Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 35(7): 979-988.e1, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38537737

RESUMEN

PURPOSE: To assess the different adjunctive catheter techniques required to achieve complete occlusion of renal arteriovenous malformations (rAVMs) of different angioarchitectural types. MATERIALS AND METHODS: Overall, data on 18 patients with rAVM (Type 1, n = 7; Type 2, n = 2; Type 3, n = 9; mean age, 53.8 years) who underwent 25 procedures between 2011 and 2022 were reviewed. The clinical presentations, endovascular techniques, arteriovenous malformation (AVM) occlusion rate, adverse events (including the incidence of renal infarction), and clinical symptoms and outcomes (including recurrence/increase of AVM) were analyzed according to the Cho-Do angioarchitectural classification. Posttreatment renal infarction was classified as no infarction, small infarction (<12.5%), medium infarction (12.5%-25%), and large infarction (>25%) using contrast-enhanced computed tomography or magnetic resonance imaging. RESULTS: Hematuria and heart failure were presenting symptoms in 10 and 2 patients, respectively. The embolic materials used were as follows: Type 1 rAVM, coils alone or with n-butyl-2-cyanoacrylate (nBCA); Type 2 rAVM, nBCA alone or with coils; and Type 3 rAVMs, nBCA alone. Fourteen patients underwent adjunctive catheter techniques, including flow control with a balloon catheter and multiple microcatheter placement, alone or in combination. Immediate postprocedural angiography revealed complete occlusion in 15 patients (83%) and marked regression of rAVM in 3 (17%). Small asymptomatic renal infarctions were observed in 6 patients with Type 3 rAVMs without any decrease in renal function. No major adverse events were observed. All symptomatic patients experienced symptom resolution. Recurrence/increase of rAVM was not observed during the mean 32-month follow-up period (range, 2-120 months). CONCLUSIONS: Transarterial embolization using adjunctive catheter techniques according to angioarchitectural types can be an effective treatment for rAVMs.


Asunto(s)
Malformaciones Arteriovenosas , Embolización Terapéutica , Arteria Renal , Venas Renales , Humanos , Persona de Mediana Edad , Femenino , Masculino , Embolización Terapéutica/efectos adversos , Malformaciones Arteriovenosas/terapia , Malformaciones Arteriovenosas/diagnóstico por imagen , Resultado del Tratamiento , Adulto , Estudios Retrospectivos , Anciano , Arteria Renal/diagnóstico por imagen , Arteria Renal/anomalías , Venas Renales/diagnóstico por imagen , Venas Renales/anomalías , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas , Recurrencia , Factores de Tiempo , Adulto Joven , Factores de Riesgo , Enbucrilato/administración & dosificación , Infarto/diagnóstico por imagen , Infarto/etiología , Infarto/terapia , Angiografía por Resonancia Magnética
2.
Neuroradiology ; 66(3): 325-332, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38200284

RESUMEN

PURPOSE: Leptomeningeal enhancement (LME) suggests leptomeningeal dissemination (LMD) of tumor cells, which is a complication of end-stage glioblastoma, and is associated with a poor prognosis. However, magnetic resonance imaging (MRI) occasionally indicates the disappearance of peri-brainstem LME after surgical resection of glioblastoma. Since preoperative LMD may affect treatment indications, we aimed to analyze the clinical significance of preoperative LME of the brainstem in glioblastoma. METHODS: We retrospectively collected clinical and radiological data from consecutive patients with glioblastoma and preoperative LME of the brainstem, who were treated at our hospital between 2017 and 2020. RESULTS: Among 112 patients with glioblastoma, nine (8%) showed preoperative LME of the brainstem. In comparison with tumors without LME, tumor size was significantly associated with the preoperative LME of the brainstem (p = 0.016). In addition, there was a trend toward significance for a relationship between deep tumor location and preoperative LME of the brainstem (p = 0.058). Notably, among six patients who underwent surgical resection for glioblastoma with LME of the brainstem, four showed significant radiological disappearance of the LME on postoperative MRI. This suggests that the LME did not result from LMD in these cases. Moreover, these four patients lived longer than would be expected from the presence of LMD. However, this LME disappearance was not observed after biopsy or chemoradiotherapy. CONCLUSIONS: These findings suggest that preoperative LME does not necessarily indicate the presence of untreatable LMD; moreover, LME may disappear after surgical tumor resection. Thus, transient preoperative LME could be attributed to other mechanisms, including impaired venous flow due to intratumoral arteriovenous shunts, which can be resolved by reducing the tumor burden.


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagen , Glioblastoma/cirugía , Glioblastoma/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Quimioradioterapia , Tronco Encefálico/diagnóstico por imagen , Tronco Encefálico/cirugía , Tronco Encefálico/patología , Neoplasias Encefálicas/patología
3.
Neuroradiology ; 66(2): 217-226, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38148334

RESUMEN

PURPOSE: The aim of this study is to assess the effect of super-resolution deep learning-based reconstruction (SR-DLR), which uses k-space properties, on image quality of intracranial time-of-flight (TOF) magnetic resonance angiography (MRA) at 3 T. METHODS: This retrospective study involved 35 patients who underwent intracranial TOF-MRA using a 3-T MRI system with SR-DLR based on k-space properties in October and November 2022. We reconstructed MRA with SR-DLR (matrix = 1008 × 1008) and MRA without SR-DLR (matrix = 336 × 336). We measured the signal-to-noise ratio (SNR), contrast, and contrast-to-noise ratio (CNR) in the basilar artery (BA) and the anterior cerebral artery (ACA) and the sharpness of the posterior cerebral artery (PCA) using the slope of the signal intensity profile curve at the half-peak points. Two radiologists evaluated image noise, artifacts, contrast, sharpness, and overall image quality of the two image types using a 4-point scale. We compared quantitative and qualitative scores between images with and without SR-DLR using the Wilcoxon signed-rank test. RESULTS: The SNRs, contrasts, and CNRs were all significantly higher in images with SR-DLR than those without SR-DLR (p < 0.001). The slope was significantly greater in images with SR-DLR than those without SR-DLR (p < 0.001). The qualitative scores in MRAs with SR-DLR were all significantly higher than MRAs without SR-DLR (p < 0.001). CONCLUSION: SR-DLR with k-space properties can offer the benefits of increased spatial resolution without the associated drawbacks of longer scan times and reduced SNR and CNR in intracranial MRA.


Asunto(s)
Aprendizaje Profundo , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Imagen por Resonancia Magnética , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Neuroradiology ; 66(7): 1123-1130, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38480538

RESUMEN

PURPOSE: We aimed to evaluate the effect of deep learning-based reconstruction (DLR) on high-spatial-resolution three-dimensional T2-weighted fast asymmetric spin-echo (HR-3D T2-FASE) imaging in the preoperative evaluation of cerebellopontine angle (CPA) tumors. METHODS: This study included 13 consecutive patients who underwent preoperative HR-3D T2-FASE imaging using a 3 T MRI scanner. The reconstruction voxel size of HR-3D T2-FASE imaging was 0.23 × 0.23 × 0.5 mm. The contrast-to-noise ratios (CNRs) of the structures were compared between HR-3D T2-FASE images with and without DLR. The observers' preferences based on four categories on the tumor side on HR-3D T2-FASE images were evaluated. The facial nerve in relation to the tumor on HR-3D T2-FASE images was assessed with reference to intraoperative findings. RESULTS: The mean CNR between the tumor and trigeminal nerve and between the cerebrospinal fluid and trigeminal nerve was significantly higher for DLR images than non-DLR-based images (14.3 ± 8.9 vs. 12.0 ± 7.6, and 66.4 ± 12.0 vs. 53.9 ± 8.5, P < 0.001, respectively). The observer's preference for the depiction and delineation of the tumor, cranial nerves, vessels, and location relation on DLR HR-3D T2FASE images was superior to that on non-DLR HR-3D T2FASE images in 7 (54%), 6 (46%), 6 (46%), and 6 (46%) of 13 cases, respectively. The facial nerves around the tumor on HR-3D T2-FASE images were visualized accurately in five (38%) cases with DLR and in four (31%) without DLR. CONCLUSION: DLR HR-3D T2-FASE imaging is useful for the preoperative assessment of CPA tumors.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional , Imagen por Resonancia Magnética , Cuidados Preoperatorios , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Cuidados Preoperatorios/métodos , Anciano , Ángulo Pontocerebeloso/diagnóstico por imagen , Ángulo Pontocerebeloso/cirugía , Neoplasias Cerebelosas/diagnóstico por imagen , Neoplasias Cerebelosas/cirugía , Interpretación de Imagen Asistida por Computador/métodos , Estudios Retrospectivos , Neuroma Acústico/diagnóstico por imagen , Neuroma Acústico/cirugía
5.
J Comput Assist Tomogr ; 48(1): 85-91, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37531644

RESUMEN

PURPOSE: This study aimed to predict contrast effects in cardiac computed tomography (CT) from CT localizer radiographs using a deep learning (DL) model and to compare the prediction performance of the DL model with that of conventional models based on patients' physical size. METHODS: This retrospective study included 473 (256 men and 217 women) cardiac CT scans between May 2014 and August 2017. We developed and evaluated DL models that predict milligrams of iodine per enhancement of the aorta from CT localizer radiographs. To assess the model performance, we calculated and compared Pearson correlation coefficient ( r ) between the actual iodine dose that was necessary to obtain a contrast effect of 1 HU (iodine dose per contrast effect [IDCE]) and IDCE predicted by DL, body weight, lean body weight, and body surface area of patients. RESULTS: The model was tested on 52 cases for the male group (mean [SD] age, 63.7 ± 11.4) and 44 cases for the female group (mean [SD] age, 69.8 ± 11.6). Correlation coefficients between the actual and predicted IDCE were 0.607 for the male group and 0.412 for the female group, which were higher than the correlation coefficients between the actual IDCE and body weight (0.539 for male, 0.290 for female), lean body weight (0.563 for male, 0.352 for female), and body surface area (0.587 for male, 0.349 for female). CONCLUSIONS: The performance for predicting contrast effects by analyzing CT localizer radiographs with the DL model was at least comparable with conventional methods using the patient's body size, notwithstanding that no additional measurements other than CT localizer radiographs were required.


Asunto(s)
Aprendizaje Profundo , Yodo , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Retrospectivos , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Peso Corporal
6.
Artículo en Inglés | MEDLINE | ID: mdl-38346820

RESUMEN

OBJECTIVE: The aim of this study was to assess the utility of the combined use of 3D wheel sampling and deep learning-based reconstruction (DLR) for intracranial high-resolution (HR)-time-of-flight (TOF)-magnetic resonance angiography (MRA) at 3 T. METHODS: This prospective study enrolled 20 patients who underwent head MRI at 3 T, including TOF-MRA. We used 3D wheel sampling called "fast 3D" and DLR for HR-TOF-MRA (spatial resolution, 0.39 × 0.59 × 0.5 mm3) in addition to conventional MRA (spatial resolution, 0.39 × 0.89 × 1 mm3). We compared contrast and contrast-to-noise ratio between the blood vessels (basilar artery and anterior cerebral artery) and brain parenchyma, full width at half maximum in the P3 segment of the posterior cerebral artery among 3 protocols. Two board-certified radiologists evaluated noise, contrast, sharpness, artifact, and overall image quality of 3 protocols. RESULTS: The contrast and contrast-to-noise ratio of fast 3D-HR-MRA with DLR are comparable or higher than those of conventional MRA and fast 3D-HR-MRA without DLR. The full width at half maximum was significantly lower in fast 3D-MRA with and without DLR than in conventional MRA (P = 0.006, P < 0.001). In qualitative evaluation, fast 3D-MRA with DLR had significantly higher sharpness and overall image quality than conventional MRA and fast 3D-MRA without DLR (sharpness: P = 0.021, P = 0.001; overall image quality: P = 0.029, P < 0.001). CONCLUSIONS: The combination of 3D wheel sampling and DLR can improve visualization of arteries in intracranial TOF-MRA.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38718419

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the usefulness of the injection pressure-to-injection rate (IPIR) ratio for the early detection of contrast extravasation at the venipuncture site during contrast-enhanced computed tomography. METHODS: We retrospectively enrolled 57,528 patients who underwent contrast-enhanced computed tomography examinations in a single hospital. The power injector recorded the contrast injection pressure at 0.25-second intervals. We constructed logistic regression models using the IPIR ratio as the independent variable and extravasation occurrence as the dependent variable (IPIR ratio models) at 1, 2, 3, 4, 5, and 6 seconds after the start of contrast administration. Univariate logistic regression models in which injection pressure is used as an independent variable (injection pressure models) were also constructed as a reference baseline. The performance of the models was evaluated with the area under the receiver operating characteristic curves. RESULTS: Of the 57,528 cases, 46,022 were assigned to the training group and 11,506 were assigned to the test group, which included 112 extravasation cases (0.24%) in the training group and 28 (0.24%) in the test group. The area under the receiver operating characteristic curves for the IPIR ratio models and injection pressure models were 0.555 versus 0.563 at t = 1 (P = 0.270), 0.712 versus 0.678 at t = 2 (P = 0.305), 0.758 versus 0.693 at t = 3 (P = 0.032), 0.776 versus 0.688 at t = 4 (P = 0.005), 0.810 versus 0.699 at t = 5 (P = 0.002), and 0.811 versus 0.706 at t = 6 (P = 0.002). CONCLUSIONS: The IPIR ratio models perform better in detecting contrast extravasation at 3 to 6 seconds after the start of contrast administration than injection pressure models.

8.
Eur Radiol ; 33(11): 7923-7933, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37284863

RESUMEN

OBJECTIVES: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS: • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Estudios de Seguimiento , Embolización Terapéutica/métodos , Angiografía por Resonancia Magnética/métodos , Stents , Angiografía de Substracción Digital/métodos , Resultado del Tratamiento
9.
Eur Radiol ; 33(11): 7585-7594, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37178197

RESUMEN

OBJECTIVES: To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI). METHODS: This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test. RESULTS: The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008). CONCLUSIONS: The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI. CLINICAL RELEVANCE STATEMENT: Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T. KEY POINTS: • The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. • The DLR significantly improved the CNR and SNR of BH-MRCP. • The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.


Asunto(s)
Pancreatocolangiografía por Resonancia Magnética , Aprendizaje Profundo , Humanos , Pancreatocolangiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos
10.
Eur Radiol ; 33(5): 3253-3265, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36973431

RESUMEN

OBJECTIVES: To evaluate the image quality of deep learning-based reconstruction (DLR), model-based (MBIR), and hybrid iterative reconstruction (HIR) algorithms for lower-dose (LD) unenhanced head CT and compare it with those of standard-dose (STD) HIR images. METHODS: This retrospective study included 114 patients who underwent unenhanced head CT using the STD (n = 57) or LD (n = 57) protocol on a 320-row CT. STD images were reconstructed with HIR; LD images were reconstructed with HIR (LD-HIR), MBIR (LD-MBIR), and DLR (LD-DLR). The image noise, gray and white matter (GM-WM) contrast, and contrast-to-noise ratio (CNR) at the basal ganglia and posterior fossa levels were quantified. The noise magnitude, noise texture, GM-WM contrast, image sharpness, streak artifact, and subjective acceptability were independently scored by three radiologists (1 = worst, 5 = best). The lesion conspicuity of LD-HIR, LD-MBIR, and LD-DLR was ranked through side-by-side assessments (1 = worst, 3 = best). Reconstruction times of three algorithms were measured. RESULTS: The effective dose of LD was 25% lower than that of STD. Lower image noise, higher GM-WM contrast, and higher CNR were observed in LD-DLR and LD-MBIR than those in STD (all, p ≤ 0.035). Compared with STD, the noise texture, image sharpness, and subjective acceptability were inferior for LD-MBIR and superior for LD-DLR (all, p < 0.001). The lesion conspicuity of LD-DLR (2.9 ± 0.2) was higher than that of HIR (1.2 ± 0.3) and MBIR (1.8 ± 0.4) (all, p < 0.001). Reconstruction times of HIR, MBIR, and DLR were 11 ± 1, 319 ± 17, and 24 ± 1 s, respectively. CONCLUSION: DLR can enhance the image quality of head CT while preserving low radiation dose level and short reconstruction time. KEY POINTS: • For unenhanced head CT, DLR reduced the image noise and improved the GM-WM contrast and lesion delineation without sacrificing the natural noise texture and image sharpness relative to HIR. • The subjective and objective image quality of DLR was better than that of HIR even at 25% reduced dose without considerably increasing the image reconstruction times (24 s vs. 11 s). • Despite the strong noise reduction and improved GM-WM contrast performance, MBIR degraded the noise texture, sharpness, and subjective acceptance with prolonged reconstruction times relative to HIR, potentially hampering its feasibility.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Algoritmos , Aprendizaje Profundo , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Cabeza/diagnóstico por imagen
11.
Neuroradiology ; 65(11): 1619-1629, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37673835

RESUMEN

PURPOSE: The purpose of this study is to evaluate the influence of super-resolution deep learning-based reconstruction (SR-DLR), which utilizes k-space data, on the quality of images and the quantitation of the apparent diffusion coefficient (ADC) for diffusion-weighted images (DWI) in brain magnetic resonance imaging (MRI). METHODS: A retrospective analysis was performed on 34 patients who had undergone DWI using a 3 T MRI system with SR-DLR reconstruction based on k-space data in August 2022. DWI was reconstructed with SR-DLR (Matrix = 684 × 684) and without SR-DLR (Matrix = 228 × 228). Measurements were made of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) in white matter (WM) and grey matter (GM), and the full width at half maximum (FWHM) of the septum pellucidum. Two radiologists assessed image noise, contrast, artifacts, blur, and the overall quality of three image types using a four-point scale. Quantitative and qualitative scores between images with and without SR-DLR were compared using the Wilcoxon signed-rank test. RESULTS: Images with SR-DLR showed significantly higher SNRs and CNRs than those without SR-DLR (p < 0.001). No statistically significant variances were found in the apparent diffusion coefficients (ADCs) in WM and GM between images with and without SR-DLR (ADC in WM, p = 0.945; ADC in GM, p = 0.235). Moreover, the FWHM without SR-DLR was notably lower compared to that with SR-DLR (p < 0.001). CONCLUSION: SR-DLR has the potential to augment the quality of DWI in DL MRI scans without significantly impacting ADC quantitation.

12.
J Comput Assist Tomogr ; 47(2): 277-283, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36944152

RESUMEN

OBJECTIVE: For compressed sensing (CS) to become widely used in routine magnetic resonance imaging (MRI), it is essential to improve image quality. This study aimed to evaluate the usefulness of combining CS and deep learning-based reconstruction (DLR) for various sequences in shoulder MRI. METHODS: This retrospective study included 37 consecutive patients who underwent undersampled shoulder MRIs, including T1-weighted (T1WI), T2-weighted (T2WI), and fat-saturation T2-weighted (FS-T2WI) images. Images were reconstructed using the conventional wavelet-based denoising method (wavelet method) and a combination of wavelet and DLR-based denoising methods (hybrid-DLR method) for each sequence. The signal-to-noise ratio and contrast-to-noise ratio of the bone, muscle, and fat and the full width at half maximum of the shoulder joint were compared between the 2 image types. In addition, 2 board-certified radiologists scored the image noise, contrast, sharpness, artifacts, and overall image quality of the 2 image types on a 4-point scale. RESULTS: The signal-to-noise ratios and contrast-to-noise ratios of the bone, muscle, and fat in T1WI, T2WI, and FS-T2WI obtained from the hybrid-DLR method were significantly higher than those of the conventional wavelet method ( P < 0.001). However, there were no significant differences in the full width at half maximum of the shoulder joint in any of the sequences ( P > 0.05). Furthermore, in all sequences, the mean scores of the image noise, sharpness, artifacts, and overall image quality were significantly higher in the hybrid-DLR method than in the wavelet method ( P < 0.001), but there were no significant differences in contrast among the sequences ( P > 0.05). CONCLUSIONS: The DLR denoising method can improve the image quality of CS in T1-weighted images, T2-weighted images, and fat-saturation T2-weighted images of the shoulder compared with the wavelet denoising method alone.


Asunto(s)
Aprendizaje Profundo , Articulación del Hombro , Humanos , Hombro/diagnóstico por imagen , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Articulación del Hombro/diagnóstico por imagen
13.
J Comput Assist Tomogr ; 47(4): 659-665, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36877775

RESUMEN

PURPOSE: This study aimed to investigate the most useful clinical and magnetic resonance imaging (MRI) parameters for differentiating isocitrate dehydrogenase (IDH)-mutant and -wildtype glioblastomas in the 2016 World Health Organization Classification of Tumors of the Central Nervous System. METHODS: This multicenter study included 327 patients with IDH-mutant or IDH-wildtype glioblastoma in the 2016 World Health Organization classification who preoperatively underwent MRI. Isocitrate dehydrogenase mutation status was determined by immunohistochemistry, high-resolution melting analysis, and/or IDH1/2 sequencing. Three radiologists independently reviewed the tumor location, tumor contrast enhancement, noncontrast-enhancing tumor (nCET), and peritumoral edema. Two radiologists independently measured the maximum tumor size and mean and minimum apparent diffusion coefficients of the tumor. Univariate and multivariate logistic regression analyses with an odds ratio (OR) were performed. RESULTS: The tumors were IDH-wildtype glioblastoma in 306 cases and IDH-mutant glioblastoma in 21. Interobserver agreement for both qualitative and quantitative evaluations was moderate to excellent. The univariate analyses revealed a significant difference in age, seizure, tumor contrast enhancement, and nCET ( P < 0.05). The multivariate analysis revealed significant difference in age for all 3 readers (reader 1, odds ratio [OR] = 0.960, P = 0.012; reader 2, OR = 0.966, P = 0.048; reader 3, OR = 0.964, P = 0.026) and nCET for 2 readers (reader 1, OR = 3.082, P = 0.080; reader 2, OR = 4.500, P = 0.003; reader 3, OR = 3.078, P = 0.022). CONCLUSIONS: Age and nCET are the most useful parameters among the clinical and MRI parameters for differentiating IDH-mutant and IDH-wildtype glioblastomas.


Asunto(s)
Glioblastoma , Isocitrato Deshidrogenasa , Humanos , Glioblastoma/diagnóstico por imagen , Glioblastoma/enzimología , Glioblastoma/genética , Isocitrato Deshidrogenasa/genética , Biomarcadores de Tumor , Imagen por Resonancia Magnética , Estudios Retrospectivos , Estudios de Casos y Controles , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
14.
Eur Radiol ; 32(7): 4527-4536, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35169896

RESUMEN

OBJECTIVES: This study aimed to evaluate the efficacy of a combined wavelet and deep-learning reconstruction (DLR) method for under-sampled pituitary MRI. METHODS: This retrospective study included 28 consecutive patients who underwent under-sampled pituitary T2-weighted images (T2WI). Images were reconstructed using either the conventional wavelet denoising method (wavelet method) or the wavelet and DLR methods combined (hybrid DLR method) at five denoising levels. The signal-to-noise ratio (SNR) of the CSF, hypothalamic, and pituitary images and the contrast between structures were compared between the two image types. Noise quality, contrast, sharpness, artifacts, and overall image quality were evaluated by two board-certified radiologists. The quantitative and the qualitative analyses were performed with robust two-way repeated analyses of variance. RESULTS: Using the hybrid DLR method, the SNR of the CSF progressively increased as denoising levels increased. By contrast, with the wavelet method, the SNR of the CSF, hypothalamus, and pituitary did not increase at higher denoising levels. There was a significant main effect of denoising methods (p < 0.001) and denoising levels (p < 0.001), and an interaction between denoising methods and denoising levels (p < 0.001). For all five qualitative scores, there was a significant main effect of denoising methods (p < 0.001) and an interaction between denoising methods and denoising levels (p < 0.001). CONCLUSIONS: The hybrid DLR method can provide higher image quality for T2WI of the pituitary with compressed sensing (CS) than the wavelet method alone, especially at higher denoising levels. KEY POINTS: • The signal-to-noise ratios of cerebrospinal fluid progressively increased with the hybrid DLR method, with an increase in the denoising level for cerebrospinal fluid in pituitary T2WI with CS. • The signal-to-noise ratios of cerebrospinal fluid using the conventional wavelet method did not increase at higher denoising levels. • All qualitative scores of hybrid deep-learning reconstructions at all denoising levels were higher than those for the wavelet denoising method.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Relación Señal-Ruido
15.
J Comput Assist Tomogr ; 46(5): 693-700, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35830373

RESUMEN

OBJECTIVE: To assess the image quality of diffusion-weighted imaging (DWI) using multiband (MB) imaging with variable-rate selective excitation (VERSE) and compare it to conventional DWI. METHODS: We retrospectively evaluated hepatic DWI images of patients (n = 76) according to either the conventional method (SENSE, acceleration factor = 2) (n = 38) or fast scanning method (MB imaging with VERSE, acceleration factor = 2 × 2) (n = 38). We also conducted a volunteer study (n = 15) for those scanning methods. During quantitative analysis, the signal-to-noise ratio (SNR), apparent diffusion coefficient values, and contrast in the liver, spleen, and spinal cord were compared between the 2 groups. During qualitative analysis, all images were independently and blindly evaluated by 2 board-certified radiologists. The image contrast, noise, artifacts, and sharpness were assessed, and the performance of classification was measured using receiver operating characteristic curve analysis. RESULTS: In the retrospective study, the SNRs of the hepatic parenchyma and spinal cord between the 2 protocols were significantly different (liver, 8.9 [interquartile range {IQR}, 7.6-12.2] vs 13.0 [IQR, 10.0-16.7]; P < 0.001 and spinal cord, 6.0 [IQR, 4.7-9.4] vs 4.3 [IQR, 3.8-6.8]; P < 0.02). No significant differences between the 2 protocols in the other retrospective analyses were noted. In the receiver operating characteristic curve analysis, area under the curve was 0.49 (95% confidence intervals, 0.40-0.58). CONCLUSION: Multiband VERSE reduced scan time and SNR of hepatic DWI; however, subjective image quality parameters were not significantly impacted.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Hígado , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Humanos , Hígado/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
16.
Heart Vessels ; 37(7): 1115-1124, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35006370

RESUMEN

To evaluate the feasibility of spectral imaging with dual-layer spectral detector computed tomography (CT) for the diagnosis of acute coronary syndrome. We identified 30 consecutive patients who underwent cardiac CT using dual-layer spectral detector CT and were diagnosed with acute ischemic syndrome by an invasive coronary angiography. We reconstructed 120 kVp images and generated virtual monochromatic images (VMIs; 40-200 keV in 10 keV increments), iodine concentration maps, and effective atomic number (Z) maps. We calculated the contrast and contrast-to-noise ratio (CNR) between myocardial normal and hypo-perfusion and chose the VMIs with the best CNR for quantitative analysis. We compared the image noise, contrast, and CNR of 120 kVp images and the best VMIs, CT value, iodine concentration, and effective Z between myocardial normal and hypo-perfusion with the paired t test. As the X-ray energy decreased, venous attenuation, contrast, and CNR gradually increased. The 40 keV image yielded the best CNR. The contrast and CNR between myocardial normal and hypo-perfusion were significantly higher in 40 keV images than those in 120 kVp images. The iodine concentration and the effective Z were significantly higher in normal myocardium than those in hypo-perfused myocardium. Spectral imaging with dual-layer spectral detector CT is a feasible technique to detect the hypo-perfused area of acute ischemic syndrome.


Asunto(s)
Síndrome Coronario Agudo , Yodo , Síndrome Coronario Agudo/diagnóstico por imagen , Humanos , Perfusión , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
17.
Acta Radiol ; 63(4): 458-466, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33709794

RESUMEN

BACKGROUND: The low-tube-voltage scan generally needs a higher tube current than the conventional 120 kVp to maintain the image noise. In addition, the low-tube-voltage scan increases the photoelectric effect, which increases the radiation absorption in organs. PURPOSE: To compare the organ radiation dose caused by iodine contrast medium between low tube voltage with low contrast medium and that of conventional 120-kVp protocol with standard contrast medium. MATERIAL AND METHODS: After the propensity-matching analysis, 66 patients were enrolled including 33 patients with 120 kVp and 600 mgI/kg and 33 patients with 80 kVp and 300 mgI/kg (50% iodine reduction). The pre- and post-contrast phases were assessed in all patients. The Monte Carlo simulation tool was used to simulate the radiation dose. The computed tomography (CT) numbers for 10 organs and the organ doses were measured. The organ doses were normalized by the volume CT dose index, and the 120-kVp protocol was compared with the 80-kVp protocol. RESULTS: On contrast-enhanced CT, there were no significant differences in the mean CT numbers of the organs between 80-kVp and 120-kVp protocols except for the pancreas, kidneys, and small intestine. The normalized organ doses at 80 kVp were significantly lower than those of 120 kVp in all organs (e.g. liver, 1.6 vs. 1.9; pancreas, 1.5 vs. 1.8; spleen, 1.7 vs. 2.0) on contrast-enhanced CT. CONCLUSION: The low tube voltage with low-contrast-medium protocol significantly reduces organ doses at the same volume CT dose index setting compared with conventional 120-kVp protocol with standard contrast medium on contrast-enhanced CT.


Asunto(s)
Medios de Contraste , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/instrumentación , Imagen de Cuerpo Entero/métodos , Adulto , Femenino , Humanos , Yodo , Masculino , Persona de Mediana Edad
18.
J Neurooncol ; 152(3): 573-582, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33704629

RESUMEN

PURPOSE: Although tumor localization and 3,4-dihydroxy-6-18F-fluoro-L-phenylalanine (FDOPA) uptake may have an association, preferential tumor localization in relation to FDOPA uptake is yet to be investigated in lower-grade gliomas (LGGs). This study aimed to identify differences in the frequency of tumor localization between FDOPA hypometabolic and hypermetabolic LGGs using a probabilistic radiographic atlas. METHODS: Fifty-one patients with newly diagnosed LGG (WHO grade II, 29; III, 22; isocitrate dehydrogenase wild-type, 21; mutant 1p19q non-codeleted,16; mutant codeleted, 14) who underwent FDOPA positron emission tomography (PET) were retrospectively selected. Semiautomated tumor segmentation on FLAIR was performed. Patients with LGGs were separated into two groups (FDOPA hypometabolic and hypermetabolic LGGs) according to the normalized maximum standardized uptake value of FDOPA PET (a threshold of the uptake in the striatum) within the segmented regions. Spatial normalization procedures to build a 3D MRI-based atlas using each segmented region were validated by an analysis of differential involvement statistical mapping. RESULTS: Superimposition of regions of interest showed a high number of hypometabolic LGGs localized in the frontal lobe, while a high number of hypermetabolic LGGs was localized in the insula, putamen, and temporal lobe. The statistical mapping revealed that hypometabolic LGGs occurred more frequently in the superior frontal gyrus (close to the supplementary motor area), while hypermetabolic LGGs occurred more frequently in the insula. CONCLUSION: Radiographic atlases revealed preferential frontal lobe localization for FDOPA hypometabolic LGGs, which may be associated with relatively early detection.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagen , Dihidroxifenilalanina , Glioma/diagnóstico por imagen , Humanos , Isocitrato Deshidrogenasa , Clasificación del Tumor , Tomografía de Emisión de Positrones , Estudios Retrospectivos
19.
Eur Radiol ; 31(8): 5959-5966, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33475775

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the feasibility of non-contrast renal MRA using multi-shot gradient echo planar imaging (MSG-EPI) with a 3-T MRI system. METHODS: Seventeen healthy volunteers underwent non-contrast renal MRA using MSG-EPI and balanced steady-state free precession (b-SSFP) sequences on a 3-T MRI system. Two radiologists independently recorded the images' contrast, noise, sharpness, artifacts, and overall quality on 4-point scales. The signal-to-noise ratio (SNR) for the renal artery, the contrast ratio (CR) between the renal artery and erector spinae, and acquisition time were compared between the two sequences. RESULTS: The SNR and CR were significantly higher with MSG-EPI than with the b-SSFP sequence (17.80 ± 3.67 vs. 10.84 ± 2.86 and 0.77 ± 0.05 and 0.66 ± 0.09, respectively; p < 0.05), and the acquisition time was significantly lower (164.5 ± 34.0 vs. 261.5 ± 39.3 s, respectively; p < 0.05). There were significant differences in image contrast, noise, sharpness, artifacts, and overall image quality between the two sequences (p < 0.01). CONCLUSIONS: The MSG-EPI sequence is a promising technique that can shorten the scan time and improve the image quality of non-contrast renal MRA with a 3-T MRI system. KEY POINTS: • The multi-shot gradient echo planar imaging with an inversion pulse is a brand-new fast scan technique for an unenhanced renal MRA. • The image quality of multi-shot gradient echo planar imaging is better than that of b-SSFP for an unenhanced renal MRA.


Asunto(s)
Artefactos , Imagen Eco-Planar , Voluntarios Sanos , Humanos , Riñón , Relación Señal-Ruido
20.
Radiographics ; 41(7): 1936-1953, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34597178

RESUMEN

Optimizing the CT acquisition parameters to obtain diagnostic image quality at the lowest possible radiation dose is crucial in the radiosensitive pediatric population. The image quality of low-dose CT can be severely degraded by increased image noise with filtered back projection (FBP) reconstruction. Iterative reconstruction (IR) techniques partially resolve the trade-off relationship between noise and radiation dose but still suffer from degraded noise texture and low-contrast detectability at considerably low-dose settings. Furthermore, sophisticated model-based IR usually requires a long reconstruction time, which restricts its clinical usability. With recent advances in artificial intelligence technology, deep learning-based reconstruction (DLR) has been introduced to overcome the limitations of the FBP and IR approaches and is currently available clinically. DLR incorporates convolutional neural networks-which comprise multiple layers of mathematical equations-into the image reconstruction process to reduce image noise, improve spatial resolution, and preserve preferable noise texture in the CT images. For DLR development, numerous network parameters are iteratively optimized through an extensive learning process to discriminate true attenuation from noise by using low-dose training and high-dose teaching image data. After rigorous validations of network generalizability, the DLR engine can be used to generate high-quality images from low-dose projection data in a short reconstruction time in a clinical environment. Application of the DLR technique allows substantial dose reduction in pediatric CT performed for various clinical indications while preserving the diagnostic image quality. The authors present an overview of the basic concept, technical principles, and image characteristics of DLR and its clinical feasibility for low-dose pediatric CT. ©RSNA, 2021.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Inteligencia Artificial , Niño , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA