Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
N Engl J Med ; 387(14): 1292-1302, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36036522

RESUMEN

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Humanos , Estudios Prospectivos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 32(9): 2371-2378, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34322918

RESUMEN

BACKGROUND: Transvenous implantable cardioverter defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs. STUDY DESIGN: The EV ICD pivotal study is a prospective, multicenter, single-arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled. OBJECTIVE: The clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events. CONCLUSION: The EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Prospectivos , Resultado del Tratamiento
3.
Europace ; 17(11): 1720-6, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26037794

RESUMEN

AIMS: This study aims to demonstrate that primary prevention (PP) patients with one or more additional risk factors are at a similar risk of life-threatening ventricular arrhythmias when compared with secondary prevention (SP) patients, and would receive similar benefit from an implantable cardioverter defibrillator (ICD), or cardiac resynchronization therapy-defibrillator (CRT-D) implant. The study evaluates the benefits of therapy for high-risk patients in countries where defibrillation therapy for PP of SCA is underutilized. METHODS: Enrolment will consist of 4800 ICD-eligible patients from Asia, Latin America, Eastern Europe, the Middle East, and Africa. Upon enrolment, patients will be categorized as SP or PP. Primary prevention patients will be assessed for additional risk factors: syncope/pre-syncope, non-sustained ventricular tachycardia, frequent premature ventricular contractions, and low left ventricular ejection fraction. Those PP patients with one or more risk factors will be categorized as '1.5' patients. Implant of an ICD/CRT-D will be left to the patient and/or physician's discretion. The primary endpoint will compare the appropriate ICD therapy rate between SP and 1.5 patients. The secondary endpoint compares mortality between 1.5 implanted and non-implanted patients. CONCLUSION: The Improve SCA study will investigate a subset of PP patients, believed to be at similar risk of life-threatening ventricular arrhythmias as SP patients. Results may help clinicians identify and refer the highest risk PP patients for ICDs, help local societies expand guidelines to include PP of SCA utilizing ICDs, and provide additional geographical-relevant evidence to allow patients to make an informed decision whether to receive an ICD. TRIAL REGISTRATION: NCT02099721.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/prevención & control , Países Desarrollados , Cardioversión Eléctrica , Prevención Primaria/métodos , Prevención Secundaria/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Dispositivos de Terapia de Resincronización Cardíaca , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Humanos , Selección de Paciente , Prevención Primaria/instrumentación , Estudios Prospectivos , Proyectos de Investigación , Medición de Riesgo , Factores de Riesgo , Prevención Secundaria/instrumentación , Factores de Tiempo , Resultado del Tratamiento
4.
Circ Arrhythm Electrophysiol ; 13(5): e008280, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32281393

RESUMEN

BACKGROUND: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. METHODS: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. RESULTS: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; P<0.001), an effect that sustained beyond 12 months (hazard ratio through all follow-up, 2.30 [95% CI, 1.29-4.07]; P=0.004). Quality of life was reduced (P=0.004) and did not normalize for 6 months. Disruptions in CIED therapy were experienced in 36% of infections for a median duration of 184 days. Mean costs were $55 547±$45 802 for the hospital, $26 867±$14 893, for medicare fee for service and $57 978±$29 431 for Medicare Advantage (mean hospital margin of -$30 828±$39 757 for medicare fee for service and -$6055±$45 033 for medicare advantage). Mean out-of-pocket costs for patients were $2156±$1999 for medicare fee for service, and $1658±$1250 for medicare advantage. CONCLUSIONS: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system. Registration: URL: https://www.clinicaltrials.gov Unique Identifier: NCT02277990.


Asunto(s)
Antibacterianos/economía , Antibacterianos/uso terapéutico , Profilaxis Antibiótica/economía , Desfibriladores Implantables/economía , Costos de la Atención en Salud , Recursos en Salud/economía , Marcapaso Artificial/economía , Infecciones Relacionadas con Prótesis/economía , Infecciones Relacionadas con Prótesis/prevención & control , Anciano , Anciano de 80 o más Años , Antibacterianos/efectos adversos , Profilaxis Antibiótica/efectos adversos , Causas de Muerte , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/economía , Costos de los Medicamentos , Planes de Aranceles por Servicios/economía , Femenino , Gastos en Salud , Costos de Hospital , Humanos , Tiempo de Internación/economía , Masculino , Medicare/economía , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Readmisión del Paciente/economía , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Calidad de Vida , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
5.
Sci Transl Med ; 8(357): 357ra123, 2016 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-27655849

RESUMEN

Natural killer (NK) cells are an emerging cellular immunotherapy for patients with acute myeloid leukemia (AML); however, the best approach to maximize NK cell antileukemia potential is unclear. Cytokine-induced memory-like NK cells differentiate after a brief preactivation with interleukin-12 (IL-12), IL-15, and IL-18 and exhibit enhanced responses to cytokine or activating receptor restimulation for weeks to months after preactivation. We hypothesized that memory-like NK cells exhibit enhanced antileukemia functionality. We demonstrated that human memory-like NK cells have enhanced interferon-γ production and cytotoxicity against leukemia cell lines or primary human AML blasts in vitro. Using mass cytometry, we found that memory-like NK cell functional responses were triggered against primary AML blasts, regardless of killer cell immunoglobulin-like receptor (KIR) to KIR-ligand interactions. In addition, multidimensional analyses identified distinct phenotypes of control and memory-like NK cells from the same individuals. Human memory-like NK cells xenografted into mice substantially reduced AML burden in vivo and improved overall survival. In the context of a first-in-human phase 1 clinical trial, adoptively transferred memory-like NK cells proliferated and expanded in AML patients and demonstrated robust responses against leukemia targets. Clinical responses were observed in five of nine evaluable patients, including four complete remissions. Thus, harnessing cytokine-induced memory-like NK cell responses represents a promising translational immunotherapy approach for patients with AML.


Asunto(s)
Citocinas/farmacología , Memoria Inmunológica/efectos de los fármacos , Células Asesinas Naturales/inmunología , Leucemia Mieloide Aguda/inmunología , Traslado Adoptivo , Anciano , Animales , Proliferación Celular/efectos de los fármacos , Femenino , Humanos , Leucemia Mieloide Aguda/patología , Ligandos , Masculino , Ratones , Persona de Mediana Edad , Receptores de Células Asesinas Naturales/metabolismo , Inducción de Remisión , Ensayos Antitumor por Modelo de Xenoinjerto
6.
Heart Rhythm ; 10(5): 685-91, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23333721

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Marcapaso Artificial/efectos adversos , Anciano , Seguridad de Equipos , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos , Resultado del Tratamiento
7.
Heart Rhythm ; 10(12): 1815-21, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24096164

RESUMEN

BACKGROUND: Although there are several hazards for patients with implanted pacemakers and defibrillators in the magnetic resonance imaging (MRI) environment, evaluation of lead electrode heating is the most complex because of the many influencing variables: patient size, anatomy, body composition, patient position in the bore, scan sequence (radiofrequency power level), lead routing, and lead design. Although clinical studies are an important step in demonstrating efficacy, demonstrating safety through clinical trials alone is not practical because of this complexity. OBJECTIVE: The purpose of this study was to develop a comprehensive modeling framework to predict the probability of pacing capture threshold (PCT) change due to lead electrode heating in the MRI environment and thus provide a robust safety evaluation. METHODS: The lead heating risk was assessed via PCT change because this parameter is the most clinically relevant measure of lead heating. The probability for PCT change was obtained by combining the prediction for power at the electrode-tissue interface obtained via simulations with a prediction for PCT change as a function of radiofrequency power obtained via an in vivo canine study. RESULTS: The human modeling framework predicted that the probability of a 0.5-V PCT change due to an MRI scan for the Medtronic CapSureFix MRI SureScan model 5086 MRI leads is <1/70,000 for chest scans and <1/10,000,000 for either head scans or lower torso scans. CONCLUSION: The framework efficiently models millions of combinations, delivering a robust evaluation of the lead electrode heating hazard. This modeling approach provides a comprehensive safety evaluation that is impossible to achieve using phantom testing, animal studies, or clinical trials alone.


Asunto(s)
Arritmias Cardíacas/terapia , Simulación por Computador , Imagen por Resonancia Cinemagnética/métodos , Marcapaso Artificial , Animales , Arritmias Cardíacas/diagnóstico , Modelos Animales de Enfermedad , Perros , Diseño de Equipo , Seguridad de Equipos , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA