Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Opt Express ; 31(10): 16709-16718, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37157744

RESUMEN

Optical sectioning structured illumination microscopy (OS-SIM) provides optical sectioning capability in wide-field microscopy. The required illumination patterns have traditionally been generated using spatial light modulators (SLM), laser interference patterns, or digital micromirror devices (DMDs) which are too complex to implement in miniscope systems. MicroLEDs have emerged as an alternative light source for patterned illumination due to their extreme brightness capability and small emitter sizes. This paper presents a directly addressable striped microLED microdisplay with 100 rows on a flexible cable (70 cm long) for use as an OS-SIM light source in a benchtop setup. The overall design of the microdisplay is described in detail with luminance-current-voltage characterization. OS-SIM implementation with a benchtop setup shows the optical sectioning capability of the system by imaging within a 500 µm thick fixed brain slice from a transgenic mouse where oligodendrocytes are labeled with a green fluorescent protein (GFP). Results show improved contrast in reconstructed optically sectioned images of 86.92% (OS-SIM) compared with 44.31% (pseudo-widefield). MicroLED based OS-SIM therefore offers a new capability for deep tissue widefield imaging.

2.
J Neurophysiol ; 115(4): 1821-35, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26719085

RESUMEN

Gamma oscillations are a robust component of sensory responses but are also part of the background spontaneous activity of the brain. To determine whether the properties of gamma oscillations in cortex are specific to their mechanism of generation, we compared in mouse visual cortex in vivo the laminar geometry and single-neuron rhythmicity of oscillations produced during sensory representation with those occurring spontaneously in the absence of stimulation. In mouse visual cortex under anesthesia (isoflurane and xylazine), visual stimulation triggered oscillations mainly between 20 and 50 Hz, which, because of their similar functional significance to gamma oscillations in higher mammals, we define here as gamma range. Sensory representation in visual cortex specifically increased gamma oscillation amplitude in the supragranular (L2/3) and granular (L4) layers and strongly entrained putative excitatory and inhibitory neurons in infragranular layers, while spontaneous gamma oscillations were distributed evenly through the cortical depth and primarily entrained putative inhibitory neurons in the infragranular (L5/6) cortical layers. The difference in laminar distribution of gamma oscillations during the two different conditions may result from differences in the source of excitatory input to the cortex. In addition, modulation of superficial gamma oscillation amplitude did not result in a corresponding change in deep-layer oscillations, suggesting that superficial and deep layers of cortex may utilize independent but related networks for gamma generation. These results demonstrate that stimulus-driven gamma oscillations engage cortical circuitry in a manner distinct from spontaneous oscillations and suggest multiple networks for the generation of gamma oscillations in cortex.


Asunto(s)
Ritmo Gamma , Corteza Visual/fisiología , Animales , Potenciales Evocados Visuales , Ratones , Ratones Endogámicos C57BL , Neuronas/fisiología , Corteza Visual/citología
3.
bioRxiv ; 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38766201

RESUMEN

Myelin loss in the central nervous system can cause permanent motor or cognitive deficits in patients with multiple sclerosis (MS). While current immunotherapy treatments decrease the frequency of demyelinating episodes, they do not promote myelin repair or functional recovery. Vagus nerve stimulation (VNS) is a neuromodulation therapy which enhances neuroplasticity and the recovery of motor function after stroke, but its effects on myelin repair are not known. To determine if VNS influences myelin repair, we applied VNS following a demyelinating injury and measured longitudinal myelin dynamics and functional recovery. We found that VNS promotes remyelination by increasing the generation of myelinating oligodendrocytes. Pairing VNS with a skilled reach task leads to the regeneration of myelin sheaths on previously myelinated axon segments, enhancing the restoration of the original pattern of myelination. Moreover, the magnitude of sheath pattern restoration correlates with long-term motor functional improvement. Together, these results suggest that recovery of the myelin sheath pattern is a key factor in the restoration of motor function following myelin loss and identify paired VNS as a potential remyelination therapy to treat demyelinating diseases.

4.
Front Hum Neurosci ; 18: 1320806, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38450221

RESUMEN

The Deep Brain Stimulation (DBS) Think Tank XI was held on August 9-11, 2023 in Gainesville, Florida with the theme of "Pushing the Forefront of Neuromodulation". The keynote speaker was Dr. Nico Dosenbach from Washington University in St. Louis, Missouri. He presented his research recently published in Nature inn a collaboration with Dr. Evan Gordon to identify and characterize the somato-cognitive action network (SCAN), which has redefined the motor homunculus and has led to new hypotheses about the integrative networks underpinning therapeutic DBS. The DBS Think Tank was founded in 2012 and provides an open platform where clinicians, engineers, and researchers (from industry and academia) can freely discuss current and emerging DBS technologies, as well as logistical and ethical issues facing the field. The group estimated that globally more than 263,000 DBS devices have been implanted for neurological and neuropsychiatric disorders. This year's meeting was focused on advances in the following areas: cutting-edge translational neuromodulation, cutting-edge physiology, advances in neuromodulation from Europe and Asia, neuroethical dilemmas, artificial intelligence and computational modeling, time scales in DBS for mood disorders, and advances in future neuromodulation devices.

5.
Neuron ; 110(17): 2867-2885.e7, 2022 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-35858623

RESUMEN

Vagus nerve stimulation (VNS) is a neuromodulation therapy for a broad and expanding set of neurologic conditions. However, the mechanism through which VNS influences central nervous system circuitry is not well described, limiting therapeutic optimization. VNS leads to widespread brain activation, but the effects on behavior are remarkably specific, indicating plasticity unique to behaviorally engaged neural circuits. To understand how VNS can lead to specific circuit modulation, we leveraged genetic tools including optogenetics and in vivo calcium imaging in mice learning a skilled reach task. We find that VNS enhances skilled motor learning in healthy animals via a cholinergic reinforcement mechanism, producing a rapid consolidation of an expert reach trajectory. In primary motor cortex (M1), VNS drives precise temporal modulation of neurons that respond to behavioral outcome. This suggests that VNS may accelerate motor refinement in M1 via cholinergic signaling, opening new avenues for optimizing VNS to target specific disease-relevant circuitry.


Asunto(s)
Enfermedades del Sistema Nervioso , Estimulación del Nervio Vago , Animales , Encéfalo , Colinérgicos/farmacología , Ratones , Enfermedades del Sistema Nervioso/terapia , Plasticidad Neuronal/fisiología , Estimulación del Nervio Vago/métodos
6.
Biomed Opt Express ; 13(4): 2530-2541, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35519247

RESUMEN

We present a high-resolution miniature, light-weight fluorescence microscope with electrowetting lens and onboard CMOS for high resolution volumetric imaging and structured illumination for rejection of out-of-focus and scattered light. The miniature microscope (SIMscope3D) delivers structured light using a coherent fiber bundle to obtain optical sectioning with an axial resolution of 18 µm. Volumetric imaging of eGFP labeled cells in fixed mouse brain tissue at depths up to 260 µm is demonstrated. The functionality of SIMscope3D to provide background free 3D imaging is shown by recording time series of microglia dynamics in awake mice at depths up to 120 µm in the brain.

7.
Elife ; 102021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33821789

RESUMEN

Vagus nerve stimulation (VNS) suppresses inflammation and autoimmune diseases in preclinical and clinical studies. The underlying molecular, neurological, and anatomical mechanisms have been well characterized using acute electrophysiological stimulation of the vagus. However, there are several unanswered mechanistic questions about the effects of chronic VNS, which require solving numerous technical challenges for a long-term interface with the vagus in mice. Here, we describe a scalable model for long-term VNS in mice developed and validated in four research laboratories. We observed significant heart rate responses for at least 4 weeks in 60-90% of animals. Device implantation did not impair vagus-mediated reflexes. VNS using this implant significantly suppressed TNF levels in endotoxemia. Histological examination of implanted nerves revealed fibrotic encapsulation without axonal pathology. This model may be useful to study the physiology of the vagus and provides a tool to systematically investigate long-term VNS as therapy for chronic diseases modeled in mice.


Asunto(s)
Electrodos Implantados/estadística & datos numéricos , Ratones/fisiología , Estimulación del Nervio Vago/instrumentación , Nervio Vago/fisiología , Animales , Fenómenos Electrofisiológicos , Masculino , Ratones Endogámicos C57BL , Modelos Animales
8.
Nat Neurosci ; 23(7): 819-831, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32424285

RESUMEN

Oligodendrocyte loss in neurological disease leaves axons vulnerable to damage and degeneration, and activity-dependent myelination may represent an endogenous mechanism to improve remyelination following injury. Here we report that, while learning a forelimb reach task transiently suppresses oligodendrogenesis, it subsequently increases oligodendrocyte precursor cell differentiation, oligodendrocyte generation and myelin sheath remodeling in the forelimb motor cortex. Immediately following demyelination, neurons exhibit hyperexcitability, learning is impaired and behavioral intervention provides no benefit to remyelination. However, partial remyelination restores neuronal and behavioral function, allowing learning to enhance oligodendrogenesis, remyelination of denuded axons and the ability of surviving oligodendrocytes to generate new myelin sheaths. Previously considered controversial, we show that sheath generation by mature oligodendrocytes is not only possible but also increases myelin pattern preservation following demyelination, thus presenting a new target for therapeutic interventions. Together, our findings demonstrate that precisely timed motor learning improves recovery from demyelinating injury via enhanced remyelination from new and surviving oligodendrocytes.


Asunto(s)
Aprendizaje/fisiología , Actividad Motora/fisiología , Oligodendroglía/fisiología , Recuperación de la Función/fisiología , Remielinización/fisiología , Animales , Diferenciación Celular/fisiología , Cuprizona/toxicidad , Enfermedades Desmielinizantes/inducido químicamente , Ratones , Ratones Endogámicos C57BL , Inhibidores de la Monoaminooxidasa/toxicidad , Corteza Motora/fisiología , Células Precursoras de Oligodendrocitos/fisiología
9.
Biomaterials ; 238: 119831, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32045783

RESUMEN

Implanted microelectrode arrays sense local neuronal activity, signals which are used as control commands for brain computer interface (BCI) technology. Patients with tetraplegia have used BCI technology to achieve an extraordinary degree of interaction with their local environment. However, current microelectrode arrays for BCIs lose the ability to record high-quality neural signals in the months-to-years following implantation. Very little is known regarding the dynamic response of neurons and vasculature in the months following electrode array implantation, but loss of structural integrity near the electrode may contribute to the degradation of recording signals. Here, we use in-vivo dual-modality imaging to characterize neuronal and vasculature structures in the same animal for 3 months following electrode insertion. We find ongoing neuronal atrophy, but relative vascular stability, in close proximity to the electrode, along with evidence suggesting links between rare, abrupt hypoxic events and neuronal process atrophy.


Asunto(s)
Neuronas , Animales , Electrodos Implantados , Humanos , Microelectrodos
10.
J Neurosci Methods ; 328: 108437, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31526764

RESUMEN

BACKGROUND: High-resolution peripheral nerve interfaces (PNIs) can provide amputees with intuitive motor control and sensory feedback. Current PNIs are limited by early device failure and suboptimal long-term stability. The present study aims to incorporate functional assessment into an in vivo test platform to assess the long-term safety and performance of PNIs for recording and stimulation. NEW METHODS: Utah electrode arrays (EA) were implanted in the rat sciatic nerve along with electromyography wires in the gastrocnemius and tibialis anterior. Cranial EEG screws were implanted in the somatosensory cortex for 12 weeks. Spontaneous neural activity was recorded using the implanted EA and stimulation-induced activity was monitored throughout the experiment. The impedance of each electrode was measured, and nerve function tests were conducted throughout the EA lifetime. Post-hoc safety assessments included scanning electron microscopy (SEM) of the EA and nerve histomorphometric analysis. RESULTS: EA recordings were stable, and stimulation with EA elicited somatosensory evoked potentials and muscle contractions. Motor and sensory function tests indicated minimal deficits. Histomorphometric analysis indicated changes in nerve microstructure. SEM indicated EA-tip fracture, while lead wire breakage primarily caused device failure. COMPARISON WITH EXISTING METHODS: We improved our prior platform with the addition of functional assessments of sensory pathways, a robust EMG array design to increase device longevity, and quantitative analysis of nerve microstructure. CONCLUSION: We present a test platform for long-term assessment of peripheral nerve interfaces for stimulation and recording. Using this platform, we demonstrate recording and stimulation with minimal impact on nerve function, while EA lead wire breakage and tip fracture could limit long-term device use.


Asunto(s)
Estimulación Eléctrica , Electrocorticografía , Electrodos Implantados , Nervio Ciático , Corteza Somatosensorial , Animales , Estimulación Eléctrica/efectos adversos , Electrocorticografía/efectos adversos , Electrocorticografía/normas , Electrodos Implantados/efectos adversos , Electrodos Implantados/normas , Modelos Animales , Ratas
11.
J Biomed Opt ; 24(4): 1-10, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30989838

RESUMEN

Near-infrared spectroscopy (NIRS) is emerging as a rapid, low-cost approach for point-of-care triage of hematomas resulting from traumatic brain injury. However, there remains a lack of standardized test methods for benchtop performance assessment of these devices and incomplete understanding of relevant light-tissue interactions. We propose a phantom-based test method for systems operating near the 800-nm oxy-/deoxy-hemoglobin isosbestic point and implement it to evaluate a clinical system. Semi-idealized phantom geometries are designed to represent epidural/subdural, subarachnoid, and intracerebral hemorrhages. Measurements of these phantoms are made with a commercial NIRS-based hematoma detector to quantify the effect of hematoma type, depth, and size, as well as measurement repeatability and detector positioning relative to the hematoma. Results indicated high sensitivity to epidural/subdural and subarachnoid hematomas. Intracerebral hematomas are detectable to a maximum depth of ∼2.5 cm, depending on thickness and diameter. The maximum lateral detection area for the single-emitter/single-collector device studied here appears elliptical and decreases strongly with inclusion depth. Overall, this study provides unique insights into hematoma detector function and indicates the utility of modular polymer tissue phantoms in performance tests for emerging NIRS-based cerebral diagnostic technology.


Asunto(s)
Hematoma/diagnóstico por imagen , Fantasmas de Imagen , Espectroscopía Infrarroja Corta , Humanos , Reproducibilidad de los Resultados , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos
12.
Bioelectron Med ; 5: 2, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32232093

RESUMEN

The Cleveland Neural Engineering Workshop (NEW) was established as a biennial meeting in 2011, with subsequent meetings taking place in 2013, 2015, and most recently, June 2017. This fourth biennial NEW was hosted by the Cleveland Advanced Platform for Technology National Veterans Affairs Center, the Functional Electrical Stimulation National Veterans Affairs Center, the Biomedical Engineering Department at Case Western Reserve University in Cleveland, Ohio, and Northwell Health's Feinstein Institute for Medical Research of New York. The workshop connects leaders and stakeholders in the neural engineering community who are devoted to developing and deploying technological solutions to those with neurological disorders. The meeting in 2017 continued strategic conversations initiated at the third Cleveland NEW conference in 2015. The goal of the 2017 workshop was to was to determine specific actions by which the neural engineering community might advance the goals outlined in 2015, assess progress towards that plan, adjust as necessary, and establish continued strategic direction. This meeting report summarizes the outcomes.

13.
Sci Rep ; 9(1): 15518, 2019 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-31664091

RESUMEN

Exposure of the brain to high-intensity stress waves creates the potential for long-term functional deficits not related to thermal or cavitational damage. Possible sources of such exposure include overpressure from blast explosions or high-intensity focused ultrasound (HIFU). While current ultrasound clinical protocols do not normally produce long-term neurological deficits, the rapid expansion of potential therapeutic applications and ultrasound pulse-train protocols highlights the importance of establishing a safety envelope beyond which therapeutic ultrasound can cause neurological deficits not detectable by standard histological assessment for thermal and cavitational damage. In this study, we assessed the neuroinflammatory response, behavioral effects, and brain micro-electrocorticographic (µECoG) signals in mice following exposure to a train of transcranial pulses above normal clinical parameters. We found that the HIFU exposure induced a mild regional neuroinflammation not localized to the primary focal site, and impaired locomotor and exploratory behavior for up to 1 month post-exposure. In addition, low frequency (δ) and high frequency (ß, γ) oscillations recorded by ECoG were altered at acute and chronic time points following HIFU application. ECoG signal changes on the hemisphere ipsilateral to HIFU exposure are of greater magnitude than the contralateral hemisphere, and persist for up to three months. These results are useful for describing the upper limit of transcranial ultrasound protocols, and the neurological sequelae of injury induced by high-intensity stress waves.


Asunto(s)
Lesiones Encefálicas/diagnóstico por imagen , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Animales , Lesiones Encefálicas/patología , Lesiones Encefálicas/fisiopatología , Electroencefalografía , Conducta Exploratoria , Locomoción , Estudios Longitudinales , Ratones
14.
J Neural Eng ; 16(6): 063002, 2019 11 12.
Artículo en Inglés | MEDLINE | ID: mdl-31557730

RESUMEN

OBJECTIVE: Recent advances in neural engineering have restored mobility to people with paralysis, relieved symptoms of movement disorders, reduced chronic pain, restored the sense of hearing, and provided sensory perception to individuals with sensory deficits. APPROACH: This progress was enabled by the team-based, interdisciplinary approaches used by neural engineers. Neural engineers have advanced clinical frontiers by leveraging tools and discoveries in quantitative and biological sciences and through collaborations between engineering, science, and medicine. The movement toward bioelectronic medicines, where neuromodulation aims to supplement or replace pharmaceuticals to treat chronic medical conditions such as high blood pressure, diabetes and psychiatric disorders is a prime example of a new frontier made possible by neural engineering. Although one of the major goals in neural engineering is to develop technology for clinical applications, this technology may also offer unique opportunities to gain insight into how biological systems operate. MAIN RESULTS: Despite significant technological progress, a number of ethical and strategic questions remain unexplored. Addressing these questions will accelerate technology development to address unmet needs. The future of these devices extends far beyond treatment of neurological impairments, including potential human augmentation applications. Our task, as neural engineers, is to push technology forward at the intersection of disciplines, while responsibly considering the readiness to transition this technology outside of the laboratory to consumer products. SIGNIFICANCE: This article aims to highlight the current state of the neural engineering field, its links with other engineering and science disciplines, and the challenges and opportunities ahead. The goal of this article is to foster new ideas for innovative applications in neurotechnology.


Asunto(s)
Bioingeniería/tendencias , Enfermedad Crónica/rehabilitación , Enfermedad Crónica/tendencias , Invenciones/tendencias , Enfermedades del Sistema Nervioso/rehabilitación , Bioingeniería/métodos , Predicción , Humanos
15.
Neuron ; 99(4): 635-639, 2018 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-30138587

RESUMEN

As scientists and engineers, we must recognize the overwhelming evidence that we each harbor bias that influences our professional decisions. Yet, solving today's increasingly complex public health challenges requires diverse perspectives from multidisciplinary teams. We all have the opportunity to actively promote a more representative scientific community; let's harness the power of collective action to build diverse teams that deliver the most innovative science.


Asunto(s)
Personal de Laboratorio/psicología , Personal de Laboratorio/normas , Factores Raciales/normas , Sexismo/psicología , Conducta Cooperativa , Humanos , Comunicación Interdisciplinaria , Tutoría/normas , Tutoría/tendencias , Factores Raciales/tendencias , Sexismo/prevención & control , Sexismo/tendencias
16.
Rev Sci Instrum ; 89(9): 094301, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30278703

RESUMEN

Novel therapeutic applications for neural implants require miniaturized devices. Miniaturization imposes stricter requirements for reliability of materials. Pilot clinical studies suggest that rapid failure of the miniaturized neural implants in the body presents a major challenge for this type of technology. Traditional evaluations of neural implant performance over clinically relevant durations present time- and resource-intensive experiments in animals. Reactive accelerated aging (RAA) is an in vitro test platform that was developed to expedite durability testing of neural implants, as a screening technique designed to simulate the aggressive physiological environment experienced by the implants. This approach employs hydrogen peroxide, which mimics reactive oxygen species, and a high temperature to accelerate chemical reactions that lead to device degradation similar to that found with devices implanted in vivo. The original RAA system required daily manual maintenance and was prone to variability in performance. To address these limitations, this work introduces automated reactive accelerated aging (aRAA) with closed-loop monitoring components that make the system simple, robust, and scalable. The core novel technology in the aRAA is electrochemical detection for feedback control of hydrogen peroxide concentration, implemented with simple off-the-shelf components. The aRAA can run multiple parallel experiments for high-throughput device testing and optimization. For this reason, the aRAA provides a simple tool for rapid in vitro evaluation of the durability of neural implants, ultimately expediting the development of a new generation of miniaturized devices with a long functional lifespan.


Asunto(s)
Electrodos Implantados , Automatización , Electroquímica , Peróxido de Hidrógeno/metabolismo , Reproducibilidad de los Resultados , Temperatura , Factores de Tiempo
17.
Micromachines (Basel) ; 9(11)2018 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-30424513

RESUMEN

Characterizing the aging processes of electrodes in vivo is essential in order to elucidate the changes of the electrode⁻tissue interface and the device. However, commonly used impedance measurements at 1 kHz are insufficient for determining electrode viability, with measurements being prone to false positives. We implanted cohorts of five iridium oxide (IrOx) and six platinum (Pt) Utah arrays into the sciatic nerve of rats, and collected the electrochemical impedance spectroscopy (EIS) up to 12 weeks or until array failure. We developed a method to classify the shapes of the magnitude and phase spectra, and correlated the classifications to circuit models and electrochemical processes at the interface likely responsible. We found categories of EIS characteristic of iridium oxide tip metallization, platinum tip metallization, tip metal degradation, encapsulation degradation, and wire breakage in the lead. We also fitted the impedance spectra as features to a fine-Gaussian support vector machine (SVM) algorithm for both IrOx and Pt tipped arrays, with a prediction accuracy for categories of 95% and 99%, respectively. Together, this suggests that these simple and computationally efficient algorithms are sufficient to explain the majority of variance across a wide range of EIS data describing Utah arrays. These categories were assessed over time, providing insights into the degradation and failure mechanisms for both the electrode⁻tissue interface and wire bundle. Methods developed in this study will allow for a better understanding of how EIS can characterize the physical changes to electrodes in vivo.

19.
Bioelectron Med (Lond) ; 1(4): 251-263, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33859830

RESUMEN

Novel technology and innovative stimulation paradigms allow for unprecedented spatiotemporal precision and closed-loop implementation of neurostimulation systems. In turn, precise, closed-loop neurostimulation appears to preferentially drive neural plasticity in motor networks, promoting neural repair. Recent clinical studies demonstrate that electrical stimulation can drive neural plasticity in damaged motor circuits, leading to meaningful improvement in users. Future advances in these areas hold promise for the treatment of a wide range of motor systems disorders.

20.
IEEE Trans Biomed Eng ; 65(6): 1272-1280, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28858781

RESUMEN

OBJECTIVE: We aim to demonstrate the in vivo capability of a wearable sensor technology to detect localized perturbations of sensory-evoked brain activity. METHODS: Cortical somatosensory evoked potentials (SSEPs) were recorded in mice via wearable, flexible epidermal electrode arrays. We then utilized the sensors to explore the effects of transcranial focused ultrasound, which noninvasively induced neural perturbation. SSEPs recorded with flexible epidermal sensors were quantified and benchmarked against those recorded with invasive epidural electrodes. RESULTS: We found that cortical SSEPs recorded by flexible epidermal sensors were stimulus frequency dependent. Immediately following controlled, focal ultrasound perturbation, the sensors detected significant SSEP modulation, which consisted of dynamic amplitude decreases and altered stimulus-frequency dependence. These modifications were also dependent on the ultrasound perturbation dosage. The effects were consistent with those recorded with invasive electrodes, albeit with roughly one order of magnitude lower signal-to-noise ratio. CONCLUSION: We found that flexible epidermal sensors reported multiple SSEP parameters that were sensitive to focused ultrasound. This work therefore 1) establishes that epidermal electrodes are appropriate for monitoring the integrity of major CNS functionalities through SSEP; and 2) leveraged this technology to explore ultrasound-induced neuromodulation. The sensor technology is well suited for this application because the sensor electrical properties are uninfluenced by direct exposure to ultrasound irradiation. SIGNIFICANCE: The sensors and experimental paradigm we present involve standard, safe clinical neurological assessment methods and are thus applicable to a wide range of future translational studies in humans with any manner of health condition.


Asunto(s)
Encéfalo/fisiología , Potenciales Evocados Somatosensoriales/fisiología , Monitorización Neurofisiológica , Ultrasonografía Doppler Transcraneal/métodos , Animales , Electrodos , Epidermis/fisiología , Diseño de Equipo , Ratones , Ratones Endogámicos C57BL , Monitorización Neurofisiológica/instrumentación , Monitorización Neurofisiológica/métodos , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA