Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arthroscopy ; 33(4): 766-772, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28063761

RESUMEN

PURPOSE: To compare radiographic and 3-dimensional (3D) computed tomography (CT) imaging modalities for the screening of anterior inferior iliac spine (AIIS) impingement by establishing imaging measurement related to the AIIS. METHODS: Anteroposterior and false-profile radiographs and 3D CT scans were obtained on 10 human cadaveric pelvises. On the anteroposterior view for each methodology, 2 measurements were calculated: distance to the most lateral AIIS from the 12 o'clock position on the acetabular rim, and the angle between the lateral AIIS and the sagittal plane. On the false-profile view for each methodology, 2 measurements were calculated: distance to the anterior AIIS from the 12 o'clock position on the acetabular rim, and the angle between the anterior AIIS and the sagittal plane. Inter-rater and intrarater reliability analyses were performed for both methods in addition to an intermethod analysis. RESULTS: The radiographic false-profile view was the most repeatable orientation, with intraclass correlation coefficients showing excellent reproducibility in both inter-rater (angle: 0.980, distance: 0.883) and intrarater (angle: 0.995, distance: 0.995) analyses. The mean distance from the 12 o'clock position of the acetabular rim to the most anterior/lateral aspect of the AIIS was 41.4 mm and 16.0 mm on the radiographic false-profile and anteroposterior views, respectively. Intermethod analysis showed a systematic, quantitative bias between modalities (anteroposterior view: -4.1 mm, 6.7°; false-profile view: -0.1 mm, 8.3°), which will remain relatively consistent as evidenced by the strong individual reproducibility of each measurement. CONCLUSIONS: AIIS morphology in relation to the acetabular rim 12 o'clock position and its angle relative to the sagittal plane can be quantitatively determined using either radiographic or 3D CT imaging modalities. CLINICAL RELEVANCE: Radiographic evaluation may be a valuable tool in the screening of AIIS impingement.


Asunto(s)
Pinzamiento Femoroacetabular/diagnóstico por imagen , Acetábulo/diagnóstico por imagen , Anciano , Femenino , Pinzamiento Femoroacetabular/patología , Humanos , Ilion/diagnóstico por imagen , Ilion/patología , Imagenología Tridimensional/métodos , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Hueso Púbico/diagnóstico por imagen , Radiografía , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
2.
Int Orthop ; 41(9): 1715-1721, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28497166

RESUMEN

PURPOSE: Varus failure is one of the most common failure modes following surgical treatment of proximal humeral fractures. Straight antegrade nails (SAN) theoretically provide increased stability by anchoring to the densest zone of the proximal humerus (subchondral zone) with the end of the nail. The aim of this study was to biomechanically investigate the characteristics of this "proximal anchoring point" (PAP). We hypothesized that the PAP would improve stability compared to the same construct without the PAP. METHODS: Straight antegrade humeral nailing was performed in 20 matched pairs of human cadaveric humeri for a simulated unstable two-part fracture. RESULTS: Biomechanical testing, with stepwise increasing cyclic axial loading (50-N increments each 100 cycles) at an angle of 20° abduction revealed significantly higher median loads to failure for SAN constructs with the PAP (median, 450 N; range, 200-1.000 N) compared to those without the PAP (median, 325 N; range, 100-500 N; p = 0.009). SAN constructs with press-fit proximal extensions (endcaps) showed similar median loads to failure (median, 400 N; range, 200-650 N), when compared to the undersized, commercially available SAN endcaps (median, 450 N; range, 200-600 N; p = 0.240). CONCLUSIONS: The PAP provided significantly increased stability in SAN constructs compared to the same setup without this additional proximal anchoring point. Varus-displacing forces to the humeral head were superiorly reduced in this setting. This study provides biomechanical evidence for the "proximal anchoring point's" rationale. Straight antegrade humeral nailing may be beneficial for patients undergoing surgical treatment for unstable proximal humeral fractures to decrease secondary varus displacement and thus potentially reduce revision rates.


Asunto(s)
Clavos Ortopédicos/efectos adversos , Fractura-Luxación/cirugía , Fijación Intramedular de Fracturas/métodos , Fracturas del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Femenino , Fijación Intramedular de Fracturas/efectos adversos , Humanos , Cabeza Humeral/cirugía , Masculino
3.
Orthop J Sports Med ; 5(7): 2325967117714242, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28748195

RESUMEN

BACKGROUND: A need exists for a functional anterior cruciate ligament (ACL) brace that dynamically supports the knee joint to match the angle-dependent forces of a native ACL, especially in the early postoperative period. PURPOSE/HYPOTHESIS: The purpose of this study was to quantify the posteriorly directed external forces applied to the anterior proximal tibia by both a static and a dynamic force ACL brace. The proximal strap forces applied by the static force brace were hypothesized to remain relatively constant regardless of knee flexion angle compared with those of the dynamic force brace. STUDY DESIGN: Controlled laboratory study. METHODS: Seven healthy adult males (mean age, 27.4 ± 3.4 years; mean height, 1.8 ± 0.1 m; mean body mass, 84.1 ± 11.3 kg) were fitted with both a static and a dynamic force ACL brace. Participants completed 3 functional activities: unloaded extension, sit-to-stand, and stair ascent. Kinematic data were collected using traditional motion-capture techniques while posteriorly directed forces applied to the anterior aspect of both the proximal and distal tibia were simultaneously collected using a customized pressure-mapping technique. RESULTS: The mean posteriorly directed forces applied to the proximal tibia at 30° of flexion by the dynamic force brace during unloaded extension (80.2 N), sit-to-stand (57.5 N), and stair ascent (56.3 N) activities were significantly larger, regardless of force setting, than those applied by the static force brace (10.1 N, 9.5 N, and 11.9 N, respectively; P < .001). CONCLUSION: The dynamic force ACL brace, compared with the static force brace, applied significantly larger posteriorly directed forces to the anterior proximal tibia in extension, where the ACL is known to experience larger in vivo forces. Further studies are required to determine whether the physiological behavior of the brace will reduce anterior knee laxity and improve long-term patient outcomes. CLINICAL RELEVANCE: ACL braces that dynamically restrain the proximal tibia in a manner similar to physiological ACL function may improve pre- and postoperative treatment.

4.
Foot Ankle Int ; 38(4): 436-442, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27920331

RESUMEN

BACKGROUND: The effect of ankle positioning during suture-button fixation for syndesmosis repair on range of motion (ROM) and anatomic reduction has yet to be investigated. The purpose of this cadaveric study was to compare the effects of 3 different ankle positions during suture-button repair on volumetric reduction of the syndesmosis, fibular displacement, and ROM of the ankle using 3-dimensional computed tomography (CT) analysis. The null hypothesis was that ankle position during fixation would not affect syndesmotic volume restoration, fibular displacement, or ROM. METHODS: Twelve matched pair (n = 24) human cadaveric specimens were used for this study. Prior to syndesmotic sectioning, ROM assessment and CT scans were performed. Following sectioning of the syndesmosis, specimens were repaired in plantarflexion, dorsiflexion, or neutral, and simulated postrepair ROM evaluations and CT scans were repeated. Least squares mean differences between repair groups and the preinjury state were compared by analysis of variance and Tukey's method. RESULTS: There were no significant differences between repair groups for volumetric reduction ( P = .917), fibular displacement (anterior-posterior, P = .805; medial-lateral, P = .949), or dorsiflexion capacity ( P = .249). Among all specimens, compared with the preinjury state, there was a significant mean ± SD volume reduction of 337 ± 400 mm3 and medial displacement of 1.9 ± 1.5 mm. CONCLUSION: This study failed to reject the null hypothesis and demonstrated that ankle flexion at the time of syndesmotic fixation with a suture-button construct had no significant in vitro effect on volume changes, fibular displacement, or dorsiflexion capacity. However, in comparison to the preinjured state, suture-button repair resulted in significant overcompression with respect to syndesmosis volume and medial displacement of the fibula. CLINICAL RELEVANCE: Ankle position at the time of syndesmotic fixation did not affect overall ankle ROM when using a suture-button construct; however, overcompression was observed in all positions. The clinical impact of syndesmotic overcompression remains largely unknown.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Peroné/cirugía , Fijación Interna de Fracturas/métodos , Rango del Movimiento Articular/fisiología , Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Humanos , Técnicas de Sutura , Tomografía Computarizada por Rayos X
5.
Foot Ankle Int ; 38(2): 208-214, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27733556

RESUMEN

BACKGROUND: Historically, syndesmosis injuries have been repaired with screw fixation; however, some suggest that suture-button constructs may provide a more accurate anatomic and physiologic reduction. The purpose of this study was to compare changes in the volume of the syndesmotic space following screw or suture-button fixation using a preinjury and postoperative 3-D computed tomography (CT) model. The null hypothesis was that no difference would be observed among repair techniques. METHODS: Twelve pairs of cadaveric specimens were dissected to identify the syndesmotic ligaments. Specimens were imaged with CT prior to the creation of a complete syndesmosis injury and were subsequently repaired using 1 of 3 randomly assigned techniques: (a) one 3.5-mm cortical screw, (b) 1 suture-button, and (c) 2 suture-buttons. Specimens were imaged postoperatively with CT. 3-D models of all scans and tibiofibular joint space volumes were calculated to assess restoration of the native syndesmosis. Analysis of variance and Tukey's method were used to compare least squares mean differences from the intact syndesmosis among repair techniques. RESULTS: For each of the 3 fixation methods, the total postoperative syndesmosis volume was significantly decreased relative to the intact state. The total mean decreases in volume compared with the intact state for the 1-suture-button construct, 2-suture-button construct, and syndesmotic screw were -561 mm3 (95% CI, -878 to -244), -964 mm3 (95% CI, -1281 to -647) and -377 mm3 (95% CI, -694 to -60), respectively. CONCLUSION: All repairs notably reduced the volume of the syndesmosis beyond the intact state. Fixation with 1 suture-button was not significantly different from screw or 2-suture-button fixation; however, fixation with 2 suture-buttons resulted in significantly decreased volume compared with screw fixation. CLINICAL RELEVANCE: The results of this study suggest that the 1-suture-button repair technique and the screw fixation repair technique were comparable for reduction of syndesmosis injuries, although both may overcompress the syndesmosis.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/anatomía & histología , Tornillos Óseos , Procedimientos Ortopédicos/métodos , Anclas para Sutura , Adulto , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/patología , Articulación del Tobillo/cirugía , Cadáver , Peroné/anatomía & histología , Peroné/cirugía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Tibia/anatomía & histología , Tibia/cirugía , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA