Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
BMC Vet Res ; 20(1): 338, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085867

RESUMEN

BACKGROUND: Reduction of inflammation and early detection of complications after surgical procedures are important objectives for proper veterinary practice. This study aimed to evaluate the differences between shelter and pet female cats in selected acute-phase parameters scheduled to ovariohysterectomy. Postoperative monitoring after ovariohysterectomy with the same laboratory parameters was performed in shelter cats, in which two different types of surgical sutures were used for the entire procedure. The experimental group comprised 40 female cats from animal shelters ('shelter cats,' n = 40). These cats were divided into two subgroups: group A (n = 20) operated on with absorbable sutures and group NA (n = 20) operated on with non-absorbable sutures. In addition, the same parameters were evaluated in pet female cats (n = 19). Blood was collected from shelter cats immediately before surgery (term 0), at 24 and 72 h (terms 1 and 3, respectively), and at 7 and 14 days (terms 7 and 14, respectively) after ovariohysterectomy. Blood samples from the pet cat group were collected only once. RESULT: The mean haptoglobin concentration before ovariohysterectomy in pet cats was significantly lower than that in shelter cats. Fibrinogen concentration was significantly lower in pet cats than in cats from group A. Serum albumin, beta-1, beta-2, and gamma-globulin concentrations were significantly higher in the shelter cats than in the pet cats. Subcutaneous tissue thickening at the site of the postoperative wound was observed in five patients cats (25%) in group A, and two (10%) cats in the NA group. CONCLUSION: These results indicate that ovariohysterectomy leads to local and general inflammatory responses. The majority of cats from animal shelters suffered from subclinical inflammation.


Asunto(s)
Histerectomía , Ovariectomía , Animales , Gatos/cirugía , Femenino , Histerectomía/veterinaria , Ovariectomía/veterinaria , Suturas/veterinaria , Técnicas de Sutura/veterinaria , Fibrinógeno/análisis , Haptoglobinas/análisis , Periodo Posoperatorio
2.
Animals (Basel) ; 14(4)2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38396505

RESUMEN

(1) Background: Anatomically pre-contoured plates usually require only minimal or even no intraoperative contouring. For complex cases, such plates also assist the surgeon as an anatomical template during fracture reduction. In this study, we present our experience of using a 3D printing technology for the treatment of bicondylar humeral fractures in feline cadavers. (2) Methods: Surgeries were performed on 15 pairs of front limbs amputated at the scapula. The limbs were obtained from 15 adult cats without obvious pathology of the skeleton. After flexion of the elbow and subperiosteal elevation of the anconeus muscle, the humeral Y-T fractures were created using a bone chisel and mallet. A custom-made anatomically pre-contoured interlocking plate was used to reduce and stabilise the medial aspect of the humeral condyle to the humeral diaphysis. After reduction of the humeral condyle, a positional locking screw was then inserted from the medial to the lateral side and a straight 2.4/2.7 interlocking bone plate was used to stabilise the lateral part of the condyle to the humeral diaphysis. (3) Results: The length of the humerus ranged from 98.2 to 107.0 mm and did not differ significantly between the left and right bone. The diameter of the isthmus of the humeral condyle ranged from 5.2 to 5.5 mm and did not differ significantly between the left and right bone. In all 30 limbs, bicondylar fracture was accompanied by epicondylar comminution. In 7/30 limbs (4 left, 3 right) the fracture of the humeral shaft was also present. In the left limbs, the postoperative articular surface defect of the humeral condyle was small (<1 mm) in 11/15 cases, moderate (1-2 mm) in 2/15 cases and large (>2 mm) in 2/15 cases in which the condylar screw was incorrectly inserted. In the right limbs, the postoperative articular surface defect of the humeral condyle was small (<1 mm) in 14/15 cases and moderate (1-2 mm) in 1 case. (4) Conclusions: 3D printing and the technology of metal powder sintering offers a wide range of possibilities for the development of new surgical implants. The anatomically pre-contoured bone plate appears to be a valuable tool in the reduction and stabilisation of Y-T humeral fractures in adult domestic cats weighing 3.0 to 4.5 kg.

3.
Animals (Basel) ; 14(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38731385

RESUMEN

(1) Background: Due to the unique structural and functional characteristics of the forelimb in cats, fractures of the radius and ulna are best repaired using internal fixation and stabilization in accordance with AO principles. This study presents the results of reduction of 42 cadaveric comminuted feline radial fractures reduced by minimally invasive plate osteosynthesis (MIPO). (2) Methods: Radius fractures were created on 21 pairs of forelimbs with intact bones. MIPO was then performed using two locking bone plates pre-contoured on 3D-printed bone models of the antebrachium of a male and a female cat. Pre- and postoperative radiographs were taken, and radius length and anatomical lateral distal radial angle (aLDRA) were measured. (3) Results: All fractures were classified as complex diaphyseal fractures of the radius. The radial bone length did not change significantly after surgery (F1,18 = 0.01, p = 0.933). However, the aLDRA was modified after surgery (F1,18 = 7.51, p = 0.013), but this change was only observed in females, in whom the aLDRA was significantly reduced (p = 0.035) compared to the value determined by the shape of the plate. In males, the pre- and postoperative aLDRA values were similar (p = 0.824). In 40 cases, alignment, adjacency of bone fragments, and apparatus were judged to be satisfactory. In two cases, the plate was fixed to the proximal radius and distal ulna due to misidentification of the distal radius. In both cases, revision surgery and correct fixation of the radius gave proper alignment, adjacency, and apparatus. (4) Conclusion: A pre-contoured plate on a 3D-printed model of the male and female domestic cat antebrachium was suitable for the reduction and stabilization of comminuted radial fractures in a cohort of domestic cat cadavers without the need to print individual antebrachial bone models for each patient.

4.
Animals (Basel) ; 13(16)2023 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-37627358

RESUMEN

A suitable wound retraction is crucial for open surgical treatment of chylothorax in dogs. A single paracostal approach for transabdominal/transdiaphragmatic thoracic duct ligation and cisterna chyli ablation is an effective procedure. For the procedure, the use of stay sutures and handheld or automatic soft tissue retractors is recommended. However, it is often necessary to adjust the retractors several times during the surgery to provide sufficient exposure of the thoracic duct. This prolongs the operation and increases infection risk. In this report, we describe the modified application of two o-ring elastic wound retractors (O-WRs) in three large breed dogs with idiopathic chylothorax. We conclude that the O-WRs provide a static circumferential vision of the operation field and good access to the cisterna chyli, especially to the thoracic duct. The usage of other surgical instruments is not hampered by the O-WRs, and the elastic rings are not damaged by the metal instruments. Once placed in the diaphragmatic area, indeed, they do not require further manual retraction.

5.
Animals (Basel) ; 13(23)2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-38066943

RESUMEN

While the insertion of the arthroscope into the elbow joint is relatively easy based on anatomical landmarks, obtaining a correctly located instrument portal is often difficult. Therefore, the goal of the study was to create a 3D-printed prototype of an aiming device for the guiding needle, and to check its feasibility. The study included fresh cadavers of 15 dogs, 9 males and 6 females, aged from 1 to 6 years (median 4 years) with body weight from 17 to 57 kg (median 30 kg). On each dog, we compared the number of attempts needed to obtain optimal direction of the guiding needle for the portal, using one elbow the prototype, and performing this as control on the opposite joint without the prototype (with a free hand). The number of attempts needed was significantly lower using the prototype (median 1) than on the control elbows (median 2, p = 0.009). The number of attempts was not correlated with the body weight neither in the case of experimental (Rs = 0.18, p = 0.532) nor control elbows (Rs = 0.13, p = 0.642). We conclude that the used prototype seems to be helpful in elbow joint arthroscopy.

6.
Animals (Basel) ; 13(12)2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37370514

RESUMEN

Laparotomic attenuation of an intrahepatic portosystemic shunt (IHPSS) is more difficult than an extrahepatic one, and results in a higher risk of complications because the identification of the aberrant vessel in the liver remains often a challenge. Excessive preparation and traction of the parenchyma results in trauma, bleeding, and prolonged surgery, which is what worsens the prognosis. Therefore, based on computed tomographic angiography, we printed 3-dimensional (3D) individual patient liver models, scaled 1:1, and used them for surgery planning and as a guide during intraoperative identification of the shunt in four dogs with IHPSS. The advantages of the 3D technology are simple and precise planning of the surgery, fast intraoperative identification of the shunt, and low invasive dissection of the liver parenchyma. We conclude that 3D technology can potentially raise the recovery rate. To the best of our knowledge, this was the first application of 3D models in the surgery of canine IHPSS.

7.
Animals (Basel) ; 13(22)2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38003199

RESUMEN

This study included 10 fresh adult cadavers of large breed dogs (6 males and 4 females). Their weight ranged from 25 to 45 kg (mean ± SD: 33.9 ± 6.2 kg). The breeds represented were crossbreed dogs (n = 5), German shepherds (n = 2), Bernese mountain dogs (n = 1), American Staffordshire terriers (n = 1), and Gordon setters (n = 1). Access to the target area and identification of the femoral head and neck was achieved with two Gelpi retractors inserted orthogonally and with the O-WR in all procedures. In each dog, the approach to the hip joint was made on the left and right sides. There was no significant difference in the area of the surgical wound bed between the two sides using either the Gelpi retractors (-0.52 ± 1.87 cm2; CI 95%: -1.86, 0.81 cm2; p = 0.398) or the O-WR (-0.27 ± 2.34 cm2; CI 95%: -1.94, 1.41 cm2; p = 0.729). The area of the surgical wound bed was 6.28 ± 1.72 cm2 (2.72-9.70 cm2) for the Gelpi retractors and 6.34 ± 1.81 cm2 (4.13-10.77 cm2) for the O-WR, and the difference between the Gelpi retractors and the O-WR was not significant (-0.06 ± 1.72 cm2; CI 95%: -0.86, 0.74 cm2; p = 0.879).

8.
Animals (Basel) ; 14(1)2023 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-38200797

RESUMEN

The aim of this study was to compare the degree of visibility of the lateral and medial menisci before and after tibial plateau leveling osteotomy (TPLO) on 3D-printed models created after laser scanning of the right tibia with menisci derived from a fresh cadaver of a 4-year-old adult male golden retriever. The models were produced of white polylactic acid, and the menisci were filled with light-curing red resin. The models showed a similar conformation as the natural specimen harvested from the cadaver, maintaining the same length and width, in addition to reproducing the anatomical structures. From the pre- and post-TPLO radiographs, it was possible to identify the anatomical structures corresponding to the tibial plateau. The preoperative tibial plateau angle was 26.2°, and the postoperative one ranged between 4.0° and 5.3° (4.6 ± 0.4°). In the bird's-eye photo, the total number of red pixels in the lateral and the medial meniscus was 2,053,995 and 2,140,939, respectively. Before TPLO, only between 14% and 19% of the entire area of the menisci was visible, and the unhidden part of the entire area of the meniscus before TPLO did not differ significantly between the lateral (16.2 ± 1.6%) and the medial (16.4 ± 1.6%) meniscus (p = 0.351). The visible part of the entire meniscus area increased significantly after TPLO both in the lateral and medial menisci (p < 0.001)-mean difference ± SD of 30.3 ± 4.3% (CI 95%: 27.9%, 32.6%) and 36.4 ± 6.4% (CI 95%: 32.9%, 40.0%), respectively. In conclusion, the intraoperative examination and treatment of dog menisci are easier after TPLO.

9.
Front Cardiovasc Med ; 10: 1111651, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37424902

RESUMEN

Introduction: In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model. Methods: Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection. Results: Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40 s. Discussion: This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective.

10.
J Vet Res ; 63(2): 243-249, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31276064

RESUMEN

INTRODUCTION: The clinical symptoms of portosystemic shunts (PSSs) and hepatic microvascular dysplasia (HMD) - portal vein hypoplasia (PVH) in dogs are similar. PSSs are abnormal vascular connections between the portal vein system and systemic veins. HMD is a very rare developmental vascular anomaly, recognisable during histopathological examination. The study aim was to assess the prevalence of HMD-PVH and hepatocellular and vascular pathologies in the liver. MATERIAL AND METHODS: Liver biopsies from 140 dogs (of different breeds and both sexes) arousing clinical suspicion of PSS were examined histopathologically. RESULTS: An initial PSS diagnosis was confirmed in 125 dogs (89.29%). HMD-PVH was found in 12.32% of dogs, as an isolated disease in 9.29%, especially in Yorkshire terriers, and with extrahepatic PSS in 6.67%. Histopathological analysis of muscles around sublobular veins showed that HMD cases presented hypertrophy or hypertrophy with fibrosis. In 2.17% of all dogs with liver vascular developmental disorders calcification was visible around vessels (without correlation by degenerative changes in those vessels), suggesting prior onset of deep metabolic disorders. Clinical suspicion of PSS was also formed upon quite different pathological processes in young dogs. CONCLUSION: Histopathological findings diagnosed the type of vascular anomalies (PSS or HMD-PVH) or other pathological changes conclusively, therefore detailed hepatic histopathology is an indispensable component of the clinical diagnostic process.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA