1.
BMC Pregnancy Childbirth ; 23(1): 788, 2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-37951881

RESUMEN

BACKGROUND: Pregnancy has major effects that make hematology parameters outside of normal reference ranges. Therefore, we conducted this study to establish reference intervals for Vietnamese pregnant women. METHODS: From June 2023 to Augst 2023, blood samples from 879 eligible pregnant women were run on DxH 900 hematology analyzer and ACL TOP 550 coagulation analyzer. The tested parameters are prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB), white blood cell (WBC) and its differentials (neutrophils, lymphocytes, monocytes, eosinophils and basophils), red blood cell (RBC), hemoglobin (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), RBC distribution width (RDW), RBC distribution width standard deviation (RDW-SD), platelet count (PLT), mean platelet volume (MPV). A non-parametric method was used to establish the 2.5th and 97.5th percentile reference intervals. RESULTS: PT, APTT decrease but fibrinogen increases during pregnancy. Physiological adaptations of pregnancy result in a decrease in RBC count, but an increase in WBC count and no changes in platelet count. The reference intervals for PT (seconds), APTT (seconds), fibrinogen (mg/dL), in the first trimester were 10.30-12.88, 25.40-35.46, 280.28-559.00, in the second trimester were 9.80-11.66, 24.05-33.23, 347.75-593.35, in the third trimester were 9.60-11.40, 23.40-31.80, 330.28-628.56, respectively. The reference intervals for main hematology parameters which are WBC (× 109/L), RBC (× 1012/L), HGB (g/dL), HCT (%), PLT (× 109/L) in the first trimester were 6.33-15.24, 3.73-5.32, 10.33-13.95, 32.22-42.29, 169.66-413.88, in the second trimester were 6.99-15.55, 3.33-4.98, 9.71-13.17, 30.26-40.07, 172.34-372.19, in the third trimester were 6.22-14.14, 3.54-4.98, 9.80-13.97, 31.11-42.70, 151.30-417.14, respectively. CONCLUSIONS: Most established referenced intervals from each trimester differ from other trimesters. These trimester-specific reference ranges for Vietnamese pregnant women will aid clinicians in entepreting parameters and help other laboratories adopt these ranges after validating. TRIAL REGISTRATION: This study is registered at www. CLINICALTRIALS: gov as NCT05929326.


Asunto(s)
Mujeres Embarazadas , Pueblos del Sudeste Asiático , Femenino , Embarazo , Humanos , Recuento de Células Sanguíneas , Pruebas de Coagulación Sanguínea , Hemoglobinas/análisis , Fibrinógeno , Valores de Referencia
2.
J Diabetes Investig ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39087885

RESUMEN

AIMS/INTRODUCTION: Blood glucose meters are commonly used at the bedside, but most of the meters used in Hung Vuong Hospital (Ho Chi Minh City, Vietnam) are built for self-monitoring and might not be suitable for determining glucose levels in patients. In this study, we aimed to validate the performance of six frequently used meters in our hospital using the Clinical & Laboratory Standards Institute (CLSI) standard, and investigate the hematocrit impact on the accuracy of these meters. MATERIALS AND METHODS: A total of 135 pregnant women who underwent a 75-g oral glucose tolerance test consented to participate in the study at Hung Vuong Hospital. Whole blood glucose levels were measured in duplicate using meters, and hematocrit levels were measured using an Alinity h-series analyzer. Within 5 min, plasma glucose levels were measured twice in a row using the Cobas c502 reference analyzer. For accuracy and precision, the hematocrit effect was assed using CLSI POCT12-A3. RESULTS: Out of six evaluated meters, three meters qualified. For CLSI criterion at glucose concentration of 5.55 mmol/L, Accu-Chek Inform II, Accu-Chek Performa and OneTouch VerioVue achieved 97.31%, 98.08% and 99.62%, respectively. For CLSI criterion at 4.17 mmol/L, these three achieved 100%. Accu-Chek Inform II and Accu-Chek Performa showed an inverse correlation between glucose level and hematocrit with slopes of -0.500 (95% confidence interval -0.678 to -0.322) and -0.396 (95% confidence interval -0.569 to -0.224), whereas OneTouch VerioVue was not affected by hematocrit, with a slope of 0.207 (95% confidence interval -0.026 to 0.440). CONCLUSIONS: Blood glucose meters' measurements can be affected by hematocrit, and might provide readings not within an acceptable bias. Medical organizations need to verify or validate before using on patients.