Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Obstet Gynecol ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38908650

RESUMEN

OBJECTIVE: To investigate the association between actual and planned modes of delivery, neonatal mortality, and short-term outcomes among preterm pregnancies ≤32 weeks of gestation. DATA SOURCES: A systematic literature search was conducted in three main databases (PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception to November 16, 2022. The protocol was registered in advance in the International Prospective Register of Systematic Reviews (CRD42022377870). STUDY ELIGIBILITY CRITERIA: Eligible studies examined pregnancies ≤ 32nd gestational week. All infants received active care, and the outcomes were reported separately by different modes of delivery. Singleton and twin pregnancies at vertex and breech presentations were included. Studies that included pregnancies complicated with preeclampsia and abruptio placentae were excluded. Primary outcomes were neonatal mortality and intraventricular hemorrhage. STUDY APPRAISAL AND SYNTHESIS METHODS: Articles were selected by title, abstract, and full text, and disagreements were resolved by consensus. Random effects model-based odds ratios with corresponding 95% confidence intervals were calculated for dichotomous outcomes. ROBINS-I was used to assess the risk of bias. RESULTS: A total of nineteen observational studies were included involving a total of 16,042 preterm infants in this systematic review and meta-analysis. Actual cesarean delivery improves survival (odds ratio, 0.62; 95% confidence interval, 0.42 to 0.9) and decreases the incidence of intraventricular hemorrhage (odds ratio, 0.70; confidence interval, 0.57 to 0.85) compared to vaginal delivery. Planned cesarean delivery does not improve the survival of very and extremely preterm infants compared to vaginal delivery (odds ratio, 0.87; 95% confidence interval, 0.53 to 1.44). Subset analysis found significantly lower odds of death for singleton breech preterm deliveries born by both planned (odds ratio, 0.56; 95% confidence interval, 0.32 to 0.98) and actual (odds ratio, 0.34; 95% confidence interval, 0.13 to 0.88) cesarean delivery. CONCLUSION: Cesarean delivery should be the mode of delivery for preterm ≤32 weeks of gestation breech births due to the higher mortality in preterm infants born via vaginal delivery.

2.
Aging Ment Health ; 28(4): 646-651, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37830771

RESUMEN

OBJECTIVES: Older Canadian adults make up 85% of hospital stays which are associated with increased loneliness, stress, anxiety, and/or depression. There is a need for novel approaches to reduce loneliness and mental health outcomes in older adult hospital inpatients to prevent further strain on an already overwhelmed healthcare system. METHODS: This is a pilot randomized controlled trial (RCT) exploring the efficacy of a bedside multimodal interaction system, myHealthHub, on loneliness, quality of life (QOL), patient engagement, and other mental health outcomes compared to an active control group in older adult inpatients (n = 60) from baseline to 5-days. Qualitative analyses will be conducted through semi-structured interviews with older adults (n = 8-10) and hospital staff, nurses, and clinicians (n = 4-5) facilitating the service to evaluate patient engagement and experience with myHealthHub. RESULTS: Not applicable. CONCLUSION: This novel pilot clinical trial will obtain preliminary data on the efficacy of myHealthHub in reducing loneliness, QOL, patient engagement, and mental health outcomes in older adult inpatients. If successful, this could provide a potential means to improve patient experience in hospitals and reduce the burden and additional expense on the healthcare system.


Asunto(s)
Soledad , Salud Mental , Humanos , Anciano , Soledad/psicología , Pacientes Internos , Proyectos Piloto , Participación del Paciente , Canadá , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38015209

RESUMEN

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Asunto(s)
Técnicas de Sutura , Suturas , Humanos , Ensayo de Materiales , Resistencia a la Tracción , Rotura , Técnicas de Sutura/efectos adversos
4.
Clin Infect Dis ; 77(2): 312-320, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37125490

RESUMEN

BACKGROUND: Staphylococcus aureus is a global pathogen that is frequently responsible for healthcare-associated infections, including surgical site infections (SSIs). Current infection prevention and control approaches may be limited, with S. aureus antibiotic resistance remaining problematic. Thus, a vaccine to prevent or reduce S. aureus infection is critically needed. We evaluated the efficacy and safety of an investigational 4-antigen S. aureus vaccine (SA4Ag) in adults undergoing elective open posterior spinal fusion procedures with multilevel instrumentation. METHODS: In this multicenter, site-level, randomized, double-blind trial, patients aged 18-85 years received a single dose of SA4Ag or placebo 10-60 days before surgery. SA4Ag efficacy in preventing postoperative S. aureus bloodstream infection and/or deep incisional or organ/space SSIs was the primary end point. Safety evaluations included local reactions, systemic events, and adverse events (AEs). Immunogenicity and colonization were assessed. RESULTS: Study enrollment was halted when a prespecified interim efficacy analysis met predefined futility criteria. SA4Ag showed no efficacy (0.0%) in preventing postoperative S. aureus infection (14 cases in each group through postoperative day 90), despite inducing robust functional immune responses to each antigen compared with placebo. Colonization rates across groups were similar through postoperative day 180. Local reactions and systemic events were mostly mild or moderate in severity, with AEs reported at similar frequencies across groups. CONCLUSIONS: In patients undergoing elective spinal fusion surgical procedures, SA4Ag was safe and well tolerated but, despite eliciting substantial antibody responses that blocked key S. aureus virulence mechanisms, was not efficacious in preventing S. aureus infection. Clinical Trials Registration. NCT02388165.


Asunto(s)
Infecciones Estafilocócicas , Staphylococcus aureus , Adulto , Humanos , Pacientes Internos , Eficacia de las Vacunas , Infecciones Estafilocócicas/prevención & control , Infección de la Herida Quirúrgica/prevención & control , Vacunas Conjugadas , Método Doble Ciego
5.
BMC Musculoskelet Disord ; 24(1): 215, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36949409

RESUMEN

BACKGROUND/PURPOSE: Posterior pelvis ring injuries represent typical high-energy trauma injuries in young adults. Joint stabilization with two cannulated sacroiliac (SI) screws at the level of sacral vertebrae S1 and S2 is a well-established procedure. However, high failure- and implant removal (IR) rates have been reported. Especially, the washer recovery can pose the most difficult part of the IR surgery, which is often associated with complications. The aim of this biomechanical study was to evaluate the stability of S1-S2 fixation of the SI joint using three different screw designs. METHODS: Eighteen artificial hemi-pelvises were assigned to three groups (n = 6) for SI joint stabilization through S1 and S2 corridors using either two 7.5 mm cannulated compression headless screws (group CCH), two 7.3 mm partially threaded SI screws (group PT), or two 7.3 mm fully threaded SI screws (group FT). An SI joint dislocation injury type III APC according to the Young and Burgess classification was simulated before implantation. All specimens were biomechanically tested to failure in upright standing position under progressively increasing cyclic loading. Interfragmentary and bone-implant movements were captured via motion tracking and evaluated at four time points between 4000 and 7000 cycles. RESULTS: Combined interfragmentary angular displacement movements in coronal and transverse plane between ilium and sacrum, evaluated over the measured four time points, were significantly bigger in group FT versus both groups CCH and PT, p ≤ 0.047. In addition, angular displacement of the screw axis within the ilium under consideration of both these planes was significantly bigger in group FT versus group PT, p = 0.038. However, no significant differences were observed among the groups for screw tip cutout movements in the sacrum, p = 0.321. Cycles to failure were highest in group PT (9885 ± 1712), followed by group CCH (9820 ± 597), and group FT (7202 ± 1087), being significantly lower in group FT compared to both groups CCH and PT, p ≤ 0.027. CONCLUSION: From a biomechanical perspective, S1-S2 SI joint fixation using two cannulated compression headless screws or two partially threaded SI screws exhibited better interfragmentary stability compared to two fully threaded SI screws. The former can therefore be considered as a valid alternative to standard SI screw fixation in posterior pelvis ring injuries. In addition, partially threaded screw fixation was associated with less bone-implant movements versus fully threaded screw fixation. Further human cadaveric biomechanical studies with larger sample size should be initiated to understand better the potential of cannulated compression headless screw fixation for the therapy of the injured posterior pelvis ring in young trauma patients.


Asunto(s)
Fracturas Óseas , Luxaciones Articulares , Humanos , Fijación Interna de Fracturas , Tornillos Óseos , Fracturas Óseas/cirugía , Luxaciones Articulares/cirugía , Sacro/cirugía , Pelvis , Fenómenos Biomecánicos
6.
Medicina (Kaunas) ; 59(9)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37763723

RESUMEN

Background and Objectives: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation. Materials and Methods: Three-part AO/OTA 11-B1.1 unstable PHFs with metaphyseal defects were created in sixteen paired human cadaveric humeri (average donor age 76 years, range 66-92 years), pairwise assigned to two groups for locked plate fixation with identical implant configuration. In one of the groups, six-milliliter polymethylmethacrylate bone cement with medium viscosity (seven minutes after mixing) was placed manually through the lateral window in the defect of the humerus head after its anatomical reduction to the shaft and prior to the anatomical reduction of the greater tuberosity fragment. All specimens were tested biomechanically in a 25° adduction, applying progressively increasing cyclic loading at 2 Hz until failure. Interfragmentary movements were monitored by motion tracking and X-ray imaging. Results: Initial stiffness was not significantly different between the groups, p = 0.467. Varus deformation of the humerus head fragment, fracture displacement at the medial humerus head aspect, and proximal screw migration and cut-out were significantly smaller in the augmented group after 2000, 4000, 6000, 8000 and 10,000 cycles, p ≤ 0.019. Cycles to 5° varus deformation of the humerus head fragment-set as a clinically relevant failure criterion-and failure load were significantly higher in the augmented group, p = 0.018. Conclusions: From a biomechanical standpoint, augmentation with polymethylmethacrylate bone cement placed in the metaphyseal humerus head defect of plated unstable PHFs considerably enhances fixation stability and can reduce the risk of postoperative complications.

7.
Medicina (Kaunas) ; 59(2)2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36837571

RESUMEN

Background and Objectives: Proximal humerus fractures (PHFs) are common in the elderly, but the treatment results are often poor. A clear understanding of fracture morphology and distribution of cortical bone loss is important for improved surgical decision making, operative considerations, and new implant designs. The aim of this study was to develop a 3D segmentation fracture mapping technique to create a statistical description of the spatial pattern and cortical bone loss of complex PHFs. Materials and Methods: Fifty clinical computed tomography (CT) scans of complex PHFs and their contralateral intact shoulders were collected. In-house software was developed for semi-automated segmentation and fracture line detection and was combined with manual fracture reduction to the contralateral template in a commercial software. A statistical mean model of these cases was built and used to describe probability maps of the fracture lines and cortical fragments. Results: The fracture lines predominantly passed through the surgical neck and between the tuberosities and tendon insertions. The superior aspects of the tuberosities were constant fragments where comminution was less likely. Some fracture lines passed through the bicipital sulcus, but predominantly at its edges and curving around the tuberosities proximally and distally. Conclusions: A comprehensive and systematic approach was developed for processing clinical CT images of complex fractures into fracture morphology and fragment probability maps and applied on PHFs. This information creates an important basis for better understanding of fracture morphology that could be utilized in future studies for surgical training and implant design.


Asunto(s)
Enfermedades Óseas Metabólicas , Fracturas Conminutas , Fracturas del Hombro , Humanos , Anciano , Fijación Interna de Fracturas , Fracturas del Hombro/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Fracturas Conminutas/cirugía
8.
Healthc Manage Forum ; 36(2): 68-71, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36847595

RESUMEN

Peter Varga is the Chief Transformation Officer at HealthHub Solutions, Canada's leading provider of bedside patient engagement technology. Leslie Motz is the Executive Vice President of Patient Services and Chief Nursing Executive at Joseph Brant Hospital in Burlington, Ontario. In this article, Peter and Leslie examine Canada's ranking among OECD countries on the performance of its healthcare system and propose how optimizing processes around technology purchase and implementation can maximize the value that it can bring to improving health system performance.


Asunto(s)
Programas de Gobierno , Enfermeras Administradoras , Humanos , Ontario , Hospitales , Tecnología
9.
BMC Musculoskelet Disord ; 23(1): 774, 2022 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-35964023

RESUMEN

BACKGROUND: Successfully surgically treating degenerative disc diseases can be challenging to the spine surgeons, the long-term outcome relies on both the physical and mental status of the patient before and after treatment. Numerous studies underlined the role of inflammatory cytokines - like interleukin 1B and 6 - in the development of chronic diseases such as failed back surgery syndrome (FBSS) and major depressive disorder (MDD) which alter the outcome after spinal surgery. Our aim was to evaluate the associations of IL6 and IL1B gene polymorphisms with the long-term outcome of degenerative lumbar spine surgeries. METHODS: An international genetical database (GENODISC) was combined with our institute's clinical database to create a large pool with long term follow up data. Altogether 431 patient's data were analysed. Patient reported outcome measures and surgical outcome was investigated in association with IL1B and IL6 SNPs with the help of 'SNPassoc' R genome wide association package. RESULTS: Interleukin 1B variants analysis confirmed association with improvement of pain after surgery on individual SNP level and on haplotype level, moreover relationship with patient reported outcome and preoperative level of depression was found on individual SNP level. IL6 variants were associated with preoperative depression, somatization and with subsequent surgery. CONCLUSION: Understanding the complexity of spinal surgery patients' long-term well-being is crucial in effectively treating chronic debilitating somatic diseases and the associated mental illnesses. Further studies should investigate more comprehensively the linkage of chronic physical and mental illnesses focusing on their simultaneous treatment.


Asunto(s)
Trastorno Depresivo Mayor , Síndrome de Fracaso de la Cirugía Espinal Lumbar , Interleucina-1beta/genética , Interleucina-6/genética , Degeneración del Disco Intervertebral , Estudio de Asociación del Genoma Completo , Humanos , Degeneración del Disco Intervertebral/genética , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Polimorfismo de Nucleótido Simple/genética
10.
BMC Musculoskelet Disord ; 23(1): 35, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34986819

RESUMEN

Complex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.Thirty artificial radii with simulated AO/OTA 23-C2.1 and C3.1 DRFs, including dorsal defect and lunate facet comminution, were assigned to 3 groups: Group 1 with two equally-sized lunate facet fragments; Group 2 with small dorsal and large volar fragment; Group 3 with three equally-sized fragments. The specimens underwent volar and double locked plating and non-destructive ramped loading in 0° neutral position, 40° flexion and 40° extension.In each tested position, stiffness: (1) did not significantly differ among groups with same fixation method (p ≥ 0.15); (2) increased significantly after supplemental dorsal plating in Group 2 and Group 3 (p ≤ 0.02).Interfragmentary displacements between styloid process and lunate facet in neutral position were below 0.5 mm, being not significantly different among groups and plating techniques (p ≥ 0.63).Following volar plating, angular displacement of the lunate facet to radius shaft was significantly lower in Group 1 versus both Group 2 and Group 3 (p < 0.01). It decreased significantly after supplemental dorsal plating in Group 2 and Group 3 (p < 0.01), but not in Group 1 (p ≥ 0.13), and did not differ significantly among the three groups after double plating (p ≥ 0.74).Comminution of the lunate facet within its dorsal third significantly affected the biomechanical outcomes related to complex intraarticular DRFs treated with volar and double locked plates.Double plating demonstrates superior stability versus volar plating only for lunate facet comminution within its dorsal third. In contrast, volar plating could achieve stability comparable with double plating when the dorsal third of the lunate facet is not separated by the fracture pattern. Both fixation methods indicated achievable absolute stability between the articular fragments.


Asunto(s)
Fracturas Conminutas , Hueso Semilunar , Fracturas del Radio , Fenómenos Biomecánicos , Placas Óseas , Fijación Interna de Fracturas , Humanos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía
11.
J Shoulder Elbow Surg ; 31(1): 192-200, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34298147

RESUMEN

BACKGROUND: Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures. METHODS: FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males. RESULTS: The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men. CONCLUSION: The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.


Asunto(s)
Fracturas del Hombro , Fenómenos Biomecánicos , Placas Óseas , Simulación por Computador , Femenino , Fijación Interna de Fracturas , Humanos , Húmero , Masculino , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía
12.
Medicina (Kaunas) ; 58(8)2022 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-35893113

RESUMEN

Background and Objectives: Commonly being the first step in trauma routine imaging, up to 67% fractures are missed on plain radiographs of the thoracolumbar (TL) spine. The aim of this study was to develop a deep learning model that detects traumatic fractures on sagittal radiographs of the TL spine. Identifying vertebral fractures in simple radiographic projections would have a significant clinical and financial impact, especially for low- and middle-income countries where computed tomography (CT) and magnetic resonance imaging (MRI) are not readily available and could help select patients that need second level imaging, thus improving the cost-effectiveness. Materials and Methods: Imaging studies (radiographs, CT, and/or MRI) of 151 patients were used. An expert group of three spinal surgeons reviewed all available images to confirm presence and type of fractures. In total, 630 single vertebra images were extracted from the sagittal radiographs of the 151 patients-302 exhibiting a vertebral body fracture, and 328 exhibiting no fracture. Following augmentation, these single vertebra images were used to train, validate, and comparatively test two deep learning convolutional neural network models, namely ResNet18 and VGG16. A heatmap analysis was then conducted to better understand the predictions of each model. Results: ResNet18 demonstrated a better performance, achieving higher sensitivity (91%), specificity (89%), and accuracy (88%) compared to VGG16 (90%, 83%, 86%). In 81% of the cases, the "warm zone" in the heatmaps correlated with the findings, suggestive of fracture within the vertebral body seen in the imaging studies. Vertebras T12 to L2 were the most frequently involved, accounting for 48% of the fractures. A4, A3, and A1 were the most frequent fracture types according to the AO Spine Classification. Conclusions: ResNet18 could accurately identify the traumatic vertebral fractures on the TL sagittal radiographs. In most cases, the model based its prediction on the same areas that human expert classifiers used to determine the presence of a fracture.


Asunto(s)
Fracturas de la Columna Vertebral , Vértebras Torácicas , Inteligencia Artificial , Humanos , Vértebras Lumbares/lesiones , Radiografía , Estudios Retrospectivos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/lesiones
13.
Medicina (Kaunas) ; 58(10)2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36295586

RESUMEN

Background and Objectives: The treatment of proximal humerus fractures in elderly patients is challenging, with reported high complication rates mostly related to implant failure involving screw cut-out and penetration. Metaphyseal defects are common in osteoporotic bone and weaken the osteosynthesis construct. A novel technique for augmentation with polymethylmethacrylate (PMMA) bone cement was developed for the treatment of patients in advanced age with complex proximal humerus fractures and metaphyseal voids, whereby the cement was allowed to partially cure for 5-7 min after mixing to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window with a volume of 4-6 mL per patient. The aim of this retrospective clinical study was to assess this technique versus autologous bone graft augmentation and no augmentation. Materials and Methods: The outcomes of 120 patients with plated Neer three- and four-part fractures, assigned to groups of 63 cases with no augmentation, 28 with bone graft augmentation and 29 with cement augmentation, were assessed in this study. DASH, CS, pain scores and range of motion were analyzed at 3, 6 and 12 months. Statistical analysis was performed with factors for treatment and age groups, Neer fracture types and follow-up periods, and with the consideration of age as a covariate. Results: DASH and CS improved following cement augmentation at three and six months compared to bone grafting, being significant when correcting for age as a covariate (p ≤ 0.007). While the age group had a significant effect on both these scores with worsened values at a higher age for non-augmented and grafted patients (p ≤ 0.044), this was not the case for cement augmented patients (p ≥ 0.128). Cement augmentation demonstrated good clinical results at 12 months with a mean DASH of 10.21 and mean CS percentage of 84.83% versus the contralateral side, not being significantly different among the techniques (p ≥ 0.372), despite the cement augmented group representing the older population with more four-part fractures. There were no concerning adverse events specifically related to the novel technique. Conclusions: This study has detailed a novel technique for the treatment of metaphyseal defects with PMMA cement augmentation in elderly patients with complex proximal humerus fractures and follow-up to one year, whereby the cement was allowed to partially cure to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window. The results demonstrate clinically equivalent short-term results to 6 months compared to augmentation with bone graft or no augmentation-despite the patient group being older and with a higher rate of more severe fracture patterns. The technique appears to be safe with no specifically related adverse events and can be added in the surgeon's armamentarium for the treatment of these difficult to manage fractures.


Asunto(s)
Cementos para Huesos , Fracturas del Hombro , Humanos , Anciano , Cementos para Huesos/uso terapéutico , Polimetil Metacrilato/uso terapéutico , Estudios Retrospectivos , Fracturas del Hombro/cirugía , Fracturas del Hombro/tratamiento farmacológico , Placas Óseas , Fijación Interna de Fracturas , Húmero/cirugía
14.
Calcif Tissue Int ; 108(3): 314-323, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33452889

RESUMEN

Obtaining high-resolution scans of bones and joints for clinical applications is challenging. HR-pQCT is considered the best technology to acquire high-resolution images of the peripheral skeleton in vivo, but a breakthrough for widespread clinical applications is still lacking. Recently, we showed on trapezia that CBCT is a promising alternative providing a larger FOV at a shorter scanning time. The goals of this study were to evaluate the accuracy of CBCT in quantifying trabecular bone microstructural and predicted mechanical parameters of the distal radius, the most often investigated skeletal site with HR-pQCT, and to compare it with HR-pQCT. Nineteen radii were scanned with four scanners: (1) HR-pQCT (XtremeCT, Scanco Medical AG, @ (voxel size) 82 µm), (2) HR-pQCT (XtremeCT-II, Scanco, @60.7 µm), (3) CBCT (NewTom 5G, Cefla, @75 µm) reconstructed and segmented using in-house developed software and (4) microCT (VivaCT40, Scanco, @19 µm-gold standard). The following parameters were evaluated: predicted stiffness, strength, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The overall accuracy of CBCT with in-house optimized algorithms in quantifying bone microstructural parameters was comparable (R2 = 0.79) to XtremeCT (R2 = 0.76) and slightly worse than XtremeCT-II (R2 = 0.86) which were both processed with the standard manufacturer's technique. CBCT had higher accuracy for BV/TV and Tb.Th but lower for Tb.Sp and Tb.N compared to XtremeCT. Regarding the mechanical parameters, all scanners had high accuracy (R2 [Formula: see text] 0.96). While HR-pQCT is optimized for research, the fast scanning time and good accuracy renders CBCT a promising technique for high-resolution clinical scanning.


Asunto(s)
Densidad Ósea , Huesos/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Radio (Anatomía) , Algoritmos , Humanos , Radio (Anatomía)/diagnóstico por imagen , Microtomografía por Rayos X
15.
Curr Osteoporos Rep ; 19(4): 403-416, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34185266

RESUMEN

PURPOSE OF REVIEW: Fracture fixation aims to provide stability and promote healing, but remains challenging in unstable and osteoporotic fractures with increased risk of construct failure and nonunion. The first part of this article reviews the clinical motivation behind finite element analysis of fracture fixation, its strengths and weaknesses, how models are developed and validated, and how outputs are typically interpreted. The second part reviews recent modeling studies of the femur and proximal humerus, areas with particular relevance to fragility fractures. RECENT FINDINGS: There is some consensus in the literature around how certain modeling aspects are pragmatically formulated, including bone and implant geometries, meshing, material properties, interactions, and loads and boundary conditions. Studies most often focus on predicted implant stress, bone strain surrounding screws, or interfragmentary displacements. However, most models are not rigorously validated. With refined modeling methods, improved validation efforts, and large-scale systematic analyses, finite element analysis is poised to advance the understanding of fracture fixation failure, enable optimization of implant designs, and improve surgical guidance.


Asunto(s)
Fracturas del Fémur/terapia , Análisis de Elementos Finitos , Fijación de Fractura/métodos , Fracturas del Húmero/terapia , Fracturas Osteoporóticas/terapia , Femenino , Humanos
16.
Med Sci Monit ; 27: e932731, 2021 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-34608109

RESUMEN

BACKGROUND Wilms' tumor is a common renal malignancy of early childhood with a generally favorable prognosis depending upon histological subtype. It is becoming increasingly clear that differences in miRNA (microRNA) expression signature represent important clues helping us predict a tumor's response to chemotherapy. In our study, we aimed to reveal miRNAs deregulated in regressive Wilms' tumors from FFPE (formalin-fixed, paraffin-embedded) samples, also showing whether such samples are reliable miRNA sources in Wilms' tumor. MATERIAL AND METHODS Samples from 8 Hungarian patients (3 males, 5 females, aged 1 to 7 years) were analyzed by qRT-PCR (quantitative real-time PCR). A PCR array was used in a pilot experiment, and selected miRNAs (miR-128-3p, miR-184, miR-194-5p, miR-203a) were studied in the rest of the samples using individual primers. RESULTS miR-194-5p was underexpressed in all tumor samples. miR-184 and miR-203a were underexpressed in 7 cases, the exception being a case with a high ratio of necrotic blastemal tissue. Results obtained with miR-128-3p are difficult to interpret due to varying directions of expression changes. CONCLUSIONS We conclude that a downregulation of miR-184, miR-194-5p, and miR-203a expression is observed in both regressive and blastemal tumors, but larger-scale studies are needed to confirm whether the degree of their underexpression correlates with the number of blastemal elements in a sample. In most of our FFPE samples aged up to 9 years, RNA extraction provided miRNA with quantity and quality sufficient for qRT-PCR-based analysis, emphasizing the relevance of pathological archives as miRNA sources in future studies.


Asunto(s)
Perfilación de la Expresión Génica/métodos , Neoplasias Renales/genética , MicroARNs/genética , Adhesión en Parafina/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Tumor de Wilms/genética , Niño , Preescolar , Femenino , Regulación Neoplásica de la Expresión Génica , Humanos , Hungría , Lactante , Masculino
17.
BMC Med Educ ; 21(1): 156, 2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33711985

RESUMEN

BACKGROUND: Near-peer teaching (NPT) is a special way of teaching where the tutor is one or more academic years ahead of the person being tutored. The literature agrees on the benefits of the method, but there are only a few publications examining its effectiveness using objective methods. The aim of our study was to examine the effectiveness of NPT in the training of basic surgical skills. METHODS: We included 60 volunteer students who participated in a 20 × 45 min long surgical skills course. Based on the results of a pre-course test, we randomly divided the students into six equal groups. All groups completed the same curriculum, with three groups being assisted by a NPT tutor. After the course, they completed the same test as at the beginning. The exams were recorded on anonymized videos and were blindly evaluated. The students' satisfaction was monitored using a self-administered online anonymous questionnaire. Statistical analysis was performed using the Mann-Whitney and Wilcoxon tests. RESULTS: Overall, student performance improved with completion of the course (from 119.86 to 153.55 points, p <  0.01). In groups where a NPT tutor assisted, students achieved a significantly better score (37.20 vs. 30.18 points improvement, p = 0.036). The difference was prominent in surgical knotting tasks (14.73 vs. 9.30 points improvement, p <  0.01). In cases of suturing (15.90 vs. 15.46 points) and laparoscopy (7.00 vs. 4.98 points), the presence of the NPT tutor did not significantly affect development. Based on student feedback, although students positively assessed the presence of NPT, it did not significantly improve students' overall satisfaction since it was already 4,82 on a scale of 5 in the control group. CONCLUSIONS: Overall, involving a NPT tutor had a positive impact on student development. An outstanding difference was observed in connection with knotting techniques.


Asunto(s)
Educación de Pregrado en Medicina , Estudiantes de Medicina , Competencia Clínica , Curriculum , Evaluación Educacional , Humanos , Grupo Paritario , Enseñanza
18.
Sensors (Basel) ; 21(19)2021 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-34640951

RESUMEN

Numerous methods and devices are available for implant fixation in anterior cruciate ligament (ACL) reconstruction. Biomechanical data indicate high variability in fixation stability across different devices. This study aims to provide a better insight into measuring the structural characteristics and mechanical behavior of ACL implant fixations. Fourteen human tibial specimens with reconstructed ACLs were subjected to progressively increasing dynamic loading until failure. The motions of the tibia, the proximal and distal graft ends, as well as the testing frame and actuator, were continuously recorded via a motion tracking system. Significantly higher displacements of the machine actuator (1.0 mm at graft slippage onset, and 12.2 mm at ultimate load) were measured compared to the displacements of the proximal (0.8 and 4.3 mm, respectively) and distal graft (0.1 and 3.4 mm, respectively) ends. The displacements measured at different sites showed significant correlations. The provided data suggest significant and systematic inaccuracies in the stiffness and slippage of the fixation when using machine displacement, as commonly reported in the literature. The assessment of the distal graft displacement excludes the artifactual graft elongation, and most accurately reflects the graft slippage onset indicating clinical failure. Considering the high displacement at the ultimate load, the ultimate load could be used as a standardized variable to compare different fixation methods. However, the ultimate load alone is not sufficient to qualitatively describe fixation stability.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Tornillos Óseos , Humanos , Tibia/cirugía
19.
Paediatr Perinat Epidemiol ; 34(5): 565-571, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31650575

RESUMEN

BACKGROUND: There are limited data available on the survival and early complications of preterm infants with less than 500 g birthweight. To estimate the outcomes for these infants, it is important for caregivers to be aware of perinatal factors that may affect survival. OBJECTIVES: We assessed the mortality and certain early complications of preterm infants born with less than 500 g in Hungary between 2006 and 2015. METHODS: We reviewed data of 486 infants from the database of the Hungarian Central Statistical Office and in parallel of 407 infants from the "NICU database." The study period was divided into two epochs: 2006-2010 and 2011-2015. RESULTS: The survival was 27.1% in the first epoch and 39.1% in the second epoch, and the incidence of early complications was slightly higher in the second epoch. In the surviving group (first and second epoch combined), gestational age (25.1 vs 23.7 weeks), birthweight (458 vs 447 g) antenatal steroid treatment (66.3% vs 52.3%), surfactant therapy (95.1% vs 84.3%), median Apgar scores (6 vs 3 and 8 vs 5 at 1 and 5 minutes, respectively) and proportion of caesarean delivery (89.3% versus 68.5%) were higher than in the non-surviving group (first and second epoch combined). The proportion of multiple births was lower in the surviving group (15.7% vs 33.4%). CONCLUSIONS: Survival of infants with less than 500 g improved between 2006-2010 and 2011-2015 in Hungary. The slightly higher occurrence of early complications might be associated with improving survival.


Asunto(s)
Cesárea/estadística & datos numéricos , Glucocorticoides/uso terapéutico , Surfactantes Pulmonares/uso terapéutico , Tasa de Supervivencia/tendencias , Adulto , Puntaje de Apgar , Displasia Broncopulmonar/epidemiología , Hemorragia Cerebral Intraventricular/epidemiología , Enterocolitis Necrotizante/epidemiología , Femenino , Humanos , Hungría/epidemiología , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recien Nacido Extremadamente Prematuro , Recién Nacido , Leucomalacia Periventricular/epidemiología , Mortalidad/tendencias , Progenie de Nacimiento Múltiple/estadística & datos numéricos , Embarazo , Atención Prenatal , Retinopatía de la Prematuridad/epidemiología
20.
Med Sci Monit ; 26: e926947, 2020 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-33298824

RESUMEN

The limit of viability for premature newborns has changed in recent decades, but whether to initiate or withhold active care for periviable infants remains a subject of debate because the chances of survival and the extent of severe neurological impairment can be unclear. In our review, we analyzed large population-based studies of periviable infants from the past 2 decades. We compared survival rates and the incidence of early complications among survivors, including bronchopulmonary dysplasia, intraventricular hemorrhage, periventricular leukomalacia, retinopathy of prematurity, and necrotizing enterocolitis. Moreover, we assessed the perinatal factors that may affect the survival of preterm infants. We analyzed 15 studies reporting data on preterm infants born between 22 and 28 gestational weeks. None of these studies reported survival of an infant born before 22 gestational weeks. Survival rates of infants born at 24 weeks' gestation were above 50% in most studies. The incidence of each complication was also higher among infants born at ≤24 weeks. Of the analyzed perinatal factors, antenatal corticosteroid therapy, birth weight, female sex, cesarean delivery, singleton pregnancy, and birth in a tertiary-level Neonatal Intensive Care Unit were found to be associated with improved survival in some studies. The different methodologies of the studies limited comparison of the results. Further investigations are needed to gain up-to-date information on the limit of viability, and standardized methods in future studies would enable more accurate comparisons of findings.


Asunto(s)
Recien Nacido Extremadamente Prematuro/fisiología , Edad Gestacional , Humanos , Recién Nacido , Enfermedades del Prematuro/mortalidad , Morbilidad , Pronóstico , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA