagnostic or treatment strategies, which range from biopsy guidance to active surveillance to radical prostatectomy. Given both the exam's importance to individual treatment plans and the time constraints present for its operation at most institutions, it is essential to perform the study effectively and efficiently. This article reviews the most commonly employed modern techniques for prostate cancer MR examinations, exploring the relevant signal characteristics from the different methods discussed and relating them to intrinsic prostate tissue properties. Also, a review of recent articles using these methods to enhance clinical interpretation and assess clinical performance is provided. J. Magn. Reson. Imaging 2013;37:1035-1054. © 2013 Wiley Periodicals, Inc.


Asunto(s)
Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Próstata/patología , Neoplasias de la Próstata/patología , Predicción , Humanos , Masculino
17.
BJUI Compass ; 4(4): 473-481, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37334024

RESUMEN

Rationale and objectives: The study aims to propose an optimal workflow in patients with a PI-RADS 3 (PR-3) assessment category (AC) through determining the timing and type of pathology interrogation used for the detection of clinically significant prostate cancer (csPCa) in these men based upon a 5-year retrospective review in a large academic medical center. Materials and methods: This United States Health Insurance Probability and Accountability Act (HIPAA)-compliant, institutional review board-approved retrospective study included men without prior csPCa diagnosis who received PR-3 AC on magnetic resonance (MR) imaging (MRI). Subsequent incidence and time to csPCa diagnosis and number/type of prostate interventions was recorded. Categorical data were compared using Fisher's exact test and continuous data using ANOVA omnibus F-test. Results: Our cohort of 3238 men identified 332 who received PR-3 as their highest AC on MRI, 240 (72.3%) of whom had pathology follow-up within 5 years. csPCa was detected in 76/240 (32%) and non-csPCa in 109/240 (45%) within 9.0 ± 10.6 months. Using a non-targeted trans-rectal ultrasound biopsy as the initial approach (n = 55), another diagnostic procedure was required to diagnose csPCa in 42/55 (76.4%) of men, compared with 3/21(14.3%) men with an initial MR targeted-biopsy approach (n = 21); (p < 0.0001). Those with csPCa had higher median serum prostate-specific antigen (PSA) and PSA density, and lower median prostate volume (p < 0.003) compared with non-csPCa/no PCa. Conclusion: Most patients with PR-3 AC underwent prostate pathology exams within 5 years, 32% of whom were found to have csPCa within 1 year of MRI, most often with a higher PSA density and a prior non-csPCa diagnosis. Addition of a targeted biopsy approach initially reduced the need for a second biopsy to reach a for csPCa diagnosis. Thus, a combination of systematic and targeted biopsy is advised in men with PR-3 and a co-existing abnormal PSA and PSA density.

18.
Eur Urol Oncol ; 6(2): 160-182, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36710133

RESUMEN

BACKGROUND: Active surveillance (AS) is recommended for low-risk and some intermediate-risk prostate cancer. Uptake and practice of AS vary significantly across different settings, as does the experience of surveillance-from which tests are offered, and to the levels of psychological support. OBJECTIVE: To explore the current best practice and determine the most important research priorities in AS for prostate cancer. DESIGN, SETTING, AND PARTICIPANTS: A formal consensus process was followed, with an international expert panel of purposively sampled participants across a range of health care professionals and researchers, and those with lived experience of prostate cancer. Statements regarding the practice of AS and potential research priorities spanning the patient journey from surveillance to initiating treatment were developed. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Panel members scored each statement on a Likert scale. The group median score and measure of consensus were presented to participants prior to discussion and rescoring at panel meetings. Current best practice and future research priorities were identified, agreed upon, and finally ranked by panel members. RESULTS AND LIMITATIONS: There was consensus agreement that best practice includes the use of high-quality magnetic resonance imaging (MRI), which allows digital rectal examination (DRE) to be omitted, that repeat standard biopsy can be omitted when MRI and prostate-specific antigen (PSA) kinetics are stable, and that changes in PSA or DRE should prompt MRI ± biopsy rather than immediate active treatment. The highest ranked research priority was a dynamic, risk-adjusted AS approach, reducing testing for those at the least risk of progression. Improving the tests used in surveillance, ensuring equity of access and experience across different patients and settings, and improving information and communication between and within clinicians and patients were also high priorities. Limitations include the use of a limited number of panel members for practical reasons. CONCLUSIONS: The current best practice in AS includes the use of high-quality MRI to avoid DRE and as the first assessment for changes in PSA, with omission of repeat standard biopsy when PSA and MRI are stable. Development of a robust, dynamic, risk-adapted approach to surveillance is the highest research priority in AS for prostate cancer. PATIENT SUMMARY: A diverse group of experts in active surveillance, including a broad range of health care professionals and researchers and those with lived experience of prostate cancer, agreed that best practice includes the use of high-quality magnetic resonance imaging, which can allow digital rectal examination and some biopsies to be omitted. The highest research priority in active surveillance research was identified as the development of a dynamic, risk-adjusted approach.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata , Masculino , Humanos , Consenso , Espera Vigilante/métodos , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/terapia , Neoplasias de la Próstata/patología , Investigación
19.
Cancer ; 118(19): 4777-84, 2012 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22282219

RESUMEN

BACKGROUND: Treatment of high-risk localized prostate cancer remains inadequate. The authors performed a phase 2 multicenter trial of neoadjuvant docetaxel plus bevacizumab before radical prostatectomy. METHODS: Eligibility included any of the following: prostate-specific antigen (PSA) >20 ng/mL or PSA velocity >2 ng/mL/y, cT3 disease, any biopsy Gleason score 8 to 10, and Gleason score 7 with T3 disease by endorectal magnetic resonance imaging (MRI) at 1.5 T. Also, those with ≥50% biopsy cores involved and either Gleason score 7, PSA >10, or cT2 disease were eligible. Patients were treated with docetaxel 70 mg/m(2) every 3 weeks for 6 cycles and bevacizumab 15 mg/m(2) every 3 weeks for 5 cycles. The primary endpoint was partial response by endorectal MRI. RESULTS: Forty-one patients were treated. Median age was 55 years (range, 40-66 years). Baseline characteristics included: median PSA, 10.1 ng/mL; cT2, 49%, cT3, 32%; and Gleason score 8 to 10, 73%. Thirty-eight of 41 (93%) patients completed all 6 cycles. Grade ≥3 adverse events were rare, although 3 of 41 (7%) experienced febrile neutropenia. Twelve patients (29%; 95% confidence interval [CI], 16%-45%) achieved a >50% reduction in tumor volume, and 9 patients (22%; 95% CI, 11%-38%) achieved a >50% post-treatment decline in PSA. Thirty-seven of the 41 patients underwent radical prostatectomy; there were no complete pathologic responses. CONCLUSIONS: Neoadjuvant docetaxel and bevacizumab is safe, and results in reductions in both tumor volume and serum PSA, in men with high-risk localized prostate cancer. The role of neoadjuvant chemotherapy in prostate cancer, and perioperative antiangiogenic therapy in general, requires further elucidation through ongoing and planned trials.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Biomarcadores de Tumor/sangre , Terapia Neoadyuvante/métodos , Antígeno Prostático Específico/sangre , Prostatectomía , Neoplasias de la Próstata/tratamiento farmacológico , Neoplasias de la Próstata/cirugía , Adulto , Anciano , Inhibidores de la Angiogénesis/administración & dosificación , Inhibidores de la Angiogénesis/efectos adversos , Anticuerpos Monoclonales Humanizados/administración & dosificación , Anticuerpos Monoclonales Humanizados/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Bevacizumab , Docetaxel , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Neutropenia/inducido químicamente , Neoplasias de la Próstata/inmunología , Neoplasias de la Próstata/patología , Medición de Riesgo , Factores de Riesgo , Taxoides/administración & dosificación , Taxoides/efectos adversos , Resultado del Tratamiento
20.
Magn Reson Med ; 68(5): 1376-82, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22648701

RESUMEN

The purpose of this work was to evaluate a previously proposed approach that aims to improve the point spread function (PSF) of MR spectroscopic imaging (MRSI) to avoid corruption by lipid signal arising from neighboring voxels. Retrospective spatial filtering can be used to alter the PSF; however, this either reduces spatial resolution or requires extending the acquisition in k-space at the cost of increased imaging time. Alternatively, the method evaluated here, PSF-choice, can modify the PSF localization to reduce the contamination from adjacent lipids by conforming the signal response more closely to the desired MRSI voxel grid. This is done without increasing scan time or degrading SNR of important metabolites. PSF-choice achieves improvements in spatial localization through modifications to the radiofrequency excitation pulses. An implementation of this method is reported for MRSI of the prostate, where it is demonstrated that, in 13 of 16 pilot prostate MRSI scans, intravoxel spectral contamination from lipid was significantly reduced when using PSF-choice. Phantom studies were also performed that demonstrate, compared with MRSI with standard Fourier phase encoding, out-of-voxel signal contamination of spectra was significantly reduced in MRSI with PSF-choice.


Asunto(s)
Tejido Adiposo/química , Algoritmos , Artefactos , Lípidos/análisis , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Neoplasias de la Próstata/química , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA