1.
J Vasc Interv Radiol ; 33(3): 255-261.e2, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34915165

RESUMEN

PURPOSE: To characterize an ovine endovascular radiofrequency (RF) ablation-based venous stenosis and thrombosis model for studying venous biomechanics and response to intervention. MATERIALS AND METHODS: Unilateral short-segment (n = 2) or long-segment (n = 6) iliac vein stenoses were created in 8 adult sheep using an endovenous RF ablation technique. Angiographic assessment was performed at baseline, immediately after venous stenosis creation, and after 2-week (n = 6) or 3-month (n = 2) survival. Stenosed iliac veins and the contralateral healthy controls were harvested for histological and biomechanical assessment. RESULTS: At follow-up, the short-segment RF ablation group showed stable stenosis without occlusion. The long-segment group showed complete venous occlusion/thrombosis with the formation of collateral veins. Stenosed veins showed significant wall thickening (0.28 vs 0.16 mm, P = .0175) and confluent collagen deposition compared with the healthy controls. Subacute nonadherent thrombi were apparent at 2 weeks, which were replaced by fibrous luminal obliteration with channels of recanalization at 3 months. Stenosed veins demonstrated increased longitudinal stiffness (448.5 ± 5.4 vs 314.6 ± 1.5 kPa, P < .0001) and decreased circumferential stiffness (140.8 ± 2.6 vs 246.0 ± 1.6 kPa, P < .0001) compared with the healthy controls. CONCLUSION: Endovenous RF ablation is a reliable technique for creating venous stenosis and thrombosis in a large animal model with histological and biomechanical attributes similar to those seen in humans. This platform can facilitate understanding of venous biomechanics and testing of venous-specific devices and interventions.


Asunto(s)
Ablación por Catéter , Enfermedades Vasculares , Insuficiencia Venosa , Trombosis de la Vena , Animales , Ablación por Catéter/métodos , Constricción Patológica/cirugía , Humanos , Vena Safena/cirugía , Ovinos , Resultado del Tratamiento , Enfermedades Vasculares/cirugía , Insuficiencia Venosa/cirugía , Trombosis de la Vena/cirugía
2.
J Vasc Interv Radiol ; 33(3): 262-267, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35221046

RESUMEN

This study characterized the impact of vein wall biomechanics on inflow diameter and luminal flow during venous angioplasty and stent placement, using postthrombotic and healthy biomechanical properties from an ovine venous stenosis and thrombosis model. Finite element analysis demonstrated more pronounced inflow channel narrowing in the postthrombotic vein compared with the healthy control vein during angioplasty and stent placement (relative inflow diameter reduction of 42% versus 13%, P < .0001). Computational fluid dynamics modeling showed increased relative areas of low wall shear rate in the postthrombotic vein compared with the normal vein (0.46 vs 0.24 for shear rate < 50 s-1; 0.13 vs 0.07 for shear rate < 15 s-1; P < .05), with flow stagnation and recirculation. Since inflow narrowing and low wall shear rate are associated with in-stent restenosis and reintervention, these computational results based on experimentally obtained biomechanical values highlight the significance of postthrombotic venous properties in optimizing venous intervention outcomes.


Asunto(s)
Vena Ilíaca , Stents , Angioplastia , Animales , Fenómenos Biomecánicos , Simulación por Computador , Humanos , Ovinos , Resultado del Tratamiento
3.
J Vasc Interv Radiol ; 32(7): 1031-1039.e2, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33607251

RESUMEN

PURPOSE: To elucidate in vitro and in vivo characteristics and embolic properties of imipenem-cilastatin (IPM-CS) compared with hydrogel microspheres. MATERIALS AND METHODS: Particle size distribution was microscopically evaluated with 3 samples of 50 mg IPM-CS suspensions in each of 6 conditions by a mixture of contrast volume: 500 or 1000 µL and vortex mixing time: 5, 10, or 30 s. Time-dependent changes up to 3 h post-mixing were also evaluated. Fifteen male Sprague-Dawley rats (460.2 ± 5.0 g) underwent unilateral renal artery embolization using IPM-CS (n = 11) or hydrogel microspheres (n = 4). Follow-up angiography 48 h after embolization and histological evaluation, including acute tubular necrosis (ATN) and inflammation, were scored using a 5-point scale (from 0 = normal to 4 = severe). RESULTS: Over 91% of IPM-CS particles were <40 µm under all in vitro conditions. With the increased contrast volume, the average particle size also increased (mean ± standard deviation: 11.6 ± 13.9 vs 16.7 ± 18.2 µm for 500 and 1000 µL iodinated contrast, P < .001); however, the impact of the mixing/elapsed time were limited. At 48 h after embolization, all cases in the IPM-CS groups (11/11) showed major to complete recanalization versus no recanalization with hydrogel microspheres (0/4) (P < .001). The following are the median ATN and inflammation grades in the cortex (ventral/dorsal) and medulla (ventral/dorsal) in both groups: IPM-CS, ATN in cortex (2/4) and medulla (1/1), inflammation in cortex (0/0) and medulla (0/0); hydrogel microspheres, ATN in cortex (4/4) and medulla (3/2), inflammation in cortex (1/1) and medulla (1/1). CONCLUSIONS: IPM-CS suspension generated particles that were predominantly smaller than 40 µm and with unique short-term embolic effects, leaving predominantly peripheral ischemic changes.


Asunto(s)
Infecciones Bacterianas , Artropatías , Animales , Cilastatina/uso terapéutico , Combinación Cilastatina e Imipenem/uso terapéutico , Quimioterapia Combinada , Imipenem/uso terapéutico , Masculino , Ratas , Ratas Sprague-Dawley
4.
J Vasc Interv Radiol ; 31(4): 678-681.e4, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31706884

RESUMEN

Transtail artery approach successfully enables selective arterial catheterization and angiography in the rat. This technique is effective and repeatable. In addition to its utility in imaging, it may also have a wide range of applications in transcatheter therapy and experimental cerebral stroke models.


Asunto(s)
Angiografía de Substracción Digital/métodos , Arterias/diagnóstico por imagen , Cateterismo Periférico/métodos , Radiografía Intervencional/métodos , Cola (estructura animal)/irrigación sanguínea , Animales , Estudios de Factibilidad , Masculino , Punciones , Ratas Sprague-Dawley
5.
J Vasc Interv Radiol ; 31(4): 682-685, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31690521

RESUMEN

The feasibility of a radiofrequency (RF) wire to replace the needle trocar for the creation of a transjugular intrahepatic portosystemic shunt (TIPS) was assessed in 3 swine by using fluoroscopy and intravascular ultrasonography (IVUS). RF wire passes were successful from hepatic to portal vein and from inferior vena cava to portal vein. Technical success was achieved using both IVUS guidance and carbon dioxide portography. The wire tracked a straight course under RF energy application without subjective deflection and, when centrally advanced, served as the working wire for completing the TIPS in 2 attempts with stent graft deployment. No procedural adverse events from the use of RF wire were observed.


Asunto(s)
Ablación por Catéter/instrumentación , Derivación Portosistémica Intrahepática Transyugular/instrumentación , Dispositivos de Acceso Vascular , Animales , Estudios de Factibilidad , Fluoroscopía , Modelos Animales , Agujas , Sus scrofa , Ultrasonografía Intervencional
6.
J Vasc Interv Radiol ; 31(8): 1348-1356, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32682711

RESUMEN

PURPOSE: To characterize the Poisson effect in response to angioplasty and stent placement in veins and identify potential implications for guiding future venous-specific device design. MATERIALS AND METHODS: In vivo angioplasty and stent placement were performed in 3 adult swine by using an established venous stenosis model. Iron particle endothelium labeling was performed for real-time fluoroscopic tracking of the vessel wall during intervention. A finite-element computational model of a vessel was created with ADINA software (version 9.5) with arterial and venous biomechanical properties obtained from the literature to compare the response to radial expansion. RESULTS: In vivo angioplasty and stent placement in a venous stenosis animal model with iron particle endothelium labeling demonstrated longitudinal foreshortening that correlated with distance from the center of the balloon (R2 = 0.87) as well as adjacent segment narrowing that correlated with the increase in diameter of the treated stenotic segment (R2 = 0.89). Finite-element computational analysis demonstrated increased Poisson effect in veins relative to arteries (linear regression coefficient slope comparison, arterial slope 0.033, R2 = 0.9789; venous slope 0.204, R2 = 0.9975; P < .0001) as a result of greater longitudinal Young modulus in veins compared with arteries. CONCLUSIONS: Clinically observed adjacent segment narrowing during venous angioplasty and stent placement is a result of the Poisson effect, with redistribution of radially applied force to the longitudinal direction. The Poisson effect is increased in veins relative to arteries as a result of unique venous biomechanical properties, which may be relevant to consider in the design of future venous interventional devices.


Asunto(s)
Angioplastia de Balón/instrumentación , Vena Ilíaca/fisiopatología , Modelos Cardiovasculares , Stents , Enfermedades Vasculares/terapia , Animales , Fenómenos Biomecánicos , Constricción Patológica , Modelos Animales de Enfermedad , Análisis de Elementos Finitos , Vena Ilíaca/diagnóstico por imagen , Sus scrofa , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/fisiopatología
7.
J Vasc Interv Radiol ; 30(9): 1480-1486.e2, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31202675

RESUMEN

PURPOSE: To assess selective accumulation of biodegradable nanoparticles within hepatic tumors after transarterial delivery for in vivo localization and combinatorial phototherapy. MATERIALS AND METHODS: A VX2 hepatic tumor model was used in New Zealand white rabbits. Transarterial delivery of silicon naphthalocyanine biodegradable nanoparticles was performed using a microcatheter via the proper hepatic artery. Tumors were exposed via laparotomy, and nanoparticles were observed by near-infrared (NIR) fluorescence imaging. For phototherapy, a handheld NIR laser (785 nm) at 0.6 W/cm2 was used to expose tumor or background liver, and tissue temperatures were assessed with a fiberoptic temperature probe. Intratumoral reactive oxygen species formation was assessed using a fluorophore (2',7'-dichlorodihydrofluorescein diacetate). RESULTS: Nanoparticles selectively accumulated within viable tumor by NIR fluorescence. Necrotic portions of tumor did not accumulate nanoparticles, consistent with a vascular distribution. NIR-dependent heat generation was observed with nanoparticle-containing tumors, but not in background liver. No heat was generated in the absence of NIR laser light. Reactive oxygen species were formed in nanoparticle-containing tumors exposed to NIR laser light, but not in background liver treated with NIR laser or in tumors in the absence of NIR light. CONCLUSIONS: Biodegradable nanoparticle delivery to liver tumors from a transarterial approach enabled selective in vivo tumor imaging and combinatorial phototherapy.


Asunto(s)
Medios de Contraste/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Nanopartículas , Imagen Óptica/métodos , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/administración & dosificación , Silanos/administración & dosificación , Nanomedicina Teranóstica/métodos , Animales , Línea Celular Tumoral , Femenino , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patología , Masculino , Proyectos Piloto , Valor Predictivo de las Pruebas , Conejos , Especies Reactivas de Oxígeno/metabolismo
8.
AJR Am J Roentgenol ; 210(4): W172, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29446679

RESUMEN

OBJECTIVE: The Viatorr stent-graft (W. L. Gore and Associates), specifically made for transjugular intrahepatic portosystemic shunt (TIPS) creation, has significantly improved TIPS patency compared with bare metal stents. Post-TIPS hepatic encephalopathy (HE), however, remains relatively common after TIPS creation. We describe a technique to secondarily restrict a Viatorr stent-graft to treat post-TIPS refractory HE and maintain use of the Viatorr device. CONCLUSION: We show a simple technique to modify the Viatorr stent-graft for TIPS reduction.


Asunto(s)
Prótesis Vascular , Derivación Portosistémica Intrahepática Transyugular , Stents , Humanos , Diseño de Prótesis
9.
Radiology ; 279(3): 910-6, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26690906

RESUMEN

Purpose To elucidate the effect of flow control (ie, balloon occlusion) and the composition of various mixtures of n-butyl-2 cyanoacrylate (NBCA) and iodized oil, with and without the addition of ethanol, for the treatment of arteriovenous malformations in an in vitro model. Materials and Methods A simulation circuit device that featured an artificial nidus was filled with heparinized swine blood obtained during exsanguination from another Institutional Animal Care and Use Committee-approved protocol and was constructed to generate pulsatile flow. Mixtures of NBCA and iodized oil (NL) at a 1:1 ratio (NL 1:1); NL and ethanol (NLE) at a 1:1:3 ratio (NLE 1:1:3) with or without flow control; and NL at 1:3, 1:5, and 1:10 ratios without flow control were injected six times each for a total of 42 trials. Embolization was classified as complete filling, proximal occlusion, pass through, or distal overpenetration after occlusion balloon deflation, and the trial results were compared. The results of the embolization test were evaluated by using the Fisher exact probability test to compare optimal and suboptimal embolization groups. Results NLE 1:1:3 with flow control completely filled the nidus in all six trials. NL 1:1 delivered with flow control achieved complete nidus filling in three of six injections, as did the NL 1:5 ratio trial without flow control. Complete embolization with NLE 1:1:3 with flow control was more feasible to achieve complete nidus filling than was NL 1:1 with flow control or NL 1:5 without flow control, although there was no statically significant difference (all, P = .09). None of the other mixtures produced complete embolization. Conclusion NLE 1:1:3 showed consistent and reproducible complete embolization with flow control and was stable after balloon deflation, making it an acceptable material for embolization in an in vitro arteriovenous malformation model. Further study should be performed before the NLE 1:1:3 mixture is used in routine clinical practice. (©) RSNA, 2015.


Asunto(s)
Malformaciones Arteriovenosas/terapia , Embolización Terapéutica , Enbucrilato/administración & dosificación , Etanol/administración & dosificación , Aceite Yodado/administración & dosificación , Animales , Malformaciones Arteriovenosas/sangre , Enbucrilato/química , Diseño de Equipo , Etanol/química , Aceite Yodado/química , Porcinos
10.
J Vasc Interv Radiol ; 27(1): 127-32, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26723923

RESUMEN

The present report describes a simple technique for tantalum coating of microspheres for visualization by fluoroscopy and computed tomography (CT). Spherical microspheres were soaked with Ta powder under different conditions and microscopically evaluated for Ta-coating quality by assessing bound and unbound Ta. For 100-300-µm Embosphere particles, soaking with 0.05 mL Ta powder for 30 minutes and centrifugation at 500 rpm produced optimal coating. Optimized microspheres were injected in swine renal arteries and assessed by fluoroscopy and micro-CT for the opacification of segmental, arcuate, and interlobular arteries. This practical method can be used for experimental studies with commonly available microspheres.


Asunto(s)
Microesferas , Arteria Renal/diagnóstico por imagen , Tantalio , Microtomografía por Rayos X , Animales , Fluoroscopía , Modelos Animales , Porcinos
12.
Radiol Oncol ; 47(1): 14-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23450088

RESUMEN

BACKGROUND: Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. MATERIALS AND METHODS: Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls. In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. RESULTS: The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. CONCLUSIONS: Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs.

13.
J Vasc Interv Radiol ; 23(8): 1077-83, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22739646

RESUMEN

PURPOSE: To explore if addition of fibrinogen to the most commonly used experimental blood clot (EBC) model would improve its mechanical properties and histologic structure. MATERIALS AND METHODS: Fresh blood from three swine was used to create four EBC types. The Gralla model of thrombin-induced barium-opaque EBC served as the control. In three other EBC types, 50 mg, 100 mg, and 200 mg of bovine fibrinogen were added. Evaluation of EBCs was done with three tests: manual elongation, injection through an 8-F catheter, and an opacity test. Thirty EBCs of each type were evaluated with each test. Histologic evaluation followed. RESULTS: The control EBCs had low tensile strength and broke at 165% elongation. However, they were elastic and returned to their original length after catheter injection. The EBCs with fibrinogen exhibited increased tensile strength with increasing fibrinogen doses and withstood elongation to 213% (P < .01). Their elasticity decreased with increased tensile strength, and they remained elongated after catheter injection (P < .01 for EBC with 100 mg and 200 mg fibrinogen). Histologic examination showed more thorough mixing of blood with barium and a significantly increased amount of fibrin after addition of fibrinogen. CONCLUSIONS: Addition of fibrinogen to a Gralla EBC model changes its mechanical properties proportionately to the fibrinogen dose. Fibrinogen increases EBC tensile strength but decreases its elasticity. Fibrinogen also significantly increases the binding of blood cells with fibrin on histologic slides.


Asunto(s)
Coagulación Sanguínea , Fibrinógeno/metabolismo , Accidente Cerebrovascular/cirugía , Trombectomía/instrumentación , Animales , Adhesión Celular , Elasticidad , Diseño de Equipo , Eritrocitos/metabolismo , Ensayo de Materiales , Accidente Cerebrovascular/sangre , Porcinos , Resistencia a la Tracción , Trombina/metabolismo
14.
Catheter Cardiovasc Interv ; 75(6): 861-7, 2010 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20432391

RESUMEN

PURPOSE: To evaluate the feasibility, effectiveness, and safety of a porcine small intestinal submucosa (SIS)-covered Biodisk (BD) for the closure of patent foramen ovale (PFO) in swine. METHODS: Twelve piglets (9-30 kg) with PFO ranging in size from 6 to 12 mm were used for the in vivo testing. The BD device consisted of two basic nitinol wire components covered with platinum coil, a flexible SIS-covered ring, and an anchor. The BD was advanced through an 8-Fr sheath from the femoral vein. Nine acute animals were used to test the BD for deployment, stability, immediate shunt closure, and device repositioning before or after its detachment. To assess retrievability, four devices were deployed and intentionally embolized into the RA (n = 2) and LA (n = 2). The effectiveness of the device was evaluated by angiocardiography. EKG was recorded before and after PFO closure for 3 hr. From the 12 animals, nine were acute and three were followed; one for 6 weeks, one for 12 weeks, and one for 16 weeks. RESULTS: Successful device implantation was achieved in all animals with no shunting of contrast media observed during follow-up in. One animal needed to have device repositioned for complete PFO occlusion because of suboptimal placement at the first attempt. The device was easily placed and retrieved before detachment in all nine animals in the acute study. None of the BDs spontaneously embolized during release or on follow-up. EKG did not demonstrate arrhythmias during or after treatment. Four intentionally embolized BDs were easily retrieved with an Amplatz goose neck snare. Macroscopic and histologic evaluation of the three long-term animals showed that devices were well incorporated in the atrial septum with complete shunt closure. The SIS showed progressive remodeling with the host cells. There was also progressive endothelization of the BD device. CONCLUSION: The BD device deployment is feasible, safe, and effective. Long-term studies are needed to evaluate its long-term effectiveness.


Asunto(s)
Foramen Oval Permeable/terapia , Dispositivo Oclusor Septal , Animales , Cateterismo Cardíaco , Diseño de Equipo , Estudios de Factibilidad , Porcinos
15.
Radiol Oncol ; 44(2): 86-91, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22933896

RESUMEN

BACKGROUND: Most of the presently used percutaneous arterial closure devices (PACD) for hemostasis after interventional vascular procedures are effective, but carry risk of complications by deposition of a foreign body. A new promising externally applied PACD - chitosan-based HemCon Bandage (HCB) was explored in sheep. The HCB hemostatic efficacy and complications occurring with its use were compared to those with the standard manual compression (SMC). MATERIAL AND METHODS: Both superficial femoral arteries (SFA) of 9 heparinized sheep were catheterized with an 8F sheath for 5 minutes. After the sheath withdrawal, hemostasis with the HCB was compared with hemostasis achieved with SMC in the contralateral SFA. Iliac angiograms performed by carotid artery approach determined the hemostasis time. RESULTS: The HCB use shortened time to hemostasis with a mean time of 6.9 ± 3.9 minutes versus 10.8 ± 2.8 minutes for the SMC (P-value 0.019). Seven SFAs in the HCB group and only 1 SFA in the SMC group exhibited hemostasis in 5 minutes. All nine SFAs using the HCB showed femoral artery patency and demonstrated less hematoma (2/9) than in the SMC group (8/9). No complications developed in the HCB group, one SFA occlusion was seen in the SMC group. CONCLUSIONS: The externally applied HCB in heparinized sheep was safe and effective. It significantly shortened time to hemostasis at the SFA access sites following 8F sheath removal. Proper application of the HCB was necessary to shorten hemostasis and prevent hematoma formation. The HCB should be tested in a clinically controlled study to evaluate its efficacy in humans.

16.
J Vasc Interv Radiol ; 19(12): 1772-6, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18948023

RESUMEN

An optional inferior vena cava (IVC) filter prototype was evaluated for safety and long-term retrievability as an initial feasibility study in an animal model. This filter has four centering struts that have the ability to disengage from the filtering cone portion, allowing the legs to slide out of endothelial growth. Retrieval of six filters in three animals was successful up to 27 weeks. There was no substantial filter tilt, migration, or IVC damage. In conclusion, this filter design may help overcome some of the shortcomings in currently approved optional IVC filters, including long-term retrieval difficulties, tilting, or migration.


Asunto(s)
Cateterismo/instrumentación , Remoción de Dispositivos , Filtros de Vena Cava , Vena Cava Inferior , Animales , Estudios de Factibilidad , Femenino , Ensayo de Materiales , Modelos Animales , Flebografía , Diseño de Prótesis , Ovinos , Factores de Tiempo , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/patología
17.
Cardiovasc Intervent Radiol ; 41(12): 1952-1957, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30088060

RESUMEN

PURPOSE: To evaluate the effect of air, CO2 and contrast medium-air on the dwell time (DT) stability of sodium tetradecyl sulfate (STS) foam. MATERIALS AND METHODS: Three types of foam sclerosants (air-foam, CO2-foam, contrast-air-foam) were injected eight times into an inclined straight plastic tube (internal diameters 4 mm and 10 mm) filled with a blood substitute. Injections were captured by CCD camera, and images were transferred for digital analysis and calculation of DT. RESULTS: Contrast-air-foam and air-foam in a 4-mm tube showed 5.6-/3.3-fold greater DT compared to CO2-foam, respectively (P = 0.001). Contrast-air-foam in a 10-mm tube showed 2.1-fold greater DT compared to CO2-foam (P = 0.0167). CONCLUSION: A mixture of air and iodinated contrast improves the stability of STS foam compared to mixtures using only air or CO2. Further, animal and clinical studies are needed to validate this in vitro result.


Asunto(s)
Aire , Dióxido de Carbono/química , Medios de Contraste/química , Yohexol/química , Soluciones Esclerosantes/química , Tetradecil Sulfato de Sodio/química , Humanos , Técnicas In Vitro , Sustancias Viscoelásticas
18.
J Clin Endocrinol Metab ; 90(6): 3706-14, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15769993

RESUMEN

Coronary hyperreactivity (CH), characterized by persistent severe vasoconstrictions in response to vasoconstrictor challenge, is oppositely influenced by progesterone (P) and medroxyprogesterone acetate (MPA) treatment in surgically menopausal primates. In this study we tested whether multiweek MPA or dihydrotestosterone (DHT) exposure induced CH in intact male rhesus monkeys. Coronary angiographic experiments with intracoronary serotonin and the thromboxane A(2) analog U46619 stimulated brief vasoconstriction (for 1-3 min) in large epicardial coronaries in untreated male monkeys. In contrast, MPA- and DHT-treated monkeys displayed long-duration constrictions (>5 min), with significantly greater reductions in the minimal diameters of epicardial coronaries. Immunocytochemistry demonstrated androgen receptors (AR) and P receptors in aorta and coronary arteries, and immunocytochemistry and Western blotting showed AR and P receptors in rhesus coronary vascular muscle cells. In vivo, MPA or DHT increased thromboxane prostanoid (TP) receptor expression in the aorta. In vitro, MPA or DHT increased, whereas P did not change, TP receptor expression in primary coronary vascular muscle cell. This MPA- or DHT-mediated increase in TP receptor expression was attenuated by the AR antagonist flutamide. MPA or DHT induction of CH in intact adult male primates, hypothesized to occur via androgenic up-regulation of vascular muscle TP receptor expression, could predispose to CH-mediated myocardial ischemia.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/fisiología , Dihidrotestosterona/farmacología , Acetato de Medroxiprogesterona/farmacología , Músculo Liso Vascular/fisiología , Animales , Circulación Coronaria/efectos de los fármacos , Vasos Coronarios/efectos de los fármacos , Macaca mulatta , Masculino , Músculo Liso Vascular/efectos de los fármacos
19.
Arterioscler Thromb Vasc Biol ; 24(5): 955-61, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15031127

RESUMEN

OBJECTIVE: To test if transdermal progesterone (P) confers coronary vascular protection in surgically menopausal preatherosclerotic rhesus monkeys. METHODS AND RESULTS: Ovariectomized rhesus monkeys fed an atherogenic diet (AD) for 19 months were treated with an investigational transdermal P cream (n=7) or identical placebo cream (n=5) for 4 weeks. Aorta and carotids showed fatty streaks and Oil Red O staining demonstrated lipid deposition. Serum P levels in P-treated rhesus monkeys (0.6 ng/mL) were significantly greater than placebo (0.2 ng/mL). Significant elevation of cholesterol, LDL cholesterol, and HDL cholesterol, was noted in all animals. Lp(a) was significantly attenuated in the AD-fed P-treated monkeys. Coronary angiographic experiments stimulating vasoconstriction by intracoronary injections of serotonin plus U46619 showed exaggerated prolonged actions amplified by AD, but significant protection against severe prolonged vasoconstriction in P-treated monkeys. Immunocytochemistry confirmed co-expression of P and thromboxane prostanoid (TP) receptors in coronaries and aorta. Western blotting demonstrated TP receptor attenuation in vascular muscle after P treatment. CONCLUSIONS: Coronary hyperreactivity, a putative component of coronary artery disease mediated via increased vascular muscle thromboxane prostanoid receptors, can be prevented by subphysiological levels of P, not only in nonatherosclerotic (previously shown) but also in preatherosclerotic primates.


Asunto(s)
Enfermedades de la Aorta/prevención & control , Enfermedades de las Arterias Carótidas/prevención & control , Enfermedad Coronaria/prevención & control , Vasoespasmo Coronario/prevención & control , Vasos Coronarios/fisiopatología , Terapia de Reemplazo de Hormonas , Menopausia Prematura , Progesterona/uso terapéutico , Administración Cutánea , Animales , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/metabolismo , Enfermedades de la Aorta/patología , Enfermedades de las Arterias Carótidas/etiología , Enfermedades de las Arterias Carótidas/metabolismo , Enfermedades de las Arterias Carótidas/patología , Enfermedad Coronaria/patología , Vasoespasmo Coronario/fisiopatología , Vasos Coronarios/efectos de los fármacos , Dieta Aterogénica , Evaluación Preclínica de Medicamentos , Femenino , Lípidos/análisis , Lípidos/sangre , Lipoproteína(a)/sangre , Macaca mulatta , Ovariectomía , Pregnanodiol/orina , Progesterona/administración & dosificación , Progesterona/sangre , Serotonina/farmacología , Vasoconstricción/efectos de los fármacos
20.
Tech Vasc Interv Radiol ; 6(3): 137-42, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-14614699

RESUMEN

The small-intestinal submucosa square-stent bicuspid venous valve has shown the most promising results of all of the artificial venous valves developed. In long-term experimental studies in sheep, 25 valves were placed into the jugular veins and 88% exhibited good function, whereas 12% had decreased function because of valve tilting. Only 4% had partial thrombosis in the tilted valve. Valves also were placed in 3 patients. The bicuspid venous valves remained patent without thrombosis or other complications. Proper sizing and proper placement of the valves was critical to their function. The valve construction needs to be improved to prevent occasional tilting during their deployment.


Asunto(s)
Bioprótesis , Prótesis Vascular , Insuficiencia Venosa/cirugía , Adulto , Animales , Humanos , Mucosa Intestinal , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Ovinos , Stents
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA