1.
Med Phys ; 47(12): 5986-6025, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32990328

RESUMEN

The use of radiochromic film (RCF) dosimetry in radiation therapy is extensive due to its high level of achievable accuracy for a wide range of dose values and its suitability under a variety of measurement conditions. However, since the publication of the 1998 AAPM Task Group 55, Report No. 63 on RCF dosimetry, the chemistry, composition, and readout systems for RCFs have evolved steadily. There are several challenges in using the new RCFs, readout systems and validation of the results depending on their applications. Accurate RCF dosimetry requires understanding of RCF selection, handling and calibration methods, calibration curves, dose conversion methods, correction methodologies as well as selection, operation and quality assurance (QA) programs of the readout systems. Acquiring this level of knowledge is not straight forward, even for some experienced users. This Task Group report addresses these issues and provides a basic understanding of available RCF models, dosimetric characteristics and properties, advantages and limitations, configurations, and overall elemental compositions of the RCFs that have changed over the past 20 yr. In addition, this report provides specific guidelines for data processing and analysis schemes and correction methodologies for clinical applications in radiation therapy.


Asunto(s)
Dosimetría por Película , Radiometría , Calibración
2.
Phys Med Biol ; 63(16): 165014, 2018 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-30124200

RESUMEN

The 0.35 T 60Co MRIdian system (ViewRay Inc., Mountain View) has been in clinical use in our institution since May 2016. For quality assurance (QA) of dose delivery and end-to-end testing for this machine, a reliable dosimeter is required. However, it is possible that a magnetic field may cause perturbations to dosimetry measurements. For static magnetic fields, there is conflicting information in the literature concerning EBT film behaviour, while for real-time MR imaging such information is not available at all. The purpose of this study was to investigate the suitability of EBT3 GafChromic film for MRIdian QA, both with and without real-time MR imaging. EBT3 film sheets were irradiated in water using the MRIdian and a conventional linear accelerator (Linac) for reference. Dose calibration measurements were first performed up to 8 Gy for both machines. The MRIdian measurements were performed with and without real-time MR imaging. Second, film sheets were irradiated at seven different angles with respect to the B0-field. Optical density and dose values were analysed for the three colour channels. In both the film dose-response and B0-field orientation measurements, the mean dose values were within the 1% uncertainty range of prescribed dose values for the red and green channels, for both machines. There were no dose deviations detected between the MRIdian and Linac film measurements, nor for different B0-field orientations. In addition, the film dose-response measurements during real-time imaging were within 1.5% of the reference Linac measurements. EBT3 GafChromic film can be used for absolute dosimetry during real-time MR imaging independent of its orientation in the B0-field. This makes it a suitable dosimeter for patient-specific QA measurements and end-to-end testing of 0.35 T MRI-radiotherapy devices.


Asunto(s)
Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias/radioterapia , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Radioterapia Guiada por Imagen/métodos , Radioisótopos de Cobalto/uso terapéutico , Humanos , Neoplasias/diagnóstico por imagen , Aceleradores de Partículas/instrumentación