1.
Echocardiography ; 41(6): e15833, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38873982

RESUMEN

BACKGROUND: Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two-dimensional speckle-tracking echocardiography (2D-STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D-STE in the clinical routine. METHODS: A total of 136 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D-STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL). Several fetal cardiac parameters were calculated (end-diastolic diameter [ED], sphericity index [SI], global longitudinal strain [EndoGLS], fractional shortening [FS]) and assigned to gestational age (GA). Bland-Altman plots were used to test agreement between both operators. RESULTS: The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m2. The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was -18.57% ± 6.59 percentage points (pp) for the right and -19.58% ± 5.63 pp for the left ventricle, that of the expert -14.33% ± 4.88 pp and -16.37% ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular was almost constant. The statistical analysis for endoGLS showed a Bland-Altman-Bias of -4.24 pp ± 8.06 pp for the right and -3.21 pp ± 7.11 pp for the left ventricle. The Bland-Altman-Bias of the ED in both ventricles in all analyzed segments ranged from -.49 mm ± 1.54 mm to -.10 mm ± 1.28 mm, that for FS from -.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from -.38 ± .68 to -.15 ± .45. CONCLUSIONS: Between both operators, our data indicated that 2D-STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D-STE remains the domain of scientific-academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice "on-the-fly" cannot be recommended.


Asunto(s)
Ecocardiografía , Corazón Fetal , Ultrasonografía Prenatal , Humanos , Femenino , Embarazo , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiopatología , Ultrasonografía Prenatal/métodos , Ecocardiografía/métodos , Adulto , Reproducibilidad de los Resultados , Estudios de Factibilidad , Edad Gestacional
2.
BMC Med Imaging ; 22(1): 154, 2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-36056307

RESUMEN

BACKGROUND: The aim of this study was to evaluate the accuracy and reliability of a semiautomated volumetric approach (5D CNS+™) when examining fetuses with an apparent abnormal anatomy of the central nervous system (CNS). METHODS: Stored 3D volumes extracted from a cohort of > 1.400 consecutive 2nd and 3rd trimester pregnancies (range 15-36 gestational weeks) were analyzed using the semiautomatic software tool 5D CNS+™, enabling detailed reconstruction of nine diagnostic planes of the fetal brain. All 3D data sets were examined and judged for plane accuracy, the need for manual adjustment, and fetal CNS anomalies affecting successful plane reconstruction. RESULTS: Based on our data of 91 fetuses with structural cerebral anomalies, we were able to reveal details of a wide range of CNS anomalies with application of the 5D CNS+™ technique. The corresponding anatomical features and consecutive changes of neighboring structures could be clearly demonstrated. Thus, a profound assessment of the entire altered CNS anatomy could be achieved in nearly all cases. The comparison with matched controls showed a significant difference in volume acquisition (p < 0.001) and in need for manual adjustment (p < 0.001) but not in the drop-out rates (p = 0.677) of both groups. CONCLUSION: 5D CNS+™ is applicable in the majority of cases with brain lesions and constitutes a reliable tool even if the integrity of the fetal CNS is compromised by structural anomalies. Using volume data that were acquired in identical cutting sections needed for conventional biometry allows for detailed anatomic surveys grossly independent of the examiner's experience.


Asunto(s)
Imagenología Tridimensional , Ultrasonografía Prenatal , Sistema Nervioso Central/diagnóstico por imagen , Femenino , Feto/anomalías , Feto/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/métodos
3.
J Ultrasound Med ; 41(2): 355-364, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33830545

RESUMEN

OBJECTIVES: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model. METHODS: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated. RESULTS: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (-0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (-2.63 ± 7.69% and -3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns). CONCLUSIONS: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third-trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.


Asunto(s)
Peso Fetal , Ultrasonografía Prenatal , Brazo/diagnóstico por imagen , Peso al Nacer , Femenino , Edad Gestacional , Humanos , Embarazo , Estudios Prospectivos
4.
Fetal Pediatr Pathol ; 41(5): 871-880, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34689682

RESUMEN

BACKGROUND: Congenital multisystemic lesions with co-occurrence of non-random malformations, such as VACTERL-H or MURCS association, often pose serious threads to the newborn and still constitute an antenatal diagnostic dilemma. CASE REPORT: A malformed fetus with VACTERL-H association at 20 gestational weeks had a skin-covered neural tube defect (NTD) of the lower cervical spine, concomitant hydrocephalus, as well as unilateral multicystic dysplastic kidney and the suspicion of mullerian duct anomaly as potentially assigned to MURCS association. DISCUSSION/CONCLUSION: We were able to demonstrate how well-defined, standardized volumetric reconstruction of diagnostic views displaying fetal pathology in utero might aid early and precise diagnosis of multi-organ malformations. Application of modern diagnostic imaging tools is helpful in delineation of the most likely diagnoses (VACTERL-H vs. MURCS) as further specified during detailed pathologic work-up and might consequently facilitate individually tailored interdisciplinary counseling, as in the case presented here.


Asunto(s)
Anomalías Múltiples , Cardiopatías Congénitas , Hidrocefalia , Deformidades Congénitas de las Extremidades , Riñón Displástico Multiquístico , Trastornos del Desarrollo Sexual 46, XX , Anomalías Múltiples/diagnóstico , Anomalías Múltiples/patología , Canal Anal/anomalías , Anomalías Cardiovasculares , Anomalías Congénitas , Anomalías del Sistema Digestivo , Esófago/anomalías , Femenino , Feto/patología , Enfermedades Genéticas Ligadas al Cromosoma X , Cardiopatías Congénitas/patología , Humanos , Hidrocefalia/diagnóstico , Hidrocefalia/patología , Riñón/anomalías , Riñón/patología , Deformidades Congénitas de las Extremidades/diagnóstico , Conductos Paramesonéfricos/anomalías , Conductos Paramesonéfricos/patología , Riñón Displástico Multiquístico/complicaciones , Riñón Displástico Multiquístico/diagnóstico , Riñón Displástico Multiquístico/patología , Anomalías Musculoesqueléticas , Embarazo , Columna Vertebral/anomalías , Columna Vertebral/patología , Tráquea/anomalías
5.
Echocardiography ; 38(5): 777-789, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33778977

RESUMEN

Volume ultrasound has been shown to provide valid complementary information on fetal anatomy. Four-dimensional assessment (4D) of the fetal cardiovascular system using spatial-temporal image correlation (STIC) allows for detailed examination of a highly complex organ from the early second trimester onward. There is compelling evidence that this technique harbors quite a number of diagnostic opportunities, but manual navigation through STIC volume datasets is highly operator dependent. In fact, STIC is not incorporated yet into daily practice. Application of the novel fetal intelligent navigation echocardiography (FINE) considerably simplifies fetal cardiac volumetric examinations. This automatic technique applied on cardiac volume datasets reportedly has both high sensitivity and specificity for the detection of congenital heart defects (CHDs). Part I reviewed current data regarding detection rates of CHDs and illustrated the additional value of an automatic approach in delineating cardiac anatomy exemplified by congenital lesions of the right heart. In part II of this pictorial essay, we focused on left heart anomalies and aimed to tabulate recent findings on the quantification of normal and abnormal cardiac anatomy.


Asunto(s)
Corazón Fetal , Cardiopatías Congénitas , Ecocardiografía , Ecocardiografía Tetradimensional , Femenino , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Embarazo , Segundo Trimestre del Embarazo , Ultrasonografía Prenatal
6.
Echocardiography ; 38(8): 1430-1445, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34232534

RESUMEN

Attempting a comprehensive examination of the fetal heart remains challenging for unexperienced operators as it emphasizes the acquisition and documentation of sequential cross-sectional and sagittal views and inevitably results in diminished detection rates of fetuses affected by congenital heart disease. The introduction of four-dimensional spatio-temporal image correlation (4D STIC) technology facilitated a volumetric approach for thorough cardiac anatomic evaluation by the acquisition of cardiac 4D datasets. By analyzing and re-arranging of numerous frames according to their temporal event within the heart cycle, STIC allows visualization of cardiac structures as an endless cine loop sequence of a complete single cardiac cycle in motion. However, post-analysis with manipulation and repeated slicing of the volume usually requires experience and in-depth anatomic knowledge, which limits the widespread application of this advanced technique in clinical care and unfortunately leads to the underestimation of its diagnostic value to date. Fetal intelligent navigation echocardiography (FINE), a novel method that automatically generates and displays nine standard fetal echocardiographic views in normal hearts, has shown to be able to overcome these limitations. Very recent data on the detection of congenital heart defects (CHDs) using the FINE method revealed a high sensitivity and specificity of 98% and 93%, respectively. In this two-part manuscript, we focused on the performance of FINE in delineating abnormal anatomy of typical right and left heart lesions and thereby emphasized the educational potential of this technology for more than just teaching purposes. We further discussed recent findings in a pathophysiological and/or functional context.


Asunto(s)
Ecocardiografía Tetradimensional , Cardiopatías Congénitas , Estudios Transversales , Femenino , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Embarazo , Ultrasonografía Prenatal
7.
J Ultrasound Med ; 40(1): 91-100, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32583930

RESUMEN

OBJECTIVES: We investigated the feasibility of a semiautomatic approach for assessments of the fetal heart (fetal intelligent navigation echocardiography [FINE]) in cases of optimal and unfavorable fetal spine positions. METHODS: In this study, a total of 1693 spatiotemporal image correlation volumes of first-, second-, and third-trimester fetuses were evaluated by experts using the FINE approach. The data were analyzed regarding proper reconstruction of the diagnostic cardiac planes depending on the fetal spine position. RESULTS: A total of 1531 volumes were included. The volumes were divided into 4 groups depending on the fetal spine position: 5-7 o'clock, 4 + 8 o'clock, 3 + 9 o'clock, and 2 + 10 o'clock. In total, 93.2% of the diagnostic planes were displayed properly. Between 5 and 7 o'clock, 94.9% of the diagnostic planes were displayed properly. The correct depiction rates in the other groups were 92.4% (4 + 8 o'clock; n = 538; P = 0.0027), 88.3% (3 + 9 o'clock; n = 156; P < .0001), and 87.3% (2 + 10 o'clock; n = 41; P = .0139). In total, the highest dropout rates were found in the sagittal planes: ductal arch, 13.9%; aortic arch, 10.5%; and venae cavae, 12.0%. CONCLUSIONS: Based on our results, the FINE technique is an effective method, but its feasibility depends on the fetal position. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized manner. Semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.


Asunto(s)
Corazón Fetal , Ultrasonografía Prenatal , Ecocardiografía , Estudios de Factibilidad , Femenino , Corazón Fetal/diagnóstico por imagen , Humanos , Embarazo , Columna Vertebral
8.
Childs Nerv Syst ; 36(12): 2989-2995, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32350601

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the validity of a semiautomated volumetric approach (5DCNS+) for the detailed assessment of the fetal brain in a clinical setting. METHODS: Stored 3D volumes of > 1100 consecutive 2nd and 3rd trimester pregnancies (range 15-36 gestational weeks) were analyzed using a workflow-based volumetric approach 5DCNS+, enabling semiautomated reconstruction of diagnostic planes of the fetal central nervous system (CNS). All 3D data sets were examined for plane accuracy, the need for manual adjustment, and fetal-maternal characteristics affecting successful plane reconstruction. We also examined the potential of these standardized views to give additional information on proper gyration and sulci formation with advancing gestation. RESULTS: Based on our data, we were able to show that gestational age with an OR of 1.085 (95% CI 1.041-1.132) and maternal BMI with an OR of 1.022 (95% CI 1.041-1.054) only had a slight impact on the number of manual adjustments needed to reconstruct the complete volume, while maternal age and fetal position during acquisition (p = 0.260) did not have a significant effect. For the vast majority (958/1019; 94%) of volumes, using 5DCNS+ resulted in proper reconstruction of all nine diagnostic planes. In less than 1% (89/9171 planes) of volumes, the program failed to give sufficient information. 5DCNS+ was able to show the onset and changing appearance of CNS folding in a detailed and timely manner (lateral/parietooccipital sulcus formation seen in < 65% at 16-17 gestational weeks vs. 94.6% at 19 weeks). CONCLUSIONS: The 5DCNS+ method provides a reliable algorithm to produce detailed, 3D volume-based assessments of fetal CNS integrity through a standardized reconstruction of the orthogonal diagnostic planes. The method further gives valid and reproducible information regarding ongoing cortical development retrieved from these volume sets that might aid in earlier in utero recognition of subtle structural CNS anomalies.


Asunto(s)
Malformaciones del Sistema Nervioso , Ultrasonografía Prenatal , Femenino , Feto/diagnóstico por imagen , Edad Gestacional , Humanos , Imagenología Tridimensional , Embarazo , Tercer Trimestre del Embarazo
9.
J Ultrasound Med ; 39(2): 301-309, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31411353

RESUMEN

OBJECTIVES: To investigate the interobserver and intraobserver variability and corresponding learning curve in a semiautomatic approach for a standardized assessment of the fetal heart (fetal intelligent navigation echocardiography [FINE]). METHODS: A total of 30 stored spatiotemporal image correlation volume data sets of second-trimester fetuses were evaluated by 3 physicians with different levels of expertise in fetal echocardiography by using the FINE approach. Data were analyzed regarding the examination time and proper reconstruction of the diagnostic cardiac planes. The completions and numbers of correct depictions of all diagnostic planes were evaluated by a blinded expert (time t0). To determine interobserver and intraobserver variability, the volumes were reassessed after a 4-week training interval (time t1). RESULTS: All operators were able to perform the investigation on all 30 volumes. At t0, the interobserver variability between the beginner and both the advanced (P = .0013) and expert (P < .0001) examiners was high. Focusing on intraobserver variability at t1, the beginner showed a marked improvement (P = .0087), whereas in advanced and expert hands, no further improvement regarding proper achievement of all diagnostic planes could be noticed (P > .999; P = .8383). The beginner also showed improvement in the mean investigation time (t0, 82.8 seconds; t1, 73.4 seconds; P = .0895); nevertheless, the advanced and expert examiners were faster in completing the examination (t1, advanced, 20.9 seconds; expert, 28.3 seconds; each P < .0001). CONCLUSIONS: Based on our results, the FINE technique is a reliable and easily learned method. The use of this semiautomatic work flow-based approach supports evaluation of the fetal heart in a standardized and time-saving manner. A semiautomatic evaluation of the fetal heart might be useful in facilitating the detection of fetal cardiac anomalies.


Asunto(s)
Inteligencia Artificial , Competencia Clínica , Ecocardiografía Tetradimensional/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Femenino , Humanos , Curva de Aprendizaje , Variaciones Dependientes del Observador , Embarazo , Segundo Trimestre del Embarazo
10.
J Ultrasound Med ; 37(12): 2841-2847, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29665042

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the feasibility of sonographic assessment of the embryonic/fetal neural tube in nonviable pregnancies and to determine the defect incidence. METHODS: Prospective analysis of transvaginally acquired 3-dimensional (3D) multiplanar and 3D surface-rendered volume sets of 340 cases of missed abortion between March 2010 and September 2015 was performed. Data regarding karyotype and postmortem examination as well as demographic features and the outcomes of subsequent pregnancies were evaluated. RESULTS: In 223 cases, an embryo/fetus was detected and considered suitable for further evaluation: in 37 of 223 (16.6%) embryos/fetuses, a neural tube defect was present: 27 of 37 cephaloceles, 5 of 37 anencephalies/exencepahlies, 3 of 37 spina bifidas, 1 of 37 caudal regression syndrome, and 1 of 37 iniencephaly. Additional alterations were not observed. In 7 of 37 cases karyotyping was carried out and showed no aneuploidy. Eight subsequent pregnancies had a favorable outcome, with 1 ending in an intrauterine fetal death during the 22nd week of gestation. Maternal folic acid supplementation was provided for all subsequent pregnancies. No neural tube defects occurred. CONCLUSIONS: Sonographic 3D evaluation of complete neural tube closure in embryonic/fetal demise is technically feasible and can be achieved in embryos with a crown-rump length greater than 8 mm. In 26 of 37 cases a defective closure site could be allocated to high-risk areas known for early embryonic demise. Regardless of the etiology of different neural tube defects, high-dose folic acid prophylaxis must be recommended in all cases. Sonographic evaluation of the neural tube, including 3D surface-rendered images, should be offered to every woman with a missed abortion because of the impact on subsequent pregnancies.


Asunto(s)
Aborto Retenido/diagnóstico por imagen , Defectos del Tubo Neural/diagnóstico por imagen , Defectos del Tubo Neural/embriología , Ultrasonografía Prenatal/métodos , Adulto , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional/métodos , Embarazo , Estudios Prospectivos
11.
Arch Gynecol Obstet ; 296(3): 455-463, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28634753

RESUMEN

PURPOSE: To scrutinize the characteristics of all cases with antenatally established diagnosis of cephalocele in two tertiary referral centers. METHODS: We retrospectively reviewed 65 cases diagnosed with cephaloceles and tabulated sonographic findings and autopsy recordings as well as medical charts of all survivors in terms of clinical outcome. RESULTS: The case notes of 65 fetuses were available for final analysis. Gestational age (GA) at diagnosis ranged from 10.4 to 38.1 weeks. Of our cohort, 53/65 cases (80%) had occipital protrusions, 10 (15%) were found to have frontal lesions, and another two had parietal cephaloceles. A total of 52 pregnancies were terminated or resulted in intrauterine fetal demise (78%). In 18 cases (11%), the cephalocele was part of underlying syndromic disorders (e.g., Meckel-Gruber syndrome). Thirteen pregnancies were continued until term, out of which all affected individuals were live-born. Neurosurgical intervention was prompted within the first 7 months postnatally. CONCLUSIONS: In general, the outcome of fetuses with cephaloceles is rather poor as four out of five pregnancies were terminated. Postnatal outcome of all survivors in our cohort was rather determined by localization of the cele and more important by the presence and severity of concomitant malformations than the extent of the lesion.


Asunto(s)
Encefalocele/diagnóstico por imagen , Encefalocele/patología , Femenino , Edad Gestacional , Humanos , Masculino , Embarazo , Resultado del Embarazo , Diagnóstico Prenatal , Estudios Retrospectivos , Ultrasonografía Prenatal
12.
Arch Gynecol Obstet ; 293(5): 987-92, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26498605

RESUMEN

PURPOSE: Pregnant women with a body-mass-index (BMI) above 50 are referred to as "super-obese". For these women adverse pregnancy outcome and a higher risk of fetal congenital defects are major issues. This report focuses on the ratio development of super-obesity in pregnant women, as well as on prenatal ultrasound and pregnancy outcome in the super-obese gravida. METHODS: We reviewed data of all women with a BMI above 30 who delivered at our unit in a 15-year period between January 2000 and December 2014. Data of obese but not super-obese mothers were evaluated in comparison. RESULTS: Final evaluation comprised 69/20,711 pregnancies of super-obese mothers. Forty out of 69 women suffered from a preexisting condition requiring medical treatment. Fetal ultrasound evaluation revealed severe congenital defects in four cases. There were no missed and no false positive diagnoses. Elective cesarean section (c-section) took place in 26/69 cases, 21/69 had a secondary c-section. Twenty-two out of 69 women delivered vaginally. Mean gestational age at delivery was 38(+6) gestational weeks. Pregnancy was complicated by macrosomia in 17/69 pregnancies. Severe neonatal hypoglycemia occurred in 6/69 cases. The number of deliveries by super-obese mothers showed no marked variation during the study period. In contrast the rate of deliveries by obese, but not super-obese, mothers showed an increase. CONCLUSIONS: Maternal super-obesity poses a high-risk situation for mother and child which generally demands a higher amount of perinatal care. The number of deliveries by super-obese mothers remained stable over the study period. Primary c-section was the most frequent mode of delivery. Of the parturients who opted for vaginal delivery nearly half of the deliveries had to be completed by secondary c-section. Over-all peripartal maternal complications did not exceed average.


Asunto(s)
Índice de Masa Corporal , Obesidad Mórbida/epidemiología , Complicaciones del Embarazo/epidemiología , Ultrasonografía Prenatal/métodos , Adulto , Peso al Nacer , Cesárea/estadística & datos numéricos , Comorbilidad , Parto Obstétrico/métodos , Diabetes Gestacional/epidemiología , Femenino , Edad Gestacional , Humanos , Hipertensión Inducida en el Embarazo/epidemiología , Recién Nacido , Obesidad Mórbida/diagnóstico , Embarazo , Complicaciones del Embarazo/diagnóstico , Resultado del Embarazo , Embarazo en Diabéticas/epidemiología
13.
J Clin Med ; 12(16)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37629375

RESUMEN

(1) Objective: We aimed to evaluate the accuracy and efficacy of AI-assisted biometric measurements of the fetal central nervous system (CNS) by comparing two semiautomatic postprocessing tools. We further aimed to discuss the additional value of semiautomatically generated sagittal and coronal planes of the CNS. (2) Methods: Three-dimensional (3D) volumes were analyzed with two semiautomatic software tools, 5DCNS+™ and SonoCNS™. The application of 5DCNS+™ results in nine planes (axial, coronal and sagittal) displayed in a single template; SonoCNS™ depicts three axial cutting sections. The tools were compared regarding automatic biometric measurement accuracy. (3) Results: A total of 129 fetuses were included for final analysis. Our data indicate that, in terms of the biometric quantification of head circumference (HC), biparietal diameter (BPD), transcerebellar diameter (TCD) and cisterna magna (CM), the accuracy of SonoCNS™ was higher with respect to the manual measurement of an experienced examiner compared to 5DCNS+™, whereas it was the other way around regarding the diameter of the posterior horn of the lateral ventricle (Vp). The inclusion of four orthogonal coronal views in 5DCNS+™ gives valuable information regarding spatial arrangements, particularly of midline structures. (4) Conclusions: Both tools were able to ease assessment of the intracranial anatomy, highlighting the additional value of automated algorithms in clinical use. SonoCNS™ showed a superior accuracy of plane reconstruction and biometry, but volume reconstruction using 5DCNS+™ provided more detailed information, which is needed for an entire neurosonogram as suggested by international guidelines.

14.
Cureus ; 15(4): e38052, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37228519

RESUMEN

OBJECTIVE: To assess the performance of fetal intelligent navigation echocardiography (FINE, 5D Heart™) for automated volumetric investigation of the fetal heart in twin pregnancies. METHODS: Three hundred twenty-eight twin fetuses underwent fetal echocardiography in the second and third trimesters. Spatiotemporal image correlation (STIC) volumes were obtained for a volumetric investigation. The volumes were analyzed using the FINE software, and the data were investigated regarding image quality and many properly reconstructed planes. RESULTS: Three hundred and eight volumes underwent final analysis. 55.8% of the included pregnancies were dichorionic twin pregnancies, and 44.2% were monochorionic twin pregnancies. The mean gestational age (GA) was 22.1 weeks, and the mean maternal BMI was 27.3 kg/m2. The STIC-volume acquisition was successful in 100.0% and 95.5% of cases. The overall depiction rates of FINE were 96.5% (twin 1) and 94.7% (twin 2), respectively (p = 0.0849, not significant). In 95.9% (twin 1) and 93.9% (twin 2), at least 7 planes were reconstructed properly (p = 0.6056, not significant). CONCLUSION: Our results indicate that the FINE technique used in twin pregnancies is reliable. No significant difference between the depiction rates of twin 1 and twin 2 could be detected. In addition, the depiction rates are as high as those derived from singleton pregnancies. Due to the challenges of fetal echocardiography in twin pregnancies (i.e., greater rates of cardiac anomaly and more difficult scans), the FINE technique might be a valuable tool to improve the quality of medical care in those pregnancies.

15.
J Clin Med ; 12(19)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37835015

RESUMEN

Congenital heart disease (CHD) is one of the most common organ-specific birth defects and a major cause of infant morbidity and mortality. Despite ultrasound screening guidelines, the detection rate of CHD is limited. Fetal intelligent navigation echocardiography (FINE) has been introduced to extract reference planes and cardiac axis from cardiac spatiotemporal image correlation (STIC) volume datasets. This study analyses the cardiac axis in fetuses affected by CHD/thoracic masses (n = 545) compared to healthy fetuses (n = 1543) generated by FINE. After marking seven anatomical structures, the FINE software generated semi-automatically nine echocardiography standard planes and calculated the cardiac axis. Our study reveals that depending on the type of CHD, the cardiac axis varies. In approximately 86% (471 of 542 volumes) of our pathological cases, an abnormal cardiac axis (normal median = 40-45°) was detectable. Significant differences between the fetal axis of the normal heart versus CHD were detected in HLHS, pulmonary atresia, TOF (p-value < 0.0001), RAA, situs ambiguus (p-value = 0.0001-0.001) and absent pulmonary valve syndrome, DORV, thoracic masses (p-value = 0.001-0.01). This analysis confirms that in fetuses with CHD, the cardiac axis can significantly deviate from the normal range. FINE appears to be a valuable tool to identify cardiac defects.

16.
Diagnostics (Basel) ; 13(10)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37238193

RESUMEN

(1) Objectives: In utero functional cardiac assessments using echocardiography have become increasingly important. The myocardial performance index (MPI, Tei index) is currently used to evaluate fetal cardiac anatomy, hemodynamics and function. An ultrasound examination is highly examiner-dependent, and training is of enormous significance in terms of proper application and subsequent interpretation. Future experts will progressively be guided by applications of artificial intelligence, on whose algorithms prenatal diagnostics will rely on increasingly. The objective of this study was to demonstrate the feasibility of whether less experienced operators might benefit from an automated tool of MPI quantification in the clinical routine. (2) Methods: In this study, a total of 85 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by a targeted ultrasound. The modified right ventricular MPI (RV-Mod-MPI) was measured, both by a beginner and an expert. A calculation was performed semiautomatically using a Samsung Hera W10 ultrasound system (MPI+™, Samsung Healthcare, Gangwon-do, South Korea) by taking separate recordings of the right ventricle's in- and outflow using a conventional pulsed-wave Doppler. The measured RV-Mod-MPI values were assigned to gestational age. The data were compared between the beginner and the expert using a Bland-Altman plot to test the agreement between both operators, and the intraclass correlation was calculated. (3) Results: The mean maternal age was 32 years (19 to 42 years), and the mean maternal pre-pregnancy body mass index was 24.85 kg/m2 (ranging from 17.11 to 44.08 kg/m2). The mean gestational age was 24.44 weeks (ranging from 19.29 to 36.43 weeks). The averaged RV-Mod-MPI value of the beginner was 0.513 ± 0.09, and that of the expert was 0.501 ± 0.08. Between the beginner and the expert, the measured RV-Mod-MPI values indicated a similar distribution. The statistical analysis showed a Bland-Altman bias of 0.01136 (95% limits of agreement from -0.1674 to 0.1902). The intraclass correlation coefficient was 0.624 (95% confidence interval from 0.423 to 0.755). (4) Conclusions: For experts as well as for beginners, the RV-Mod-MPI is an excellent diagnostic tool for the assessment of fetal cardiac function. It is a time-saving procedure, offers an intuitive user interface and is easy to learn. There is no additional effort required to measure the RV-Mod-MPI. In times of reduced resources, such assisted systems of fast value acquisition represent clear added value. The establishment of the automated measurement of the RV-Mod-MPI in clinical routine should be the next level in cardiac function assessment.

17.
J Med Biogr ; 31(2): 94-98, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35341377

RESUMEN

'Making the invisible visible' is a requirement of a coveted prize for scientific photography - the Lennart Nilsson Award - which is named after the pioneer of human embryo photography. There is no way of avoiding his influence if the hitherto invisible is to be made visible, the intangible almost tangible, the unimaginable made imaginable, and mysteries otherwise hidden from the human eye are to be processed in a popular-scientific way and visualized in an artistic way by means of scientific-medical imaging techniques. Whilst Lennart Nilsson used state-of-the-art imaging technology within the rapidly evolving field of endoscopy, he also created what is probably the best-selling illustrated book of all times with A Child Is Born contributing to both the further understanding of early prenatal development, as well as achieving worldwide popularity.


Asunto(s)
Arte , Fotograbar , Embarazo , Femenino , Niño , Humanos
18.
Twin Res Hum Genet ; 15(4): 532-6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22853920

RESUMEN

The increasing rates of preterm birth among twins implicate that solid data on associated risks and outcomes are required. Assessment of zygosity is often based on clinical criteria (evaluation of placenta; same gender, birth weight discordance as surrogate criteria for monochorionic/monozygotic twins). The aim of this study was to compare clinical versus genetic assessment of zygosity and to compare causes of preterm delivery as well as outcome data of very-low-birth-weight (VLBW; birth weight <1,500 g) twins stratified to zygosity. In a multicenter study, we selected n=176 sets of same gender twins and determined zygosity genetically. In a subgroup of 123 sets of twins, the attending physicians at the study centers were asked to document the parameter 'zygosity' (monozygotic/dizygotic) on the basis of their clinical judgment. Concordance between genetic and clinical assessment was 62.7% for monozygotic twins and 88.9% for dizygotic twins, respectively. Outcome parameters (death, BPD, ROP, NEC, IVH) were comparable in both groups. Genetically dizygotic twins were significantly more often born due to intrauterine infection (33% vs. 20% in monozygotic twins, p<.01) and antenatal antibiotics were more frequently given to mothers of dizygotic twins (62% vs. 47% in monozygotic twins, p<.01). Obstetric complications such as twin-twin-transfusion-syndrome were only seen in monozygotic twins as expected. The unexpected increase of antenatal antibiotic treatment and birth due to intrauterine infection in dizygotic twins should be confirmed in additional VLBW twin-cohorts.


Asunto(s)
Recien Nacido Prematuro , Embarazo Gemelar , Nacimiento Prematuro/etiología , Gemelos Dicigóticos , Gemelos Monocigóticos , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recién Nacido de muy Bajo Peso , Masculino , Embarazo , Complicaciones del Embarazo , Resultado del Embarazo , Factores de Riesgo
19.
J Ultrasound Med ; 31(8): 1285-91, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22837295

RESUMEN

Premature constriction or closure of the ductus arteriosus can occur during fetal life. It is a rare phenomenon and has been described secondary to medication or structural lesions or as idiopathic constriction. Premature closure of the ductus arteriosus can lead to progressive right heart dysfunction with tricuspid regurgitation, congestive heart failure, fetal hydrops, and intrauterine death. This series describes diagnosis of fetal ductus arteriosus constriction of unknown etiology in 3 cases, prenatal management, and outcomes. Constriction of the ductus arteriosus can be diagnosed prenatally with careful interrogation of the ductal arch using pulsed Doppler sonography and complete fetal echocardiography. Close monitoring is mandatory to rule out development of right heart failure and to determine the intervention time.


Asunto(s)
Conducto Arterial/diagnóstico por imagen , Enfermedades Fetales/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/patología , Diagnóstico Diferencial , Conducto Arterial/patología , Ecocardiografía , Femenino , Enfermedades Fetales/patología , Humanos , Recién Nacido , Masculino , Embarazo , Resultado del Embarazo
20.
Arch Gynecol Obstet ; 286(1): 81-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22392490

RESUMEN

OBJECTIVES: We analyse the prenatal detection and pregnancy outcome of twin reversed arterial perfusion syndrome (TRAP-sequence) in monochorionic twin pregnancies. METHODS: We included all cases in which the prenatal diagnosis of a TRAP-sequence had been established and reviewed the prenatal, obstetrical, and pathological records of the acardiac twin as well as the neonatal/pediatric records of the donor twin. Minimal follow-up for the donor twin after birth was 6 months. RESULTS: We detected six cases of TRAP-sequence in 412 examined monochorionic multiple pregnancies (incidence 1.46%) Mean gestational age at diagnosis was 20.4 (13.1-28.0) gestational weeks. All donor twins survived without detectable mid- or long-term sequelae. There was neither missed prenatal diagnosis nor a false-positive diagnosis of TRAP-sequence. Mean birthweight of the acardiac twins was 1,400 g (830-2800 g). There was an uneventful medical history in the maternal records of all included women. Fetal karyotype was available for 5/6 twin-pairs, all revealing a normal distribution of the chromosomes. All acardiac twins had post-mortem examination with specification of the subtypes of acardiac twin displaying 3/6 acardius acephalus, 2/6 acardius amorphus, and 1/6 acardius anceps. CONCLUSIONS: The antenatal diagnosis of TRAP-sequence is feasible and can be established during the first-trimester-screening. The discrimination of the adequate time to end the pregnancy, though a crucial concern, remains a challenging question. Future studies should address this topic.


Asunto(s)
Peso al Nacer , Transfusión Feto-Fetal/diagnóstico por imagen , Embarazo Triple , Embarazo Gemelar , Ultrasonografía Prenatal , Adulto , Cesárea , Femenino , Transfusión Feto-Fetal/genética , Transfusión Feto-Fetal/patología , Estudios de Seguimiento , Humanos , Recién Nacido , Cariotipo , Masculino , Embarazo , Resultado del Embarazo , Estudios Retrospectivos