Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(1): 35-46, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37199171

RESUMEN

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Aleteo Atrial/etiología , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
J Cardiovasc Electrophysiol ; 34(11): 2382-2385, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37679961

RESUMEN

BACKGROUND: Dual occlusive closure mechanism (disc and lobe type), Amulet device (Abbott; a second-generation device that has replaced Amplatzer Cardiac Plug) was approved by the Food and Drug Administration (FDA) in August 2021 for percutaneous left atrial appendage occlusion (LAAO). However, real-world safety data on the delivery system (Amplatzer Cardiac Plug and Amplatzer Amulet device) are lacking. OBJECTIVE: We sought to assess the type of adverse events associated with the Amplatzer LAAO delivery system using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: A MAUDE database search was conducted on March 31, 2023, for reports received between February 2013 and March 2023 to capture all adverse events. RESULTS: A total of 59 adverse events were reported, of which 58 were sheath-related events, and one was a wire-related event. The most commonly encountered issue was air embolism (19%, 11 events), followed by sheath thrombosis (13.8%, eight events, two of which were also associated with device thrombosis), kinked sheath (10.3%, six events), and sheath deformation (8.6%, five events). Patient-related adverse events included pericardial effusion requiring pericardiocentesis (22.4%, 13 events), vascular complications (20.7%, 12 events), and device dislodgement (5.2%, three events). CONCLUSION: LAAO-related adverse events are increasingly being reported using the Amplatzer LAAO delivery sheath. It is anticipated that improvements in device technology, the advent of steerable sheaths, and operator experience will minimize these complications.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Trombosis , Estados Unidos , Humanos , Apéndice Atrial/diagnóstico por imagen , United States Food and Drug Administration , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/efectos adversos , Trombosis/etiología , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversos
3.
J Cardiovasc Electrophysiol ; 34(6): 1469-1471, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37209414

RESUMEN

BACKGROUND: Leadless pacemaker (LP) offers an innovative approach for treating bradyarrhythmia, thus avoiding pacemaker pocket and lead-related complications. The Food and Drug Administration (FDA) has recently approved the Aveir™ leadless pacing system (screw-in type LP). METHODS: We queried the FDA MAUDE database to study the safety profile and assess the types of complications with this relatively novel device technology. A MAUDE database search was conducted on January 20, 2023, for reports received post-FDA approval to capture all adverse events. RESULTS: A total of 98 medical device report were reported for Aveir™ LP. After excluding duplicate, programmer-related, or introducer-sheath-related entries (n = 34), 64 entries were included. The most commonly encountered problem was high threshold/noncapture (28.1%, 18 events), followed by stretched helix (17.2%, 11 events) and device dislodgement (15.6%, ten events-5 intraprocedural, while 5 in the postoperative Day 1). Other reported events included high impedance (14.1%, nine events), sensing issues (12.5%, eight events), bent/broken helix (7.8%, five events), premature separation (4.7%, three events), interrogation problem (3.1%, two events), low impedance (3.1%, two events), premature battery depletion (1.6%, one event) and inadvertent MRI mode switch (1.6%, one event) and miscellaneous (15.6%, n = 10). There were eight serious patient injury events-pericardial effusion requiring pericardiocentesis (7.8%, five events) due to cardiac perforation that resulted in two deaths (3.1%) followed by sustained ventricular arrhythmias (4.6%, n = 3). CONCLUSION: In our study assessing the real-world safety profile of the Aveir™ LP, serious adverse events have been reported-life-threatening ventricular arrhythmias, pericardial effusion, device explantation/reimplantation, and death.


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Realidad Virtual , Estados Unidos , Humanos , United States Food and Drug Administration , Derrame Pericárdico/etiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Marcapaso Artificial/efectos adversos
4.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36950852

RESUMEN

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Fibrilación Atrial/complicaciones , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/complicaciones , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos
5.
J Cardiovasc Electrophysiol ; 33(2): 308-314, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34845805

RESUMEN

BACKGROUND: Increasing interest in physiological pacing has been countered with challenges such as accurate lead deployment and increasing pacing thresholds with His-bundle pacing (HBP). More recently, left bundle branch area pacing (LBBAP) has emerged as an alternative approach to physiologic pacing. OBJECTIVE: To compare procedural outcomes and pacing parameters at follow-up during initial adoption of HBP and LBBAP at a single center. METHODS: Retrospective review, from September 2016 to January 2020, identified the first 50 patients each who underwent successful HBP or LBBAP. Pacing parameters were then assessed at first follow-up after implantation and after approximately 1 year, evaluating for acceptable pacing parameters defined as sensing R-wave amplitude >5 mV, threshold <2.5 V @ 0.5 ms, and impedance between 400 and 1200 Ω. RESULTS: The HBP group was younger with lower ejection fraction compared to LBBAP (73.2 ± 15.3 vs. 78.2 ± 9.2 years, p = .047; 51.0 ± 15.9% vs. 57.0 ± 13.1%, p = .044). Post-procedural QRS widths were similarly narrow (119.8 ± 21.2 vs. 116.7 ± 15.2 ms; p = .443) in both groups. Significantly fewer patients with HBP met the outcome for acceptable pacing parameters at initial follow-up (56.0% vs. 96.4%, p = .001) and most recent follow-up (60.7% vs. 94.9%, p ≤ .001; at 399 ± 259 vs. 228 ± 124 days, p ≤ .001). More HBP patients required lead revision due to early battery depletion or concern for pacing failure (0% vs. 13.3%, at a mean of 664 days). CONCLUSION: During initial adoption, HBP is associated with a significantly higher frequency of unacceptable pacing parameters, energy consumption, and lead revisions compared with LBBAP.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Estimulación Cardíaca Artificial/efectos adversos , Electrocardiografía , Humanos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
6.
Rev Cardiovasc Med ; 23(1): 34, 2022 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-35092226

RESUMEN

BACKGROUND: Perioperative anticoagulation management with uninterrupted or minimally interrupted anticoagulation during atrial fibrillation (AF) ablation is thought to be critical to minimize thromboembolic complications. Protamine is often administered to neutralize the effects of heparin and expedite vascular hemostasis post-procedure. OBJECTIVE: We performed a systematic review and meta-analysis to determine the effectiveness of protamine to expedite vascular hemostasis and ambulation in patients undergoing AF ablation. METHODS: Electronic searches on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from the inception through August 7, 2021, were performed. The primary outcomes included-time to hemostasis (minutes) and time to ambulation (minutes). The secondary outcomes included - any vascular complications (excluding minor hematoma), minor hematoma, or cerebrovascular accidents (CVA). RESULTS: A total of 5 eligible studies (3 retrospective cohort studies and two randomized trials) consisting of 1012 patients (515 patients received protamine group and 497 patients did not receive protamine group) were included in the meta-analysis. There was a significant reduction in time to ambulation [weighted mean difference (WMD) -176.6 minutes, 95% Confidence interval (CI) -266.9 to -86.3; p < 0.01] and time to hemostasis (WMD -13.72 minutes, 95% CI -22 to -5.4, p < 0.01) in the protamine group compared to the contrary. At a follow-up up to 3 months, there was no statistical difference between the two groups with regards to vascular complications (2.9% vs. 7.4%; Risk ratio (RR) 0.46 95% CI 0.17 to 1.24; p = 0.12), minor hematoma (2.1% vs. 5.8%; RR 0.43, 95% CI 0.16 to 1.2; p = 0.11) or CVA (0 vs. 0.3%; RR 0.62, 95% CI 0.08 to 4.98; p = 0.65). CONCLUSION: Protamine administration was associated with reduced time to ambulation (176 minutes reduction) and time to hemostasis (13 minutes reduction) without an increase in any adverse events.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Protaminas/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
8.
Pacing Clin Electrophysiol ; 45(4): 567-570, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35199863

RESUMEN

BACKGROUND: Thromboembolic (TE) events are among the most common and devastating adverse events in patients with continuous-flow left ventricular assist device (cf-LVAD). Given the high burden of AF among cf-LVAD patients, we sought to evaluate the effect of concomitant surgical LAAO in patients receiving cf-LVAD. METHODS: A systematic search using electronic databases was performed using the keywords: "left atrial appendage occlusion" and "left ventricular assist device." Statistical analysis was performed using metapackage for R version 4.0 and Rstudio version 1.2. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data between two groups. The primary outcomes included: (a) stroke; (b) LVAD pump thrombosis; (c) all-cause mortality RESULTS: Three studies with a total of 305 patients (LAAO = 68 and No-LAAO = 237) were included in the analysis. HeartMate II (39%) and Heartware (27.5%) were the two most common cf-LVADs utilized, while only 5% received HeartMate III. At a mean follow up of 1.47 years, LAAO group had a lower risk of stroke (8.8% vs. 15.2%, RR 0.64; 95% CI 0.28-1.49), LVAD pump thrombosis (1.5% vs. 3.8%, RR 0.28; 95% CI 0.05-1.55) and all-cause mortality (5.9% vs. 20.2%, RR 0.69; 95% CI 0.19-2.52) when compared with no-LAAO group, but the difference did not reach statistical significance. CONCLUSION: Concomitant surgical LAAO at the time of cf-LVAD implantation demonstrated a trend toward positive outcomes and was not associated with adverse outcomes during the follow-up period, though the results were not statistically significant.


Asunto(s)
Apéndice Atrial , Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Tromboembolia , Trombosis , Apéndice Atrial/cirugía , Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/complicaciones , Tromboembolia/etiología , Trombosis/etiología , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 32(6): 1764-1771, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33772939

RESUMEN

INTRODUCTION: Though current guidelines currently recommend using warfarin, there is also a growing interest in the utilization of direct oral anticoagulants (DOACs) to treat left ventricular (LV) thrombus. METHODS: We performed a systematic search using PubMed, SCOPUS, EMBASE, Google Scholar, and ClinicalTrials.gov from inception to September 30, 2020, for studies that had reported outcomes in patients with left ventricular thrombus treated with DOACs (PROSPERO registration number CRD42020219761). RESULTS: Twelve studies (n = 867 patients) were included in the analysis. The pooled incidence of the systemic embolic events (SEE) with DOACs was 2.7%, whereas the thrombus resolution rate was 86.6%. The pooled incidence of overall bleeding (composite of major and minor bleeding) and major bleeding with DOACs were 5.6% and 1.1%, respectively. No significant difference was observed in terms of SEE (OR 0.81, 95% confidence interval [CI] 0.44-1.52, p = .54), major bleeding (OR 0.29, 95% CI 0.07-1.26, p = .24), and failure of LV thrombus resolution (OR 0.86, 95% CI 0.28-2.58, p = .68); whereas overall bleeding was significantly low in patients with LV thrombus treated with DOACs compared to vitamin K antagonists (VKAs) (OR 0.33, 95% CI 0.14-0.81, p = .02). CONCLUSION: Our study demonstrates no significant difference in SEE, major bleeding, or failure of LV thrombus resolution between the two groups, thus demonstrating that DOACs are an efficacious and safe alternative for the treatment of LV thrombus compared to VKAs. However, further well-designed prospective trials are needed to answer important clinical questions-optimal dosing/duration of DOACs and its safety in the background of antiplatelet therapy.


Asunto(s)
Trombosis , Vitamina K , Administración Oral , Anticoagulantes/efectos adversos , Humanos , Estudios Prospectivos , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico
10.
J Cardiovasc Electrophysiol ; 32(9): 2595-2600, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34379349

RESUMEN

INTRODUCTION: The role of secondary prevention implantable cardioverter-defibrillator (ICD) remains uncertain in spontaneous coronary artery dissection (SCAD) patients presenting with sudden cardiac arrest (SCA). METHODS: We aimed at assessing the outcomes following SCA and the role of ICD therapy in SCAD. The meta-analysis was performed using a meta-package for R version 4.0/RStudio version 1.2 and the Freeman-Tukey double arcsine method to establish the variance of raw proportions. Outcomes measured included-(1) incidence of ICD implantation, (2) appropriate and inappropriate ICD therapy, (3) recurrence of SCAD and SCA, and (4) all-cause mortality. RESULTS: Five studies, including 139 SCAD patients with SCA met study inclusion criteria. The mean age was 47.3 ± 12.8 years, mean left ventricular ejection fraction 43.8 ± 10.8%, 88% were female (12% had pregnancy-associated SCAD. Causes of SCA included ventricular arrhythmia (97.9%, n = 136) and pulseless electrical activity (2.1%, n = 3). Overall, 20% patients (95% confidence interval [CI]: 7.1%-36.6%, I2 = 68%) received ICD, of which 1.2% (95% CI: 0%-15.8%, I2 = 0%) and 1% (95% CI: 0%-15.3%, I2 = 0%) patients received appropriate and inappropriate ICD therapies, respectively, during follow-up period (4.1 ± 3.3 years). Incidence of recurrent SCAD was 9% (95% CI: 2.85%-17.5%, I2 = 25%), and recurrent SCA was 3.85% patients (95% CI: 0.65%-8.7%, I2 = 0%; one patient with appropriate ICD therapy). The pooled incidence of all-cause mortality was 6.2% (95% CI: 0.6%-15.1%, I2 = 44%). CONCLUSION: Although ICD therapy is beneficial in patients (all comers) presenting with cardiac arrest; the risk-benefit ratio of secondary prevention ICD arrest remains unclear. Patient-centered shared decision-making and risk-benefit ratio assessment should be performed before consideration for ICD implantation.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Adulto , Vasos Coronarios , Muerte Súbita Cardíaca/prevención & control , Disección , Femenino , Paro Cardíaco/diagnóstico , Paro Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Embarazo , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Función Ventricular Izquierda
11.
J Cardiovasc Electrophysiol ; 32(8): 2189-2198, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34164881

RESUMEN

INTRODUCTION: The LARIAT epicardial suture snaring device has been fraught with technical challenges and procedural complications. Over time, technique modification and improved operator experience have helped overcome many of these challenges. METHODS AND RESULTS: Studies reporting left atrial appendage epicardial closure over a 12-year period from 2009 to 2020 were evaluated. The primary efficacy outcome evaluated was left atrial appendage closure with residual flow ≤1 mm. Safety outcomes evaluated were periprocedural and long term complications after device placement. Nine studies consisting of 1430 patients were included in this analysis, of which 1386 (97%) underwent successful device placement. The mean age was 69.3 years, with a mean CHADS2 -VASC score of 3.78. Primary efficacy end point was achieved in 95.8% patients immediately after device placement, and in 92.8% patients on long term follow-up. Early procedural complications consisted of pericardial effusion 5.6%, cardiac perforation 2.7%, pericarditis 2.6%, and need for open heart surgery 1.5%. Long term complications consisted of all-cause mortality 2.3%, stroke 1.5%, and left atrial appendage thrombus 2.3%. Reduced complications were noted using micropuncture needles (2.20% vs. 10.14%; p < .0001), a longer duration pericardial drainage, and use of anti-inflammatory medications (1.58% vs. 8.4%). Oral anticoagulation use decreased from 44.7% to 22.9% post device implantation, and to 8.5% on last clinical follow up. CONCLUSIONS: The LARIAT device is effective in epicardial closure of the left atrial appendage. Improvement in device techniques such as use of micropuncture needle, prophylactic colchicine, and maintenance of a pericardial drain have helped improve safety over time.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Anciano , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Suturas , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 32(3): 717-725, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33533089

RESUMEN

BACKGROUND: The next-generation Watchman FLX left atrial appendage closure (LAAC) device has: (1) an atraumatic closed distal end, (2) reduced height, (3) a recessed screw hub to decrease device-related thrombus (DRT), (4) two rows of J-shape anchors so redeployment is possible after full recapture, and (5) ability to treat a greater size range of LAA ostia. OBJECTIVE: To report, for the first time, the feasibility and safety of intracardiac echocardiography (ICE)-guided Watchman FLX implantation. METHODS: A single-center prospective registry of atrial fibrillation patients planned for LAAC with the FLX device underwent ICE-guided implantation with conscious sedation. Transesophageal echocardiography (TEE) imaging was done preprocedure (to assess LAA size and exclude thrombus) and at clinical follow-up at 6-12 weeks. Clinical outcomes were LAA closure success, complications, leak, or DRT on follow-up TEE and major safety events. RESULTS: The study included 30 patients: age 75 ± 8 years, 53% men, CHA2 DS2 -VASc 4.6 ± 1.6, and HAS-BLED 3.4 ± 1.1. The primary indication was prior bleeding in 60% (72% GI bleeding). The LAA orifice width and length were 22.7 ± 3.1 and 25.7 ± 5.7 mm, respectively. Technical success was 100% (the first-choice device was used in 28 of 30). Procedure time was less than 30 min in 27 of 30 cases, with 36 ± 15 ml contrast used. The final device size was 29.2 ± 4.7 mm with 21.6 ± 4.5% compression. There were no procedure-related complications. Follow-up TEE at a median 47 days follow-up showed 100% device success with no DRT or peridevice leak ≥5 mm. Major safety events occurred in 6.6% (2/30). CONCLUSION: The Watchman FLX device can be safely implanted with intraprocedural ICE imaging instead of TEE.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 32(8): 2165-2170, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33942420

RESUMEN

OBJECTIVE: To assess the safety and efficacy of a novel immunosuppressive regimen-combination Methotrexate/Prednisone (cMtx/P)-in the management of severe refractory rPPP. METHODS: In this multicenter, nonrandomized, retrospective, observational study, 408 consecutive patients diagnosed with persistent rPPP between 2017 and 19 were included. Patients with refractory symptoms despite 3 months of conventional therapy were initiated on a 4-week regimen of oral steroids. Persistence of symptoms at this point, that is, rPPP (n = 25; catheter based = 18, open surgical = 7) prompted therapy with Methotrexate (7.5-15 mg weekly) with folate supplementation along with low dose prednisone (5 mg PO) for a further 3 months. Patients were followed for a total of 11.3 ± 1.8 months. RESULTS: Treatment refractory rPPP occurred in 6.1% of the study population prompting immunosuppressive therapy with cMtx/P. All patients demonstrated complete symptom resolution following 3 months of treatment with an 85% decline in clinically significant pericardial effusions. One patient developed recurrent pericarditis during the 11-month follow-up. Therapy was well tolerated with no significant drug related adverse effects. CONCLUSION: cMtx/P therapy is a safe and effective adjunct in the management of rPPP refractory to standard therapy.


Asunto(s)
Inmunosupresores , Pericarditis , Humanos , Inmunosupresores/efectos adversos , Metotrexato/efectos adversos , Pericarditis/inducido químicamente , Pericarditis/diagnóstico , Pericarditis/tratamiento farmacológico , Prednisona/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
14.
Europace ; 23(11): 1757-1766, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34151947

RESUMEN

AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía , Humanos , Terapia por Láser , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 44(5): 865-874, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33786832

RESUMEN

INTRODUCTION: Renal sympathetic denervation (RSDN) is an alternate management approach for refractory ventricular arrhythmias (VAs). We aimed to perform a systematic review of clinical outcomes on the impact of RSDN on refractory VA patients. METHODS: A systematic search without language restriction, using PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov from inception to August 18, 2020, was performed for the studies that reported outcomes in patients who underwent RSDN for VA. The outcomes studied were-(1) recurrent VA; and (2) all-cause mortality. RESULTS: Five studies (from 2014 to 2018) with a total of 51 VA patients met study inclusion criteria. The mean age was 61.92 ± 11.76 years, and 78.4% were men. The pooled incidence of short-term (3 months or less) and long-term (more than 3 months) VA recurrence was 63.85% (95% CI 16.75 to 99.32) and 10.52% (95% CI 0.14 to 28.75), respectively. When stratified by the number of VA episodes, there was a significant reduction in mean VA episodes (SMD -3.79, 95% CI -6.59 to -0.98, p < .01), ICD shocks (SMD -1.71, 95% CI -3.0 to -0.42, p < .01) and anti-tachycardia pacing (SMD -1.21, 95% CI -1.98 to -0.44, p < .01) following RSDN denervation. The pooled incidence of all-cause mortality after RSDN was 10.16% (95% CI 1.08 to 24.12). There were no major vascular complications, one minor vascular complication-small non-flow limiting renal artery dissection (no intervention needed). CONCLUSION: RSDN appears to be a safe and effective treatment strategy in patients with prior failed antiarrhythmic drugs and catheter ablation for recurrent ventricular arrhythmia and electrical storm.


Asunto(s)
Riñón/inervación , Simpatectomía , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/cirugía , Desfibriladores Implantables , Humanos , Recurrencia
16.
Pacing Clin Electrophysiol ; 44(7): 1236-1252, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34085712

RESUMEN

The thromboembolic complications of Atrial fibrillation (AF) remain a major problem in contemporary clinical practice. Despite advances and developments in anticoagulation strategies, therapy is complicated by the high risk of bleeding complications and need for meticulous medication compliance. Over the past few decades, the left atrial appendage has emerged as a promising therapeutic target to prevent thromboembolic events while mitigating bleeding complications and compliance issues. Emerging data indicates that it is a safe, effective and feasible alternative to systemic anticoagulation in patients with non-valvular AF. A number of devices have been developed for endocardial or epicardial based isolation of the left atrial appendage. Increasing experience has improved overall procedural safety and ease while simultaneously reducing device related complication rates. Furthermore, increasing recognition of the non-mechanical advantages of this procedure has led to further interest in its utility for further indications beyond the prevention of thromboembolic complications. In this review, we present a comprehensive overview of the evolution of left atrial appendage occlusion, commercially available devices and the role of this modality in the current management of AF. We also provide a brief outline of the landmark trials supporting this approach as well as the ongoing research and future prospects of left atrial appendage occlusion.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Tromboembolia/prevención & control , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/tendencias , Predicción , Humanos , Tromboembolia/etiología
17.
Pacing Clin Electrophysiol ; 44(4): 711-719, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33686695

RESUMEN

BACKGROUND: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is increasingly being considered. This study examined the barriers and financial impact associated with SDD in a contemporary cohort of patients undergoing elective AF ablation. METHODS: A single center retrospective review was conducted of the 249 first case-of-the-day outpatient AF ablations performed in 2019 to evaluate the proportion of patients that could have undergone SDD. Barriers to SDD were defined as any intervention that prevented SDD by 8 p.m. The financial impact of SDD was based on savings from avoidance of the overnight hospital stay and revenue related to management of chest pain facilitated by a vacant hospital bed. RESULTS: SDD could have occurred in 157 patients (63%) without change in management and in up to 200 patients (80%) if avoidable barriers were addressed. Barriers to SDD included non-clinical logistical issues (43%), prolonged post-procedure recovery (42%) and minor procedural complications (15%). On multivariate analysis, factors associated with barriers to SDD included increasing age (P = .01), left ventricular ejection fraction ≤ 35% (P = .04), and severely dilated left atrium (P = .04). The financial gain from SDD would have ranged from $1,110,096 (assuming discharge of 63% of eligible patients) to $1,480,128 (assuming 80% discharge) over the course of a year. CONCLUSIONS: Up to 80% of patients undergoing outpatient AF ablation were amenable to SDD if avoidable delays in care had been anticipated. Based on reduced hospital operating expenses and increased revenue from management of individuals with chest pain, this would translate to a financial savings of ∼$1.5 million.


Asunto(s)
Atención Ambulatoria/economía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Tiempo de Internación/economía , Alta del Paciente/economía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Retrospectivos
18.
Indian Pacing Electrophysiol J ; 21(4): 221-226, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33866017

RESUMEN

BACKGROUND: Warfarin is traditionally the drug of choice for stroke prophylaxis or treatment of venous thromboembolism in patients with end-stage renal disease (ESRD) on hemodialysis as data on apixaban use is scarce. We aimed to assess the safety and efficacy of Apixaban in patients with ESRD on hemodialysis when compared with warfarin. METHODS: A comprehensive literature search in PubMed, Google Scholar, and Cochrane databases from inception until Nov 25, 2019, was performed. Studies reporting clinical outcomes comparing Apixaban (2.5 mg BID or 5 mg BID) versus Warfarin in ESRD patients on hemodialysis were included. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data. RESULTS: Four studies (three retrospective and one randomized) with a total of 9862 patients (apixaban = 2,547, warfarin = 7315) met inclusion criteria. The overall mean age was 66.6 ± 3.9 years and mean CHA2DS2-VASc score 4.56 ± 0.58. Apixaban was associated with lower rates of major bleeding (RR 0.53, 95% CI 0.45-0.64, p < 0.0001], gastrointestinal (GI) bleed (RR 0.65, 95% CI 0.55-0.76, p < 0.0001), intracranial bleed (RR 0.56, 95% CI 0.36-0.89, p = 0.01), and stroke/systemic embolism [RR 0.65, 95% CI 0.52-0.83, p = 0.0004] compared with warfarin in patients with ESRD on hemodialysis. There was no significant increased risk of all-cause mortality with the apixaban vs. warfarin (RR 0.90, 95% CI 0.41-1.96, p = 0.78). CONCLUSION: Apixaban had an overall favorable risk-benefit profile, with significant reductions in ischemic stroke, major bleeding, and intracranial bleeding compared to Warfarin in ESRD patients on hemodialysis with non-valvular AF and/or venous thromboembolism.

19.
J Cardiovasc Electrophysiol ; 31(9): 2328-2334, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32530528

RESUMEN

INTRODUCTION: Transseptal puncture (TSP) is challenging in patients with prior percutaneous atrial septal defect (ASD) occluder. We aimed to perform a systematic review and meta-analysis of the safety and efficacy of catheter ablation for atrial fibrillation (AF) in patients with percutaneous ASD occluder. METHODS: We searched PubMed, Medline, Embase, Ovid, and Cochrane for studies reporting results of AF ablation (freedom from AF, fluoroscopy/procedure time, and complications) in patients with percutaneous ASD occluders. RESULTS: Three studies with a total of 64 patients met inclusion criteria. The success rate of TSP was 100%. All patients (but one) underwent TSP under fluoroscopic and intracardiac echocardiography guidance. Freedom from AF was achieved in 77.7% (95% confidence interval [CI]: 65.7-86.3) patients. In the subgroup analysis, comparing septal versus device puncture, no significant difference in recurrence of AF was observed (23.07% vs. 16.66%; risk ratio: 1.18; 95% CI: 0.35-4.00; p = .79, respectively). The total fluoroscopy time was not significantly different in patients with TSP via native septum or device (43.50 vs. 70.67 min; p = .44), total procedural time was significantly longer with TSP via the closure device (237.3 vs. 180 min; p = .004) compared with the native septum. There were no device dislodgement or residual interatrial shunt during the follow-up period. CONCLUSION: Catheter ablation for AF in patients with prior percutaneous ASD closure device is feasible and safe with favorable long-term outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Dispositivo Oclusor Septal , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Humanos , Punciones , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 31(7): 1822-1827, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32323386

RESUMEN

INTRODUCTION: Novel oral anticoagulants (NOACs) are commonly used for thromboembolic risk reduction and treatment of pulmonary embolism and deep venous thrombosis. However, data regarding their efficacy and safety in comparison to warfarin for left atrial appendage thrombus is limited. METHODS: A comprehensive literature search in PubMed, Google Scholar, and Cochrane Review from inception to 30 October 2019 was performed. Studies reporting clinical outcomes comparing warfarin vs NOACs were included. Two investigators independently extracted the data and individual quality assessment was performed. A meta-analysis was performed using random-effects model to calculate risk ratio (RR) and 95% confidence interval (CI). The analysis was performed using RevMan 5.3. RESULTS: Four studies met inclusion criteria and a total of 322 patients were included of whom 141 were in the NOAC arm and 181 were in the warfarin arm. There was no significant difference in thrombus resolution between the two groups (RR, 1.00; 95% CI [0.77-1.29; P = .98]). There was no significant difference in major bleeding (RR, 1.30; 95% CI [0.14-12.21; P = .82]) or stroke (RR, 0.42; 95% CI [0.09-2.06; P = .29]) between the two groups. CONCLUSION: The results of our meta-analysis show that NOACs are as efficacious and safe as warfarin in the treatment of left atrial appendage thrombus in patients with non-valvular atrial fibrillation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Administración Oral , Anticoagulantes/efectos adversos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Humanos , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Trombosis/prevención & control , Resultado del Tratamiento , Warfarina/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA