RESUMEN
BACKGROUND: The introduction of transcatheter edge-to-edge repair for moderate-to-severe or severe mitral regurgitation (MR) utilizing the MitraClip system became reimbursed and clinically accessible in Japan in April 2018. This study presents the 2-year clinical outcomes of all consecutively treated patients who underwent MitraClip implantation in Japan and were prospectively enrolled in the Japanese Circulation Society-oriented J-MITRA registry. METHODSâANDâRESULTS: Analysis encompassed 2,739 consecutive patients enrolled in the J-MITRA registry with informed consent (mean age: 78.3±9.6 years, 1,550 males, STS risk score 11.7±8.9), comprising 1,999 cases of functional MR, 644 of degenerative MR and 96 in a mixed group (DMR and FMR). The acute procedure success rate was 88.9%. After MitraClip implantation, >80% exhibited an MR grade ≤2+ and the trend was sustained over the 2 years. Within this observation period, the mortality rate was 19.3% and the rate of heart failure readmissions was 20.6%. The primary composite endpoint, inclusive of cardiovascular death and heart failure readmission, was significantly higher in patients with functional MR than in with degenerative MR (32.0% vs. 17.5%, P<0.001). CONCLUSIONS: The 2-year clinical outcomes after MitraClip implantation were deduced from comprehensive data within an all-Japan registry.
Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Válvula Mitral/cirugía , Datos de Salud Recolectados Rutinariamente , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversosRESUMEN
The patient was diagnosed with perimembranous ventricular septal defect (VSD). She underwent VSD closure and muscle bundle resection across right ventricular outflow tract at the age of 3 months. Since then, she had suffered from severe heart failure and complete heart block. Permanent pacemaker generator was implanted in the left hypochondrium. She was depended on continuous catecholamine administration, so transferred to our hospital for further management. On arrival, her body weight was 5686 g (- 2.7 SD). She underwent Excor pediatric left ventricular assist device implantation at the age of 9 months. Because the position of the left ventricular assist device cannula interfered with the pacemaker, herein, the pacemaker pocket was newly created in the left thoracic cavity. An 1 mm in thickness of expanded polytetrafluoroethylene sheet was trimmed and sutured under the anterolateral wall of left thoracic cavity as a pacemaker pocket. Bipolar ventricular lead was sutured on left ventricular apex and basal wall to face each other, mimicking cardiac regeneration therapy. Even though she unfortunately required right diaphragmatic plication for iatrogenic phrenic nerve palsy, her respiratory function was well maintained; therefore, secondary right heart failure was not observed. Her cardiopulmonary function was quite stable until post-operative day 275 when the patient was transferred to another hospital for heart transplantation.
Asunto(s)
Bloqueo Cardíaco , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Femenino , Lactante , Bloqueo Cardíaco/terapia , Bloqueo Cardíaco/etiología , Bloqueo Cardíaco/cirugía , Defectos del Tabique Interventricular/cirugíaRESUMEN
PURPOSE: Bleeding complication is a critical risk factor for outcomes of acute heart failure patients requiring mechanical circulatory support (MCS), including percutaneous catheter-type heart pumps (Impella). The Japanese registry for Percutaneous Ventricular Assist Device (J-PVAD) is an ongoing, large-scale, real-world registry to characterize Japanese patients requiring Impella. Here we analyzed bleeding complication profiles in patients who received Impella. METHODS: All consecutive Japanese patients who received Impella from October 2017 to January 2020 were enrolled. The 30-day survival and bleeding complications were analyzed. RESULTS: A total of 1344 patients were included: 653 patients received Impella alone, 685 patients received a combination of veno-arterial extracorporeal membrane oxygenation and Impella (ECPELLA), and 6 patients had failed Impella delivery. Overall 30-day survival was 67.0%, with Impella alone at 81.9% and ECPELLA at 52.7%. Overall bleeding/hematoma adverse events with a relation or not-excluded relation to Impella was 6.92%. Among them, the rates of hematoma and bleeding from medical device access sites were 1.41% and 4.09%, respectively. There was no difference between etiologies for these events. CONCLUSION: This study represents the first 3-year survival and the safety profile focused on bleeding adverse events from the J-PVAD registry. The results show that the real-world frequency of bleeding adverse events for patients who received Impella was an expected range from previous reports, and future real-world studies should aim to expand this data set to improve outcomes and adverse events.
RESUMEN
A six-month-old boy with Down syndrome, complete atrioventricular septal defect with intact atrial septum, and moderate left-sided atrioventricular valve regurgitation underwent surgery. The presence of a common atrioventricular junction could not be diagnosed preoperatively. Postoperative left-sided atrioventricular valve regurgitation remained mild by complete cleft closure, direct closure of incised atrial septum, and patch augmentation of the underside of septum primum.
RESUMEN
A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.
Asunto(s)
Enfermedades de la Aorta , Procedimientos Endovasculares , Cuerpos Extraños , Masculino , Humanos , Persona de Mediana Edad , Hematemesis/complicaciones , Esófago/diagnóstico por imagen , Esófago/cirugía , Enfermedades de la Aorta/cirugía , Cuerpos Extraños/complicaciones , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/cirugíaRESUMEN
BACKGROUND: Fulminant myocarditis (FM) is rare but has an extremely poor prognosis. Impella, a catheter-based heart pump, is a new therapeutic strategy, but reports regarding its health economics are lacking.MethodsâandâResults: This retrospective cohort study compared Impella treatment (Group I) with existing treatments (Group E) using medical data collected from October 2017 to September 2021, with a 1-year analysis period. Cost-effectiveness indices were life-years (LY; effect index) and medical fee amount (cost index). Results were validated using probabilistic sensitivity analysis. The incremental cost-effectiveness ratio (ICER) was calculated using quality-adjusted LY (QALY) and medical costs. Each group included 7 patients, and more than half (57.1%) received combined Impella plus extracorporeal membrane oxygenation. There was no significant difference between Groups I and E in 1-year mortality rates (28.6% vs. 57.1%, respectively) or LY (mean [±SD] 163.1±128.3 vs. 107.8±127.3 days, respectively), but mortality risk was significantly lower in Group I than Group E (95% confidence interval 0.02-0.96; P<0.05). Compared with Group E, Group I had higher total costs (9,270,597±4,121,875 vs. 6,397,466±3,801,364 JPY/year; P=0.20) and higher cost-effectiveness (32,443,987±14,742,966 vs. 92,637,756±98,225,604 JPY/LY; P=0.74), which was confirmed in the sensitivity analysis. ICER probability distribution showed 23.2% and 51.5% reductions below 5 million and 10 million JPY/QALY, respectively. CONCLUSIONS: Impella treatment is more cost-effective than conventional FM treatments. Large-scale studies are needed to validate the added effects and increasing costs.
Asunto(s)
Miocarditis , Humanos , Análisis Costo-Beneficio , Japón/epidemiología , Miocarditis/terapia , Estudios RetrospectivosRESUMEN
BACKGROUND: The Impella®percutaneous left ventricular assist device has been available in Japan since 2017. This is the first large-scale registry study to analyze the efficacy and safety of Impella in Japanese patients with acute myocardial infarction with cardiogenic shock (AMICS).MethodsâandâResults: The Japanese registry for Percutaneous Ventricular Assist Device (J-PVAD) has registered all consecutive Japanese patients treated with Impella. We extracted data for 593 AMICS patients from J-PVAD and analyzed 30-day survival and safety profiles. Overall 30-day survival was 63.1%. The 30-day survival of the Impella alone and Impella plus venoarterial extracorporeal membrane oxygenation (ECPELLA) groups was 80.9% and 45.7%, respectively. The Impella alone group was older and had a lower rate of cardiac arrest, milder consciousness disturbance, less inotrope use, lower serum lactate concentrations, higher B-type natriuretic peptide concentrations, and higher left ventricular ejection fraction (LVEF) than the ECPELLA group. Cox regression analysis revealed that older age and comorbid renal disturbance were common risk factors affecting 30-day mortality in both groups. Major adverse events were hemolysis (10.8%), hemorrhage/hematoma (7.6%), peripheral ischemia (4.4%), stroke (1.3%), and thrombosis (0.7%). LVEF improved in both groups during support. CONCLUSIONS: AMICS treatment with Impella showed favorable 30-day survival and safety profiles. The survival rate of patients treated with Impella alone was particularly high. Further studies are needed to improve outcomes of patients with ECPELLA support.
Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Volumen Sistólico , Corazón Auxiliar/efectos adversos , Pueblos del Este de Asia , Estudios Retrospectivos , Función Ventricular Izquierda , Sistema de Registros , Resultado del TratamientoRESUMEN
BACKGROUND: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.MethodsâandâResults: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score. CONCLUSIONS: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Datos de Salud Recolectados Rutinariamente , Factores de Riesgo , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
Sutureless offers an alternative to standard valves in surgical aortic valve replacement (SAVR). We sought to confirm the efficacy and safety of the Perceval sutureless valve in Japanese patients. Prospective observational study of 204 patients who underwent SAVR with Perceval at 19 sites in Japan between March and December 2019. The primary outcomes were 30-day mortality and postoperative complications; the secondary outcome was all-cause mortality at 1 year. Efficacy outcomes were changed in New York Heart Association (NYHA) class, pressure gradients, effective orifice area (EOA), EOA indexed to body surface area (EOAi) and severity of aortic regurgitation. Mean age was 77.7 years, 62.7% were female. Procedural success rate was 99.0%. The median cross-clamp and cardiopulmonary bypass times were 68.0 and 108 min. Perceval size S and M were implanted in 95 (46.6%) and in 76 (37.3%) of patients, respectively. The 30-day and late mortality rate were 0.5% and 4.4%, while the new permanent pacemaker implantation rate was 4.4%. Mean pressure gradient was 13.0 mmHg at discharge, reaching 11.0 mmHg at 1 year; while the mean EOA was 1.5 cm2 at discharge remaining stable up to 1 year. No moderate or severe leakages were present at discharge or at 1 year. NYHA class improved by ≥ 1 level in 55.1% of the patients at discharge and in 69.4% of the patients at 1 year. 1-year outcomes of SAVR with the Perceval sutureless valve in Japanese patients were favorable. This valve offers a promising alternative to conventional biological AVR in this Japanese population.
Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Humanos , Femenino , Anciano , Masculino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Pueblos del Este de Asia , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Vigilancia de Productos Comercializados , Resultado del TratamientoRESUMEN
Globalization in Asia and consequent strengthening of healthcare economic factors in tandem with an increasing heart failure (HF) population have enhanced potential for development and progress in the fields of HF medicine and mechanical circulatory support (MCS). In Japan, there are unique opportunities to investigate the outcome of acute and chronic MCS and a national registry for percutaneous and implantable left ventricular assist device (LVAD) including Impella pumps has been established. A Peripheral extracorporeal membrane oxygenation (ECMO) for acute MCS has been used in more than 7000 patients annually and Impella usage in more than 4000 patients over the past 4 years was noted. Recently, a novel centrifugal pump with hydrodynamically levitated impeller was developed and approved for mid-term extracorporeal circulatory support. In terms of chronic MCS more than 1200 continuous flow LVADs have been implanted during the past decade, and 2-year survival rate after primary LVAD implantation is 91%. Because of donor organ shortage, more than 70% of heart transplant recipients required LVAD support for more than 3 years and prevention and treatment of complications during long-term LVAD support have become important. Five important topics including hemocompatibility-related complications, LVAD infections, aortic valve insufficiency, right ventricular failure and cardiac recovery during LVAD support are discussed in this review for improving clinical outcomes. Findings from Japan will continue to provide useful information regarding MCS for the Asia-Pacific region and beyond.
Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Adulto , Japón/epidemiología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Resultado del TratamientoRESUMEN
Pump pocket infection (PPI) is a refractory condition that can cause lethal complications in patients with a left ventricular assist device (LVAD). We report a case of PPI after LVAD implantation for ischemic cardiomyopathy that was successfully treated with staged pump reimplantation into the left ventricular anterior wall with the pedicled omental transfer. Major modification of the pump implantation site might be a useful strategy for local infection control of severe PPI.
Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Isquemia Miocárdica , Humanos , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Isquemia Miocárdica/etiología , Epiplón , Estudios RetrospectivosRESUMEN
During continuous-flow left ventricular assist device (CF-LVAD) support, hemodynamic shear stress causes a burden on aortic valve (AV) leaflets, leading to de novo aortic insufficiency (AI). This study investigated the influence of preoperative hemodynamic parameters on de novo AI in CF-LVAD recipients. We reviewed 125 patients who underwent CF-LVAD implantation without concomitant AV surgery between 2005 and 2018. De novo AI was defined as moderate or severe AI in those with none or trivial preoperative AI. During mean 30 ± 16 months of CF-LVAD support, de novo AI-free rate was 86% and 67% at 1 and 2 years, respectively. Multivariable analysis showed that higher right ventricular stroke work index (RVSWI) (hazard ratio, 1.12 /g/m2/beat; 95% confidence interval, 1.00-1.20; p = 0.047) and trivial grade AI (hazard ratio, 2.8; 95% confidence interval, 1.2-6.4; p = 0.020) were independent preoperative risk factors for de novo AI. The longitudinal analysis using generalized mixed effects model showed that higher RVSWI was associated with continuous AV closure after LVAD implantation (Odd ratio, 1.20/g/m2/beat; 95% confidence interval, 1.00-1.43 /g/m2/beat; p = 0.047). Right heart catheterization revealed that preoperative RVSWI was positively correlated with postoperative pump flow index in patients with continuously closed AV (r = 0.44, p = 0.04, n = 22). Preoperative higher RVSWI was a significant risk factor for de novo AI following CF-LVAD implantation. In patients with preserved right ventricular function, postoperative higher pump flow may affect AI development via hemodynamic stress on the AV.
RESUMEN
Catheter-based micro-axial ventricular assist device Impella® (Abiomed, Danvers, MA) has been used in Japanese patients with drug-refractory acute heart failure (AHF) since 2017. This is the first interim analysis of the ongoing Japan Registry for Percutaneous Ventricular Assist Device (J-PVAD) to investigate the safety and efficacy of Impella support. Between October 2017 and January 2020, 823 Japanese patients, who were treated with the Impella 2.5, CP, or 5.0 pump, were enrolled. The primary endpoints were safety profiles and cumulative 30-day survival. Among them, 44.8% of patients were acute myocardial infarction with cardiogenic shock. The Impella pumps were unable to implant in 4 patients. The Impella 2.5, CP, and 5.0 pumps were used in 72.4%, 6.2%, and 16.6%, respectively, and mean support duration was 8.1 ± 10.2 days. Combination use of Impella and venoarterial extracorporeal membrane oxygenation (VA-ECMO) was applied for 387 patients (47.3%). Pump stop occurred 22 patients (2.7%). Major adverse events included hemolysis (11.2%), hemorrhage/hematoma (6.1%), peripheral ischemia (1.6%), and stroke (1.6%). The overall 30-day survival was 62.2%. Survival of patients with single Impella support was significantly higher than patients with Impella combined with VA-ECMO support (81.1% vs 49.6%; p < 0.01), who had lower blood pressure, lower left ventricular ejection fraction, and higher degree of inotropic support. Results suggest that short-term outcome of Impella support for Japanese patients was favorable with acceptable safety profiles.
Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Catéteres , Pueblos del Este de Asia , Insuficiencia Cardíaca/terapia , Japón , Sistema de Registros , Estudios Retrospectivos , Choque Cardiogénico/terapia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular IzquierdaRESUMEN
BACKGROUND: The objective of this study is to investigate the effect of preoperative diabetes on all-cause mortality and major postoperative complications among patients with continuous-flow left ventricular assist device (LVAD) by using data from a national database.MethodsâandâResults: The 545 study patients who underwent primary HeartMateII implantation between 2013 and 2019 were divided into 2 groups according to their diabetes mellitus (DM) status; patients with DM (n=116) and patients without DM (n=429). First, the on-device survival and incidence of adverse events were evaluated. Second, after adjusting for patients' backgrounds, the change of laboratory data in the 2 groups were compared. Overall, on-device survival at 1, 2, and 3 years was almost equivalent between the 2 groups; it was 95%, 94%, and 91% in patients without DM, and 93%, 91%m and 91% in patients with DM (P=0.468) The incidence of adverse events was similar between 2 groups of patients, except for driveline exit site infection in the adjusted cohort. Cox proportional hazards regression analysis revealed younger age (HR: 0.98 (95% confidence interval (CI): 0.97-0.99, P=0.001) and presence of DM (HR: 1.83 (95% CI: 1.14-2.88), P=0.016) as significant predictors of driveline infection. Laboratory findings revealed no differences between groups throughout the periods. CONCLUSIONS: The clinical results after LVAD implantation in DM patients were comparable with those in non-DM patients, except for the driveline exit site infection.
Asunto(s)
Diabetes Mellitus , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Japón/epidemiología , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
BACKGROUND: The superiority of a fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) in terms of overall survival, stroke events and pump thrombosis has been demonstrated in previous international analyses, so we evaluated a Japanese cohort for the same.MethodsâandâResults: This retrospective observational study was conducted at Osaka University Medical Hospital and the National Cerebral and Cardiovascular Center in Japan. A total of 75 consecutive patients who underwent HeartMate3 (HM3) implantation were included. The primary endpoint was on-device survival, and the secondary endpoint was the incidence of LVAD-related complications at 2 years. All parameters were compared with those of the previously performed HeartMate II (HMII) implantation in 197 cases. The on-device survival rates were 94.7% and 92.3% in the HM3 and HMII groups, respectively, at the 2-year follow-up (P=0.62). The rehospitalization-free rate after implantation was 61.8% in the HM3 group, which was significantly higher than that in the HMII group (relative risk, 0.35; 95% confidence interval [CI], 0.23-0.55; P<0.0001). Event-free survival rates from cerebral cerebrovascular events and pump thrombosis in the HM3 group were significantly higher than those in the HMII group, at 97.2% and 100%, respectively (relative risk, 0.14; 95% CI 0.03-0.58); P=0.0015 and relative risk, not calculated; P=0.049, respectively). CONCLUSIONS: Satisfactory short-term outcomes were observed after HM3 implantation in a Japanese cohort.
Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Japón/epidemiología , Accidente Cerebrovascular/complicaciones , Trombosis/etiología , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
We evaluated the cardiac function recovery following skeletal myoblast cell-sheet transplantation and the long-term outcomes after applying this treatment in 23 patients with ischemic cardiomyopathy. We defined patients as "responders" when their left ventricular ejection fraction remained unchanged or improved at 6 months after treatment. At 6 months, 16 (69.6%) patients were defined as responders, and the average increase in left ventricular ejection fraction was 4.9%. The responders achieved greater improvement degrees in left ventricular and hemodynamic function parameters, and they presented improved exercise capacity. During the follow-up period (56 ± 28 months), there were four deaths and the overall 5-year survival rate was 95%. Although the responders showed higher freedom from mortality and/or heart failure admission (5-year, 81% versus 0%; p = 0.0002), both groups presented an excellent 5-year survival rate (5-year, 93% versus 100%; p = 0.297) that was higher than that predicted using the Seattle Heart Failure Model. The stepwise logistic regression analysis showed that the preoperative estimated glomerular filtration rate and the left ventricular end-systolic volume index were independently associated with the recovery progress. Approximately 70% of patients with "no-option" ischemic cardiomyopathy responded well to the cell-sheet transplantation. Preoperative renal and left ventricular function might predict the patients' response to this treatment.
Asunto(s)
Cardiomiopatías/terapia , Insuficiencia Cardíaca/terapia , Mioblastos/trasplante , Isquemia Miocárdica/terapia , Cardiomiopatías/genética , Cardiomiopatías/patología , Femenino , Corazón/crecimiento & desarrollo , Corazón/fisiopatología , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/patología , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/genética , Isquemia Miocárdica/patología , Volumen Sistólico/genética , Trasplante Autólogo/efectos adversos , Trasplante Autólogo/métodos , Función Ventricular Izquierda/genéticaRESUMEN
There have been no reports regarding the influence of a change in the pulmonary artery index before or after a Fontan operation. Moreover, the factors that might affect the change in the pulmonary artery index are unclear. This was a retrospective study, which included 94 patients who underwent a Fontan operation. We divided the patients into two groups according to the change in the pulmonary artery index before and after the Fontan operation: the increased pulmonary artery index group (n = 51) and decreased pulmonary artery index group (n = 43). The pulmonary artery index after the Fontan operation was significantly higher in the increased pulmonary artery index group than decreased pulmonary artery index group (p < 0.0001). The central venous pressure (p < 0.0001) and pulmonary vascular resistance (p = 0.007) were significantly lower in the increased pulmonary artery index group. The mixed venous oxygen saturation was significantly higher in the increased pulmonary artery index group (p < 0.0001). The pulmonary artery index was more increased in the patients who were administered a phosphodiesterase type 5 inhibitor than in those who were not (p = 0.03). The change in the pulmonary artery index reflected the hemodynamics after a Fontan operation during the short term. In that respect, phosphodiesterase type 5 inhibitors might be involved in the process.
Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Procedimiento de Fontan/efectos adversos , Cardiopatías Congénitas/cirugía , Hemodinámica , Humanos , Inhibidores de Fosfodiesterasa 5/uso terapéutico , Arteria Pulmonar/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
We describe a case in which an axillary Impella 5.0, stuck in an area of calcification in the right subclavian artery, could not be retrieved in the usual manner. However, it was successfully removed using a long 22-Fr sheath and snaring catheter by means of the trans-femoral artery. Device retrieval using the trans-femoral artery snare technique is considered a valid option for removing the Impella device in patients who exhibit this complication.
RESUMEN
Women with implantable left-ventricular assist devices (LVADs) experience gynecological bleeding (GYN-bleeding). However, a few studies have investigated female-specific problems. Therefore, this study aimed to identify the risk factors for adverse GYN-bleeding after LVAD implantation. We retrospectively analyzed 59 women (mean age: 41 ± 15 years) with long-term implantable LVAD support (≥ 6 months) at our institution between 2005 and 2018. The history of GYN-bleeding before implantation was defined as abnormal utero-ovarian bleeding, excessive menstruation, uterine fibroids, and endometrial lesions. GYN-bleeding after implantation was defined as a requirement of emergency outpatient visits and/or hospitalization, blood transfusions, hormonal therapy, and/or surgery. Additionally, risk factors for GYN-bleeding were identified using the Cox regression model. Twenty-four GYN-bleeding cases were seen in 15 patients (two times: five patients, three times: two patients, 0.18 events per patient-year). The 1- and 2-year GYN-bleeding-free rates were 84% and 73%, respectively. Twelve patients (17 events) required RBC ≥ 4 units, and five patients (7 events) required FFP ≥ 4 units. Seven patients required pseudomenopausal treatment after blood transfusion, and four patients required surgical treatment. Fifteen patients with GYN-bleeding after implantation were significantly younger than the remaining 44 patients without GYN-bleeding (34 ± 12 years vs. 43 ± 16 years, P = 0.02). Multivariable risk analysis showed a history of GYN-bleeding before implantation was a significant risk factor (hazard ratio 3.7 [1.2-10.6], P = 0.004). Patients with a history of GYN-bleeding before LVAD implantation have a high risk of developing GYN-bleeding after implantation. We should identify the high-risk population and prepare for the management of GYN-bleeding.
Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Hemorragia/etiología , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Resultado del TratamientoRESUMEN
Geometric changes caused by volume reduction early after aortic valve replacement (AVR) for aortic regurgitation (AR) may not be uniform, resulting in varying regional end-systolic wall stress (ESS). This study compared changes in regional ESS between AR and aortic stenosis (AS) patients in the early phase following AVR. Computer-tomographic left ventricular (LV) angiography was performed for 10 patients with AR and 13 with AS before and three months after AVR. Regional ESS at the base, middle, and apex levels, each subdivided into four segments, was calculated based on the Janz equation: ESS = end-systolic LV pressure × local cross-sectional area of LV cavity/that of LV wall. Following AVR, median LV end-diastolic volume index fell from 106 to 69 ml/m2 (P = 0.001) in AR and 60 to 46 ml/m2 (P = 0.01) in AS patients. Global ESS also declined in both (AR, 186 to 124 kdyne/cm2, P = 0.02; AS, 187 to 108 kdyne/cm2, P < 0.001, respectively). Regional ESS was reduced in all segments in AS patients, accompanied by left ventricular ejection fraction (LVEF) improvement (71-80%, P = 0.02). In contrast, regional ESS in AR patients was heterogeneously reduced, as regional ESS fell significantly in the antero-septal wall but was unchanged in the infero-lateral wall, and LVEF remained unchanged (65 to 62%, P = 0.42). In the early postoperative phase after AVR, the loading condition of the regional LV wall in AR patients was characterized by a heterogeneous reduction in regional ESS in contrast to a uniform decline in AS patients.