Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Med Phys ; 37(9): 4560-71, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20964173

RESUMEN

PURPOSE: To investigate the effect of the bronchial tree on the accuracy of biomechanical-based deformable image registration of human lungs. METHODS: Three dimensional finite element models have been developed using four dimensional computed tomography image data of ten lung cancer patients. Each model is built of a body, left and right lungs, tumor, and bronchial trees. Triangular shell elements are used for the bronchial trees while tetrahedral elements are used for other components. Hyperelastic material properties based on experimental investigation on human lungs are used for the lung parenchyma. Different material properties are assigned for the bronchial tree using five values for the modulus of elasticity of 0.01, 0.12, 0.5, 10, and 18 MPa. Lungs are modeled to slide inside chest cavities by applying frictionless contact surfaces between each lung and corresponding chest cavity. The accuracy of the models is examined using an average of 40 bronchial bifurcation points identified on inhale and exhale images. Relative accuracy is evaluated by comparing the displacement of all nodes within the lungs as well as the dosimetric difference at the exhale position predicted by the model. RESULTS: There is no significant effect of bronchial tree on the model accuracy based on the bifurcation points analysis. However, on the local level, using an average of 38 000 nodes, there is a maximum difference of 8.5 mm in the deformation of the bronchial trees, as the modulus of elasticity of the bronchial trees increases from 0.01 to 18 MPa; however, more than 96% of nodes are within a 2.5 mm difference in each direction. The average dose difference at the predicted exhale position is less than 35 cGy between the models. CONCLUSIONS: The bronchial tree has little effect on the global deformation and the accuracy of deformable image registration of lungs. Hence, the homogenous model is a reasonable assumption. Since there are some local deformation differences between nodes as the material properties of the bronchial tree change that may affect the accuracy of dosimetric results, heterogeneity may be required for a smaller scale modeling of lungs.


Asunto(s)
Bronquios/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Anatómicos , Fenómenos Biomecánicos , Bronquios/fisiología , Bronquios/efectos de la radiación , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/fisiopatología , Módulo de Elasticidad , Espiración , Análisis de Elementos Finitos , Humanos , Inhalación , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/fisiopatología , Dosis de Radiación , Radiometría , Tomografía Computarizada por Rayos X
2.
Phys Med Biol ; 56(15): 4701-13, 2011 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-21734336

RESUMEN

Both accuracy and efficiency are critical for the implementation of biomechanical model-based deformable registration in clinical practice. The focus of this investigation is to evaluate the potential of improving the efficiency of the deformable image registration of the human lungs without loss of accuracy. Three-dimensional finite element models have been developed using image data of 14 lung cancer patients. Each model consists of two lungs, tumor and external body. Sliding of the lungs inside the chest cavity is modeled using a frictionless surface-based contact model. The effect of the type of element, finite deformation and elasticity on the accuracy and computing time is investigated. Linear and quadrilateral tetrahedral elements are used with linear and nonlinear geometric analysis. Two types of material properties are applied namely: elastic and hyperelastic. The accuracy of each of the four models is examined using a number of anatomical landmarks representing the vessels bifurcation points distributed across the lungs. The registration error is not significantly affected by the element type or linearity of analysis, with an average vector error of around 2.8 mm. The displacement differences between linear and nonlinear analysis methods are calculated for all lungs nodes and a maximum value of 3.6 mm is found in one of the nodes near the entrance of the bronchial tree into the lungs. The 95 percentile of displacement difference ranges between 0.4 and 0.8 mm. However, the time required for the analysis is reduced from 95 min in the quadratic elements nonlinear geometry model to 3.4 min in the linear element linear geometry model. Therefore using linear tetrahedral elements with linear elastic materials and linear geometry is preferable for modeling the breathing motion of lungs for image-guided radiotherapy applications.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/efectos de la radiación , Fenómenos Mecánicos , Radioterapia Asistida por Computador/métodos , Fenómenos Biomecánicos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/fisiopatología , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Inhalación , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/fisiopatología , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Tomografía Computarizada por Rayos X
3.
Phys Med Biol ; 55(21): 6491-500, 2010 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-20959687

RESUMEN

Deformable image registration of four head and neck cancer patients has been conducted using a biomechanical-based model. Patient-specific 3D finite element models have been developed using CT and cone-beam CT image data of the planning and a radiation treatment session. The model consists of seven vertebrae (C1 to C7), mandible, larynx, left and right parotid glands, tumor and body. Different combinations of boundary conditions are applied in the model in order to find the configuration with a minimum registration error. Each vertebra in the planning session is individually aligned with its correspondence in the treatment session. Rigid alignment is used for each individual vertebra and the mandible since no deformation is expected in the bones. In addition, the effect of morphological differences in the external body between the two image sessions is investigated. The accuracy of the registration is evaluated using the tumor and both parotid glands by comparing the calculated Dice similarity index of these structures following deformation in relation to their true surface defined in the image of the second session. The registration is improved when the vertebrae and mandible are aligned in the two sessions with the highest average Dice index of 0.86 ± 0.08, 0.84 ± 0.11 and 0.89 ± 0.04 for the tumor, left and right parotid glands, respectively. The accuracy of the center of mass location of tumor and parotid glands is also improved by deformable image registration where the errors in the tumor and parotid glands decrease from 4.0 ± 1.1, 3.4 ± 1.5 and 3.8 ± 0.9 mm using rigid registration to 2.3 ± 1.0, 2.5 ± 0.8 and 2.0 ± 0.9 mm in the deformable image registration when alignment of vertebrae and mandible is conducted in addition to the surface projection of the body.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Fenómenos Biomecánicos , Neoplasias de Cabeza y Cuello/patología , Humanos , Modelos Anatómicos , Planificación de la Radioterapia Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA